## DPS310

## Digital XENSIV<sup>TM</sup> Barometric Pressure Sensor for Portable Devices

## Product Description

The DPS310 is a miniaturized Digital Barometric Air Pressure Sensor with a high accuracy and a low current consumption, capable of measuring both pressure and temperature. The pressure sensor element is based on a capacitive sensing principle which guarantees high precision during temperature changes. The small package makes the DPS310 ideal for mobile applications and wearable devices.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg)

The internal signal processor converts the output from the pressure and temperature sensor elements to 24 bit results. Each unit is individually calibrated, the calibration coeficients calculated during this process are stored in the calibration registers. The coeficients are used in the application to convert the measurement results to high accuracy pressure and temperature values. The result FIFO can store up to 32 measurement results, allowing for a reduced host processor polling rate. Sensor measurements and calibration coeficients are available through the serial I<sup>2</sup>C or SPI interface. The measurement status is indicated by status bits or interrupts on the SDO pin.

## Features

• Operation range: Pressure: 300 –1200 hPa. Temperature: -40 – 85 °C.

• Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode).

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg)

• Relative accuracy: ± 0.06 hPa (or ±0.5 m)

• Absolute accuracy: ± 1 hPa (or ±8 m)

• Temperature accuracy: ± 0.5°C.

• Pressure temperature sensitivity: 0.5Pa/K

Measurement time: Typical: 27.6 ms for standard mode (16x). Minimum: 3.6 ms for low precision mode.

Average current consumption: 1.7 µA for Pressure Measurement, 1.5uA for Temperature measurement @1Hz sampling rate, Standby: 0.5 µA.

• Supply voltage: VDDIO: 1.2 – 3.6 V, VDD: 1.7 – 3.6 V.

• Operating modes: Command (manual), Background (automatic), and Standby.

• Calibration: Individually calibrated with coeficients for measurement correction.

• FIFO: Stores up to 32 pressure or temperature measurements.

• Interface: I<sup>2</sup>C and SPI (both with optional interrupt)

• Package dimensions: 8-pin LGA, 2.0 mm x 2.5 mm x 1.0 mm.

• Green Product (RoHS) Compliant

## Typical Applications

• Indoor Navigation (floor detection e.g. in shopping malls and parking garages)

• Health and Sports (accurate elevation gain and vertical speed)

• Outdoor Navigation (GPS start-up time and accuracy improvement, dead-reckoning e.g. in tunnels)

• Weather Station('Micro-weather' and local forecasts)

• HDD drivers, (leak rate detection in hard disk drives)

• Drones (flight stability and height control)

## Table of contents

## Table of contents

Product Description .... 1
Features .... 1
Typical Applications .... 1
Table of contents .... 2
1 Definitions, acronyms and abbreviations .... 4
1.1 Definitions .... 4
2 Pin Configuration and Block Diagram .... 5
2.1 Pin Configuration and Description .... 5
2.2 Block Diagram .... 6
3 Specifications .... 6
3.1 Operating Range .... 6
3.2 Absolute Maximum Ratings .... 7
3.3 Current Consumption .... 7
3.4 Temperature Transfer Function .... 8
3.5 Pressure Transfer Function .... 9
3.6 Timing Characteristics .... 10
4 Functional Description .... 10
4.1 Operating Modes .... 10
4.2 Mode transition diagram .... 10
4.3 Start-up sequence .... 11
4.4 Measurement Precision and Rate .... 11
4.5 Sensor Interface .... 12
4.6 Interrupt .... 12
4.7 Result Register Operation .... 13
4.8 FIFO Operation .... 13
4.9 Calibration and Measurement Compensation .... 13
4.9.1 How to Calculate Compensated Pressure Values .... 14
4.9.2 How to Calculate Compensated Temperature Values .... 14
4.9.3 Compensation Scale Factors .... 15
4.9.4 Pressure and Temperature calculation flow .... 15
5 Applications .... 17
5.1 Measurement Settings and Use Case Examples .... 17
5.2 Application Circuit Example .... 18
5.3 IIR filtering .... 19
6 Digital interfaces .... 19
6.1 I2C Interface .... 20
6.2 SPI Interface .... 20

## Table of contents

6.3 Interface parameters specification....22
6.3.1 General interface parameters....22
6.3.1.1 I2C timings....22
6.3.1.2 SPI timings....24
7 Register Map....25
8 Register description....25
8.1 Pressure Data (PRS\_Bn)....25
8.1.1 PRS\_B2....26
8.1.2 PRS\_B1....26
8.1.3 PRS\_B0....27
8.2 Temperature Data (TMP\_Tn)....27
8.2.1 TMP\_B2....27
8.2.2 TMP\_B1....28
8.2.3 TMP\_B0....28
8.3 Pressure Configuration (PRS\_CFG)....29
8.4 Temperature Configuration(TMP\_CFG)....31
8.5 Sensor Operating Mode and Status (MEAS\_CFG)....32
8.6 Interrupt and FIFO configuration (CFG\_REG)....33
8.7 Interrupt Status (INT\_STS)....34
8.8 FIFO Status (FIFO\_STS)....35
8.9 Soft Reset and FIFO flush (RESET)....36
8.10 Product and Revision ID (ID)....36
8.11 Calibration Coefficients (COEF)....37
8.12 Coefficient Source....38
9 Package Dimensions....38
10 Package Handling....38
11 Reflow soldering and board assembly....38
Revision History....40
Known Issues List....40
Disclaimer....41

Definitions, acronyms and abbreviations

## 1 Definitions, acronyms and abbreviations

1.1 Definitions

An explanation of terms and definitions used in this datasheet.

Table 1

<table><tr><td>Term</td><td>Definition/explanation</td></tr><tr><td>Absolute accuracy</td><td>The absolute measurement accuracy over the entire measurement range.</td></tr><tr><td>Digital bit depth</td><td>The total bit depth used for conversion of the sensor input to the digital output. Measured in bits.</td></tr><tr><td>Digital resolution</td><td>The pressure value represented by the LSB change in output. This value should be much smaller than the sensor noise.</td></tr><tr><td>Full Scale Range (FSR)</td><td>The peak-to-peak measurement range of the sensor.</td></tr><tr><td>LSB</td><td>Least Significant Bit</td></tr><tr><td>Measurement time</td><td>The time required to acquire one sensor output result. This value determines the maximum measurement rate.</td></tr><tr><td>MSB</td><td>Most Significant Bit</td></tr><tr><td>Non-linearity</td><td>The deviation of measured output from the best-fit straight line, relative to 1000 hPa and 25 °C.</td></tr><tr><td>Output compensation</td><td>The process of applying an algorithm to the sensor output to improve the absolute accuracy of the sensor across temperature and to minimize unit to unit output variation. This algorithm makes use of both the temperature sensor readings and the individual calibration coefficients.</td></tr><tr><td>Precision (noise)</td><td>The smallest measurable change, expressed as rms, after sensor oversampling.</td></tr><tr><td>Pressure temperature coefficient</td><td>The pressure measurement deviation, after compensation, from expected measurement value due to temperature change from 25 °C. Measured in Pa/K.</td></tr><tr><td>Sensor calibration</td><td>The process, during the production test, where the sensor&#x27;s measurement results are compared against reference values, and a set of calibration coefficients are calculated from the deviation. The coefficients are stored in the sensor&#x27;s memory and are used in the output compensation.</td></tr><tr><td>Sensor oversampling rate (OSR)</td><td>Specifies the number of sensor measurements used internally to generate one sensor output result.</td></tr></table>

Pin Configuration and Block Diagram

## 2

## Pin Configuration and Block Diagram

## 2.1

## Pin Configuration and Description

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F5ee92ff134bbc4a5e9bfca794b3fc739cffcf4f3cfcf12ebaddba54bbddd3a41.jpg)  
Figure 1 Pin configuration (top view, figure not to scale)

Table 2  
Pin description

<table><tr><td>Pin</td><td>Name</td><td>SPI 3-wire</td><td>SPI 3-wire with interrupt</td><td>SPI 4-wire</td><td> $I^{2}C$ </td><td> $I^{2}C$  with interrupt</td></tr><tr><td>1</td><td>GND</td><td colspan="5">Ground</td></tr><tr><td>2</td><td>CSB</td><td>Chip select - active low</td><td>Chip select - active low</td><td>Chip select - active low</td><td>Not used - open (internal pull-up) or tie to VDDIO</td><td>Not used - open (internal pull-up) or tie to VDDIO</td></tr><tr><td>3</td><td>SDI</td><td>Serial data in/out</td><td>Serial data in/out</td><td>Serial data in</td><td>Serial data in/out</td><td>Serial data in/out</td></tr><tr><td>4</td><td>SCK</td><td colspan="5">Serial Clock</td></tr><tr><td>5</td><td>SDO</td><td>Not used</td><td>Interrupt</td><td>Serial data out</td><td>Least significant bit in the device address.</td><td>Interrupt pin and least significant bit in the device address.</td></tr><tr><td>6</td><td>VDDIO</td><td colspan="5">Digital supply voltage for digital blocks and I/O interface</td></tr><tr><td>7</td><td>GND</td><td colspan="5">Ground</td></tr><tr><td>8</td><td>VDD</td><td colspan="5">Supply voltage for analog blocks</td></tr></table>

## Specifications

## 2.2

Block Diagram  
![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fb8dc4b17b06c5dd98c664c5318c0fc9c9db3840692ec92476fa3622d0357ce3a.jpg)  
Figure 2

3 Specifications

3.1 Operating Range

The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections refer to these operating conditions, unless noted otherwise.

