{"datasheetId":"ds_056dacd83f0fd405c8ff","chunkCount":190,"revision":"2026-11-09T20:12:51.641Z","source":"index","nextCursor":"49","chunks":[{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0001","chunkIndex":0,"heading":"6-Channel Capacitive Touch Sensor","headingPath":["6-Channel Capacitive Touch Sensor"],"preview":"6 Channel Capacitive Touch Sensor General Description The CAP1206 is a multiple channel capacitive touch sensor controller. It contains six (6) individual capacitive touch sensor inputs with programmable sensitivity for use in touch sensor","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0001"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0002","chunkIndex":1,"heading":"Applications","headingPath":["6-Channel Capacitive Touch Sensor","Applications"],"preview":"Applications • Desktop and Notebook PCs • LCD Monitors • Consumer Electronics • Appliances Features • Six (6) Capacitive Touch Sensor Inputs \\ Programmable sensitivity \\ Automatic recalibration \\ Calibrates for parasitic capacitance \\ Indiv","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0002"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0003","chunkIndex":2,"heading":"TO OUR VALUED CUSTOMERS","headingPath":["TO OUR VALUED CUSTOMERS"],"preview":"TO OUR VALUED CUSTOMERS It is our intention to provide our valued customers with the best documentation possible to ensure successful use of your Microchip products. To this end, we will continue to improve our publications to better suit y","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0003"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0004","chunkIndex":3,"heading":"Most Current Data Sheet","headingPath":["TO OUR VALUED CUSTOMERS","Most Current Data Sheet"],"preview":"Most Current Data Sheet To obtain the most up to date version of this data sheet, please register at our Worldwide Web site at: http://www.microchip.com You can determine the version of a data sheet by examining its literature number found","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0004"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0005","chunkIndex":4,"heading":"Customer Notification System","headingPath":["TO OUR VALUED CUSTOMERS","Customer Notification System"],"preview":"Customer Notification System Register on our web site at www.microchip.com to receive the most current information on all of our products. Table of Contents 1.0 Introduction ...... 4 2.0 Pin Description and Configuration ...... 8 3.0 Functi","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0005"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0006","chunkIndex":5,"heading":"1.0 INTRODUCTION","headingPath":["TO OUR VALUED CUSTOMERS","1.0 INTRODUCTION"],"preview":"1.0 INTRODUCTION 1.1 Block Diagram FIGURE 1 1: CAP1206 BLOCK DIAGRAM 1.2 Pin Diagrams FIGURE 1 2: CAP1206 14 PIN SOIC","images":[{"path":"images/8cc2be36d76d5ab0e7fe732686f9d3cd979bf5fe573aa0911633461327c77c0b.jpg","name":"8cc2be36d76d5ab0e7fe732686f9d3cd979bf5fe573aa0911633461327c77c0b.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/asset?path=images%2F8cc2be36d76d5ab0e7fe732686f9d3cd979bf5fe573aa0911633461327c77c0b.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0006"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0007","chunkIndex":6,"heading":"1.2 Pin Diagrams","headingPath":["TO OUR VALUED CUSTOMERS","1.2 Pin Diagrams"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0007"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0008","chunkIndex":7,"heading":"1.2 Pin Diagrams","headingPath":["TO OUR VALUED CUSTOMERS","1.2 Pin Diagrams"],"preview":"1.3 Pin Description APPLICATION NOTE: All digital pins are 5V tolerant pins. The pin types are described in Table 1 2, \"Pin Types\". TABLE 1 2: PIN TYPES","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0008"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0009","chunkIndex":8,"heading":"2.0 ELECTRICAL SPECIFICATIONS","headingPath":["TO OUR VALUED CUSTOMERS","2.0 ELECTRICAL SPECIFICATIONS"],"preview":"2.0 ELECTRICAL SPECIFICATIONS TABLE 2 1: ABSOLUTE MAXIMUM RATINGS","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0009"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0010","chunkIndex":9,"heading":"2.0 ELECTRICAL SPECIFICATIONS","headingPath":["TO OUR VALUED CUSTOMERS","2.0 ELECTRICAL SPECIFICATIONS"],"preview":"Note 2 1 Stresses above those listed could cause permanent damage to the device. This is a stress rating only and functional operation of the device at any other condition above those indicated in the operation sections of this specificatio","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0010"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0011","chunkIndex":10,"heading":"2.0 ELECTRICAL SPECIFICATIONS","headingPath":["TO OUR VALUED CUSTOMERS","2.0 ELECTRICAL SPECIFICATIONS"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0011"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0012","chunkIndex":11,"heading":"2.0 ELECTRICAL SPECIFICATIONS","headingPath":["TO OUR VALUED CUSTOMERS","2.0 ELECTRICAL SPECIFICATIONS"],"preview":"3.0 COMMUNICATIONS 3.1 Communications The CAP1206 communicates using the SMBus or I","images":[{"path":"images/48ff0ead8c3966338c93ba351c16439d72c843dabc7f242bbfb8cab166e8a533.jpg","name":"48ff0ead8c3966338c93ba351c16439d72c843dabc7f242bbfb8cab166e8a533.