{"datasheetId":"ds_d3b538c1781b9424f70d","chunkCount":26,"revision":"2026-11-09T19:44:12.982Z","source":"index","nextCursor":null,"chunks":[{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0001","chunkIndex":0,"heading":"A Miniature Power Relay with 1-pole 10A Switching Capacity","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity"],"preview":"A Miniature Power Relay with 1 pole 10A Switching Capacity • Excellent switching performance for a variety of loads. • Small, yet provides 8 kV impulse withstand voltage (between coil and contacts). • Low coil power consumption (SPST NO: 20","images":[{"path":"images/04c7ce1ac314f7d389ceda6f2284e96f699f35e424581a137cdfc040bbcfa87c.jpg","name":"04c7ce1ac314f7d389ceda6f2284e96f699f35e424581a137cdfc040bbcfa87c.jpg","mimeType":"image/jpeg","semanticKind":"photo","semanticCaption":"Photographs of black relay components with certification marks.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F04c7ce1ac314f7d389ceda6f2284e96f699f35e424581a137cdfc040bbcfa87c.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0001"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0002","chunkIndex":1,"heading":"RoHS Compliant","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","RoHS Compliant"],"preview":"RoHS Compliant ■Model Number Legend 1. Number of Poles 1 : 1 pole 4. Classification None : Standard 2. Contact Form EU : High capacity None : SPDT (1c) 5. Market Code A : SPST NO (1a) 3. Enclosure Rating None : Flux protection 4 : Sealed No","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0002"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0003","chunkIndex":2,"heading":"■Application Examples","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Application Examples"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0003"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0004","chunkIndex":3,"heading":"■Application Examples","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Application Examples"],"preview":"Note 1. When ordering, add the rated coil voltage to the model number. Example: G5Q 1A DC5 Rated coil voltage Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube). ■Ratings ●Coil","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0004"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0005","chunkIndex":4,"heading":"■Ratings","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Ratings"],"preview":"Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum v","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0005"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0006","chunkIndex":5,"heading":"●Contacts","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","●Contacts"],"preview":"●Contacts","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0006"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0007","chunkIndex":6,"heading":"●Contacts","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","●Contacts"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0007"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0008","chunkIndex":7,"heading":"●Contacts","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","●Contacts"],"preview":"Note. Note. Values in the above table are the initial values at 23°C. \\ 1. The contact resistance is possible with 1 A applied at 5 VDC using a fall of potential method. \\ 3. This value was measured at a switching frequency of 120 operation","images":[{"path":"images/88eae0f1c1659ac18aa078ba2ae0a5372fb1abe697cedd63c787eef217bd1ca4.jpg","name":"88eae0f1c1659ac18aa078ba2ae0a5372fb1abe697cedd63c787eef217bd1ca4.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"G5Q relay package dimensions, mounting holes, and terminal arrangement","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F88eae0f1c1659ac18aa078ba2ae0a5372fb1abe697cedd63c787eef217bd1ca4.jpg"},{"path":"images/34c40a4ee969f9d3731ca88ba6c9bb4ace1fee3c7e4d66b7ec4b9df842b7f5b9.jpg","name":"34c40a4ee969f9d3731ca88ba6c9bb4ace1fee3c7e4d66b7ec4b9df842b7f5b9.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Standard switching current versus switching voltage","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F34c40a4ee969f9d3731ca88ba6c9bb4ace1fee3c7e4d66b7ec4b9df842b7f5b9.jpg"},{"path":"images/e6d461e471761f526dc948213e5e9e9dd79712ae0ca2a62285159d9447206f24.jpg","name":"e6d461e471761f526dc948213e5e9e9dd79712ae0ca2a62285159d9447206f24.