{"datasheetId":"ds_5ab2bfb8b25d33b977bb","chunkCount":111,"revision":"2026-11-09T20:01:22.164Z","source":"index","nextCursor":"49","chunks":[{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0001","chunkIndex":0,"heading":"INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface"],"preview":"INA219 Zerø Drift, Bidirectional Current/Power Monitor With I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0001"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0002","chunkIndex":1,"heading":"3 Description","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","3 Description"],"preview":"3 Description The INA219 is a current shunt and power monitor with an I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0002"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0003","chunkIndex":2,"heading":"3 Description","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","3 Description"],"preview":"Simplified Schematic Table of Contents 1 Features.... 1 2 Applications.... 1 3 Description.... 1 4 Revision History.... 2 5 Related Products.... 3 6 Pin Configuration and Functions.... 3 7 Specifications.... 4 7.1 Absolute Maximum Ratings..","images":[{"path":"images/964a110669698b5fcb7a14e92c6f2906f2ea959ac90895fe0cb9974699b0e5cf.jpg","name":"964a110669698b5fcb7a14e92c6f2906f2ea959ac90895fe0cb9974699b0e5cf.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F964a110669698b5fcb7a14e92c6f2906f2ea959ac90895fe0cb9974699b0e5cf.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0003"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0004","chunkIndex":3,"heading":"4 Revision History","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","4 Revision History"],"preview":"4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Revision F (September 2011) to Revision G Page Added ESD Ratings table, Feature Description section, Device Funct","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0004"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0005","chunkIndex":4,"heading":"5 Related Products","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","5 Related Products"],"preview":"5 Related Products","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0005"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0006","chunkIndex":5,"heading":"6 Pin Configuration and Functions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","6 Pin Configuration and Functions"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0006"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0007","chunkIndex":6,"heading":"7 Specifications","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7 Specifications"],"preview":"7 Specifications 7.1 Absolute Maximum Ratings over operating free air temperature range (unless otherwise noted)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0007"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0008","chunkIndex":7,"heading":"7.1 Absolute Maximum Ratings","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.1 Absolute Maximum Ratings"],"preview":"(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those ind","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0008"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0009","chunkIndex":8,"heading":"7.2 ESD Ratings","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.2 ESD Ratings"],"preview":"7.2 ESD Ratings","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0009"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0010","chunkIndex":9,"heading":"7.3 Recommended Operating Conditions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.3 Recommended Operating Conditions"],"preview":"7.3 Recommended Operating Conditions over operating free air temperature range (unless otherwise noted)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0010"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0011","chunkIndex":10,"heading":"7.4 Thermal Information","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.4 Thermal Information"],"preview":"(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. 7.5 Electrical Characteristics:","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0011"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0012","chunkIndex":11,"heading":"7.4 Thermal Information","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.4 Thermal Information"],"preview":"(1) BRNG is bit 13 of the Configuration register 00h in Figure 19. (2) This parameter only expresses the full scale range of the ADC scaling. In no event should more than 26 V be applied to this device. (3) Referred to input (RTI) (4) Indic","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0012"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0013","chunkIndex":12,"heading":"Electrical Characteristics: (continued)","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Electrical Characteristics: (continued)"],"preview":"Electrical Characteristics: (continued) $\\mathsf { A t } \\mathsf { T } { \\mathsf { A } } = 2 5 ^ { \\circ } \\mathsf { C }$ , V = 3.3 V, $\\mathsf { V } { | \\mathsf { N } + } = 1 2 \\mathsf { V } ,$ $\\mathsf { V } { \\mathsf { S H U N T } } = (","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0013"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0014","chunkIndex":13,"heading":"Electrical Characteristics: (continued)","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Electrical