Table 3 Operating Range

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td>Pressure</td><td> $P_a$ </td><td>300</td><td></td><td>1200</td><td>hPa</td><td></td></tr><tr><td>Temperature</td><td> $T_a$ </td><td>-40</td><td></td><td>85</td><td>°C</td><td></td></tr><tr><td>Supply voltage</td><td> $V_{DD}$ </td><td>1.7</td><td></td><td>3.6</td><td>V</td><td></td></tr><tr><td>Supply voltage IO</td><td> $V_{DDIO}$ </td><td>1.2</td><td></td><td>3.6</td><td>V</td><td></td></tr><tr><td>Supply voltage ramp-up time</td><td> $t_{vddup}$ </td><td>0.001</td><td></td><td>5</td><td>ms</td><td>Time for supply voltage to reach 90% of final value.</td></tr><tr><td>Solder  $drift^{1)}$ </td><td></td><td></td><td>0.8</td><td></td><td>hPa</td><td>Minimum solder height 50um.</td></tr><tr><td>Long term stability</td><td></td><td></td><td>±1</td><td></td><td>hPa</td><td>Depending on environmental conditions.</td></tr></table>

## Specifications

## 3.2 Absolute Maximum Ratings

Maximum ratings are absolute ratings. Exceeding any one of these values may cause irreversible damage to the integrated circuit.

Attention: Stresses above the values listed as "Absolute Maximum Ratings" may cause permanent damage to the devices. Exposure to absolute maximum rating conditions for extended periods may afect device reliability.

Table 5 Current Consumption  
Table 4 Absolute Maximum Ratings

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td> $V_{DD}$  and  $V_{DDIO}$ </td><td> $V_{DDxx\_max}$ </td><td></td><td></td><td>4</td><td>V</td><td></td></tr><tr><td>Voltage on any pin</td><td> $V_{max}$ </td><td></td><td></td><td>4</td><td>V</td><td></td></tr><tr><td>Storage temperature</td><td> $T_s$ </td><td>-40</td><td></td><td>125</td><td>°C</td><td></td></tr><tr><td>Pressure</td><td> $P_{max}$ </td><td></td><td></td><td>10,000</td><td>hPa</td><td></td></tr><tr><td>ESD</td><td> $V_{ESD\_HBM}$ </td><td>-2</td><td></td><td>2</td><td>KV</td><td>HBM (JS001)</td></tr></table>

## 3.3 Current Consumption

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } } { = } 1 0 0 0 \mathsf { h P a }$ and $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$ . Max./Min. values $( \mathsf { P _ { A } } \mathsf { = 9 5 0 } \mathsf { - 1 0 5 0 } \mathsf { h P a }$ and ${ \mathsf { T } } _ { \mathsf { A } } { = } 0 \ldots { + } 6 5 ^ { \circ } { \mathsf { C } } )$

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td rowspan="2">Peak Current Consumption</td><td rowspan="2"> $I_{peak}$ </td><td></td><td>345</td><td></td><td>μA</td><td>during Pressure measurement</td></tr><tr><td></td><td>280</td><td></td><td>μA</td><td>during Temperature measurement</td></tr><tr><td>Standby Current Consumption</td><td> $I_{stb}$ </td><td></td><td>0.5</td><td></td><td>μA</td><td></td></tr><tr><td rowspan="3">Current Consumption.(1 pressure and temperature measurements per second.)</td><td rowspan="3"> $I_{1Hz}$ </td><td></td><td>2.1</td><td></td><td rowspan="3">μA</td><td>Low precision</td></tr><tr><td></td><td>11</td><td></td><td>Standard precision</td></tr><tr><td></td><td>38</td><td></td><td>High precision</td></tr></table>

Note: The current consumption depends on both pressure measurement precision and rate. Please refer to the Pressure Configuration (PRS\_CFG) register description for an overview of the current consumption in diferent combinations of measurement precision and rate.

## Specifications

## 3.4

## Temperature Transfer Function

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } { = } 1 0 0 0 h P a a n c }$ $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$ . Max./Min. values $( \mathsf { P _ { A } } \mathsf { = 9 5 0 - 1 0 5 0 } \mathsf { h P a }$ and ${ \mathsf { T } } _ { \mathsf { A } } { = } 0 \ldots { + } 6 5 ^ { \circ } { \mathsf { C } } )$

Table 6  
Temperature Transfer Function

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td>Temperature accuracy</td><td> $A_t$ </td><td></td><td>+/-0.5</td><td></td><td>°C</td><td></td></tr><tr><td>Temperature data resolution</td><td> $A_{t\_res}$ </td><td></td><td>0.01</td><td></td><td>°C</td><td></td></tr><tr><td>Temperature measurement rate</td><td>f</td><td>1</td><td></td><td>128</td><td>Hz</td><td></td></tr></table>

## Specifications

## 3.5 Pressure Transfer Function

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } } { = } 1 0 0 0 \mathsf { h P a } \mathsf { a n d }$ $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$

Pressure Transfer Function

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td>Absolute pressure accuracy</td><td> $A_{p\_abs}$ </td><td></td><td>+/-100</td><td></td><td>Pa</td><td>Pa=300 - 1200hPa;  $T_A$ =0..+65°C; Excluding solder effects</td></tr><tr><td>Relative pressure accuracy</td><td> $A_{p\_rel}$ </td><td></td><td>+/-6</td><td></td><td>Pa</td><td>Any Δ1hPa in the range Pa=800 - 1200hP; Any constant temperature in the range  $T_A$ =20..+60°C</td></tr><tr><td rowspan="3">Pressure precision</td><td rowspan="3"> $A_{p\_prc}$ </td><td></td><td>1.0</td><td></td><td rowspan="3"> $Pa_{RMS}$ </td><td>Low Power</td></tr><tr><td></td><td>0.35</td><td></td><td>Standard</td></tr><tr><td></td><td>0.2</td><td></td><td>High Precision</td></tr></table>

Note: Pressure precision is measured as the average standard deviation. Please refer to the Pressure Configuration (PRS\_CFG) register description for all precision mode options.

<table><tr><td>Power supply rejection</td><td> $A_{p\_psr}$ </td><td></td><td></td><td>0.063</td><td> $Pa_{RMS}$ </td><td>Measured with 217Hz square wave and broad band noise, 100mVpp</td></tr><tr><td>Pressure temperature sensitivity of calibrated measurements</td><td> $A_{p\_tmp}$ </td><td></td><td>0.5</td><td></td><td>Pa/K</td><td>1000hPa, 25...+65°C.</td></tr><tr><td>Pressure data resolution</td><td> $A_{p\_res}$ </td><td></td><td></td><td>0.06</td><td> $Pa_{RMS}$ </td><td></td></tr><tr><td>Pressure measurement rate</td><td>f</td><td>1</td><td></td><td>128</td><td>Hz</td><td></td></tr><tr><td rowspan="3">Pressure measurement time</td><td rowspan="3">t</td><td></td><td>5.2</td><td></td><td rowspan="3">ms</td><td>Low Power</td></tr><tr><td></td><td>27.6</td><td></td><td>Standard</td></tr><tr><td></td><td>105</td><td></td><td>High Precision</td></tr></table>

Note: The pressure measurement time (and thus the maximum rate) depends on the pressure measurement precision. Please refer to the Pressure Configuration (PRS\_CFG) register description for an overview of the possible combinations of measurement precision and rate

Functional Description

## 3.6 Timing Characteristics

Table 8 Timing Characteristics

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr></table>

<table><tr><td>Time to sensor ready</td><td> $T_{Sensor\_rdy}$ </td><td></td><td></td><td>12</td><td>ms</td><td>The SENSOR_RDY bit in the Measurement Configuration register will be set when the sensor is ready.</td></tr><tr><td>Time to coefficients are available.</td><td> $T_{Coef\_rdy}$ </td><td></td><td></td><td>40</td><td>ms</td><td>The COEF_RDY bit in the Measurement Configuration register will be set when the coefficients can be read out.</td></tr></table>

Note: Start-up timing is measured from VDD > 1.2V & VDDIO > 0.6V or Soft Reset.

