{"datasheetId":"ds_24373168a56675dfdf73","chunkCount":22,"revision":"2026-11-09T19:43:18.959Z","source":"index","nextCursor":null,"chunks":[{"chunkId":"ds_24373168a56675dfdf73-chunk-0001","chunkIndex":0,"heading":"LD-P RELAYS","headingPath":["LD-P RELAYS"],"preview":"LD P RELAYS Slim (7.2 mm), 1 Form A 5 A, Power relay Protective construction：Sealed FEATURES Rated switching capacity: 5 A 277 V AC Ambient temperature: 40 to +85°C Excellent heat resistance and tracking performance EN60695 (GWT2 11, GWFI2","images":[{"path":"images/7318cc67db9634326bee6eb26835523efb76abf563ffb4f5f4936af79b23c966.jpg","name":"7318cc67db9634326bee6eb26835523efb76abf563ffb4f5f4936af79b23c966.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Relay package dimensions","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F7318cc67db9634326bee6eb26835523efb76abf563ffb4f5f4936af79b23c966.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0001"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0002","chunkIndex":1,"heading":"TYPICAL APPLICATIONS","headingPath":["LD-P RELAYS","TYPICAL APPLICATIONS"],"preview":"TYPICAL APPLICATIONS Boilers, Hot water units Air conditioner, Fan heaters Refrigerator Microwave ovens （Unit：mm） ORDERING INFORMATION (PART NO.) Note) The \"W\" at the end of the part number only appears on the inner and outer packing. It do","images":[{"path":"images/e40efcd2f26cb8d3db0b580d78be73176e440e11f6894fd8ebfe4b014316f994.jpg","name":"e40efcd2f26cb8d3db0b580d78be73176e440e11f6894fd8ebfe4b014316f994.jpg","mimeType":"image/jpeg","semanticKind":"text_snippet","semanticCaption":"ALDP relay part number designation","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Fe40efcd2f26cb8d3db0b580d78be73176e440e11f6894fd8ebfe4b014316f994.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0002"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0003","chunkIndex":2,"heading":"TYPES","headingPath":["LD-P RELAYS","TYPES"],"preview":"\\ Tube packing types available. When ordering, please remove sufix “W”. RATING Coil data • Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc. Therefore,","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0003"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0004","chunkIndex":3,"heading":"Coil data","headingPath":["LD-P RELAYS","Coil data"],"preview":"\\ 1. square, pulse drive \\ 2. Maximum allowable voltage is the maximum voltage which can satisfy the coil temperature rise value. Please refer to “Max. applied voltage and temperature rise” in GUIDELINES FOR USAGE. Specifications","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0004"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0005","chunkIndex":4,"heading":"Coil data","headingPath":["LD-P RELAYS","Coil data"],"preview":"\\ 1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load \\ 2. Wave is standard shock voltage of ±1.2×50 μs according t","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0005"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0006","chunkIndex":5,"heading":"REFERENCE DATA","headingPath":["LD-P RELAYS","REFERENCE DATA"],"preview":"REFERENCE DATA 1.Max. switching capacity Change of operate and release voltage Change of contact resistance 3 1.Operate time 2.Coil temperature characteristics (Average)","images":[{"path":"images/4c9eeb5ed60f8d10fc06ed01602f56567db63fdc4f232870f8e029b2054091d5.jpg","name":"4c9eeb5ed60f8d10fc06ed01602f56567db63fdc4f232870f8e029b2054091d5.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"AC resistive load contact rating graph","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F4c9eeb5ed60f8d10fc06ed01602f56567db63fdc4f232870f8e029b2054091d5.jpg"},{"path":"images/2e708d78ac7da579859d3d1aa3755d3d7b06f7bffa5b0bf0d95febbcdd3ca508.jpg","name":"2e708d78ac7da579859d3d1aa3755d3d7b06f7bffa5b0bf0d95febbcdd3ca508.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Temperature rise versus coil applied voltage","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F2e708d78ac7da579859d3d1aa3755d3d7b06f7bffa5b0bf0d95febbcdd3ca508.jpg"},{"path":"images/4212aff89662df24f45d1d367062f77cefef85c377962c0f70180a1a9b34d988.jpg","name":"4212aff89662df24f45d1d367062f77cefef85c377962c0f70180a1a9b34d988.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Operate time versus coil applied voltage","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F4212aff89662df24f45d1d367062f77cefef85c377962c0f70180a1a9b34d988.jpg"},{"path":"images/d9974c5c367fce40beb4f535996c64bb2d79f851a74007cad75eb3f4047ce7c1.jpg","name":"d9974c5c367fce40beb4f535996c64bb2d79f851a74007cad75eb3f4047ce7c1.