Characteristics: (continued)"],"preview":"7.6 Bus Timing Diagram Definitions","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0014"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0015","chunkIndex":14,"heading":"7.6 Bus Timing Diagram Definitions<sup>(1)</sup>","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.6 Bus Timing Diagram Definitions<sup>(1)</sup>"],"preview":"(1) Values based on a statistical analysis of a one time sample of devices. Minimum and maximum values are not ensured and not production tested. Figure 1. Bus Timing Diagram 7.7 Typical Characteristics $\\mathsf { A t } \\mathsf { T } { \\mat","images":[{"path":"images/3f75705e265fd2cbbcc92c6d98f9cf9f4633c072a126a257489e8cc7396a8dff.jpg","name":"3f75705e265fd2cbbcc92c6d98f9cf9f4633c072a126a257489e8cc7396a8dff.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F3f75705e265fd2cbbcc92c6d98f9cf9f4633c072a126a257489e8cc7396a8dff.jpg"},{"path":"images/9083fb31dd0c81e8a20a1712b3be1947e712b147b042983f1d2189f9af98b976.jpg","name":"9083fb31dd0c81e8a20a1712b3be1947e712b147b042983f1d2189f9af98b976.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F9083fb31dd0c81e8a20a1712b3be1947e712b147b042983f1d2189f9af98b976.jpg"},{"path":"images/18be7e134b699663dbd68e260091cc9b727ea73f28d387dc87251fd27540ce68.jpg","name":"18be7e134b699663dbd68e260091cc9b727ea73f28d387dc87251fd27540ce68.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F18be7e134b699663dbd68e260091cc9b727ea73f28d387dc87251fd27540ce68.jpg"},{"path":"images/4d5019e63b68c49f153a3a1f56526091b37150cc14edac4bfb0b0f0279f98c72.jpg","name":"4d5019e63b68c49f153a3a1f56526091b37150cc14edac4bfb0b0f0279f98c72.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F4d5019e63b68c49f153a3a1f56526091b37150cc14edac4bfb0b0f0279f98c72.jpg"},{"path":"images/e9bac39d567968ca55068f93c7a41cd9083111007fae7388a236edfb2135c707.jpg","name":"e9bac39d567968ca55068f93c7a41cd9083111007fae7388a236edfb2135c707.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Fe9bac39d567968ca55068f93c7a41cd9083111007fae7388a236edfb2135c707.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0015"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0016","chunkIndex":15,"heading":"7.7 Typical Characteristics","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","7.7 Typical Characteristics"],"preview":"Figure 4. ADC Shunt Gain Error vs Temperature Figure 6. ADC Bus Gain Error vs Temperature Figure 5. ADC Bus Voltage Offset vs Temperature Figure 7. Integral Nonlinearity vs Input Voltage Typical Characteristics (continued) $\\mathrm { a } {","images":[{"path":"images/b644ab16305922819d66a3eff920ad11117a28070569c86dcb4015dc622aebe4.jpg","name":"b644ab16305922819d66a3eff920ad11117a28070569c86dcb4015dc622aebe4.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Fb644ab16305922819d66a3eff920ad11117a28070569c86dcb4015dc622aebe4.jpg"},{"path":"images/bd330b1b1aeed4f9e0a7b462a1736ef2eb1ba650f647aa2fb8b5c541745e19cf.jpg","name":"bd330b1b1aeed4f9e0a7b462a1736ef2eb1ba650f647aa2fb8b5c541745e19cf.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Fbd330b1b1aeed4f9e0a7b462a1736ef2eb1ba650f647aa2fb8b5c541745e19cf.jpg"},{"path":"images/1b2501d2d5d91399fcbed2eb114d4b8128358acc5ce9c8863dcd344546504c6f.jpg","name":"1b2501d2d5d91399fcbed2eb114d4b8128358acc5ce9c8863dcd344546504c6f.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F1b2501d2d5d91399fcbed2eb114d4b8128358acc5ce9c8863dcd344546504c6f.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0016"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0017","chunkIndex":16,"heading":"Typical Characteristics (continued)","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Typical Characteristics (continued)"],"preview":"Figure 9. Active $\\mathsf { I } { \\mathsf { Q } }$ vs Temperature Figure 10. Shutdown $\\mathsf { I } { \\mathsf { Q } }$ vs Temperature Figure 11. Active $\\mathsf { I } { \\mathsf { Q } }$ vs $\\mathsf { I } ^ { 2 } \\mathsf { C }$ Clock Freque","images":[{"path":"images/008cd8fe28fa4ef1617caeb178bd5a98b50421684ec0c75506e627443955ecf9.jpg","name":"008cd8fe28fa4ef1617caeb178bd5a98b50421684ec0c75506e627443955ecf9.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F008cd8fe28fa4ef1617caeb178bd5a98b50421684ec0c75506e627443955ecf9.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0017"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0018","chunkIndex":17,"heading":"8 Detailed Description","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8 Detailed Description"],"preview":"8 Detailed Description 8.1 Overview The INA219 is a digital current sense amplifier with an I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0018"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0019","chunkIndex":18,"heading":"8.2 Functional Block Diagram","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.2 Functional Block Diagram"],"preview":"8.2 Functional Block Diagram 8.3 Feature Description 8.3.1 Basic ADC Functions The two analog inputs to the INA219, IN+ and IN–, connect to a shunt resistor in the bus of interest. The INA219 is typically powered by a separate supply from 3","images":[{"path":"images/018c6bb411cc5ec00093fa37665b3ceb18e6ef6e199d13d79ee2481a92a6674f.jpg","name":"018c6bb411cc5ec00093fa37665b3ceb18e6ef6e199d13d79ee2481a92a6674f.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F018c6bb411cc5ec00093fa37665b3ceb18e6ef6e199d13d79ee2481a92a6674f.