{"datasheetId":"ds_52874c53808948ad8f25","chunkCount":178,"revision":"2026-11-09T20:11:14.248Z","source":"index","nextCursor":"49","chunks":[{"chunkId":"ds_52874c53808948ad8f25-chunk-0001","chunkIndex":0,"heading":"Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)"],"preview":"Bosch Sensortec BMP390 datasheet (BST BMP390 DS002 07, revision 1.7, March 2021) Source: https://www.bosch sensortec.com/media/boschsensortec/downloads/datasheets/bst bmp390 ds002.pdf (59 pages, SHA 256 8dcf0f74449cb1627e865c7f24d328b76c204","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0001"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0002","chunkIndex":1,"heading":"Page 1","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 1"],"preview":"Page 1 text Bosch Sensortec | BMP390 Datasheet 1 | 59 BMP390 Digital pressure sensor BMP390 – Datasheet Document revision 1.7 Document release date March 2021 Document number BST BMP390 DS002 07 Technical reference code(s) 0 273 017 014 Not","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0002"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0003","chunkIndex":2,"heading":"Page 2","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 2"],"preview":"Page 2 ```text Bosch Sensortec | BMP390 Datasheet 2 | 59 BMP390 Digital pressure sensor The BMP390 is a digital sensor with pressure and temperature measurement based on proven sensing principles. The sensor module is housed in an extremely","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0003"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0004","chunkIndex":3,"heading":"Page 2","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 2"],"preview":"• AR & VR applications • Context awareness Target Devices • Flying toys • Drones • Handsets such as mobile phones, tablet PCs, GPS devices • Navigation systems • Portable health care devices • Home weather stations • Watches • White goods P","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0004"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0005","chunkIndex":4,"heading":"Page 3","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 3"],"preview":"VDDIO interface voltage range: 1.2 V to 3.6 V typ. ± 3 Pa, equiv. to ± 0.25 m Relative accuracy (700 … 1100 hPa, 25 . . . 40 °C ) typ. ± 50 Pa Absolute accuracy (300 ...1100 hPa, 0 ...+65 °C) mean value ± 0.6 Pa/K Temperature coefficient of","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0005"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0006","chunkIndex":5,"heading":"Page 3","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 3"],"preview":"1.4 µA in sleep mode Operating range 40 ‒ +85 °C, 300‒1250 hPa The product is RoHS compliant, halogen free, MSL1 BMP390 enables accurate altitude tracking and is specifically suited for mobile applications. The best in class TCO between 20","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0006"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0007","chunkIndex":6,"heading":"Page 3","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 3"],"preview":"It is available in a compact 10 in 2.0 x 2.0 x 0.75 mm³ LGA package with metal lid Due to the built in hardware synchronization of the pressure sensor data and its ability to synchronize data from external devices such as acceleration senso","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0007"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0008","chunkIndex":7,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"Page 4 ```text Bosch Sensortec | BMP390 Datasheet 4 | 59 Table of Contents 1. Specification.....................................................................................................................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0008"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0009","chunkIndex":8,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.2. Power management ............................................................................................................................................. 11 3.3. Power modes ........................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0009"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0010","chunkIndex":9,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.4. Measurement flow ...............................................................................................................................................13 3.4.1. Pressure measurement ............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0010"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0011","chunkIndex":10,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.6. FIFO Description ..................................................................................................................................................18 3.6.1. FIFO input data ..............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0011"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0012","chunkIndex":11,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.6.7. FIFO flush conditions ......................................................................................................................................21 3.7. Interrupts ..........................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0012"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0013","chunkIndex":12,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.7.5. Interrupt functions ...........................................................................................................................................23 3.8. Current consumption ..............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0013"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0014","chunkIndex":13,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"3.11. Output compensation ......................................................................................................................................28 3.11.1. Memory Map Trimming Coefficients.....................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0014"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0015","chunkIndex":14,"heading":"Page 4","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 4"],"preview":"4.3.2. Register 0x01 “REV ID” .................................................................................................................................31 4.3.3. Register 0x02 “ERR REG” ...............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0015"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0016","chunkIndex":15,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"Page 5 ```text Bosch Sensortec | BMP390 Datasheet 5 | 59 4.3.9. Register 0x11 “INT STATUS” .........................................................................................................................33 4.3.10. Register 0x12 ..","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0016"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0017","chunkIndex":16,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"4.3.14. Register 0x18 “FIFO CONFIG 2” ..................................................................................................................35 4.3.15. Register 0x19 “INT CTRL” ....................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0017"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0018","chunkIndex":17,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"4.3.20. Control settings for odr sel .............................................................................................................................38 4.3.21. Register 0x1F “CONFIG” ............