<table><tr><td colspan="8">*** SAMPLE HISTORY***</td></tr><tr><td colspan="8">CUSTOMER: DPC</td></tr><tr><td colspan="8">CUSTOMER P/N:</td></tr><tr><td colspan="8">DELTA MODEL: BFB1012EF-0018H</td></tr><tr><td rowspan="2">REV.</td><td rowspan="2">DESCRIPTION</td><td rowspan="2">DRAWN</td><td colspan="3">CHECKED</td><td rowspan="2">APPROVED</td><td rowspan="2">ISSUE DATE</td></tr><tr><td>ME</td><td>EE</td><td>CE</td></tr><tr><td>00</td><td>ISSUE SPEC</td><td>CHUTIPON.UANS MAY.10.2019</td><td>GITSANAPOL.PATA MAY.10.2019</td><td>AEK MAY.10.2019</td><td>-</td><td>AEK</td><td>MAY.10.2019</td></tr><tr><td>01</td><td>1.ADD 2D BARCODE ON LABEL.2.MODIFY PWM PAGE DESCRIPTION &amp; PWM OPERATION RANGE</td><td>邱繼儒JIRU.CHIUMAY.22.2019</td><td>謝思勇MIKE.HSIEHMAY.22.2019</td><td>王文志WENZHI.WANG MAY.22.2019</td><td>--</td><td>蔡尚賀ARLEN.TSAIMAY.22.2019</td><td>MAY.22.2019</td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td>***</td></tr></table>

## SPECIFICATION FOR APPROVAL

Customer. DPC

Description. DC BLOWER

Part No. \_\_\_\_ REV. \_\_\_\_

Delta Model No. BFB1012EF-0018H REV. 01

Sample Issue No. \_\_\_\_

Sample Issue Date. MAY.22.2019

PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK

AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-

ARRANGMENT.

APPROVED BY: \_\_\_\_

DATE : \_\_\_\_

DELTA ELECTRONICS (THAILAND) PCL.

111 MOO 9, WELLGROW INDUSTRIAL ESTATE,

BANGNA-TRAD ROAD, BANGWUA, BANGPAKONG,

CHACHEONGSAO 24180 THAILAND.

TEL : +66-(0)38-522360-8

FAX : +66-(0)38-522477

DELTA ELECTRONICS (THAILAND) PCL.
111 MOO 9, WELLGROW INDUSTRIAL ESTATE,
BANGNA-TRAD ROAD, BANGWUA, BANGPAKONG,
CHACHEONGSAO 24180 THAILAND.

TEL : +66-(0)38-522360-8

FAX : +66-(0)38-522477

STATEMENT OF DEVIATION
\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*

NONE

DESCRIPTION :

# DELTA ELECTRONICS (THAILAND) PCL. 111 MOO 9, WELLGROW INDUSTRIAL ESTATE, BANGNA-TRAD ROAD, BANGWUA, BANGPAKONG, CHACHEONGSAO 24180 THAILAND.

TEL : +66-(0)38-522360-8

FAX : +66-(0)38-522477

SPECIFICATION FOR APPROVAL
\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*\*

<table><tr><td>Customer:</td><td>DPC</td><td></td></tr><tr><td>Description:</td><td>DC BLOWER</td><td></td></tr><tr><td>Customer P/N:</td><td></td><td>REV:</td></tr><tr><td>Delta Model NO.:</td><td>BFB1012EF-0018H</td><td>Delta safety model NO.: N/A</td></tr><tr><td>Sample Rev:</td><td>01</td><td>Issue NO:</td></tr><tr><td>Sample Issue Date:</td><td>MAY.22.2019</td><td>Quantity:</td></tr></table>

1. SCOPE:

THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL CHARACTERISTICS OF THE DC BRUSHLESS BLOWER.

2. CHARACTERS:

<table><tr><td>ITEM</td><td>DESCRIPTION</td></tr><tr><td>RATED VOLTAGE</td><td>12 VDC</td></tr><tr><td>OPERATION VOLTAGE</td><td>10.8 - 12.6 VDC</td></tr><tr><td>PWM MINIMUM START DUTY</td><td>30% (MAX) @12V, 25KHZ</td></tr><tr><td>RATED CURRENT (AVG.)</td><td>5.00 (MAX. 6.00) ASAFETY CURRENT ON LABEL : N/A</td></tr><tr><td>RATED POWER (AVG.)</td><td>60.00 (MAX. 72.00) W</td></tr><tr><td>RATED SPEED</td><td>7500 ± 10% R.P.M.</td></tr><tr><td>MAX. AIR FLOW(AT ZERO STATIC PRESSURE)</td><td>1.588 (MIN. 1.429) M /MIN.56.08 (MIN. 50.47) CFM</td></tr><tr><td>MAX. AIR PRESSURE(AT ZERO AIRFLOW)</td><td>175.35 (MIN. 142.03) mmH  $O_{2}$ 6.903 (MIN. 5.592) inchH  $O_{2}$ </td></tr><tr><td>ACOUSTICAL NOISE (AVG.)</td><td>69.0 (MAX. 73.0) dB-A</td></tr><tr><td>INSULATION TYPE</td><td>UL: CLASS A</td></tr></table>