<table><tr><td> $I^{2}C$  Clock.</td><td> $f_{I2C}$ </td><td></td><td></td><td>3.4</td><td>MHz</td><td></td></tr><tr><td>SPI Clock</td><td> $f_{SPI}$ </td><td></td><td></td><td>10</td><td>MHz</td><td></td></tr></table>

## 4 Functional Description

## 4.1 Operating Modes

The DPS310 supports 3 diferent modes of operation: Standby, Command, and Background mode.

• Standby Mode

\- Default mode after power on or reset. No measurements are performed.

\- All registers and compensation coeficients are accessible.

• Command Mode

\- One temperature or pressure measurement is performed according to the selected precision.

The sensor will return to Standby Mode when the measurement is finished, and the measurement result will be available in the data registers.

• Background Mode

Pressure and/or temperature measurements are performed continuously according to the selected measurement precision and rate. The temperature measurement is performed immediately after the pressure measurement.

The FIFO can be used to store 32 measurement results and minimize the number of times the sensor must be accessed to read out the results.

Note: Operation mode and measurement type are set in the Sensor Operating Mode and Status (MEAS\_CFG) register.

## 4.2 Mode transition diagram

The mode transition diagram is shown below.

## Functional Description

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fa9ce396906e84b6fea7f44a3bdc27b28111f6925d3918753b3bf5c175714f556.jpg)  
Figure 3 Mode transition diagram

## 4.3 Start-up sequence

The start-up sequence is shown below. This diagram shows when the registers are accessible for read and/or write and also when the Pressure/Temperature measurements can start.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F2168463eb81b3d1fc896aca6bd68f55c900d280085b91ac8f1995ed9271790d5.jpg)  
Figure 4 Start-up sequence

## 4.4 Measurement Precision and Rate

Diferent applications require diferent measurement precision and measurement rates. Some applications, such as weather stations, require lower precision and measurement rates than for instance indoor navigation and sports applications.

When the sensor DPS310 is in Background Mode, the measurement precision and rate can be configured to match the requirements of the application. This reduces current consumption of the sensor and the system.

## Functional Description

In order to achieve a higher precision, the sensor DPS310 will read multiple times ( oversampling ), and combine the readings into one result. This increases the current consumption and also the measurement time, reducing the maximum possible measurement rate. It is necessary to balance the accuracy and data rate required for each application with the allowable current consumption.

The measurement precision, rate and time is set in the Pressure Configuration (PRS\_CFG) and Temperature Configuration(TMP\_CFG) registers. The register descriptions contain information about the current consumption and the possible combinations of measurement precision, time, and rate.

Enabling temperature measurements allows for compensation of temperature drift in the pressure measurement. The rates of these measurements can be set independently, but temperature compensation is more accurate when temperature and pressure measurements are taken together. This reduces the maximum pressure measurement rate, since: Rate<sub>temperature</sub>\*Time<sub>temperature</sub> + Rate<sub>pressure</sub>\*Time<sub>pressure</sub>< 1 second. Measurement Settings and Use Case Examples contains a table with examples of combinations of pressure and temperature precision and rates for diferent use cases.

In the figure below is described the Temperature and Pressure measurements sequence in background mode.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg)  
Figure 5 Background mode temperature and pressure measurements sequence

## 4.5 Sensor Interface

The DPS310 can be accessed as a slave device through mode '11' SPI 3-wire, SPI 4-wire, or I<sup>2</sup>C serial interface.

• I<sup>2</sup>C interface

\- The sensor's default interface.

The sensor's address is 0x77 (default) or 0x76 (if the SDO pin is pulled-down to GND).

• SPI interface

The sensor will switch to SPI configuration if it detects an active low on the CSB pin. SPI 4-wire is the default SPI interface.

To enable SPI 3-wire configuration, a bit must be set in the Interrupt and FIFO configuration (CFG\_REG) register after start up.

More details about digital interfaces are available in the Digital interfaces.

## 4.6 Interrupt

The sensor DPS310 can generate an interrupt when a new measurement result is available and/or when the FIFO is full. The sensor uses the SDO pin for the interrupt signal, and interrupt is therefore not supported if the interface is 4-wire SPI.

The interrupt is enabled and configured in the Interrupt and FIFO configuration (CFG\_REG) register. In I<sup>2</sup>C configuration the SDO pin serves as both interrupt and as the least significant bit in the device address. If the SDO pin is pulled low the interrupt polarity must be set to active high and vice-versa.

The interrupt status can be read from the Interrupt Status (INT\_STS) register.

Functional Description

## 4.7

Result Register Operation

After starting the measurements, the latest pressure and temperature raw data will be available in their respective result registers. Temperature measurement can be skipped. The temperature measurements can be disabled if there is a requirement to measure pressure rapidly, but it will make accurate temperature drift compensation impossible.

All measurement data can be read in a single command using auto-increment read. When FIFO is disabled, reading the result register will not afect the register value, it will only be updated when a new measurement is completed. When FIFO is enabled, the pressure result register will update to the next value in the FIFO after each read. When all of the FIFO values have been read, the result register will be set to 0x800000.

## 4.8 FIFO Operation

The DPS310 FIFO can store the last 32 measurements of pressure or temperature. This reduces the overal system power consumption as the host processor does not need to continuously poll data from the sensor but can go into standby mode for longer periods of time.

The FIFO can store any combination of pressure and temperature results, according to the background mode measurement rate settings. The pressure rate can for instance be set 4 times higher than the temperature rate and thus only every fifth result will be a temperature result. The measurement type can be seen in the result data. The sensor will set the least significant bit to:

• '1' if the result is a pressure measurement.

• '0' if it is a temperature measurement.

The sensor uses 24 bits to store the measurement result. Because this is more bits than is needed to cover the full dynamic range of the pressure sensor, using the least significant bit to label the measurement type will not afect the precision of the result.

The FIFO can be enabled in the Interrupt and FIFO configuration register. The data from the FIFO is read out from the Pressure Data (PRS\_Bn) registers regardless of whether the next result in the FIFO is a temperature or a pressure measurement.

When a measurement has been read out, the FIFO will auto increment and place the next result in the data register. A flag will be set in the FIFO Status register when the FIFO is empty and all following reads will return 0x800000.

If the FIFO is full, the FIFO\_FULL bit in the FIFO Status (FIFO\_STS)will be set. If the INT\_FIFO bit in the Interrupt and FIFO configuration register ( CFG\_REG) is set, an interrupt will also be generated when the FIFO is full. The FIFO will stop recording measurements results when it is full.

## 4.9

## Calibration and Measurement Compensation

The sensor DPS310 is a calibrated sensor and contains calibration coeficients. These are used in the application (for instance by the host processor) to compensate the measurement results for sensor non-linearities.

The sections that follow describe how to calculate the compensated results and convert them into Pa and °C values.

## Functional Description

## 4.9.1 How to Calculate Compensated Pressure Values

## Steps

1. Read the pressure calibration coeficients (c00, c10, c20, c30, c01, c11, and c21) from the Calibration Coeficient register.

Note: The coeficients read from the coeficient register are 2's complement numbers.

2. Choose scaling factors kT (for temperature) and kP (for pressure) based on the chosen precision rate. The scaling factors are listed in Table 9.

3. Read the pressure and temperature result from the registers or FIFO.

Note: The measurements read from the result registers (or FIFO) are 24 bit 2´s complement numbers. Depending on the chosen measurement rates, the temperature may not have been measured since the last pressure measurement.

4. Calculate scaled measurement results.

$$
\begin{array}{r c l} \mathrm {T_ {raw\_sc}} & = & \mathrm {T_ {raw} / kT} \\ \mathrm {P_ {raw\_sc}} & = & \mathrm {P_ {raw} / kP} \end{array}
$$

5. Calculate compensated measurement results.

<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;">
$P_{\text{comp}}(\text{Pa}) = \text{c00} + P_{\text{raw\_sc}} * (\text{c10} + P_{\text{raw\_sc}} * (\text{c20} + P_{\text{raw\_sc}} * \text{c30})) + T_{\text{raw\_sc}} * \text{c01} + T_{\text{raw\_sc}} * P_{\text{raw\_sc}} * (\text{c11} + P_{\text{raw\_sc}} * \text{c21})$
</div>

## 4.9.2 How to Calculate Compensated Temperature Values

## Steps

1. Read the temperature calibration coeficients ( c0 and c1 ) from the Calibration Coeficients (COEF) register.

Note: The coeficients read from the coeficient register are 12 bit 2´s complement numbers.

2. Choose scaling factor kT (for temperature) based on the chosen precision rate. The scaling factors are listed in Table 9.

