{"datasheetId":"ds_467a5f02aa9901543fb8","chunkCount":139,"revision":"2026-11-09T20:06:20.872Z","source":"index","nextCursor":"49","chunks":[{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0001","chunkIndex":0,"heading":"Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D"],"preview":"Ebyte E22 T Series LoRa UART Module User Manual (EN), covering E22 900T22D Source: Chengdu Ebyte Electronic Technology Co., Ltd., E22 T User Manual (AT/HEX command generation, copyright 2012 2026), downloaded 2026 10 23 from the E22 900T22D","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0001"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0002","chunkIndex":1,"heading":"E22-900T22D drawing dimensions (transcribed from the page 10 figure, sec. 3.2)","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","E22-900T22D drawing dimensions (transcribed from the page 10 figure, sec. 3.2)"],"preview":"E22 900T22D drawing dimensions (transcribed from the page 10 figure, sec. 3.2) Unit mm; tolerance X.X +/ 0.2 mm, X.XX +/ 0.05 mm; pad quantity 10. | Feature | Value | | | | | Module PCB outline | 21.0 x 36.0 | | Side view overall depth (hea","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0002"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0003","chunkIndex":2,"heading":"Page 1","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 1"],"preview":"Page 1 E22 T User Manual page 1 figure 1 text E22 T Series Product Specifications AT Command 230/433/868/915MHz LoRa Wireless Module Page 2 ```text E22 T User Manual Disclaimer and Copyright Notice The information contained herein, includin","images":[{"path":"images/p-001-000.jpg","name":"p-001-000.jpg","mimeType":"image/jpeg","semanticKind":"logo","semanticCaption":"Ebyte company logo on a datasheet cover","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-001-000.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0003"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0004","chunkIndex":3,"heading":"Page 2","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 2"],"preview":"ry slightly. All trade names, trademarks and registered trademarks mentioned herein are the property of thei r respective owners. This product is strictly prohibited from being used in military applications and life safety related scenarios","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0004"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0005","chunkIndex":4,"heading":"Page 2","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 2"],"preview":"Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 1 Page 3 text E22 T User Manual Contents E22 T Series Product Specifications .................................................................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0005"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0006","chunkIndex":5,"heading":"Page 3","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 3"],"preview":"1.3 Application ................................................................................................................................................. 5 2 Specification.............................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0006"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0007","chunkIndex":6,"heading":"Page 3","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 3"],"preview":"3.3 E22 230/400/900T30S Mechanical Dimensions and Pin Definitions ......................................................10 3.4 E22 230/400/900T30D Mechanical Dimensions and Pin Definitions ...................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0007"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0008","chunkIndex":7,"heading":"Page 3","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 3"],"preview":"5.4 Serial Port Firmware Upgrade .................................................................................................................. 25 6 Register Read/Write Control ...........................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0008"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0009","chunkIndex":8,"heading":"Page 3","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 3"],"preview":"7.1 General Command ....................................................................................................................................32 7.2 Signaling Testing (Certification) ...............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0009"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0010","chunkIndex":9,"heading":"Page 4","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 4"],"preview":"Page 4 ```text E22 T User Manual 9 Common problems ...............................................................................................................................................................42 9.1 Unsatisfactory transmis","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0010"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0011","chunkIndex":10,"heading":"Page 4","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 4"],"preview":"10.1 Reflow temperature ................................................................................................................................ 44 10.2 Reflow temperature ............................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0011"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0012","chunkIndex":11,"heading":"Page 4","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 4"],"preview":"13.2 E22 230/400/900T22D(30D) Bulk Packaging Method ......................................................................... 