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0019"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0020","chunkIndex":19,"heading":"8.3.1 Basic ADC Functions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.3.1 Basic ADC Functions"],"preview":"When the INA219 is in the normal operating mode (that is, MODE bits of the Configuration register are set to 111), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration regist","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0020"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0021","chunkIndex":20,"heading":"8.3.1 Basic ADC Functions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.3.1 Basic ADC Functions"],"preview":"Writing any of the triggered convert modes into the Configuration register (even if the desired mode is already programmed into the register) triggers a single shot conversion. Table 6 lists the triggered convert mode settings. Feature Desc","images":[{"path":"images/e496c7cb8c198800bdd638899483244dc100a9b088df69caea32a288f688ccfc.jpg","name":"e496c7cb8c198800bdd638899483244dc100a9b088df69caea32a288f688ccfc.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Fe496c7cb8c198800bdd638899483244dc100a9b088df69caea32a288f688ccfc.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0021"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0022","chunkIndex":21,"heading":"8.3.1.1 Power Measurement","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.3.1.1 Power Measurement"],"preview":"8.3.1.1 Power Measurement Current and bus voltage are converted at different points in time, depending on the resolution and averaging mode settings. For instance, when configured for 12 bit and 128 sample averaging, up to 68 ms in time bet","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0022"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0023","chunkIndex":22,"heading":"8.3.1.3 Compatibility With TI Hot Swap Controllers","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.3.1.3 Compatibility With TI Hot Swap Controllers"],"preview":"8.3.1.3 Compatibility With TI Hot Swap Controllers The INA219 is designed for compatibility with hot swap controllers such the TI TPS2490. The TPS2490 uses a high side shunt with a limit at 50 mV; the INA219 full scale range of 40 mV enable","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0023"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0024","chunkIndex":23,"heading":"8.4 Device Functional Modes","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.4 Device Functional Modes"],"preview":"8.4 Device Functional Modes 8.4.1 Filtering and Input Considerations Measuring current is often noisy, and such noise can be difficult to define. The INA219 offers several options for filtering by choosing resolution and averaging in the Co","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0024"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0025","chunkIndex":24,"heading":"8.4.1 Filtering and Input Considerations","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.4.1 Filtering and Input Considerations"],"preview":"Figure 14. INA219 With Input Filtering Overload conditions are another consideration for the INA219 inputs. The INA219 inputs are specified to tolerate 26 V across the inputs. A large differential scenario might be a short to ground on the","images":[{"path":"images/fee8142d14c9016ed4ceb669677717e2dd0260a03b2ccf0949042c257931273e.jpg","name":"fee8142d14c9016ed4ceb669677717e2dd0260a03b2ccf0949042c257931273e.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Ffee8142d14c9016ed4ceb669677717e2dd0260a03b2ccf0949042c257931273e.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0025"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0026","chunkIndex":25,"heading":"8.4.1 Filtering and Input Considerations","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.4.1 Filtering and Input Considerations"],"preview":"In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most l","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0026"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0027","chunkIndex":26,"heading":"8.5 Programming","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5 Programming"],"preview":"8.5 Programming An important aspect of the INA219 device is that it measure current or power if it is programmed based on the system. The device measures both the differential voltage applied between the IN+ and IN input pins and the voltag","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0027"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0028","chunkIndex":27,"heading":"8.5.1 Programming the Calibration Register","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.1 Programming the Calibration Register"],"preview":"8.5.1 Programming the Calibration Register The Calibration Register is calculated based on Equation 1. This equation includes the term Current\\ LSB, which is the programmed value for the LSB for the Current Register (04h). The user uses thi","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0028"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0029","chunkIndex":28,"heading":"8.5.1 Programming the Calibration Register","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.1 Programming the Calibration Register"],"preview":"• 0.04096 is