3. Read the temperature result from the temperature register or FIFO.

Note: The temperature measurements read from the temperature result register (or FIFO) are 24 bit 2´s complement numbers

## Functional Description

4. Calculate scaled measurement results.

<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;">
$\mathrm{T_{raw\_sc}} = \mathrm{T_{raw} / kT}$
</div>

5. Calculate compensated measurement results.

<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;">
$\mathrm{T_{comp}}$ (°C) = c0*0.5 + c1*Traw_sc
</div>

## 4.9.3 Compensation Scale Factors

Table 9 Compensation Scale Factors

<table><tr><td>Oversampling Rate</td><td>Scale Factor (kP or kT)</td><td>Result shift ( bit 2and 3 address 0x09)</td></tr><tr><td>1 (single)</td><td>524288</td><td>0</td></tr><tr><td>2 times (Low Power)</td><td>1572864</td><td>0</td></tr><tr><td>4 times</td><td>3670016</td><td>0</td></tr><tr><td>8 times</td><td>7864320</td><td>0</td></tr><tr><td>16 times (Standard)</td><td>253952</td><td>enable pressure or temperature shift</td></tr><tr><td>32 times</td><td>516096</td><td>enable pressure or temperature shift</td></tr><tr><td>64 times (High Precision)</td><td>1040384</td><td>enable pressure or temperature shift</td></tr><tr><td>128 times</td><td>2088960</td><td>enable pressure or temperature shift</td></tr></table>

4.9.4 Pressure and Temperature calculation flow

The flow chart below describes the Pressure and Temperature calculate

Figure 6 Pressure and temperature calculation flow

Functional Description

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg)  
See also How to Calculate Compensated Pressure Values and How to Calculate Compensated Temperature Values

## Applications

## 5

## Applications

## 5.1 Measurement Settings and Use Case Examples

Table 10  
Measurement Settings and Use Case Examples (TBD)

<table><tr><td>Use Case</td><td>Performance</td><td>Pressure Register Configuration Address: 0x06</td><td>Temperature Register Configuration Address: 0x07</td><td>Other</td></tr><tr><td>Weather Station (Low power)</td><td>5 Pa precision.1 pr sec.3 uA</td><td>0x01</td><td>0x80</td><td>Start background measurements (addr 0x08)</td></tr><tr><td>Indoor navigation (Standard precision, background mode)</td><td>10 cm precision.2 pr sec.22 uA</td><td>0x14</td><td>0x90</td><td>Enable P shift (addr 0x09)Start background measurements (addr 0x08)</td></tr><tr><td>Sports (High precision, high rate, background mode)</td><td>5 cm precision4 pr sec.200 uA</td><td>0x26</td><td>0xA0</td><td>Enable P shift (addr 0x09)Start background measurements (addr 0x08)</td></tr></table>

## Applications

## 5.2

## Application Circuit Example

The examples application circuit uses the I<sup>2</sup>C and SPI serial interface. The SDO pin can be used for interrupt or to set least significant bit of the device address. The DPS310 analog core supply voltage is internally regulated, guaranteeing robustness to external VDD supply variations within the specified range. The simplest voltage supply solution is to connect VDD and VDDIO to 1.8V supply and add a suitable decoupling capacitor to reduce VDD ripple below 50mVpp.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg)  
Figure 7 Application Circuit Example using the I<sup>2</sup>C serial interface.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fe46c531a5b789a3b889b65597a3d82cdac609934bd3ac153bf6d488364c60279.jpg)  
Figure 8  
Application Circuit Example using the SPI 4-wires serial interface

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fc7a6ecb4cf03a693f55035c10f09a7f8889bdc2facc96fab8a54e20dc638803f.jpg)  
Figure 9  
Application Circuit Example using the SPI 3-wire serial interface

## Digital interfaces

<table><tr><td rowspan="5">Processor</td><td rowspan="5">SPI Serial Interface</td><td colspan="2">Pressure Sensor</td></tr><tr><td>SCL</td><td>SCK</td></tr><tr><td>IO_0</td><td>SDI</td></tr><tr><td>IO_1</td><td>SDO</td></tr><tr><td>SS</td><td>CSB</td></tr></table>

Figure 10 Application Circuit Example using the SPI 3-wire with interrupt interface

Table 11 Component Values

<table><tr><td rowspan="2">Component</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note / Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td rowspan="2">Pull-up/down Resistor</td><td> $R_1, R_2$ </td><td></td><td></td><td>10</td><td>KΩ</td><td></td></tr><tr><td> $R_3$ </td><td></td><td></td><td>100</td><td>KΩ</td><td> $R_3$  is optional and will set the address to 0x76 instead of 0x77.</td></tr><tr><td>Supply Blocking Capacitor</td><td> $C_1, C_2$ </td><td>100</td><td>100</td><td></td><td>nF</td><td>The blocking capacitors should be placed as close to the package pins as possible.</td></tr></table>

## 5.3 IIR filtering

The air pressure is slowly changing due to weather conditions or short term changing like air turbulence created by a fan, slamming a door or window. All these disturbances can be suppressed or triggered on the software application level by implementing diferent IIR filtering.

Same sensor can be used by diferent software applications applying diferent IIR filtering to the raw data like low pass, high pass or band pass filtering.

## 6

## Digital interfaces

The DPS310 measurement data, calibration coeficients, Product ID and configuration registers can be accessed through both the I<sup>2</sup>C and SPI serial interfaces.

The SPI interface can configured to operate in 3-wire or 4-wire mode. In I2C and SPI 3-wire, an interrupt output can be implemented on the SDO pin. The SPI interface support mode '11' only ( CPOL=CPHA='1' ) in 4-wire and 3-wire configuration. The following commands are supported: single byte write, single byte read and multiple byte read using auto increment from a specified start address. The interface selection is done based on CSB pin status. If CSB is connected to $V _ { \mathsf { D D I O } }$ , the I<sup>2</sup>C interface is active. If CSB is low, the SPI interface is active. After the CSB has been pulled down once the I<sup>2</sup>C interface is disabled until the next power-on-reset.

## Digital interfaces

## 6.1

I2C Interface

The I<sup>2</sup>C slave interface is compatible with Philips I<sup>2</sup>C Specification version 2.1. The I<sup>2</sup>C interface supports standard, fast and high speed mode.

The sensor's address is 0x77 (if SDO pin is left floating or pulled-up to VDDIO) or 0x76 (if the SDO pin is pulled-down to GND). The I<sup>2</sup>C interface uses the pins described in Table 2

The basic timing is shown in the diagram below:

Figure 13 SPI protocol, 4-wire without interrupt  
![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F711340fd8f1a6367d620db905ddd5e9f01c2cb16bfd73478a197fc3ccee3bd4b.jpg)  
Figure 11 I2C timing diagram

In one access, without stop, incremental read (address is auto increment) and auto-incremental write is supported. The read and write access is described below:

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fb400a3696f5c224d3d1f024419eb61d6f9b8bbad28a92853d432a3cc7a7b9872.jpg)  
Figure 12 I2C write and read commands

## 6.2 SPI Interface

The SPI interface is compatible with SPI mode '11' ( CPOL = CPHA = '1'. The SPI interface has two modes: 4-wire and 3-wire.

The protocol is the same for both. The 3-wire mode is selected by setting '1' to the register Interrupt and FIFO configuration (CFG\_REG)

The SPI interface uses the pins like in theTable 2 Refere toApplication Circuit Example for connections instructions. The SPI protocol is shown in the diagram below:

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fbee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg)

## Digital interfaces

A SPI write is carried out by setting CSB low and sending a control byte followed by register data. The control byte consist of the SPI register address ( full register address without bit 7) and the write command ( bit7 = RW = '0'). Setting CSB high ends the transaction. The SPI write protocol is described in the diagram below.

A SPI read is initiated by setting CSB low and sending a single control byte. The control byte consist of the SPI register address ( = full register address without bit 7) and the read command ( bit7 = RW = '1'). After writing the control byte, data is sent out of the SDO pin ( SDI in 3-wire mode); the register address is automatically incremented. Sending CSB high ends the SPI read transaction. The SPI read protocol is shown in the diagram below:

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F6b9f00f79b7984be488c75fbfbff414f0fdbf8ac23c6120a43af55334a8fd538.jpg)  
Figure 14 SPI write, read protocol diagrams

Digital interfaces

## 6.3 Interface parameters specification

## 6.3.1 General interface parameters

The general interface parameters are given in the table below:

Table 12 Interface parameters

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note or Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td>Input voltage for low logic level at input pins</td><td>Vlow_in</td><td></td><td></td><td>0.3*  $V_{DDIO}$ </td><td>V</td><td> $V_{DDIO}=1.2V$  to 3.6V</td></tr><tr><td>Input voltage for high logic level at input pins</td><td>Vhigh_in</td><td>0.7*  $V_{DDIO}$ </td><td></td><td></td><td>V</td><td> $V_{DDIO}=1.2V$  to 3.6V</td></tr><tr><td>Output - low level for I2C</td><td>Vlow_SDI</td><td></td><td></td><td>0.1*  $V_{DDIO}$ </td><td>V</td><td> $V_{DDIO}=1.8V, \text{iol}=2mA$ </td></tr><tr><td>Output voltage for low level at pin SDI for I2C</td><td>Vlow_SDI_1.2</td><td></td><td></td><td>0.2*  $V_{DDIO}$ </td><td>V</td><td> $V_{DDIO}=1.20V, \text{iol}=1.3mA$ </td></tr><tr><td>Output voltage for high level at pins SDO, SDI</td><td>Vhigh_out</td><td>0.8*  $V_{DDIO}$ </td><td></td><td></td><td>V</td><td> $V_{DDIO}=1.8V, \text{iol}=1mA$  (SDO, SDI)</td></tr><tr><td>Output voltage for high level at pins SDO, SDI</td><td>Vhigh_out_1.2</td><td>0.6*  $V_{DDIO}$ </td><td></td><td></td><td>V</td><td> $V_{DDIO}=1.2V, \text{iol}=1mA$  (SDO, SDI)</td></tr><tr><td>Pull-up resistor</td><td>Rpull</td><td>60</td><td>120</td><td>180</td><td>kohm</td><td>Internal pull-up resistance to  $V_{DDIO}$ </td></tr><tr><td> $I^{2}C$  bus load capacitor</td><td>Cb</td><td></td><td></td><td>400</td><td>pF</td><td>On SDI and SCK</td></tr></table>

## 6.3.1.1 I2C timings

The I<sup>2</sup>C timing is shown in the diagram below and corresponding values are given in the table below. The naming refers to I<sup>2</sup>C Specification version 2.1, the abbreviations used "S&F mode" = standard and fast mode, "HS mode" = high speed mode, Cb = bus capacitance on SDA line.

## Digital interfaces

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fd62ea0d2e3624d9ebde00b56f0f314db929eec5942df291ee383fe9ead3f8ff5.jpg)  
Data transfer on the I2C-bus

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F87d53b08f681e9f6cc79c8bc0a87d47cc337d98e52fe61d51677bb553e8a410f.jpg)  
Figure 15

## I<sup>2</sup>C timing diagram

Table 13 I2C timings

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note or Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td rowspan="2">Data setup time on SDI pin</td><td rowspan="2"> $t_{Setup}$ </td><td>20</td><td></td><td></td><td>ns</td><td>S&amp;F mode</td></tr><tr><td>5</td><td></td><td></td><td>ns</td><td>HS mode</td></tr><tr><td>Data hold time on SDI pin</td><td> $t_{Hold}$ </td><td>0</td><td></td><td></td><td>ns</td><td>S&amp;F&amp;HSmode,</td></tr><tr><td rowspan="2">Duty Cycle</td><td rowspan="2">DC</td><td></td><td></td><td>70</td><td>%</td><td>S&amp;F mode,</td></tr><tr><td></td><td></td><td>55</td><td>%</td><td>HS mode,</td></tr></table>

## Digital interfaces

## 6.3.1.2 SPI timings

The SPI timing diagram is shown in the figure below and the corresponding values are given in the table below. All timings apply both to 4-wire and 3-wire SPI.

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2Fd178b951444331bea6379f9f4bac75f5b459425e97d5e0b501a8f1f88e994a51.jpg)  
Figure 16 SPI timing diagram

Table 14 SPI timings

<table><tr><td rowspan="2">Parameter</td><td rowspan="2">Symbol</td><td colspan="3">Values</td><td rowspan="2">Unit</td><td rowspan="2">Note or Test Condition</td></tr><tr><td>Min.</td><td>Typ.</td><td>Max.</td></tr><tr><td rowspan="2">Duty Cycle (Thigh%)</td><td rowspan="2">SPI_DC</td><td>30</td><td></td><td></td><td>%</td><td> $V_{DDIO} = 1.2V$ </td></tr><tr><td>20</td><td></td><td></td><td>%</td><td> $V_{DDIO} = 1.8V/3.6V$ </td></tr><tr><td>SDI setup time</td><td>T_setup_sdi</td><td>2</td><td></td><td></td><td>ns</td><td></td></tr><tr><td>SDI hold time</td><td>T_hold_sdi</td><td>2</td><td></td><td></td><td>ns</td><td></td></tr><tr><td>Clock</td><td>SPI_CLK</td><td></td><td></td><td>10</td><td>MHz</td><td></td></tr><tr><td>CSB setup time</td><td>T_setup_csb</td><td>15</td><td></td><td></td><td>ns</td><td></td></tr><tr><td>CSB hold time</td><td></td><td>15</td><td></td><td></td><td>ns</td><td></td></tr></table>

Register Map

## 7

## Register Map

<table><tr><td>Register Name</td><td>Addr.</td><td>bit7</td><td>bit6</td><td>bit5</td><td>bit4</td><td>bit3</td><td>bit2</td><td>bit1</td><td>bit0</td><td>Reset State</td></tr><tr><td>PSR_B2</td><td>0x00</td><td colspan="8">PSR[23:16] (r)</td><td> $00_h$ </td></tr><tr><td>PSR_B1</td><td>0x01</td><td colspan="8">PSR[15:8](r)</td><td> $00_h$ </td></tr><tr><td>PSR_B0</td><td>0x02</td><td colspan="8">PSR[7:0](r)</td><td> $00_h$ </td></tr><tr><td>TMP_B2</td><td>0x03</td><td colspan="8">TMP[23:16] (r)</td><td> $00_h$ </td></tr><tr><td>TMP_B1</td><td>0x04</td><td colspan="8">TMP[15:8] (r)</td><td> $00_h$ </td></tr><tr><td>TMP_B0</td><td>0x05</td><td colspan="8">TMP[7:0] (r)</td><td> $00_h$ </td></tr><tr><td>PRS_CFG</td><td>0x06</td><td>-</td><td colspan="3">PM_RATE [2:0] (rw)</td><td colspan="4">PM_PRC [3:0] (rw)</td><td> $00_h$ </td></tr><tr><td>TMP_CFG</td><td>0x07</td><td>TMP_EXT(rw)</td><td colspan="3">TMP_RATE [2:0] (rw)</td><td colspan="4">TM_PRC [3:0] (rw)</td><td> $00_h$ </td></tr><tr><td>MEAS_CFG</td><td>0x08</td><td>COEF_RDY (r)</td><td>SENSOR_RDY (r)</td><td>TMP_RDY (r)</td><td>PRS_RDY (r)</td><td>-</td><td colspan="3">MEAS_CTRL [2:0] (rw)</td><td> $C0_h$ </td></tr><tr><td>CFG_REG</td><td>0x09</td><td>INT_HL(rw)</td><td colspan="3">INT_SEL [2:0] (rw)</td><td>TMP_SHIFT_EN (rw)</td><td>PRS_SHIFT_EN (rw)</td><td>FIFO_EN (rw)</td><td>SPI_MODE(rw)</td><td> $00_h$ </td></tr><tr><td>INT_STS</td><td>0x0A</td><td>-</td><td>-</td><td>-</td><td>-</td><td>-</td><td>INT_FIFO_FULL (r)</td><td>INT_TMP(r)</td><td>INT_PRS(r)</td><td> $00_h$ </td></tr><tr><td>FIFO_STS</td><td>0x0B</td><td>-</td><td>-</td><td>-</td><td>-</td><td>-</td><td>-</td><td>FIFO_FULL(r)</td><td>FIFO_EMPTY(r)</td><td> $00_h$ </td></tr><tr><td>RESET</td><td>0x0C</td><td>FIFO_FLUSH(w)</td><td>-</td><td>-</td><td>-</td><td colspan="4">SOFT_RST [3:0] (w)</td><td> $00_h$ </td></tr><tr><td>Product ID</td><td>0x0D</td><td colspan="4">REV_ID [3:0] (r)</td><td colspan="4">PROD_ID [3:0] (r)</td><td> $10_h$ </td></tr><tr><td>COEF</td><td>0x10-0x21</td><td colspan="8">&lt; see register description &gt;</td><td> $XX_h$ </td></tr><tr><td>Reserved</td><td>0x22-0x27</td><td colspan="8">Reserved</td><td> $XX_h$ </td></tr><tr><td>COEF_SRCE</td><td>0x28</td><td>TMP_COEF_SRCE (r)</td><td colspan="7">Reserved</td><td> $XX_h$ </td></tr></table>

## 8 Register description

## 8.1 Pressure Data (PRS\_Bn)

The Pressure Data registers contains the 24 bit (3 bytes) 2's complement pressure measurement value. If the FIFO is enabled, the register will contain the FIFO pressure and/or temperature results. Otherwise, the register contains the pressure measurement results and will not be cleared after read.

## Register description

## 8.1.1 PRS\_B2

The highest byte of the three bytes measured pressure value.