48 13.3 E22 230/400/900T30S Bulk Packaging Method ................................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0012"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0013","chunkIndex":12,"heading":"Page 5","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 5"],"preview":"Page 5 E22 T User Manual page 5 figure 1 ```text E22 T User Manual 1 Introduction 1.1 Brief Introduction The E22 T series represents a new generation of LoRa wireless data transmission modules. This series of (UART) modules is developed bas","images":[{"path":"images/p-005-009.jpg","name":"p-005-009.jpg","mimeType":"image/jpeg","semanticKind":"photo","semanticCaption":"Photographs of E22-230T and E22-400T module variants","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-005-009.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0013"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0014","chunkIndex":13,"heading":"Page 5","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 5"],"preview":"The 12 modules shown below vary in power, package, and frequency band. Detailed specifications are provided in Section 2.1: E22 T Series Product Selection Comparison. 1.2 Features  Utilizes the latest generation LoRa spread spectrum modula","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0014"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0015","chunkIndex":14,"heading":"Page 6","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 6"],"preview":"Page 6 ```text E22 T User Manual operation of multiple networks within the same area;  Allows user defined communication keys that cannot be read, significantly enhancing data confidentiality;  Supports LBT (Listen Before Talk) functional","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0015"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0016","chunkIndex":15,"heading":"Page 6","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 6"],"preview":" Built in watchdog automatically resets and restores operation in case of unexpected events. 1.3 Application  Smart agricultural irrigation and environmental monitoring;  Photovoltaic power plant monitoring and distributed PV system mana","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0016"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0017","chunkIndex":16,"heading":"Page 6","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 6"],"preview":"①: Hz dBm km (mm) ④ IPEX 1/Stamp E22 230T22S 220～236M 22 5 SMD 16 26 Hole E22 220～236M 22 5 DIP 21 36 SMA K 230MHz 230T22D Module IPEX 1/Stamp E22 230T30S 220～236M 30 10 SMD 40.5 25 Hole E22 220～236M 30 10 DIP 43 24 SMA K 230T30D","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0017"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0018","chunkIndex":17,"heading":"Page 6","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 6"],"preview":"Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 5 Page 7 text E22 T User Manual Carrier Transmit Test Product Antenna Product Package Category frequency Power②: distance③: Dimensions Configuration Model Type ①: Hz dBm km (","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0018"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0019","chunkIndex":18,"heading":"Page 7","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 7"],"preview":"410～493M 22 5 DIP 21 36 SMA K Module 400T22D IPEX 1/Stamp E22 400T30S 410～493M 30 10 SMD 40.5 25 Hole E22 410～493M 30 10 DIP 43 24 SMA K 400T30D IPEX 1/Stamp E22 900T22S 850～930M 22 5 SMD 16 26 Hole E22 850～930M 22 5 DIP 21 36 SMA K","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0019"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0020","chunkIndex":19,"heading":"Page 7","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 7"],"preview":"868/915MHz 900T22D Module IPEX 1/Stamp E22 900T30S 850～930M 30 10 SMD 40.5 25 Hole E22 850～930M 30 10 DIP 43 24 SMA K 900T30D Note: (1) Carrier Frequency ①: Frequency band range supports user customization; (2) Transmit Power ②: 22dBm = 158","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0020"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0021","chunkIndex":20,"heading":"Page 7","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 7"],"preview":" E22 T Series 22dBm Low Power Module Models: E22 230T22D, E22 230T22S, E22 400T22D, E22 400T22S, E22 900T22D, E22 900T22S;  E22 T Series 30dBm high power module models: E22 230T30D, E22 230T30S, E22 400T30D, E22 400T30S, E22 900T30D, E22","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0021"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0022","chunkIndex":21,"heading":"Page 8","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 8"],"preview":"Page 8 ```text E22 T User Manual Parameters Description Transmission Header pins: through hole module Length Package Type UART serial port (3.3V) Buffer 240 bytes maximum per packet; automatically segments packets exceeding this limit. Adju","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0022"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0023","chunkIndex":22,"heading":"Page 8","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 8"],"preview":"30dBm = 1000mW, multi level power adjustable. Details in Sections 6 and 7 of this document. Operating 220MHz–236MHz, supports custom frequency bands. Frequency 410MHz–493MHz, supports custom frequency bands. Band Receiver 850MHz–930MHz, sup","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0023"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0024","chunkIndex":23,"heading":"Page 8","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 8"],"preview":"Supply 2.6–5.5V, 30dBm output module ≥5V, 22dBm output module ≥3.3V ensures output power; exceeding Voltage 5.5V will permanently damage the module. Communicati 3.3V on Level 100–140mA, instantaneous power consumption @22dBm, suitable for E","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0024"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0025","chunkIndex":24,"heading":"Page 9","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 9"],"preview":"Page 9 E22 230/400/900T22S mechanical drawing (sec. 3.1) ```text E22 T User Manual 3 Mechanical Dimensions and Pin Definitions 3.1 E22 230/400/900T22S Mechanical Dimensions and Pin Definitions No Name Pin orientation Pin Function 1.Module r","images":[{"path":"images/p-009-018.jpg","name":"p-009-018.