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/asset?path=images%2F48ff0ead8c3966338c93ba351c16439d72c843dabc7f242bbfb8cab166e8a533.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0012"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0013","chunkIndex":12,"heading":"3.2.1 SMBUS START BIT","headingPath":["TO OUR VALUED CUSTOMERS","3.2.1 SMBUS START BIT"],"preview":"3.2.1 SMBUS START BIT The SMBus Start bit is defined as a transition of the SMBus Data line from a logic ‘1’ state to a logic ‘0’ state while the SMBus Clock line is in a logic ‘1’ state. 3.2.2 SMBUS ADDRESS AND RD / WR BIT The SMBus Addres","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0013"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0014","chunkIndex":13,"heading":"3.2.3 The CAP1206responds to SMBus address 0101\\_000(r/w). SMBUS DATA BYTES","headingPath":["TO OUR VALUED CUSTOMERS","3.2.3 The CAP1206responds to SMBus address 0101\\_000(r/w). SMBUS DATA BYTES"],"preview":"3.2.3 The CAP1206responds to SMBus address 0101\\ 000(r/w). SMBUS DATA BYTES All SMBus Data bytes are sent most significant bit first and composed of 8 bits of information. 3.2.4 SMBUS ACK AND NACK BITS The SMBus client will acknowledge all","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0014"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0015","chunkIndex":14,"heading":"3.2.5 SMBUS STOP BIT","headingPath":["TO OUR VALUED CUSTOMERS","3.2.5 SMBUS STOP BIT"],"preview":"3.2.5 SMBUS STOP BIT The SMBus Stop bit is defined as a transition of the SMBus Data line from a logic ‘0’ state to a logic ‘1’ state while the SMBus clock line is in a logic ‘1’ state. When the CAP1206 detects an SMBus Stop bit and it has","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0015"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0016","chunkIndex":15,"heading":"3.2.7 SMBUS AND I<sup>2</sup>C COMPATIBILITY","headingPath":["TO OUR VALUED CUSTOMERS","3.2.7 SMBUS AND I<sup>2</sup>C COMPATIBILITY"],"preview":"3.2.7 SMBUS AND I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0016"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0017","chunkIndex":16,"heading":"3.2.7 SMBUS AND I<sup>2</sup>C COMPATIBILITY","headingPath":["TO OUR VALUED CUSTOMERS","3.2.7 SMBUS AND I<sup>2</sup>C COMPATIBILITY"],"preview":"6. I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0017"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0018","chunkIndex":17,"heading":"3.3.1 SMBUS WRITE BYTE","headingPath":["TO OUR VALUED CUSTOMERS","3.3.1 SMBUS WRITE BYTE"],"preview":"3.3.1 SMBUS WRITE BYTE The Write Byte is used to write one byte of data to a specific register as shown in Table 3 2. TABLE 3 2: WRITE BYTE PROTOCOL","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0018"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0019","chunkIndex":18,"heading":"3.3.3 SMBUS SEND BYTE","headingPath":["TO OUR VALUED CUSTOMERS","3.3.3 SMBUS SEND BYTE"],"preview":"3.3.3 SMBUS SEND BYTE The Send Byte protocol is used to set the internal address register pointer to the correct address location. No data is transferred during the Send Byte protocol as shown in Table 3 4. APPLICATION NOTE: The Send Byte p","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0019"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0020","chunkIndex":19,"heading":"3.3.4 SMBUS RECEIVE BYTE","headingPath":["TO OUR VALUED CUSTOMERS","3.3.4 SMBUS RECEIVE BYTE"],"preview":"3.3.4 SMBUS RECEIVE BYTE The Receive Byte protocol is used to read data from a register when the internal register address pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads of the same","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0020"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0021","chunkIndex":20,"heading":"3.4 I<sup>2</sup>C Protocols","headingPath":["TO OUR VALUED CUSTOMERS","3.4 I<sup>2</sup>C Protocols"],"preview":"3.4 I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0021"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0022","chunkIndex":21,"heading":"3.4.1 BLOCK READ","headingPath":["TO OUR VALUED CUSTOMERS","3.4.1 BLOCK