{"datasheetId":"ds_88666e8763a513a1608e","chunkCount":137,"revision":"2026-11-09T20:05:49.021Z","source":"index","nextCursor":"49","chunks":[{"chunkId":"ds_88666e8763a513a1608e-chunk-0001","chunkIndex":0,"heading":"DPS310","headingPath":["DPS310"],"preview":"DPS310 Digital XENSIV","images":[{"path":"images/3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg","name":"3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image 3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0001"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0002","chunkIndex":1,"heading":"Product Description","headingPath":["DPS310","Product Description"],"preview":"The internal signal processor converts the output from the pressure and temperature sensor elements to 24 bit results. Each unit is individually calibrated, the calibration coeficients calculated during this process are stored in the calibr","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0002"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0003","chunkIndex":2,"heading":"Features","headingPath":["DPS310","Features"],"preview":"Features • Operation range: Pressure: 300 –1200 hPa. Temperature: 40 – 85 °C. • Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode). • Relative accuracy: ± 0.06 hPa (or ±0.5 m) • Absolute accuracy: ± 1 hPa (or ±8 m) •","images":[{"path":"images/8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg","name":"8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image 8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0003"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0004","chunkIndex":3,"heading":"Typical Applications","headingPath":["DPS310","Typical Applications"],"preview":"Typical Applications • Indoor Navigation (floor detection e.g. in shopping malls and parking garages) • Health and Sports (accurate elevation gain and vertical speed) • Outdoor Navigation (GPS start up time and accuracy improvement, dead re","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0004"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0005","chunkIndex":4,"heading":"Table of contents","headingPath":["DPS310","Table of contents"],"preview":"Table of contents Product Description .... 1 Features .... 1 Typical Applications .... 1 Table of contents .... 2 1 Definitions, acronyms and abbreviations .... 4 1.1 Definitions .... 4 2 Pin Configuration and Block Diagram .... 5 2.1 Pin C","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0005"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0006","chunkIndex":5,"heading":"Table of contents","headingPath":["DPS310","Table of contents"],"preview":"5.2 Application Circuit Example .... 18 5.3 IIR filtering .... 19 6 Digital interfaces .... 19 6.1 I2C Interface .... 20 6.2 SPI Interface .... 20 Table of contents 6.3 Interface parameters specification....22 6.3.1 General interface parame","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0006"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0007","chunkIndex":6,"heading":"1 Definitions, acronyms and abbreviations","headingPath":["DPS310","1 Definitions, acronyms and abbreviations"],"preview":"1 Definitions, acronyms and abbreviations 1.1 Definitions An explanation of terms and definitions used in this datasheet. Table 1","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0007"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0008","chunkIndex":7,"heading":"1 Definitions, acronyms and abbreviations","headingPath":["DPS310","1 Definitions, acronyms and abbreviations"],"preview":"Pin Configuration and Block Diagram 2 Pin Configuration and Block Diagram 2.1 Pin Configuration and Description Figure 1 Pin configuration (top view, figure not to scale) Table 2 Pin description","images":[{"path":"images/5ee92ff134bbc4a5e9bfca794b3fc739cffcf4f3cfcf12ebaddba54bbddd3a41.jpg","name":"5ee92ff134bbc4a5e9bfca794b3fc739cffcf4f3cfcf12ebaddba54bbddd3a41.jpg","mimeType":"image/jpeg","semanticKind":"pinout","semanticCaption":"8-pin package pinout","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F5ee92ff134bbc4a5e9bfca794b3fc739cffcf4f3cfcf12ebaddba54bbddd3a41.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0008"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0009","chunkIndex":8,"heading":"Pin Configuration and Description","headingPath":["DPS310","Pin Configuration and Description"],"preview":"Specifications 2.2 Block Diagram Figure 2 3 Specifications 3.1 Operating Range The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections re","images":[{"path":"images/b8dc4b17b06c5dd98c664c5318c0fc9c9db3840692ec92476fa3622d0357ce3a.jpg","name":"b8dc4b17b06c5dd98c664c5318c0fc9c9db3840692ec92476fa3622d0357ce3a.jpg","mimeType":"image/jpeg","semanticKind":"block_diagram","semanticCaption":"Pressure and temperature sensor signal-processing block diagram","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fb8dc4b17b06c5dd98c664c5318c0fc9c9db3840692ec92476fa3622d0357ce3a.