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Mechanical package drawing for a 26-pad module","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-009-018.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0025"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0026","chunkIndex":25,"heading":"Page 9","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 9"],"preview":"5 NC Unused Pin (Leave Unconnected) Empty pins (programming pins; if possible, bring them out for easier 6 NC maintenance or firmware customization) Empty pins (programming pins; if possible, bring them out for easier 7 NC maintenance or fi","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0026"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0027","chunkIndex":26,"heading":"Page 9","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 9"],"preview":"15 GND Module Ground Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 8 Page 10 E22 230/400/900T22D mechanical drawing (sec. 3.2): 21.0 x 36.0 mm, 7 header pins at 2.54 mm, fixed holes 8 10, SMA K text E22 T User Manual No","images":[{"path":"images/p-010-021.jpg","name":"p-010-021.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Mechanical package drawing for a 10-pad module with antenna connector","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-010-021.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0027"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0028","chunkIndex":27,"heading":"Page 10","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 10"],"preview":"22 RXD Input 3.3V serial input, connected to external TXD output pin; 23 TXD Output 3.3V serial output, connected to external RXD output pin; 1. Indicates module operational status (may be left floating); 2. During normal operation, a low l","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0028"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0029","chunkIndex":28,"heading":"Page 10","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 10"],"preview":"Section 5. 25 VCC Module Power Supply (Refer to the Electrical Parameters section) 26 GND Module Ground 3.2 E22 230/400/900T22D Mechanical Dimensions and Pin Definitions Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 9 ``","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0029"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0030","chunkIndex":29,"heading":"Page 11","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 11"],"preview":"Page 11 E22 230/400/900T30S mechanical drawing (sec. 3.3) ```text E22 T User Manual No Name Pin orientation Pin Function Input (Very Weak When paired with M1, it determines the module's four operating modes 1 M0 Pull Up) (cannot be left flo","images":[{"path":"images/p-011-024.jpg","name":"p-011-024.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Mechanical package drawing for a 24-pad module","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-011-024.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0030"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0031","chunkIndex":30,"heading":"Page 11","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 11"],"preview":"2. During normal operation, a low level on this pin indicates busy status, while a high level indicates idle status; 3. It is not recommended to use this pin to drive external devices or pull it 5 AUX Output low. Otherwise, if the AUX pin i","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0031"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0032","chunkIndex":31,"heading":"Page 11","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 11"],"preview":"9 Fixed hole Fixed hole 10 Fixed hole Fixed hole 3.3 E22 230/400/900T30S Mechanical Dimensions and Pin Definitions Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 10 Page 12 text E22 T User Manual No Name Pin orientation P","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0032"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0033","chunkIndex":32,"heading":"Page 12","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 12"],"preview":"3. It is not recommended to use this pin to drive external devices or pull it 3 AUX Output low. Otherwise, if the AUX pin is continuously pulled low by an external source during module power up, the module may forcibly enter upgrade mode an","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0033"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0034","chunkIndex":33,"heading":"Page 12","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 12"],"preview":"7 M0 Weak Pull Up) (cannot be left floating) Antenna interface (high frequency signal output, 50 ohm characteristic 11 ANT Output impedance) 12 GND Fixed location 13 GND Fixed location 14 GND Fixed location Empty pin (programming pin; if po","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0034"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0035","chunkIndex":34,"heading":"Page 