<table><tr><td colspan="3">PRS_B2</td><td colspan="4">Address:</td><td> $00_{H}$ </td></tr><tr><td colspan="3">Pressure (MSB data)</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">PRS[23:16]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>PRS[23:16]</td><td>7:0</td><td>r</td><td>MSB of 24 bit 2&#x27;s complement pressure data.</td></tr></table>

## 8.1.2 PRS\_B1

The middle byte of the three bytes measured pressure value.

<table><tr><td>PRS_B1</td><td>Address:</td><td> $01_{H}$ </td></tr><tr><td>Pressure (LSB data)</td><td>Reset value:</td><td> $00_{H}$ </td></tr></table>

<table><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">PRS[15:8]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>PRS[15:8]</td><td>7:0</td><td>r</td><td>LSB of 24 bit 2&#x27;s complement pressure data.</td></tr></table>

## Register description

## 8.1.3 PRS\_B0

The lowest byte of the three bytes measured pressure value.

<table><tr><td colspan="3">PRS_B0</td><td colspan="4">Address:</td><td> $02_{H}$ </td></tr><tr><td colspan="3">Pressure (XLSB data)</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">PRS[7:0]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>PRS[7:0]</td><td>7:0</td><td>r</td><td>XLSB of 24 bit 2&#x27;s complement pressure data.</td></tr></table>

## 8.2 Temperature Data (TMP\_Tn)

The Temperature Data registers contain the 24 bit (3 bytes) 2's complement temperature measurement value ( unless the FIFO is enabled, please see FIFO operation ) and will not be cleared after the read.

## 8.2.1 TMP\_B2

The highest byte of the three bytes measured temperature value.

<table><tr><td colspan="3">TMP_B2</td><td colspan="4">Address:</td><td> $03_{H}$ </td></tr><tr><td colspan="3">Temperature (MSB data)</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">TMP[23:16]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>TMP[23:16]</td><td>7:0</td><td>r</td><td>MSB of 24 bit 2&#x27;s complement temperature data.</td></tr></table>

## Register description

## 8.2.2 TMP\_B1

The middle byte of the three bytes measured temperature value.

<table><tr><td>TMP_B1</td><td>Address:</td><td> $04_{H}$ </td></tr><tr><td>Temperature (LSB data)</td><td>Reset value:</td><td> $00_{H}$ </td></tr></table>

<table><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">TMP[15:8]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>TMP[15:8]</td><td>7:0</td><td>r</td><td>LSB of 24 bit 2&#x27;s complement temperature data.</td></tr></table>

## 8.2.3 TMP\_B0

The lowest part of the three bytes measured temperature value.

<table><tr><td>TMP_B0</td><td>Address:</td><td> $05_{H}$ </td></tr><tr><td>Temperature (XLSB data)</td><td>Reset value:</td><td> $00_{H}$ </td></tr></table>

<table><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="8">TMP[7:0]</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>TMP[7:0]</td><td>7:0</td><td>r</td><td>XLSB of 24 bit 2&#x27;s complement temperature data.</td></tr></table>

\*) Note: Use in combination with a bit shift. See Interrupt and FIFO configuration (CFG\_REG) register

## Register description

## 8.3 Pressure Configuration (PRS\_CFG)

Configuration of pressure measurement rate (PM\_RATE) and resolution (PM\_PRC).

<table><tr><td colspan="2">PRS_CFG</td><td colspan="3">Address:</td><td>06H</td></tr><tr><td colspan="2">Pressure measurement configuration</td><td colspan="3">Reset value:</td><td>00H</td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td></tr><tr><td>-</td><td colspan="3">PM_RATE[2:0]</td><td colspan="2">PM_PRC[3:0]</td></tr><tr><td>-</td><td colspan="3">rw</td><td colspan="2">rw</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>-</td><td>7</td><td>-</td><td>Reserved.</td></tr><tr><td>PM_RATE[2:0]</td><td>6:4</td><td>rw</td><td>Pressure measurement rate:000 - 1 measurements pr. sec.001 - 2 measurements pr. sec.010 - 4 measurements pr. sec.011 - 8 measurements pr. sec.100 - 16 measurements pr. sec.101 - 32 measurements pr. sec.110 - 64 measurements pr. sec.111 - 128 measurements pr. sec.Applicable for measurements in Background mode only</td></tr><tr><td>PM_PRC[3:0]</td><td>3:0</td><td>rw</td><td>Pressure oversampling rate:0000 - Single. (Low Precision)0001 - 2 times (Low Power).0010 - 4 times.0011 - 8 times.0100 *) - 16 times (Standard).0101 *) - 32 times.0110 *) - 64 times (High Precision).0111 *) - 128 times.1xxx - Reserved</td></tr></table>

## Register description

Table 16 Precision (Pa<sub>RMS</sub>) and pressure measurement time (ms) versus oversampling rate

<table><tr><td>Oversampling (PRC[3:0])</td><td>Single (0000)</td><td>2 times (0001)</td><td>4 times (0010)</td><td>8 times (0011)</td><td>16 times (0100)</td><td>32 times (0101)</td><td>64 times (0110)</td><td>128 times (0111)</td></tr><tr><td>Measurement time (ms)</td><td>3.6</td><td>5.2</td><td>8.4</td><td>14.8</td><td>27.6</td><td>53.2</td><td>104.4</td><td>206.8</td></tr><tr><td>Precision ( $Pa_{RMS}$ )</td><td>2.5</td><td>1</td><td>0.5</td><td>0.4</td><td>0.35</td><td>0.3</td><td>0.2</td><td></td></tr></table>

Table 17  
Estimated current consumption (uA)

<table><tr><td>Oversampling (PRC[3:0])</td><td rowspan="2">Single (0000)</td><td rowspan="2">2 times (0001)</td><td rowspan="2">4 times (0010)</td><td rowspan="2">8 times (0011)</td><td rowspan="2">16 times (0100)</td><td rowspan="2">32 times (0101)</td><td rowspan="2">64 times (0110)</td><td rowspan="2">128 times (0111)</td></tr><tr><td>Measurements pr sec. (PM_RATE([2:0])</td></tr><tr><td>1 (000)</td><td>2.1</td><td>2.7</td><td>3.8</td><td>6.1</td><td>11</td><td>20</td><td>38</td><td>75</td></tr><tr><td>2 (001)</td><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td>4 (010)</td><td></td><td></td><td></td><td></td><td></td><td></td><td></td><td></td></tr><tr><td>8 (011)</td><td colspan="7">Note: The current consumption can be calculated as the Measurement Rate * Current Consumption of 1 measurement per. sec.</td><td>n.a.</td></tr><tr><td>16 (100)</td><td></td><td></td><td></td><td></td><td></td><td></td><td>n.a.</td><td>n.a.</td></tr><tr><td>32 (101)</td><td></td><td></td><td></td><td></td><td></td><td>n.a.</td><td>n.a.</td><td>n.a.</td></tr><tr><td>64 (110)</td><td></td><td></td><td></td><td></td><td>n.a.</td><td>n.a.</td><td>n.a.</td><td>n.a.</td></tr><tr><td>128 (111)</td><td></td><td></td><td>n.a.</td><td>n.a.</td><td>n.a.</td><td>n.a.</td><td>n.a.</td><td>n.a.</td></tr></table>

Note: The table shows the possible combinations of Pressure Measurement Rate and oversampling when no temperature measurements are performed. When temperature measurements are performed the possible combinations are limited to Rate<sub>temperature</sub> x Measurement $T i m e _ { \mathrm { t e m p e r a t u r e } } + R a t e _ { \mathrm { p r e s s u r e } }$ x Measurement Time<sub>pressure</sub> < 1 second.

The temperature measurement time versus temperature oversampling rate is similar with pressure measurement time versus pressure oversampling rate

## Register description

## 8.4 Temperature Configuration(TMP\_CFG)

Configuration of temperature measurement rate (TMP\_RATE) and resolution (TMP\_PRC).

<table><tr><td colspan="2">TMP_CFG</td><td colspan="4">Address:</td><td> $07_{H}$ </td><td></td></tr><tr><td colspan="2">Temperature measurement configuration</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td><td></td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td>TMP_EXT</td><td colspan="3">TMP_RATE[2:0]</td><td colspan="4">TMP_PRC[2:0]</td></tr><tr><td>rw</td><td colspan="3">rw</td><td colspan="4">rw</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>TMP_EXT</td><td>7</td><td>rw</td><td>Temperature measurement0 - Internal sensor (in ASIC)1 - External sensor (in pressure sensor MEMS element)Note: It is highly recommended to use the same temperature sensor as the source of the calibration coefficients. Please see the Coefficient Source register</td></tr><tr><td>TMP_RATE[2:0]</td><td>6:4</td><td>rw</td><td>Temperature measurement rate:000 - 1 measurement pr. sec.001 - 2 measurements pr. sec.010 - 4 measurements pr. sec.011 - 8 measurements pr. sec.100 - 16 measurements pr. sec.101 - 32 measurements pr. sec.110 - 64 measurements pr. sec.111 - 128 measurements pr. sec..Applicable for measurements in Background mode only</td></tr><tr><td>TMP_PRC[2:0]</td><td>3:0</td><td>rw</td><td>Temperature oversampling (precision):0000 - single. (Default) - Measurement time 3.6 ms.Note: Following are optional, and may not be relevant:0001 - 2 times.0010 - 4 times.0011 - 8 times.0100 - 16 times.0101 - 32 times.0110 - 64 times..0111 - 128 times.1xxx - Reserved.</td></tr></table>

## Register description

## 8.5 Sensor Operating Mode and Status (MEAS\_CFG)

Setup measurement mode.