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0009"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0010","chunkIndex":9,"heading":"2.2","headingPath":["DPS310","2.2"],"preview":"Specifications 3.2 Absolute Maximum Ratings Maximum ratings are absolute ratings. Exceeding any one of these values may cause irreversible damage to the integrated circuit. Attention: Stresses above the values listed as \"Absolute Maximum Ra","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0010"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0011","chunkIndex":10,"heading":"3.2 Absolute Maximum Ratings","headingPath":["DPS310","3.2 Absolute Maximum Ratings"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0011"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0012","chunkIndex":11,"heading":"3.3 Current Consumption","headingPath":["DPS310","3.3 Current Consumption"],"preview":"3.3 Current Consumption Test conditions (unless otherwise specified in the table): $\\mathsf { V } { \\mathsf { D D } } \\mathsf { = } 1 . 8 \\mathsf { V }$ and $\\mathsf { V } { \\mathsf { D D I O } } = 1 . 8 \\mathsf { V } .$ Typ. values $( \\mat","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0012"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0013","chunkIndex":12,"heading":"3.3 Current Consumption","headingPath":["DPS310","3.3 Current Consumption"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0013"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0014","chunkIndex":13,"heading":"Specifications","headingPath":["DPS310","Specifications"],"preview":"Specifications 3.4 Temperature Transfer Function Test conditions (unless otherwise specified in the table): $\\mathsf { V } { \\mathsf { D D } } \\mathsf { = } 1 . 8 \\mathsf { V }$ and $\\mathsf { V } { \\mathsf { D D I O } } = 1 . 8 \\mathsf { V","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0014"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0015","chunkIndex":14,"heading":"Specifications","headingPath":["DPS310","Specifications"],"preview":"Specifications 3.5 Pressure Transfer Function Test conditions (unless otherwise specified in the table): $\\mathsf { V } { \\mathsf { D D } } \\mathsf { = } 1 . 8 \\mathsf { V }$ and $\\mathsf { V } { \\mathsf { D D I O } } = 1 . 8 \\mathsf { V }","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0015"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0016","chunkIndex":15,"heading":"3.5 Pressure Transfer Function","headingPath":["DPS310","3.5 Pressure Transfer Function"],"preview":"Note: Pressure precision is measured as the average standard deviation. Please refer to the Pressure Configuration (PRS\\ CFG) register description for all precision mode options.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0016"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0017","chunkIndex":16,"heading":"3.5 Pressure Transfer Function","headingPath":["DPS310","3.5 Pressure Transfer Function"],"preview":"Note: The pressure measurement time (and thus the maximum rate) depends on the pressure measurement precision. Please refer to the Pressure Configuration (PRS\\ CFG) register description for an overview of the possible combinations of measur","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0017"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0018","chunkIndex":17,"heading":"3.6 Timing Characteristics","headingPath":["DPS310","3.6 Timing Characteristics"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0018"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0019","chunkIndex":18,"heading":"4.1 Operating Modes","headingPath":["DPS310","4.1 Operating Modes"],"preview":"Note: Operation mode and measurement type are set in the Sensor Operating Mode and Status (MEAS\\ CFG) register. 4.2 Mode transition diagram The mode transition diagram is shown below. Functional Description Figure 3 Mode transition diagram","images":[{"path":"images/a9ce396906e84b6fea7f44a3bdc27b28111f6925d3918753b3bf5c175714f556.jpg","name":"a9ce396906e84b6fea7f44a3bdc27b28111f6925d3918753b3bf5c175714f556.jpg","mimeType":"image/jpeg","semanticKind":"flow_diagram","semanticCaption":"MM control state flow diagram","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fa9ce396906e84b6fea7f44a3bdc27b28111f6925d3918753b3bf5c175714f556.jpg"},{"path":"images/2168463eb81b3d1fc896aca6bd68f55c900d280085b91ac8f1995ed9271790d5.jpg","name":"2168463eb81b3d1fc896aca6bd68f55c900d280085b91ac8f1995ed9271790d5.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"Initialization and coefficient readout timing sequence","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F2168463eb81b3d1fc896aca6bd68f55c900d280085b91ac8f1995ed9271790d5.