READ"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0022"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0023","chunkIndex":22,"heading":"4.0 GENERAL DESCRIPTION","headingPath":["TO OUR VALUED CUSTOMERS","4.0 GENERAL DESCRIPTION"],"preview":"4.0 GENERAL DESCRIPTION The CAP1206 is a multiple channel capacitive touch sensor. It contains six (6) individual capacitive touch sensor inputs with programmable sensitivity for use in touch sensor applications. Each sensor input is calibr","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0023"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0024","chunkIndex":23,"heading":"4.0 GENERAL DESCRIPTION","headingPath":["TO OUR VALUED CUSTOMERS","4.0 GENERAL DESCRIPTION"],"preview":"The device communicates with a host controller using SMBus / I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0024"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0025","chunkIndex":24,"heading":"4.1 Power States","headingPath":["TO OUR VALUED CUSTOMERS","4.1 Power States"],"preview":"2. Standby When the STBY bit is set, the device is monitoring the capacitive sensor inputs enabled in the Standby state. Interrupts can still be generated based on the enabled channels. The device will still respond to communications normal","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0025"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0026","chunkIndex":25,"heading":"4.2 Reset","headingPath":["TO OUR VALUED CUSTOMERS","4.2 Reset"],"preview":"4.2 Reset The Power On Reset (POR) circuit holds the device in reset until $\\mathsf { V } { \\mathsf { D D } }$ has reached an acceptable level, Power on Reset Release Voltage $( \\mathsf { V } { \\mathsf { P O R R } } )$ , for minimum operati","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0026"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0027","chunkIndex":26,"heading":"4.2 Reset","headingPath":["TO OUR VALUED CUSTOMERS","4.2 Reset"],"preview":"4.3 Capacitive Touch Sensing The CAP1206 contains six (6) independent capacitive touch sensor inputs. Each sensor input has dynamic range to detect a change of capacitance due to a touch. Additionally, each sensor input can be configured to","images":[{"path":"images/59ab8356556bf4995d99b72979d9dbe2fae60c14941f0e358a90996fd6a6876d.jpg","name":"59ab8356556bf4995d99b72979d9dbe2fae60c14941f0e358a90996fd6a6876d.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/asset?path=images%2F59ab8356556bf4995d99b72979d9dbe2fae60c14941f0e358a90996fd6a6876d.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0027"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0028","chunkIndex":27,"heading":"4.3.1.1 Active State Sensing Settings","headingPath":["TO OUR VALUED CUSTOMERS","4.3.1.1 Active State Sensing Settings"],"preview":"4.3.1.1 Active State Sensing Settings The Active state is used for normal operation. Sensor inputs being monitored are determined by the Sensor Input Enable Register(see Section 5.7, \"Sensor Input Enable Register\"). Sensitivity is controlle","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0028"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0029","chunkIndex":28,"heading":"4.3.1.2 Standby State Sensing Settings","headingPath":["TO OUR VALUED CUSTOMERS","4.3.1.2 Standby State Sensing Settings"],"preview":"4.3.1.2 Standby State Sensing Settings The Standby state is used for standby operation. In general, fewer sensor inputs are enabled, and they are programmed to have more sensitivity. Sensor inputs being monitored are determined by the Stand","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0029"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0030","chunkIndex":29,"heading":"4.3.2 SENSING CYCLE","headingPath":["TO OUR VALUED CUSTOMERS","4.3.2 SENSING CYCLE"],"preview":"4.3.2 SENSING CYCLE Except when in Deep Sleep, the device automatically initiates a sensing cycle and repeats the cycle every time it finishes. The cycle polls through each enabled sensor input starting with CS1 and extending through CS6. A","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0030"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0031","chunkIndex":30,"heading":"4.4 Sensor Input Calibration","headingPath":["TO OUR VALUED CUSTOMERS","4.4 Sensor Input Calibration"],"preview":"4.4 Sensor Input Calibration Calibration sets the Base Count Registers(Section 5.24, \"Sensor Input Base Count Registers\") which contain the “not touched” values used for touch detection comparisons. Calibration automatically occurs after a","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0031"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0032","chunkIndex":31,"heading":"4.4 Sensor Input Calibration","headingPath":["TO OUR VALUED CUSTOMERS","4.4 Sensor Input Calibration"],"preview":"The