<table><tr><td colspan="3">MEAS_CFG</td><td colspan="3">Address:</td><td>08H</td><td></td></tr><tr><td colspan="3">Measurement configuration</td><td colspan="3">Reset value:</td><td>C0H</td><td></td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td>COEF_RDY</td><td>SENSOR_RDY</td><td>TMP_RDY</td><td>PRS_RDY</td><td>-</td><td colspan="3">MEAS_CTRL</td></tr><tr><td>r</td><td>r</td><td>r</td><td>r</td><td>-</td><td colspan="3">rw</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>COEF_RDY</td><td>7</td><td>r</td><td>Coefficients will be read to the Coefficients Registers after start-up:0 - Coefficients are not available yet.1 - Coefficients are available.</td></tr><tr><td>SENSOR_RDY</td><td>6</td><td>r</td><td>The pressure sensor is running through self initialization after start-up.0 - Sensor initialization not complete1 - Sensor initialization completeIt is recommend not to start measurements until the sensor has completed the self initialization.</td></tr><tr><td>TMP_RDY</td><td>5</td><td>r</td><td>Temperature measurement ready1 - New temperature measurement is ready. Cleared when temperature measurement is read.</td></tr><tr><td>PRS_RDY</td><td>4</td><td>r</td><td>Pressure measurement ready1 - New pressure measurement is ready. Cleared when pressure measurement is read.</td></tr><tr><td>-</td><td>3</td><td>-</td><td>Reserved.</td></tr><tr><td>MEAS_CTRL</td><td>2:0</td><td>rw</td><td>Set measurement mode and type:Standby Mode000 - Idle / Stop background measurementCommand Mode001 - Pressure measurement010 - Temperature measurement011 - na.100 - na.Background Mode101 - Continuous pressure measurement110 - Continuous temperature measurement111 - Continuous pressure and temperature measurement</td></tr></table>

## Register description

## 8.6 Interrupt and FIFO configuration (CFG\_REG)

Configuration of interupts, measurement data shift, and FIFO enable.

<table><tr><td colspan="3">CFG_REG</td><td colspan="4">Address:</td><td>09H</td></tr><tr><td colspan="3">Configuration register</td><td colspan="4">Reset value:</td><td>00H</td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td>INT_HL</td><td>INT_FIFO</td><td>INT_TMP</td><td>INT_PRS</td><td>T_SHIFT</td><td>P_SHIFT</td><td>FIFO_EN</td><td>SPI_MODE</td></tr><tr><td>rw</td><td>rw</td><td>rw</td><td>rw</td><td>rw</td><td>rw</td><td>rw</td><td>rw</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>INT_HL</td><td>7</td><td>rw</td><td>Interrupt (on SDO pin) active level:0 - Active low.1 - Active high.</td></tr><tr><td>INT_FIFO</td><td>6</td><td>rw</td><td>Generate interrupt when the FIFO is full:0 - Disable.1 - Enable.</td></tr><tr><td>INT_TMP</td><td>5</td><td>rw</td><td>Generate interrupt when a temperature measurement is ready:0 - Disable.1 - Enable.</td></tr><tr><td>INT_PRS</td><td>4</td><td>rw</td><td>Generate interrupt when a pressure measurement is ready:0 - Disable.1 - Enable.</td></tr><tr><td>T_SHIFT</td><td>3</td><td>rw</td><td>Temperature result bit-shift0 - no shift.1 - shift result right in data register.Note: Must be set to &#x27;1&#x27; when the oversampling rate is &gt;8 times.</td></tr><tr><td>P_SHIFT</td><td>2</td><td>rw</td><td>Pressure result bit-shift0 - no shift.1 - shift result right in data register.Note: Must be set to &#x27;1&#x27; when the oversampling rate is &gt;8 times.</td></tr><tr><td>FIFO_EN</td><td>1</td><td>rw</td><td>Enable the FIFO:0 - Disable.1 - Enable.</td></tr><tr><td>SPI_MODE</td><td>0</td><td>rw</td><td>Set SPI mode:0 - 4-wire interface.1 - 3-wire interface.</td></tr></table>

## Register description

## 8.7 Interrupt Status (INT\_STS)

Interrupt status register. The register is cleared on read.

<table><tr><td>INT_STS</td><td colspan="4">Address:</td><td> $0A_{H}$ </td></tr><tr><td>Interrupt status</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td></tr><tr><td></td><td colspan="3">-</td><td>INT_FIFO_FULL</td><td>INT_TMP</td></tr><tr><td></td><td colspan="3">-</td><td>r</td><td>r</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>-</td><td>7:3</td><td>-</td><td>Reserved.</td></tr><tr><td>INT_FIFO_FULL</td><td>2</td><td>r</td><td>Status of FIFO interrupt0 - Interrupt not active1 - Interrupt active</td></tr><tr><td>INT_TMP</td><td>1</td><td>r</td><td>Status of temperature measurement interrupt0 - Interrupt not active1 - Interrupt active</td></tr><tr><td>INT_PRS</td><td>0</td><td>r</td><td>Status of pressure measurement interrupt0 - Interrupt not active1 - Interrupt active</td></tr></table>

## Register description

## 8.8

## FIFO Status (FIFO\_STS)

FIFO status register

<table><tr><td>FIFO_STS</td><td>Address:</td><td> $0B_{H}$ </td></tr><tr><td>FIFO status register</td><td>Reset value:</td><td> $00_{H}$ </td></tr></table>

<table><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="2"></td><td colspan="4">-</td><td>FIFO_FULL</td><td>FIFO_EMPTY</td></tr></table>

<table><tr><td colspan="2">Field</td><td colspan="4">Bits</td><td>Type</td><td>Description</td></tr><tr><td colspan="2">-</td><td colspan="4">7:2</td><td>-</td><td>Reserved.</td></tr><tr><td colspan="2">FIFO_FULL</td><td colspan="4">1</td><td>r</td><td>0 - The FIFO is not full1 - The FIFO is full</td></tr><tr><td colspan="2">FIFO_EMPTYRESET</td><td colspan="4">0Address:</td><td>r</td><td>0 - The FIFO is not empty1 - The FIFO is empty</td></tr><tr><td colspan="2"></td><td colspan="4"></td><td> $0C_{H}$ </td><td></td></tr><tr><td colspan="2">FIFO flush and soft reset</td><td colspan="4">Reset value:</td><td> $00_{H}$ </td><td></td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td>FIFO_FLUSH</td><td colspan="3">-</td><td colspan="4">SOFT_RST</td></tr><tr><td>w</td><td colspan="3">-</td><td colspan="4">w</td></tr></table>

## Register description

## 8.9

## Soft Reset and FIFO flush (RESET)

Flush FIFO or generate soft reset.

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>FIFO_FLUSH</td><td>7</td><td>w</td><td>FIFO flush1 - Empty FIFOAfter reading out all data from the FIFO, write &#x27;1&#x27; to clear all old data.</td></tr><tr><td>-</td><td>6:4</td><td>-</td><td>Reserved.</td></tr><tr><td>SOFT_RST</td><td>3:0</td><td>w</td><td>Write &#x27;1001&#x27; to generate a soft reset. A soft reset will run though the same sequences as in power-on reset.</td></tr></table>

## 8.10 Product and Revision ID (ID)

Product and Revision ID.

<table><tr><td>ID</td><td>Address:</td><td> $0D_{H}$ </td></tr><tr><td>Product and revision ID</td><td>Reset value:</td><td> $0x10_{H}$ </td></tr></table>

<table><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td colspan="4">REV_ID</td><td colspan="4">PROD_ID</td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>REV_ID</td><td>7:4</td><td>r</td><td>Revision ID</td></tr><tr><td>PROD_ID</td><td>3:0</td><td>r</td><td>Product ID</td></tr></table>

## Register description

## 8.11 Calibration Coeficients (COEF)

The Calibration Coeficients register contains the 2´s complement coeficients that are used to calculate the compensated pressure and temperature values.