(continued)

PART NO:

BFB1012EF-0018H

<table><tr><td>INSULATION STRENGTH</td><td>10 MEG OHM MIN. AT 500 VDC(BETWEEN FRAME AND (+) TERMINAL)</td></tr><tr><td>DIELECTRIC STRENGTH</td><td>5 mA MAX. AT 500 VAC 50/60 HzONE MINUTE, (BETWEEN FRAME AND(+) TERMINAL)</td></tr><tr><td>LIFE EXPECTANCE (L10)(AT LABEL VOLTAGE)</td><td>50,000 HOURS CONTINUOUS OPERATIONAT 50 °C WITH 15 ~ 65 %RH.</td></tr><tr><td>ROTATION</td><td>CLOCKWISE VIEWFROM NAME PLATE SIDE</td></tr><tr><td>OVER CURRENT SHUT DOWN</td><td>THE CURRENT WILL SHUT DOWN WHENLOCKING ROTOR</td></tr></table>

NOTES: 1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP THROUGH 10 MINUTES.  
2. STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65% RELATIVE HUMIDITY, AND (Pb) 760 mmHg BAROMETRIC PRESSURE.  
3. THE VALUES WRITTEN IN PARENS, ( ), ARE LIMITED SPEC.  
4. ACOUSTICAL NOISE MEASURING CONDITION:

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2Feaf6c3910e7b49ba3a04f5baf6f0d49d685677c1a99469ae6fbafe7a0c2d3c1c.jpg)  
NOISE IS MEASURED AT RATED VOLTAGE IN FREE AIR IN ANECHOIC CHAMBER WITH B & K SOUND LEVEL METER WITH MICROPHONE AT A DISTANCE OF ONE METER FROM THE FAN INTAKE.

PART NO:

DELTA MODEL: BFB1012EF-0018H

3. MECHANICAL:

3-1. DIMENSIONS SEE DIMENSIONS DRAWING

3-2. FRAME PLASTIC UL: 94V-0

3-3. IMPELLER PLASTIC UL: 94V-0

3-4. BEARING SYSTEM —— TWO BALL BEARINGS

3-5. WEIGHT 180 GRAMS (REF.)

## 4. ENVIRONMENTAL:

4-1. OPERATING TEMPERATURE -10 TO +70 DEGREE C

4-2. STORAGE TEMPERATURE -40 TO +75 DEGREE C

4-3. OPERATING HUMIDITY 5 TO $90\%$ RH

4-4. STORAGE HUMIDITY 5 TO $95\%$ RH

## 5. PROTECTION:

## 5- 1. LOCKED ROTOR PROTECTION

IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN 96 HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE.

## 5- 2. POLARITY PROTECTION

BE CAPABLE OF WITHSTANDING IF REVERSE CONNECTION FOR POSITIVE AND NEGATIVE LEADS.

## 6. RE OZONE DEPLETING SUBSTANCES:

6-1. NO CONTAINING PBBs, PBBOs, CFCs, PBBEs, PBDPEs AND HCFCs.

## 7. PRODUCTION LOCATION

7- 1. PRODUCTS WILL BE PRODUCED IN THAILAND.

<table><tr><td colspan="2">PART NO:</td></tr><tr><td>DELTA MODEL:</td><td>BFB1012EF-0018H</td></tr></table>

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F85fbb05b1b14e1f0968cfa86f819d058fd8dcae37385c24ba5bf6e0cec7caddf.jpg)

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2Fe05fc86a181ba3492f16bb10ee78d9511065df8e6f6fd46dcea6f6746334c992.jpg)

PART NO:

DELTA MODEL:

BFB1012EF-0018H

9. DIMENSION DRAWING:

LABEL:

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2Fa54ff8bcc465301e68be4a376a7b6da68ee79a3c685b6f0e38a39547d962015a.jpg)

2D BARCODE

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F12199072d49ad4ff94f43c7b2dca4309a544f3e9e2883126b7469d5015864ef7.jpg)

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F02b3bca34aec67c2290a1fcfe80b71e9db0b7d38a2029eaccc0724da2017db86.jpg)

UNIT: mm(INCH)

NOTES:

1.WIRE: UL1007 AWG#24

RED WIRE ---- (+)

BLACK WIRE ---- (-)

BLUE WIRE ---- (-FOO)

YELLOW WIRE ---- (PWM)

2. THIS PRODUCT IS RoHS COMPLIANT.

\*4 POLES

CAUTION:

$$
\mathrm{TS} = 6 0 / \mathrm{N(SEC)}
$$

<table><tr><td colspan="2">PART NO:</td></tr><tr><td>DELTA MODEL:</td><td>BFB1012EF-0018H</td></tr></table>

10. FREQUENCY GENERATOR (FG) SIGNAL:

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2Fef2ddb4b843acca161c84ae2124e2b77176d4d59b116f2e5ffe2e45c9300f8a5.jpg)

THE LEAD WIRE OF FG SIGNAL CAN NOT TOUCH
THE LEAD WIRE OF POSITIVE OR NEGATIVE.