an internal fixed value used to ensure scaling is maintained properly (1) $$ \\text { Current\\ LSB } = \\frac {\\text { Maximum Expected Current }}{2 ^ {1 5}}\\tag{2} $$ $$ \\text { Power\\ LSB } = 2 0 \\text { Current\\ LSB }\\tag{3} $","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0029"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0030","chunkIndex":29,"heading":"8.5.1 Programming the Calibration Register","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.1 Programming the Calibration Register"],"preview":"The value expected in the Power register (03h) can be calculated by multiplying the Current register value by the Bus Voltage register value and then dividing by 5000 as shown in Equation 5. Power Register content is multiplied by Power LSB","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0030"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0031","chunkIndex":30,"heading":"8.5.2 Programming the Power Measurement Engine","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.2 Programming the Power Measurement Engine"],"preview":"8.5.2 Programming the Power Measurement Engine 8.5.2.1 Calibration Register and Scaling The Calibration Register enables the user to scale the Current Register (04h) and Power Register (03h) to the most useful value for a given application.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0031"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0032","chunkIndex":31,"heading":"8.5.2.1 Calibration Register and Scaling","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.2.1 Calibration Register and Scaling"],"preview":"\\text { Corrected\\ Full\\ Scale\\ Cal } = \\text { trunc } \\left(\\frac {\\text { Cal } \\times \\text { MeasShuntCurrent }}{\\text { INA219\\ Current }}\\right)\\tag{6} $$ 8.5.3 Simple Current Shunt Monitor Usage (No Programming Necessary) The INA219","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0032"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0033","chunkIndex":32,"heading":"8.5.4 Default Settings","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.4 Default Settings"],"preview":"8.5.4 Default Settings The default power up states of the registers are shown in the Register Details section of this data sheet. These registers are volatile, and if programmed to other than default values, must be re programmed at every d","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0033"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0034","chunkIndex":33,"heading":"8.5.5 Bus Overview","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.5 Bus Overview"],"preview":"To address a specific device, the master initiates a START condition by pulling the data signal line (SDA) from a HIGH to a LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte on the rising edge of SCL,","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0034"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0035","chunkIndex":34,"heading":"Programming (continued)","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Programming (continued)"],"preview":"Programming (continued) 8.5.5.1 Serial Bus Address To communicate with the INA219, the master must first address slave devices through a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicati","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0035"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0036","chunkIndex":35,"heading":"8.5.5.1 Serial Bus Address","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.5.1 Serial Bus Address"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0036"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0037","chunkIndex":36,"heading":"8.5.5.2 Serial Interface","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.5.2 Serial Interface"],"preview":"8.5.5.2 Serial Interface The INA219 operates only as a slave device on the I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0037"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0038","chunkIndex":37,"heading":"8.5.6 Writing to and Reading from the INA219","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.6 Writing to and Reading from the INA219"],"preview":"8.5.6 Writing to and Reading from the INA219 Accessing a particular register on the INA219 is accomplished by writing the appropriate value to the register pointer. Refer to Table 2 for a complete list of registers and corresponding address","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0038"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0039","chunkIndex":38,"heading":"8.5.6 Writing to and Reading from the INA219","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.6 Writing to and Reading from the INA219"],"preview":"When reading from the INA219, the last value stored in the register pointer by a write operation determines which register is read during a read operation. To change the register pointer for a read operation, a new value must be written to","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0039"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0040","chunkIndex":39,"heading":"www.ti.com","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","www.ti.com"],"preview":"www.ti.com pointer. This byte is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master acknowledges receipt of the data byte. The master may terminate data transfer by generating a Not A","images":[{"path":"images/34b21509e7a0a9a9521486158f8db22e4203011a3de340996723b4855e4498a8.jpg","name":"34b21509e7a0a9a9521486158f8db22e4203011a3de340996723b4855e4498a8.