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0018"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0019","chunkIndex":18,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"5.2. I²C Interface ..........................................................................................................................................................40 5.2.1. I²C write ...............................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0019"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0020","chunkIndex":19,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"5.4. Interface parameter specification .......................................................................................................................43 5.4.1. General interface parameters ...........................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0020"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0021","chunkIndex":20,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"6.2. Connection diagram ¾ wire SPI .........................................................................................................................47 6.3. Connection diagram I²C .....................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0021"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0022","chunkIndex":21,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"7.3.1. Mass production samples ...............................................................................................................................50 7.3.2. Engineering samples ....................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0022"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0023","chunkIndex":22,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"7.7. Environmental safety ..........................................................................................................................................53 7.7.1. RoHS .............................................................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0023"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0024","chunkIndex":23,"heading":"Page 5","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 5"],"preview":"8.2. Product use ..........................................................................................................................................................54 8.3. Application examples and hints ..............................","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0024"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0025","chunkIndex":24,"heading":"Page 6","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 6"],"preview":"Page 6 text Bosch Sensortec | BMP390 Datasheet 6 | 59 8.4. Calibration coefficient .........................................................................................................................................55 8.5. Temperature","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0025"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0026","chunkIndex":25,"heading":"Page 7","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 7"],"preview":"Page 7 ```text Bosch Sensortec | BMP390 Datasheet 7 | 59 1. Specification If not stated otherwise, • All values are valid over the full voltage range • All minimum/maximum values are given for the full accuracy temperature range • Minimum/m","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0026"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0027","chunkIndex":26,"heading":"Page 7","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 7"],"preview":"Parameter Symbol Condition Min Typ Max Unit operational 40 25 +85 Operating TA °C temperature range full accuracy 0 +65 Operating pressure P full accuracy 300 1250 hPa range Sensor supply VDD ripple max. 50mVpp 1.65 1.8 3.6 V voltage Interf","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0027"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0028","chunkIndex":27,"heading":"Page 7","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 7"],"preview":"IDDSL VDD = VDDIO = 1.8 V 1.4 µA Sleep current IDDSL VDD = VDDIO = 3.6 V 1.5 µA during pressure Peak current Ipeak 660 730 µA measurement during temperature Peak current IDDT 240 320 µA measurement 700 . . . 1100 hPa ±0.03 hPa Relative accu","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0028"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0029","chunkIndex":28,"heading":"Page 7","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 7"],"preview":"Arel cm pressure 1 10 kPa steps +/ 25 cm Offset temperature 900 hPa TCO ±0.62 Pa/K coefficient 2 25 . . . 40 °C 900 hPa Absolute accuracy APfull 25 °C ±0.33 hPa 1 Per 10kPa steps 2 Mean value ```","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0029"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0030","chunkIndex":29,"heading":"Page 8","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 8"],"preview":"Page 8 ```text Bosch Sensortec | BMP390 Datasheet 8 | 59 pressure 300. . . 1100 hPa APfull 0 . . . 65 °C ±0.50 hPa 900. . . 1100 hPa APext 25 . . . 40 °C ±0.40 hPa 1100. . . 1250 hPa AP ±0.50 hPa 0. . . 65 °C 300. . . 1100 hPa AP ±0.50 hPa","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0030"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0031","chunkIndex":30,"heading":"Page 8","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 8"],"preview":"20 °C Resolution of output data in highest resolution RP Pressure 0.016 Pa mode at lowest bandwidth Vp,full 25 Hz ODR, 32xOSR P & 0.9 Pa 2xOSR T RMS Noise in pressure Vp,filtered Lowest bandwidth, highest 0.02 Pa resolution See chapter 3.4.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0031"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0032","chunkIndex":31,"heading":"Page 8","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 8"],"preview":"Long term stability 4 ∆Pstab 12 months ±0.16 hPa Minimum solder height 50","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0032"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0033","chunkIndex":32,"heading":"Page 8","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 8"],"preview":"stand by mode 3 Temperature measured by the internal temperature sensor. This temperature value depends on the PCB temperature, sensor element self heating and ambient temperature and is typically above ambient temperature. 