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Release time versus coil applied voltage without diode","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Fd9974c5c367fce40beb4f535996c64bb2d79f851a74007cad75eb3f4047ce7c1.jpg"},{"path":"images/b90df7b1644727e3cd69ba9b39d4442c472765c5a157d5cef54b19c9f8f08129.jpg","name":"b90df7b1644727e3cd69ba9b39d4442c472765c5a157d5cef54b19c9f8f08129.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Release time versus coil applied voltage with diode","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Fb90df7b1644727e3cd69ba9b39d4442c472765c5a157d5cef54b19c9f8f08129.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0006"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0007","chunkIndex":6,"heading":"4.Electrical life test (5A 250 V AC Resistive load)","headingPath":["LD-P RELAYS","4.Electrical life test (5A 250 V AC Resistive load)"],"preview":"4.Electrical life test (5A 250 V AC Resistive load) DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. CAD LD P relay external dimensions, recommended PC board pattern (bottom view) and schemat","images":[{"path":"images/81c2f129788949ad9e6648755d34ffc6c3fc5b1cfa6e5caef60d2b80b90d525b.jpg","name":"81c2f129788949ad9e6648755d34ffc6c3fc5b1cfa6e5caef60d2b80b90d525b.jpg","mimeType":"image/jpeg","semanticKind":"schematic","semanticCaption":"Contact detection circuit test schematic","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F81c2f129788949ad9e6648755d34ffc6c3fc5b1cfa6e5caef60d2b80b90d525b.jpg"},{"path":"images/52b903b9db71d04b66e54bec8718aee17bab25519a44576a0b485f7f8dc77e8f.jpg","name":"52b903b9db71d04b66e54bec8718aee17bab25519a44576a0b485f7f8dc77e8f.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Operate and release voltage versus number of operations","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F52b903b9db71d04b66e54bec8718aee17bab25519a44576a0b485f7f8dc77e8f.jpg"},{"path":"images/f9f7e163f072729534bf5b191d0d7feb8f2c54e1ded5cdcae4ebe6194c1505fa.jpg","name":"f9f7e163f072729534bf5b191d0d7feb8f2c54e1ded5cdcae4ebe6194c1505fa.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Contact resistance versus number of operations","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Ff9f7e163f072729534bf5b191d0d7feb8f2c54e1ded5cdcae4ebe6194c1505fa.jpg"},{"path":"images/c86e9bed8a2d2c5bf4a306673df0a8e4b225d38ccfb6c83d72c22ef185910fb4.jpg","name":"c86e9bed8a2d2c5bf4a306673df0a8e4b225d38ccfb6c83d72c22ef185910fb4.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Relay package dimensions and recommended PCB pattern","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Fc86e9bed8a2d2c5bf4a306673df0a8e4b225d38ccfb6c83d72c22ef185910fb4.jpg"},{"path":"images/ldp-dimensions-page4.png","name":"ldp-dimensions-page4.png","mimeType":"image/png","semanticKind":"package_drawing","semanticCaption":"Package external dimensions and recommended PCB pattern","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2Fldp-dimensions-page4.png"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0007"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0008","chunkIndex":7,"heading":"DIMENSIONS","headingPath":["LD-P RELAYS","DIMENSIONS"],"preview":"| Terminal row from body side | 1.15 | Recommended PC board pattern (BOTTOM VIEW), tolerance ±0.1 | Item | Value | | | | | Holes | 4 x 1.1 dia. | | Coil terminal to inner contact terminal (along the row) | 11.5 | | Inner contact terminal to","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0008"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0009","chunkIndex":8,"heading":"SAFETY STANDARDS","headingPath":["LD-P RELAYS","SAFETY STANDARDS"],"preview":"SAFETY STANDARDS UL/C UL (Recognized)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0009"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0010","chunkIndex":9,"heading":"CSA (Certified)","headingPath":["LD-P RELAYS","CSA (Certified)"],"preview":"CSA (Certified) CSA standard certified by C UL CQC (Certified)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0010"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0011","chunkIndex":10,"heading":"GUIDELINES FOR USAGE","headingPath":["LD-P RELAYS","GUIDELINES FOR USAGE"],"preview":"GUIDELINES FOR USAGE For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions\\ use/index.jsp Cautions for usage of LD P relays Max. applied voltage and temperature rise Pro","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0011"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0012","chunkIndex":11,"heading":"GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE"],"preview":"GUIDELINES FOR POWER, HIGH CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions\\ use/index.jsp Precautions for Coil Input Lo","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0012"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0013","chunkIndex":12,"heading":"DC Coil operating power","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","DC Coil operating power"],"preview":"DC Coil operating power Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, please check with the actual circuit since the ele","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0013"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0014","chunkIndex":13,"heading":"Coil connection","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Coil connection"],"preview":"Coil connection When connecting coils of polarized relays, please check coil polarity (+, ) at the internal connection diagram (Schematic). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and s","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0014"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0015","chunkIndex":14,"heading":"Temperature/Humidity/Pressure","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Temperature/Humidity/Pressure"],"preview":"Temperature/Humidity/Pressure When transporting or storing relays while they are tube packaged, there are cases the temperature may difer from the allowable range. In this case be sure to check the individual specifications. Also allowable","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0015"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0016","chunkIndex":15,"heading":"1) Temperature:","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","1) Temperature:"],"preview":"1) Temperature: The tolerance temperature range difers for each relays, please refer to the relay’s individual specifications 2) Humidity: 5 to 85 % RH 3) Pressure: 86 to 106 kPa Ambient temperature（℃） Maximum allowable voltage and temperat","images":[{"path":"images/03ef6044e22a3606d7c9068906e889f19b08f19fa4426f292f6432b9534b0205.jpg","name":"03ef6044e22a3606d7c9068906e889f19b08f19fa4426f292f6432b9534b0205.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Allowable humidity range versus temperature","viewUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/asset?path=images%2F03ef6044e22a3606d7c9068906e889f19b08f19fa4426f292f6432b9534b0205.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0016"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0017","chunkIndex":16,"heading":"Operate voltage change due to coil temperature rise","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Operate voltage change due to coil temperature rise"],"preview":"Operate voltage change due to coil temperature rise In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the pick up voltage","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0017"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0018","chunkIndex":17,"heading":"Dew condensation","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Dew condensation"],"preview":"Dew condensation Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation caus","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0018"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0019","chunkIndex":18,"heading":"Icing","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Icing"],"preview":"Icing Condensation or other moisture may freeze on relays when the temperature become lower than 0°C.This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Corporation does n","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0019"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0020","chunkIndex":19,"heading":"Low temperature and low humidity","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Low temperature and low humidity"],"preview":"Low temperature and low humidity The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. High temperature and high humidity Storage for extended periods of time (includin","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0020"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0021","chunkIndex":20,"heading":"Package","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Package"],"preview":"Package In terms of the packing format used, make every efort to keep the efects of moisture, organic gases and sulfide gases to the absolute minimum. Silicon When a source of silicone substances (silicone rubber, silicone oil, silicone coa","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0021"},{"chunkId":"ds_24373168a56675dfdf73-chunk-0022","chunkIndex":21,"heading":"Others","headingPath":["GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE","Others"],"preview":"Others Cleaning • Although the environmentally sealed type relay (plastic sealed type, etc.) can be cleaned, avoid immersing the relay into cold liquid (such as cleaning solvent) immediately after soldering. Doing so may deteriorate the sea","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_24373168a56675dfdf73/chunks/ds_24373168a56675dfdf73-chunk-0022"}]}