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F34b21509e7a0a9a9521486158f8db22e4203011a3de340996723b4855e4498a8.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0040"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0041","chunkIndex":40,"heading":"www.ti.com","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","www.ti.com"],"preview":"(3) ACK by Master can also be sent. Figure 16. Timing Diagram for Read Word Format NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1. Figure 17. Timing Diagram for SMBus Aler","images":[{"path":"images/857d8a963658f78c8e2972cf42e82dcf2b5a7ba039c65b5fd10208c6b4572fa1.jpg","name":"857d8a963658f78c8e2972cf42e82dcf2b5a7ba039c65b5fd10208c6b4572fa1.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2F857d8a963658f78c8e2972cf42e82dcf2b5a7ba039c65b5fd10208c6b4572fa1.jpg"},{"path":"images/bbff5e0bddd581472d9d31dee0458abafb76a93fa149e6384e85744dd3cda786.jpg","name":"bbff5e0bddd581472d9d31dee0458abafb76a93fa149e6384e85744dd3cda786.jpg","mimeType":"image/jpeg","semanticKind":null,"semanticCaption":null,"viewUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/asset?path=images%2Fbbff5e0bddd581472d9d31dee0458abafb76a93fa149e6384e85744dd3cda786.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0041"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0042","chunkIndex":41,"heading":"8.5.6.1 High-Speed I<sup>2</sup>C Mode","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.6.1 High-Speed I<sup>2</sup>C Mode"],"preview":"8.5.6.1 High Speed I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0042"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0043","chunkIndex":42,"heading":"8.5.6.2 Power-Up Conditions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.5.6.2 Power-Up Conditions"],"preview":"8.5.6.2 Power Up Conditions Power up conditions apply to a software reset through the RST bit (bit 15) in the Configuration register, or the I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0043"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0044","chunkIndex":43,"heading":"8.6.1 Register Information","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.6.1 Register Information"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0044"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0045","chunkIndex":44,"heading":"8.6.2 Register Details","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.6.2 Register Details"],"preview":"8.6.2 Register Details All INA219 16 bit registers are actually two 8 bit bytes through the I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0045"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0046","chunkIndex":45,"heading":"Table 3. Bit Descriptions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Table 3. Bit Descriptions"],"preview":"Table 3. Bit Descriptions RST: Reset Bit Bit 15 Setting this bit to '1' generates a system reset that is the same as power on reset. Resets all registers to default values; this bit self clears. BRNG: Bus Voltage Range Bit 13 0 = 16V FSR 1","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0046"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0047","chunkIndex":46,"heading":"Table 3. Bit Descriptions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Table 3. Bit Descriptions"],"preview":"These bits adjust the Shunt ADC resolution (9 , 10 , 11 , or 12 bit) or set the number of samples used when averaging results for the Shunt Voltage Register (01h). BADC (Bus) and SADC (Shunt) ADC resolution/averaging and conversion time set","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0047"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0048","chunkIndex":47,"heading":"Table 3. Bit Descriptions","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","Table 3. Bit Descriptions"],"preview":"(1) Shaded values are default. (2) X = Don't care MODE: Operating Mode Bits 0–2 Selects continuous, triggered, or power down mode of operation. These bits default to continuous shunt and bus measurement mode. The mode settings are shown in","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0048"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0049","chunkIndex":48,"heading":"8.6.3 Data Output Registers","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","8.6.3 Data Output Registers"],"preview":"8.6.3 Data Output Registers 8.6.3.1 Shunt Voltage Register (address = 01h) The Shunt Voltage register stores the current shunt voltage reading, $\\mathsf { V } { \\mathsf { S H U N T } }$ . Shunt Voltage register bits are shifted according to","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0049"},{"chunkId":"ds_5ab2bfb8b25d33b977bb-chunk-0050","chunkIndex":49,"heading":"www.ti.com","headingPath":["INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I<sup>2</sup>C Interface","www.ti.com"],"preview":"www.ti.com 4. Complement the binary result : 000 0010 1111 1111 5. Add 1 to the Complement to create the Two’s Complement formatted result → 000 0011 0000 0000 6. Extend the sign and create the 16 bit word: 1000 0011 0000 0000 = 8300h (Reme","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_5ab2bfb8b25d33b977bb/chunks/ds_5ab2bfb8b25d33b977bb-chunk-0050"}]}