12","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 12"],"preview":"21 NC Empty pin (leave it open) 1.Module reset pin. Low level trigger for reset, requiring a pull down time exceeding 100μs; 22 RESET Input 2.Users are strongly advised to connect to a microcontroller for reset and recovery in unexpected si","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0035"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0036","chunkIndex":35,"heading":"Page 13","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 13"],"preview":"Page 13 E22 230/400/900T30D mechanical drawing (sec. 3.4) ```text E22 T User Manual 3.4 E22 230/400/900T30D Mechanical Dimensions and Pin Definitions No Name Pin orientation Pin Function Input (Very When used with M1, determines the module'","images":[{"path":"images/p-013-029.jpg","name":"p-013-029.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"Mechanical package drawing for an 11-pad module with antenna connector","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-013-029.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0036"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0037","chunkIndex":36,"heading":"Page 13","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 13"],"preview":"1. Indicates module operational status (may be left floating); 2. During normal operation, a low level on this pin indicates busy status, while a high level indicates idle status; 3. It is not recommended to use this pin to drive external d","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0037"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0038","chunkIndex":37,"heading":"Page 13","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 13"],"preview":"8 Fixed hole Mounting Hole 9 Fixed hole Mounting Hole 10 Fixed hole Mounting Hole 11 Fixed hole Mounting Hole Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 12 Page 14 Recommended connection diagram, generic E22 xxxTxxx (","images":[{"path":"images/p-014-032.jpg","name":"p-014-032.jpg","mimeType":"image/jpeg","semanticKind":"schematic","semanticCaption":"E22-xxxTxxx module connected to an MCU with UART and control signals","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-014-032.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0038"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0039","chunkIndex":38,"heading":"Page 14","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 14"],"preview":"microcontroller's serial port. Failure to do so may prevent module shutdown. Avoid using the AUX pin to drive external components (e.g., LEDs, relays). Continuous external pull down 4 during power on will cause malfunction. (Optional) For s","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0039"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0040","chunkIndex":39,"heading":"Page 15","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 15"],"preview":"Page 15 E22 T User Manual page 15 figure 1 ```text E22 T User Manual 5.1 Working Mode The module has four operating modes, set via pins M1 and M0, as detailed in the table below: Mode（0 3） M1 M0 Model Introduction Remarks 0 Serial port enab","images":[{"path":"images/p-015-035.jpg","name":"p-015-035.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Dual XCOM V2.6 serial terminal software screenshots","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-015-035.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0040"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0041","chunkIndex":40,"heading":"Page 15","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 15"],"preview":"3 Deep Sleep 1 1 Module enters sleep mode 5.1.1 Transmission mode in use: Mode 0 (M1 and M0 pins set to 0,0) 5.1.1.1 Quick Start Guide for Transparent Transfer What you see is what you get. Simply use Serial Port Assistant for mutual commun","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0041"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0042","chunkIndex":41,"heading":"Page 16","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 16"],"preview":"Page 16 E22 T User Manual page 16 figure 1 E22 T User Manual page 16 figure 2 text E22 T User Manual Figure 2 Point to Point Transmission Schematic Operating Procedure: Step 1: Modify module parameters via the host computer: In configuratio","images":[{"path":"images/p-016-038.jpg","name":"p-016-038.jpg","mimeType":"image/jpeg","semanticKind":"flow_diagram","semanticCaption":"Address and channel filtering for wireless module packets","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-016-038.jpg"},{"path":"images/p-016-039.jpg","name":"p-016-039.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Ebyte RF Setting configuration software screenshots","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-016-039.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0042"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0043","chunkIndex":42,"heading":"Page 17","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 17"],"preview":"Page 17 E22 T User Manual page 17 figure 1 E22 T User Manual page 17 figure 2 ```text E22 T User Manual Figure 4 Data Transmission Diagram 5.1.1.3 Quick Guide to Broadcasting  Set Module A's address to 0xFFFF and channel to 0x04. When Modu","images":[{"path":"images/p-017-042.jpg","name":"p-017-042.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Dual XCOM serial terminal showing addressed packet transmission and reception","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-017-042.jpg"},{"path":"images/p-017-043.jpg","name":"p-017-043.jpg","mimeType":"image/jpeg","semanticKind":"flow_diagram","semanticCaption":"Broadcast packet delivery to modules on matching channels","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-017-043.