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0019"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0020","chunkIndex":19,"heading":"4.4 Measurement Precision and Rate","headingPath":["DPS310","4.4 Measurement Precision and Rate"],"preview":"4.4 Measurement Precision and Rate Diferent applications require diferent measurement precision and measurement rates. Some applications, such as weather stations, require lower precision and measurement rates than for instance indoor navig","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0020"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0021","chunkIndex":20,"heading":"Functional Description","headingPath":["DPS310","Functional Description"],"preview":"Functional Description In order to achieve a higher precision, the sensor DPS310 will read multiple times ( oversampling ), and combine the readings into one result. This increases the current consumption and also the measurement time, redu","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0021"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0022","chunkIndex":21,"heading":"Functional Description","headingPath":["DPS310","Functional Description"],"preview":"Enabling temperature measurements allows for compensation of temperature drift in the pressure measurement. The rates of these measurements can be set independently, but temperature compensation is more accurate when temperature and pressur","images":[{"path":"images/133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg","name":"133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image 133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0022"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0023","chunkIndex":22,"heading":"4.5 Sensor Interface","headingPath":["DPS310","4.5 Sensor Interface"],"preview":"4.5 Sensor Interface The DPS310 can be accessed as a slave device through mode '11' SPI 3 wire, SPI 4 wire, or I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0023"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0024","chunkIndex":23,"heading":"4.6 Interrupt","headingPath":["DPS310","4.6 Interrupt"],"preview":"4.6 Interrupt The sensor DPS310 can generate an interrupt when a new measurement result is available and/or when the FIFO is full. The sensor uses the SDO pin for the interrupt signal, and interrupt is therefore not supported if the interfa","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0024"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0025","chunkIndex":24,"heading":"4.7","headingPath":["DPS310","4.7"],"preview":"4.7 Result Register Operation After starting the measurements, the latest pressure and temperature raw data will be available in their respective result registers. Temperature measurement can be skipped. The temperature measurements can be","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0025"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0026","chunkIndex":25,"heading":"4.8 FIFO Operation","headingPath":["DPS310","4.8 FIFO Operation"],"preview":"4.8 FIFO Operation The DPS310 FIFO can store the last 32 measurements of pressure or temperature. This reduces the overal system power consumption as the host processor does not need to continuously poll data from the sensor but can go into","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0026"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0027","chunkIndex":26,"heading":"4.8 FIFO Operation","headingPath":["DPS310","4.8 FIFO Operation"],"preview":"The FIFO can be enabled in the Interrupt and FIFO configuration register. The data from the FIFO is read out from the Pressure Data (PRS\\ Bn) registers regardless of whether the next result in the FIFO is a temperature or a pressure measure","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0027"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0028","chunkIndex":27,"heading":"4.9","headingPath":["DPS310","4.9"],"preview":"4.9 Calibration and Measurement Compensation The sensor DPS310 is a calibrated sensor and contains calibration coeficients. These are used in the application (for instance by the host processor) to compensate the measurement results for sen","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0028"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0029","chunkIndex":28,"heading":"Steps","headingPath":["DPS310","Steps"],"preview":"Steps 1. Read the pressure calibration coeficients (c00, c10, c20, c30, c01, c11, and c21) from the Calibration Coeficient register. Note: The coeficients read from the coeficient register are 2's complement numbers. 2. Choose scaling facto","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0029"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0030","chunkIndex":29,"heading":"Steps","headingPath":["DPS310","Steps"],"preview":"$P {\\text{comp}}(\\text{Pa}) = \\text{c00} + P {\\text{raw\\ sc}} (\\text{c10} + P {\\text{raw\\ sc}} (\\text{c20} + P {\\text{raw\\ sc}} \\text{c30})) + T {\\text{raw\\ sc}} \\text{c01} + T {\\text{raw\\ sc}} P {\\text{raw\\ sc}} (\\text{c11} + P {\\text{raw\\","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0030"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0031","chunkIndex":30,"heading":"Functional Description","headingPath":["DPS310","Functional Description"],"preview":"Functional Description 4. Calculate scaled measurement results.