Table 18 Calibration Coeficients

<table><tr><td>Coefficient</td><td>Addr.</td><td>bit7</td><td>bit6</td><td>bit5</td><td>bit4</td><td>bit3</td><td>bit2</td><td>bit1</td><td>bit0</td></tr><tr><td>c0</td><td>0x10</td><td colspan="8">c0 [11:4]</td></tr><tr><td>c0/c1</td><td>0x11</td><td colspan="4">c0 [3:0]</td><td colspan="4">c1 [11:8]</td></tr><tr><td>c1</td><td>0x12</td><td colspan="8">c1[7:0]</td></tr><tr><td>c00</td><td>0x13</td><td colspan="8">c00 [19:12]</td></tr><tr><td>c00</td><td>0x14</td><td colspan="8">c00 [11:4]</td></tr><tr><td>c00/c10</td><td>0x15</td><td colspan="4">c00 [3:0]</td><td colspan="4">c10 [19:16]</td></tr><tr><td>c10</td><td>0x16</td><td colspan="8">c10 [15:8]</td></tr><tr><td>c10</td><td>0x17</td><td colspan="8">c10 [7:0]</td></tr><tr><td>c01</td><td>0x18</td><td colspan="8">c01 [15:8]</td></tr><tr><td>c01</td><td>0x19</td><td colspan="8">c01 [7:0]</td></tr><tr><td>c11</td><td>0x1A</td><td colspan="8">c11 [15:8]</td></tr><tr><td>c11</td><td>0x1B</td><td colspan="8">c11 [7:0]</td></tr><tr><td>c20</td><td>0x1C</td><td colspan="8">c20 [15:8]</td></tr><tr><td>c20</td><td>0x1D</td><td colspan="8">c20 [7:0]</td></tr><tr><td>c21</td><td>0x1E</td><td colspan="8">c21 [15:8]</td></tr><tr><td>c21</td><td>0x1F</td><td colspan="8">c21 [7:0]</td></tr><tr><td>c30</td><td>0x20</td><td colspan="8">c30 [15:8]</td></tr><tr><td>c30</td><td>0x21</td><td colspan="8">c30 [7:0]</td></tr></table>

Note: Generate the decimal numbers out of the calibration coeficients registers data:  
C20 := reg0x1D + reg0x1C \* 2^ 8

if (C20 > (2^15 - 1))

end if

```lisp
C0 := (reg0x10 * 2^4) + ((reg0x11 / 2^4) & 0x0F)
```

if (C0 > (2^11 - 1))

```txt
C0 := C0 - 2^12
```

end if

## Package Dimensions

## 8.12 Coeficient Source

States which internal temperature sensor the calibration coeficients are based on: the ASIC temperature sensor or the MEMS element temperature sensor. The coeficients are only valid for one sensor and it is highly recommended to use the same temperature sensor in the application. This is set-up in the Temperature Configuration register.

<table><tr><td colspan="2">TMP_COEF_SRCE</td><td colspan="5">Address:</td><td> $28_{H}$ </td></tr><tr><td colspan="2">Temperature Coefficients Source</td><td colspan="5">Reset value:</td><td> $XX_{H}$ </td></tr><tr><td>7</td><td>6</td><td>5</td><td>4</td><td>3</td><td>2</td><td>1</td><td>0</td></tr><tr><td>TMP_COEF_SRCE</td><td></td><td></td><td>-</td><td></td><td></td><td></td><td></td></tr></table>

<table><tr><td>Field</td><td>Bits</td><td>Type</td><td>Description</td></tr><tr><td>TMP_COEF_SRCE</td><td>7</td><td>r</td><td>Temperature coefficients are based on:0 - Internal temperature sensor (of ASIC)1 - External temperature sensor (of pressure sensor MEMS element)</td></tr><tr><td>-</td><td>6:0</td><td>-</td><td>Reserved</td></tr></table>

## 9 Package Dimensions

The sensor package is a 8-pin PG-VLGA-8-1, 2.0 x 2.5 x 1 mm<sup>3</sup>, with 0.65 mm pitch.

## 10 Package Handling

Further Information please refer to the attached “Digital Barometric Pressure Sensor\_ Package Handling”. It describes the package handling and delivery format.

## 11 Reflow soldering and board assembly

The Infineon pressure sensors are qualified in accordance with the IPC/JEDEC J-STD-020D-01. The moisture sensitivity level of pressure sensor is rated as MSL1. For PCB assembly of the sensor the widely used reflow soldering using a forced convection oven is recommended.

The soldering profile should be in accordance with the recommendations of the solder paste manufacturer to reach an optimal solder joint quality. The reflow profile shown in figure below is recommended for board manufacturing with Infineon pressure sensors.

Figure 17

## Reflow soldering and board assembly

![](https://www.embedr.app/api/datasheets/ds_88666e8763a513a1608e/asset?path=images%2F7136a8d67d8e9fec06ff45f6f88f1fb94a59e7400dbb6625fc1f1c2b13a409ec.jpg)

Table 19 Reflow profile limits

<table><tr><td>Profile feature</td><td>Pb-Free assembly</td><td>Sn-Pb Eutectic assembly</td></tr><tr><td colspan="3">Preheat/Soak</td></tr><tr><td>Temperature Min ( $T_{smin}$ )</td><td>150 °C</td><td>100 °C</td></tr><tr><td>Temperature Max ( $T_{smax}$ )</td><td>200 °C</td><td>150 °C</td></tr><tr><td>Time ( $T_{smin}$  to  $T_{smax}$ ) ( $t_s$ )</td><td>60-120 seconds</td><td>60-150 seconds</td></tr><tr><td>Peak Temperature ( $T_p$ )</td><td>260°C +0°C/-5°C</td><td>235°C +0°C/-5°C</td></tr><tr><td>Time within 5°C of actual peak temperature (tp)*</td><td>20-40 seconds</td><td>10-30 seconds</td></tr><tr><td>Ramp-down rate</td><td>6 °C/second max.</td><td>6 °C/second max.</td></tr><tr><td>Time 25°C to peak temperature</td><td>8 minutes max.</td><td>6 minutes max.</td></tr><tr><td colspan="2">* Tolerance for peak profile temperature ( $T_p$ ) is defined as a supplier minimum and a user maximum</td><td></td></tr></table>

Note: For further information please consult the 'General recommendation for assembly of Infineon packages' document which is available on the Infineon Technologies web page

## Revision History

The Infineon pressure sensors can be handled using industry standard pick and place equipment. Care should be taken to avoid damage to the sensor structure as follows:

• Do not pick the sensor with vacuum tools which make contact with the sensor vent port hole

• The sensor's vent hole should not be exposed to vacuum, this can destroy or damage the MEMS

Do not blow air into the sensor vent hole. If an air blow cleaning process is used, the vent hole must be sealed to prevent particle contamination.

• It is recommended to perform the PCB assembly in a clean room environment in order to avoid sensor contamination.

Air blow and ultrasonic cleaning procedures shall not be applied to MEMS pressure sensors. A non-clean paste is recommended for the assembly to avoid subsequent cleaning steps. The MEMS sensor can be severely damaged by cleaning substances.

• To prevent the blocking or partial blocking of vent hole during PCB assembly, it is recommended to cover the sound port with protective tape during PCB sawing or system assembly.

Do not use excessive force to place the sensor on the PCB. The use of industry standard pick and place tools is recommended in order to limit the mechanical force exerted to the package.

## Revision History

Major changes since previous revision

<table><tr><td colspan="3">Revision History</td></tr><tr><td>Reference</td><td></td><td>Description</td></tr><tr><td>1.0</td><td></td><td>Initial released</td></tr><tr><td>1.1</td><td></td><td>Title update; table 7 update; add reflow soldering chapter</td></tr><tr><td>1.2</td><td></td><td>Package dimensions typo fix</td></tr></table>

## Known Issues List

<table><tr><td colspan="2">Known Issues</td></tr><tr><td>Product and Revision ID</td><td>Description</td></tr><tr><td></td><td></td></tr></table>

## Trademarks

All referenced product or service names and trademarks are the property of their respective owners.

Edition 2020-10-15 Published by Infineon Technologies AG 81726 Munich, Germany

© 2020 Infineon Technologies AG All Rights Reserved.

Do you have a question about any aspect of this document? Email: erratum@infineon.com

Document reference IFX-sch1406115644540

## IMPORTANT NOTICE

The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics (“Beschafenheitsgarantie”) .

With respect to any examples, hints or any typical values stated herein and/or any information regarding the application of the product, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party.

In addition, any information given in this document is subject to customer’s compliance with its obligations stated in this document and any applicable legal requirements, norms and standards concerning customer’s products and any use of the product of Infineon Technologies in customer’s applications.

The data contained in this document is exclusively intended for technically trained staf. It is the responsibility of customer’s technical departments to evaluate the suitability of the product for the intended application and the completeness of the product information given in this document with respect to such application.

## WARNINGS

Due to technical requirements products may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies ofice.

Except as otherwise explicitly approved by Infineon Technologies in a written document signed by authorized representatives of Infineon Technologies, Infineon Technologies’ products may not be used in any applications where a failure of the product or any consequences of the use thereof can reasonably be expected to result in personal injury.