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Standard maximum coil voltage versus ambient temperature","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fe6d461e471761f526dc948213e5e9e9dd79712ae0ca2a62285159d9447206f24.jpg"},{"path":"images/02a4dcf7a82ead02902f5eae76e610af3b4d223f72568013c79e072b8f7234b9.jpg","name":"02a4dcf7a82ead02902f5eae76e610af3b4d223f72568013c79e072b8f7234b9.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Three-axis contact acceleration comparison chart","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F02a4dcf7a82ead02902f5eae76e610af3b4d223f72568013c79e072b8f7234b9.jpg"},{"path":"images/1783ef1b4e99b9696dc5143309aed32f512cb286ce4084b89508cd7df61d0326.jpg","name":"1783ef1b4e99b9696dc5143309aed32f512cb286ce4084b89508cd7df61d0326.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"Switching current versus load characteristics for high-capacity (-EU) contacts","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F1783ef1b4e99b9696dc5143309aed32f512cb286ce4084b89508cd7df61d0326.jpg"},{"path":"images/674d40b6485660e7cfd3b3dc46c19eecb3707d8edc9d361d9c8e6a8d3a778c03.jpg","name":"674d40b6485660e7cfd3b3dc46c19eecb3707d8edc9d361d9c8e6a8d3a778c03.jpg","mimeType":"image/jpeg","semanticKind":"graph_chart","semanticCaption":"High-capacity EU maximum coil voltage versus ambient temperature","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F674d40b6485660e7cfd3b3dc46c19eecb3707d8edc9d361d9c8e6a8d3a778c03.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0008"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0009","chunkIndex":8,"heading":"●Contacts","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","●Contacts"],"preview":"Sample: G5Q 14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. The energized voltage is 100% of the r","images":[{"path":"images/b6ddb6e5af74214868ac5d9a424bdd3180388e9ff0f4198d3f2b3fa5a5052273.jpg","name":"b6ddb6e5af74214868ac5d9a424bdd3180388e9ff0f4198d3f2b3fa5a5052273.jpg","mimeType":"image/jpeg","semanticKind":"package_drawing","semanticCaption":"G5Q-1A relay package dimensions, PCB mounting holes, and terminal arrangement.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fb6ddb6e5af74214868ac5d9a424bdd3180388e9ff0f4198d3f2b3fa5a5052273.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0009"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0010","chunkIndex":9,"heading":"■Approved Standards","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Approved Standards"],"preview":"■Approved Standards UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0010"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0011","chunkIndex":10,"heading":"EN/IEC, VDE (Certified/No.40009467)","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","EN/IEC, VDE (Certified/No.40009467)"],"preview":"EN/IEC, VDE (Certified/No.40009467)","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0011"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0012","chunkIndex":11,"heading":"EN/IEC, VDE (Certified/No.40009467)","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","EN/IEC, VDE (Certified/No.40009467)"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0012"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0013","chunkIndex":12,"heading":"EN/IEC, VDE (Certified/No.40009467)","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","EN/IEC, VDE (Certified/No.40009467)"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0013"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0014","chunkIndex":13,"heading":"■Precautions","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Precautions"],"preview":"■Precautions ●Please refer to “PCB Relays Common Precautions” for correct use. Correct Use ●Coil Voltage Reduction (Holding Voltage) after Relay operation • If the coil voltage is reduced to the holding voltage after relay operation, first","images":[{"path":"images/61992597c1c0e3ba52d4530a29cdc5623c16b0a6fcbb97639be06ac8e7349d7b.jpg","name":"61992597c1c0e3ba52d4530a29cdc5623c16b0a6fcbb97639be06ac8e7349d7b.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"Applied coil voltage timing waveform","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F61992597c1c0e3ba52d4530a29cdc5623c16b0a6fcbb97639be06ac8e7349d7b.jpg"},{"path":"images/a3a5dec6bd78a4fbe36d8f736b6fd57d70792100dce54bdd71d1e2e42bce833e.jpg","name":"a3a5dec6bd78a4fbe36d8f736b6fd57d70792100dce54bdd71d1e2e42bce833e.jpg","mimeType":"image/jpeg","semanticKind":"timing_diagram","semanticCaption":"Coil voltage reduction timing waveform","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fa3a5dec6bd78a4fbe36d8f736b6fd57d70792100dce54bdd71d1e2e42bce833e.