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0031"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0032","chunkIndex":31,"heading":"4.9.3 Compensation Scale Factors","headingPath":["DPS310","4.9.3 Compensation Scale Factors"],"preview":"4.9.4 Pressure and Temperature calculation flow The flow chart below describes the Pressure and Temperature calculate Figure 6 Pressure and temperature calculation flow Functional Description See also How to Calculate Compensated Pressure V","images":[{"path":"images/02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg","name":"02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image 02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0032"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0033","chunkIndex":32,"heading":"5.1 Measurement Settings and Use Case Examples","headingPath":["DPS310","5.1 Measurement Settings and Use Case Examples"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0033"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0034","chunkIndex":33,"heading":"Applications","headingPath":["DPS310","Applications"],"preview":"Applications 5.2 Application Circuit Example The examples application circuit uses the I","images":[{"path":"images/8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg","name":"8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image 8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg"},{"path":"images/e46c531a5b789a3b889b65597a3d82cdac609934bd3ac153bf6d488364c60279.jpg","name":"e46c531a5b789a3b889b65597a3d82cdac609934bd3ac153bf6d488364c60279.jpg","mimeType":"image/jpeg","semanticKind":"schematic","semanticCaption":"SPI connection schematic between a processor and pressure sensor with supply decoupling.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fe46c531a5b789a3b889b65597a3d82cdac609934bd3ac153bf6d488364c60279.jpg"},{"path":"images/c7a6ecb4cf03a693f55035c10f09a7f8889bdc2facc96fab8a54e20dc638803f.jpg","name":"c7a6ecb4cf03a693f55035c10f09a7f8889bdc2facc96fab8a54e20dc638803f.jpg","mimeType":"image/jpeg","semanticKind":"block_diagram","semanticCaption":"Processor-to-pressure-sensor serial interface and power connections","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fc7a6ecb4cf03a693f55035c10f09a7f8889bdc2facc96fab8a54e20dc638803f.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0034"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0035","chunkIndex":34,"heading":"Digital interfaces","headingPath":["DPS310","Digital interfaces"],"preview":"Digital interfaces","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0035"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0036","chunkIndex":35,"heading":"5.3 IIR filtering","headingPath":["DPS310","5.3 IIR filtering"],"preview":"5.3 IIR filtering The air pressure is slowly changing due to weather conditions or short term changing like air turbulence created by a fan, slamming a door or window. All these disturbances can be suppressed or triggered on the software ap","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0036"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0037","chunkIndex":36,"heading":"6","headingPath":["DPS310","6"],"preview":"6 Digital interfaces The DPS310 measurement data, calibration coeficients, Product ID and configuration registers can be accessed through both the I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0037"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0038","chunkIndex":37,"heading":"Digital interfaces","headingPath":["DPS310","Digital interfaces"],"preview":"Digital interfaces 6.1 I2C Interface The I","images":[{"path":"images/711340fd8f1a6367d620db905ddd5e9f01c2cb16bfd73478a197fc3ccee3bd4b.jpg","name":"711340fd8f1a6367d620db905ddd5e9f01c2cb16bfd73478a197fc3ccee3bd4b.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"I2C byte transfer with start, acknowledgment, and stop conditions","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F711340fd8f1a6367d620db905ddd5e9f01c2cb16bfd73478a197fc3ccee3bd4b.jpg"},{"path":"images/b400a3696f5c224d3d1f024419eb61d6f9b8bbad28a92853d432a3cc7a7b9872.jpg","name":"b400a3696f5c224d3d1f024419eb61d6f9b8bbad28a92853d432a3cc7a7b9872.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"I2C write and read command sequences for DPS310","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fb400a3696f5c224d3d1f024419eb61d6f9b8bbad28a92853d432a3cc7a7b9872.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0038"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0039","chunkIndex":38,"heading":"6.2 SPI Interface","headingPath":["DPS310","6.2 SPI Interface"],"preview":"6.2 SPI Interface The SPI interface is compatible with SPI mode '11' ( CPOL = CPHA = '1'. The SPI interface has two modes: 4 wire and 3 wire. The protocol is the same for both. The 3 wire mode is selected by setting '1' to the register Inte","images":[{"path":"images/bee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg","name":"bee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"Extracted datasheet image bee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg.","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fbee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0039"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0040","chunkIndex":39,"heading":"Digital interfaces","headingPath":["DPS310","Digital interfaces"],"preview":"Digital interfaces A SPI write is carried out by setting CSB low and sending a control byte followed by register data. The control byte consist of the SPI register address ( full register address without bit 7) and the write command ( bit7","images":[{"path":"images/6b9f00f79b7984be488c75fbfbff414f0fdbf8ac23c6120a43af55334a8fd538.jpg","name":"6b9f00f79b7984be488c75fbfbff414f0fdbf8ac23c6120a43af55334a8fd538.