10-2. SPECIFICATION:

10-3. FREQUENCY GENERATOR WAVEFORM:

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F9dd8e863b902a915c4e72155f2ca87db8332ef04a87f89ccc579aa972b92e7bc.jpg)

FAN RUNNING FOR 4 POLES  
![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F2c46e5aacf59c3d6c8615cde5454595693c8b4f8525a565bd4d185b66022a73d.jpg)  
N=R.P.M

\*VOLTAGE LEVEL AFTER BLADE LOCKED

PART NO:

DELTA MODEL:

BFB1012EF-0018H

11. PWM CONTROL SIGNAL:

1 SIGNAL VOLTAGE RANGE: 0\~5.0 VDC

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F49daf38dde0554f770ee86cfe2bfff9026603883264e0730dbc9e6d677881bf9.jpg)

LOW SIGNAL:

DUTY CYCLE= $\frac{t}{T}$ \*100(%)

0.4 VDC MAX.
0 VDC MIN.

\- THE PREFERRED OPERATING POINT FOR THE FAN IS 25KHZ.

\- AT 100% DUTY CYCLE, THE ROTOR WILL SPIN AT MAXIMUM SPEED.

\- AT 0% DUTY CYCLE, THE ROTOR WILL STOP SPINNING.

\- WITH CONTROL SIGNAL LEAD DISCONNECTED, THE FAN WILL SPIN AT MAXIMUM SPEED.

\- AT 25K HZ 30% DUTY CYCLE, THE FAN WILL BE ABLE TO START FROM A DEAD STOP.

12. SPEED VS PWM CONTROL SIGNAL: (AT RATED VOLTAGE & PWM FRUQUENCY=25KHZ)

<table><tr><td>DUTY CYCLE (%)</td><td>SPEED R.P.M. (REF.)</td><td>CURRENT (A) TYP.</td></tr><tr><td>100</td><td>7500 ± 10%</td><td>5.00</td></tr><tr><td>0</td><td>0</td><td>0.02</td></tr></table>

13. PWM CONTROL LEAD WIRE INPUT IMPEDANCE:

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2F6c724dac0e60d9349bcb27943f7c9452b01b991f1d42f8fe1f020baf59080038.jpg)

![](https://www.embedr.app/api/datasheets/ds_004fca830690b0129503/asset?path=images%2Fafa897850e5d1892e5544a7628177f7fa09caa3948443914b59d60105615fc38.jpg)

\- MIN. STARTED DUTY CYCLE(AT 25°C & RATED VOLTAGE): MAX. 30% WHEN DUTY CYCLE IS SET FOR MORE THAN 30%THE FAN WILL BE ABLE TO START FROM A DEAD STOP.

## Application Notice

1. Delta will not guarantee the performance of the products if the application condition falls outside the parameters set forth in the specification.

2. A written request should be submitted to Delta prior to approval if deviation from this specification is required.

3. Please exercise caution when handling fans. Damage may be caused when pressure is applied to the impeller, if the fans are handled by the lead wires, or if the fan was hard-dropped to the production floor.

4. Except as pertains to some special designs, there is no guarantee that the products will be free from any such safety problems or failures as caused by the introduction of powder, droplets of water or encroachment of insect into the hub.

5. The above-mentioned conditions are representative of some unique examples and viewed as the first point of reference prior to all other information.

6. It is very important to establish the correct polarity before connecting the fan to the power source. Positive (+) and Negative (-). Damage may be caused to the fans if connection is with reverse polarity, if there is no foolproof method to protect against such error specifically mentioned in this spec.

7. Delta fans without special protection are not suitable where any corrosive fluids are introduced to their environment.

8. Please ensure all fans are stored according to the storage temperature limits specified. Do not store fans in a high humidity environment. We highly recommend performance testing is conducted before shipping, if the fans have been stored over 6 months.

9. Not all fans are provided with the Lock Rotor Protection feature. If you impair the rotation of the impeller for the fans that do not have this function, the performance of those fans will lead to failure.

10. Please be cautious when mounting the fan. Incorrect mounting of fans may cause excess resonance, vibration and subsequent noise.

11. It is important to consider safety when testing the fans. A suitable fan guard should be fitted to the fan to guard against any potential for personal injury.

12. Except where specifically stated, all tests are carried out at room (ambient) temperature and relative humidity conditions of $25^{\circ}$ C, 65% RH. The test value is only for fan performance itself.

13. Be certain to connect an “4.7 $\mu$ F or greater” capacitor to the fan externally when the application calls for using multiple fans in parallel, to avoid any unstable power.