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0043"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0044","chunkIndex":43,"heading":"Page 17","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 17"],"preview":"mode from transparent to fixed point transmission. Finally, write the parameters to complete the modification. Copyright ©2012–2026，Chengdu Ebyte Electronic Technology Co.,Ltd. 16 Page 18 E22 T User Manual page 18 figure 1 E22 T User Manual","images":[{"path":"images/p-018-046.jpg","name":"p-018-046.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Ebyte RF_Setting configuration screenshots showing fixed transmission mode and address/channel settings.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-018-046.jpg"},{"path":"images/p-018-047.jpg","name":"p-018-047.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"XCOM serial-terminal screenshots showing hexadecimal transmit and receive data.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-018-047.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0044"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0045","chunkIndex":44,"heading":"Page 18","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 18"],"preview":"Step 1: Modify module parameters via the host computer: In configuration mode (with M1 and M0 pins set to 1 and 0 respectively), modify the module's WOR role and write the parameters to complete the modification. Copyright ©2012–2026，Chengd","images":[{"path":"images/p-019-050.jpg","name":"p-019-050.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Ebyte RF_Setting screenshots showing transmitter and receiver WOR roles.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-019-050.jpg"},{"path":"images/p-019-051.jpg","name":"p-019-051.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"XCOM serial-terminal screenshots showing repeated EBYTE transmission and reception.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-019-051.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0045"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0046","chunkIndex":45,"heading":"Page 19","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 19"],"preview":"The figure below shows the configuration interface for the host computer. Users can switch to command mode using M0 or M1 to quickly configure and read parameters on the host computer. Copyright ©2012–2026，Chengdu Ebyte Electronic Technolog","images":[{"path":"images/p-020-055.jpg","name":"p-020-055.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Ebyte RF_Setting configuration window for an E22 module.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-020-055.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0046"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0047","chunkIndex":46,"heading":"Page 20","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 20"],"preview":"base when entered. For example, if the network ID entered at transmitter A is 02 and the network ID entered at receiver B is 10, then when configuring the module address for repeater R, convert the hexadecimal value 0x020A to the decimal va","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0047"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0048","chunkIndex":47,"heading":"Page 21","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 21"],"preview":"Page 21 E22 T User Manual page 21 figure 1 E22 T User Manual page 21 figure 2 E22 T User Manual page 21 figure 3 text E22 T User Manual Figure 11: Host Computer Interface Diagram Step 2: Modify parameters remotely and perform parameter writ","images":[{"path":"images/p-021-059.jpg","name":"p-021-059.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Ebyte RF_Setting screenshots showing local and remote module configuration.","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-021-059.jpg"},{"path":"images/p-021-060.jpg","name":"p-021-060.jpg","mimeType":"image/jpeg","semanticKind":"text_snippet","semanticCaption":"RF Setting configuration software showing module parameters","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-021-060.jpg"},{"path":"images/p-021-061.jpg","name":"p-021-061.jpg","mimeType":"image/jpeg","semanticKind":"text_snippet","semanticCaption":"RF Setting software showing local and remote module configurations","viewUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/asset?path=images%2Fp-021-061.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0048"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0049","chunkIndex":48,"heading":"Page 22","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 22"],"preview":"Page 22 ```text E22 T User Manual 5.1.4 Sleep Mode Usage, Mode 3 (M1, M0 pins set to 1,1)  To activate sleep mode, simply set the M1 and M0 pins to a high level. The module will then enter sleep mode with minimal power consumption. 5.2 AUX","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0049"},{"chunkId":"ds_467a5f02aa9901543fb8-chunk-0050","chunkIndex":49,"heading":"Page 22","headingPath":["Ebyte E22-T Series LoRa UART Module User Manual (EN), covering E22-900T22D","Page 22"],"preview":"T2 Note: During the initial phase of T2, the AUX pin operates in internal pull up input 5 ms mode. If it detects an externally applied low signal lasting over 1 second (e.g., due to an external pull down resistor or shorting to GND), it wil","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_467a5f02aa9901543fb8/chunks/ds_467a5f02aa9901543fb8-chunk-0050"}]}