host controller can force a calibration for selected sensor inputs at any time using the Calibration Activate and Status RegisterSection 5.10.1, \"Calibration Activate and Status Register\". When a bit is set, the corresponding capacitive","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0032"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0033","chunkIndex":32,"heading":"4.4 Sensor Input Calibration","headingPath":["TO OUR VALUED CUSTOMERS","4.4 Sensor Input Calibration"],"preview":"TABLE 4 1: IDEAL BASE COUNTS","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0033"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0034","chunkIndex":33,"heading":"4.4.1 AUTOMATIC RECALIBRATION","headingPath":["TO OUR VALUED CUSTOMERS","4.4.1 AUTOMATIC RECALIBRATION"],"preview":"4.4.1 AUTOMATIC RECALIBRATION Each sensor input is regularly recalibrated at a programmable rate(see CAL\\ CFG[2:0] in Section 5.17, \"Recalibration Configuration Register\"). By default, the recalibration routine stores the average 64 previou","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0034"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0035","chunkIndex":34,"heading":"4.4.2 NEGATIVE DELTA COUNT RECALIBRATION","headingPath":["TO OUR VALUED CUSTOMERS","4.4.2 NEGATIVE DELTA COUNT RECALIBRATION"],"preview":"4.4.2 NEGATIVE DELTA COUNT RECALIBRATION It is possible that the device loses sensitivity to a touch. This may happen as a result of a noisy environment, recalibra tion when the pad is touched but delta counts do not exceed the threshold, o","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0035"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0036","chunkIndex":35,"heading":"4.4.3 DELAYED RECALIBRATION","headingPath":["TO OUR VALUED CUSTOMERS","4.4.3 DELAYED RECALIBRATION"],"preview":"4.4.3 DELAYED RECALIBRATION It is possible that a “stuck button” occurs when something is placed on a button which causes a touch to be detected for a long period. By setting the MAX\\ DUR\\ EN bit(see Section 5.6, \"Configuration Registers\"),","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0036"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0037","chunkIndex":36,"heading":"4.5 Power Button","headingPath":["TO OUR VALUED CUSTOMERS","4.5 Power Button"],"preview":"4.5 Power Button The CAP1206 has a “power button” feature. In general, buttons are set for quick response to a touch, especially when buttons are used for number keypads. However, there are cases where a quick response is not desired, such","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0037"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0038","chunkIndex":37,"heading":"4.6 Multiple Touch Pattern Detection","headingPath":["TO OUR VALUED CUSTOMERS","4.6 Multiple Touch Pattern Detection"],"preview":"4.6 Multiple Touch Pattern Detection The multiple touch pattern (MTP) detection circuitry can be used to detect lid closure or other similar events. An event can be flagged based on either a minimum number of sensor inputs or on specific se","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0038"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0039","chunkIndex":38,"heading":"4.7 Noise Controls","headingPath":["TO OUR VALUED CUSTOMERS","4.7 Noise Controls"],"preview":"4.7 Noise Controls 4.7.1 LOW FREQUENCY NOISE DETECTION Each sensor input has a low frequency noise detector that will sense if low frequency noise is injected onto the input with sufficient power to corrupt the readings. By default, if this","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0039"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0040","chunkIndex":39,"heading":"4.7.2 RF NOISE DETECTION","headingPath":["TO OUR VALUED CUSTOMERS","4.7.2 RF NOISE DETECTION"],"preview":"4.7.2 RF NOISE DETECTION Each sensor input contains an integrated RF noise detector. This block will detect injected RF noise on the CS pin. The detector threshold is dependent upon the noise frequency. By default, if RF noise is detected o","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0040"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0041","chunkIndex":40,"heading":"4.7.3 NOISE STATUS AND CONFIGURATION","headingPath":["TO OUR VALUED CUSTOMERS","4.7.3 NOISE STATUS AND CONFIGURATION"],"preview":"For analog noise, there are options for whether the data should be considered invalid. By default, the DIS\\ ANA\\ NOISE bit (see Section 5.6.1, \"Configuration 20h\") will block a touch on a sensor input if low frequency analog noise is detect","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0041"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0042","chunkIndex":41,"heading":"4.8 Interrupts","headingPath":["TO OUR VALUED CUSTOMERS","4.8 