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"SPI read/write transfer timing diagrams","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F6b9f00f79b7984be488c75fbfbff414f0fdbf8ac23c6120a43af55334a8fd538.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0040"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0041","chunkIndex":40,"heading":"6.3 Interface parameters specification","headingPath":["DPS310","6.3 Interface parameters specification"],"preview":"6.3 Interface parameters specification 6.3.1 General interface parameters The general interface parameters are given in the table below: Table 12 Interface parameters","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0041"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0042","chunkIndex":41,"heading":"6.3.1 General interface parameters","headingPath":["DPS310","6.3.1 General interface parameters"],"preview":"6.3.1.1 I2C timings The I","images":[{"path":"images/d62ea0d2e3624d9ebde00b56f0f314db929eec5942df291ee383fe9ead3f8ff5.jpg","name":"d62ea0d2e3624d9ebde00b56f0f314db929eec5942df291ee383fe9ead3f8ff5.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"Serial bus START, acknowledgment, byte transfer, and STOP timing","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fd62ea0d2e3624d9ebde00b56f0f314db929eec5942df291ee383fe9ead3f8ff5.jpg"},{"path":"images/87d53b08f681e9f6cc79c8bc0a87d47cc337d98e52fe61d51677bb553e8a410f.jpg","name":"87d53b08f681e9f6cc79c8bc0a87d47cc337d98e52fe61d51677bb553e8a410f.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"Clock and data timing diagram","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F87d53b08f681e9f6cc79c8bc0a87d47cc337d98e52fe61d51677bb553e8a410f.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0042"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0043","chunkIndex":42,"heading":"I<sup>2</sup>C timing diagram","headingPath":["DPS310","I<sup>2</sup>C timing diagram"],"preview":"I","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0043"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0044","chunkIndex":43,"heading":"Digital interfaces","headingPath":["DPS310","Digital interfaces"],"preview":"Digital interfaces 6.3.1.2 SPI timings The SPI timing diagram is shown in the figure below and the corresponding values are given in the table below. All timings apply both to 4 wire and 3 wire SPI. Figure 16 SPI timing diagram Table 14 SPI","images":[{"path":"images/d178b951444331bea6379f9f4bac75f5b459425e97d5e0b501a8f1f88e994a51.jpg","name":"d178b951444331bea6379f9f4bac75f5b459425e97d5e0b501a8f1f88e994a51.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"SPI timing diagram for CSB, SCK, SDI, and SDO","viewUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fd178b951444331bea6379f9f4bac75f5b459425e97d5e0b501a8f1f88e994a51.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0044"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0045","chunkIndex":44,"heading":"6.3.1.2 SPI timings","headingPath":["DPS310","6.3.1.2 SPI timings"],"preview":"Register Map 7 Register Map","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0045"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0046","chunkIndex":45,"heading":"Register Map","headingPath":["DPS310","Register Map"],"preview":"8 Register description 8.1 Pressure Data (PRS\\ Bn) The Pressure Data registers contains the 24 bit (3 bytes) 2's complement pressure measurement value. If the FIFO is enabled, the register will contain the FIFO pressure and/or temperature r","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0046"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0047","chunkIndex":46,"heading":"8.1.2 PRS\\_B1","headingPath":["DPS310","8.1.2 PRS\\_B1"],"preview":"8.1.2 PRS\\ B1 The middle byte of the three bytes measured pressure value.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0047"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0048","chunkIndex":47,"heading":"Register description","headingPath":["DPS310","Register description"],"preview":"Register description 8.1.3 PRS\\ B0 The lowest byte of the three bytes measured pressure value.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0048"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0049","chunkIndex":48,"heading":"8.2 Temperature Data (TMP\\_Tn)","headingPath":["DPS310","8.2 Temperature Data (TMP\\_Tn)"],"preview":"8.2 Temperature Data (TMP\\ Tn) The Temperature Data registers contain the 24 bit (3 bytes) 2's complement temperature measurement value ( unless the FIFO is enabled, please see FIFO operation ) and will not be cleared after the read. 8.2.1","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0049"},{"chunkId":"ds_88666e8763a513a1608e-chunk-0050","chunkIndex":49,"heading":"Register description","headingPath":["DPS310","Register description"],"preview":"Register description 8.2.2 TMP\\ B1 The middle byte of the three bytes measured temperature value.","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/chunks/ds_88666e8763a513a1608e-chunk-0050"}]}