4 Long term stab","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0033"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0034","chunkIndex":33,"heading":"Page 9","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 9"],"preview":"Voltage at any interface pin Vss 0.3 VDDIO + 0.3 V Storage temperature ≤ 65% rel. H. 45 +85 °C Overpressure survivability POVER 2 000 000 Pa Mechanical shock MS MIL STD 883H 20.000 g 2002.5 Maximum allowable dust particle DustMAX ISO 12103","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0034"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0035","chunkIndex":34,"heading":"Page 9","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 9"],"preview":"(CDM) 500V to ESD","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0035"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0036","chunkIndex":35,"heading":"Page 9","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 9"],"preview":"BMP390 can be operated in three power modes (see section 3.3): sleep mode | normal mode | forced mode In sleep mode, no measurements are performed. Normal mode comprises an automated perpetual cycling between an active measurement period an","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0036"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0037","chunkIndex":36,"heading":"Page 10","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 10"],"preview":"Page 10 BMP390 datasheet page 10: Figure 1: Block Diagram BMP390 ```text Bosch Sensortec | BMP390 Datasheet 10 | 59 A set of oversampling settings is available ranging from ultra low power to highest resolution setting in order to adapt the","images":[{"path":"images/bmp390-ds-page-10.png","name":"bmp390-ds-page-10.png","mimeType":"image/png","semanticKind":"block_diagram","semanticCaption":"BMP390 simplified block diagram","viewUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/asset?path=images%2Fbmp390-ds-page-10.png"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0037"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0038","chunkIndex":37,"heading":"Page 10","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 10"],"preview":"Figure 1: Block Diagram BMP390 Page 11 text Bosch Sensortec | BMP390 Datasheet 11 | 59 3.2. Power management The BMP390 has two separate power supply pins • VDD is the main power supply for all internal analog and digital regulator blocks.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0038"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0039","chunkIndex":38,"heading":"Page 11","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 11"],"preview":"Table 4: mode settings Parameter Symbol Min. Max. Unit Test 7 VDDA power on Vpor vdda 1.35 1.6 V T rising edge VDDA power on hysteresis Vpor hyst vdda 75 mV T VDDD power on Vpor vddd 2.7 1.08 V Q rising edge VDDD power on Vpor hyst vddd 200","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0039"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0040","chunkIndex":39,"heading":"Page 11","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 11"],"preview":"The BMP390 offers three power modes: sleep mode, forced mode and normal mode. These can be selected using the mode[1:0] bits in control register “pwr ctrl”. Table 5: mode settings mode[1:0] Mode 00 Sleep mode 01 and 10 Forced mode 11 Normal","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0040"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0041","chunkIndex":40,"heading":"Page 11","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 11"],"preview":"registers. For a next measurement, forced mode needs to be selected again. Forced mode is recommended for applications which require low sampling rate or host based synchronization. 7 T: directly or indirectly tested at 100% at room tempera","images":[{"path":"images/bmp390-ds-page-12.png","name":"bmp390-ds-page-12.png","mimeType":"image/png","semanticKind":"timing_diagram","semanticCaption":"BMP390 force mode and normal mode timing diagrams","viewUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/asset?path=images%2Fbmp390-ds-page-12.png"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0041"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0042","chunkIndex":41,"heading":"Page 12","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 12"],"preview":"Measurement P Measurement P Measurement P Measurement P Measurement T Measurement T Measurement T Measurement T IIDLE ISLEEP","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0042"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0043","chunkIndex":42,"heading":"Page 12","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 12"],"preview":"Write time POR settings Mode[1:0] = 01 Data readout Mode[1:0] = 01 Figure 2: Force mode timing diagram 3.3.3. Normal mode Normal mode continuously cycles between an (active) measurement period and an (inactive) standby period. The measureme","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0043"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0044","chunkIndex":43,"heading":"Page 12","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 12"],"preview":"in which short term disturbances (e.g. blowing into the sensor) should be filtered. τsampling current osrs p osrs t IMEAS, P IMEAS, T Measurement P Measurement P Measurement P Measurement P Measurement P Measurement P Measurement P","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0044"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0045","chunkIndex":44,"heading":"Page 12","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 12"],"preview":"Measurement P Measurement T Measurement T Measurement T Measurement T IIDLE ISLEEP Write time POR settings Mode[1:0] = 11 Data readout when needed Figure 3: Normal mode timing diagram ```","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0045"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0046","chunkIndex":45,"heading":"Page 13","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 13"],"preview":"Page 13 BMP390 datasheet page 13: Figure 4: Mode transition diagram; Figure 5: BMP390 measurement cycle ```text Bosch Sensortec | BMP390 Datasheet 13 | 59 3.3.4. Mode transition diagram The supported mode transitions are displayed below. If","images":[{"path":"images/bmp390-ds-page-13.png","name":"bmp390-ds-page-13.png","mimeType":"image/png","semanticKind":"flow_diagram","semanticCaption":"BMP390 mode transition and measurement flow diagrams","viewUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/asset?path=images%2Fbmp390-ds-page-13.png"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0046"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0047","chunkIndex":46,"heading":"Page 13","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 13"],"preview":"VDDA and V DDD measurement periods) supplied Sleep Forced (one measurement period) Figure 4: Mode transition diagram 3.4. Measurement flow The BMP390 measurement period consists of a temperature and pressure measurement with selectable over","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0047"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0048","chunkIndex":47,"heading":"Page 13","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 13"],"preview":"measurement cycle Measure pressure (oversampling set by osrs p; IIR filter enabled? No skip if press en = 0) Yes Measure temperature Copy ADC values (oversampling set by osrs t; IIR filter initialised? No to filter memory skip if temp en =","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0048"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0049","chunkIndex":48,"heading":"Page 13","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 13"],"preview":"filter memory, ADC value to output registers, and filter coefficient send filter memory to FIFO End measurement cycle Figure 5: BMP390 measurement cycle The individual blocks of the diagram above will be detailed in the following subsection","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0049"},{"chunkId":"ds_52874c53808948ad8f25-chunk-0050","chunkIndex":49,"heading":"Page 14","headingPath":["Bosch Sensortec BMP390 datasheet (BST-BMP390-DS002-07, revision 1.7, March 2021)","Page 14"],"preview":"Page 14 ```text Bosch Sensortec | BMP390 Datasheet 14 | 59 3.4.1. Pressure measurement Pressure measurement can be enabled or skipped. Skipping the measurement could be useful if BMP390 is used as temperature sensor. When enabled, several o","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_52874c53808948ad8f25/chunks/ds_52874c53808948ad8f25-chunk-0050"}]}