Interrupts"],"preview":"4.8 Interrupts Interrupts are indicated by the setting of the INT bit in the Main Control Register(see Section 5.1, \"Main Control Register\") and by assertion of the ALERT pin. The ALERT pin is cleared when the INT bit is cleared by the user","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0042"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0043","chunkIndex":42,"heading":"4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR","headingPath":["TO OUR VALUED CUSTOMERS","4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR"],"preview":"4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR Each sensor input can be programmed to enable / disable interrupts(see Section 5.11, \"Interrupt Enable Register\"). When enabled for a sensor input and the sensor input is not the designated p","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0043"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0044","chunkIndex":43,"heading":"4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR","headingPath":["TO OUR VALUED CUSTOMERS","4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR"],"preview":"When the repeat rate is enabled for a sensor input (see Section 5.12, \"Repeat Rate Enable Register\"), the device uses an additional control called MPRESS that determines whether a touch is flagged as a simple “touch” or a “press and hold” (","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0044"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0045","chunkIndex":44,"heading":"4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR","headingPath":["TO OUR VALUED CUSTOMERS","4.8.2 CAPACITIVE SENSOR INPUT INTERRUPT BEHAVIOR"],"preview":"APPLICATION NOTE: The host may need to poll the device twice to determine that a release has been detected. FIGURE 4 3: SENSOR INTERRUPT BEHAVIOR REPEAT RATE ENABLED FIGURE 4 4: SENSOR INTERRUPT BEHAVIOR NO REPEAT RATE ENABLED 4.8.3 INTERRU","images":[{"path":"images/49c1d77d6ee2ea4928c774bcfacd66022d9b03f7de68b40435bed42ca1e40a2c.jpg","name":"49c1d77d6ee2ea4928c774bcfacd66022d9b03f7de68b40435bed42ca1e40a2c.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/asset?path=images%2F49c1d77d6ee2ea4928c774bcfacd66022d9b03f7de68b40435bed42ca1e40a2c.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0045"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0046","chunkIndex":45,"heading":"4.8.4 INTERRUPTS FOR MULTIPLE TOUCH PATTERN DETECTION","headingPath":["TO OUR VALUED CUSTOMERS","4.8.4 INTERRUPTS FOR MULTIPLE TOUCH PATTERN DETECTION"],"preview":"4.8.4 INTERRUPTS FOR MULTIPLE TOUCH PATTERN DETECTION An interrupt can be generated when the MTP pattern is matched (see Section 5.14, \"Multiple Touch Pattern Configuration Register\"). 4.8.5 INTERRUPTS FOR SENSOR INPUT CALIBRATION FAILURES","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0046"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0047","chunkIndex":46,"heading":"5.0 REGISTER DESCRIPTION","headingPath":["TO OUR VALUED CUSTOMERS","5.0 REGISTER DESCRIPTION"],"preview":"5.0 REGISTER DESCRIPTION The registers shown in Table 5 1 are accessible through the communications protocol. An entry of ‘ ’ indicates that the bit is not used and will always read ‘0’. TABLE 5 1: REGISTER SET IN HEXADECIMAL ORDER","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0047"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0048","chunkIndex":47,"heading":"5.0 REGISTER DESCRIPTION","headingPath":["TO OUR VALUED CUSTOMERS","5.0 REGISTER DESCRIPTION"],"preview":"During power on reset (POR), the default values are stored in the registers. A POR is initiated when power is first applied to the part and the voltage on the VDD supply surpasses the POR level as specified in the electrical character istic","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0048"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0049","chunkIndex":48,"heading":"5.1 Main Control Register","headingPath":["TO OUR VALUED CUSTOMERS","5.1 Main Control Register"],"preview":"• ‘1’ The device is in the Standby state. Capacitive touch sensor input scanning is limited to the sensor inputs set in the Standby Channel register (see Section 5.20, \"Standby Channel Register\"). The status registers will not be cleared un","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0049"},{"chunkId":"ds_056dacd83f0fd405c8ff-chunk-0050","chunkIndex":49,"heading":"5.1 Main Control Register","headingPath":["TO OUR VALUED CUSTOMERS","5.1 Main Control Register"],"preview":"• ‘1’ An interrupt condition occurred, and the ALERT pin has been asserted. 5.2 Status Registers TABLE 5 3: STATUS REGISTERS","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_056dacd83f0fd405c8ff/chunks/ds_056dacd83f0fd405c8ff-chunk-0050"}]}