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0014"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0015","chunkIndex":14,"heading":"■Precautions","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","■Precautions"],"preview":"","images":[],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0015"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0016","chunkIndex":15,"heading":"OMRON Corporation Electronic and Mechanical Components Company","headingPath":["A Miniature Power Relay with 1-pole 10A Switching Capacity","OMRON Corporation Electronic and Mechanical Components Company"],"preview":"OMRON Corporation Electronic and Mechanical Components Company ●Power consumption reduction of coil with pulse width modulation (PWM) • Models with PWM drive capability ( PW) can reduce coil holding current with PWM control. This function r","images":[{"path":"images/ad7c5c7a756e2f996665d2cebaa7c81bae279c89238c9c32b1b86abab2e57db4.jpg","name":"ad7c5c7a756e2f996665d2cebaa7c81bae279c89238c9c32b1b86abab2e57db4.jpg","mimeType":"image/jpeg","semanticKind":"schematic","semanticCaption":"Relay coil MOS-FET drive circuit with surge absorption diode","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fad7c5c7a756e2f996665d2cebaa7c81bae279c89238c9c32b1b86abab2e57db4.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0016"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0017","chunkIndex":16,"heading":"Extracted datasheet image 1: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Coil voltage, resistance, and power consumption table","images":[{"path":"images/c604479b4e0209616c25f76d131da8190c60b4a0636cc27a1a6a3214dbb2786e.jpg","name":"c604479b4e0209616c25f76d131da8190c60b4a0636cc27a1a6a3214dbb2786e.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Coil voltage, resistance, and power consumption table","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fc604479b4e0209616c25f76d131da8190c60b4a0636cc27a1a6a3214dbb2786e.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0017"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0018","chunkIndex":17,"heading":"Extracted datasheet image 2: unknown","headingPath":["Extracted datasheet images","unknown"],"preview":"G5Q relay model selection table","images":[{"path":"images/02de6909bcec8c37f08035fc547b2fa40306fa64a2f5bf5292dba0696c72f3b6.jpg","name":"02de6909bcec8c37f08035fc547b2fa40306fa64a2f5bf5292dba0696c72f3b6.jpg","mimeType":"image/jpeg","semanticKind":"unknown","semanticCaption":"G5Q relay model selection table","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F02de6909bcec8c37f08035fc547b2fa40306fa64a2f5bf5292dba0696c72f3b6.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0018"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0019","chunkIndex":18,"heading":"Extracted datasheet image 3: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"G5Q relay coil and contact ratings table","images":[{"path":"images/3d00c2bcca059af8d0efa102cf83de485bd1c4b9d2b840d413643ff89436cb26.jpg","name":"3d00c2bcca059af8d0efa102cf83de485bd1c4b9d2b840d413643ff89436cb26.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"G5Q relay coil and contact ratings table","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F3d00c2bcca059af8d0efa102cf83de485bd1c4b9d2b840d413643ff89436cb26.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0019"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0020","chunkIndex":19,"heading":"Extracted datasheet image 4: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Relay performance, durability, environmental, and operating specifications.","images":[{"path":"images/5033a703f35285d4ea0ecbb5f9d554992bda1e7f5c1c7074909f84ca13d0641c.jpg","name":"5033a703f35285d4ea0ecbb5f9d554992bda1e7f5c1c7074909f84ca13d0641c.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Relay performance, durability, environmental, and operating specifications.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F5033a703f35285d4ea0ecbb5f9d554992bda1e7f5c1c7074909f84ca13d0641c.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0020"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0021","chunkIndex":20,"heading":"Extracted datasheet image 5: text snippet","headingPath":["Extracted datasheet images","text snippet"],"preview":"Omron regional contact websites.","images":[{"path":"images/315300e3e0c643573c8e148ab74a4a2363365162bf2531c87468d631b1d7e3a5.jpg","name":"315300e3e0c643573c8e148ab74a4a2363365162bf2531c87468d631b1d7e3a5.jpg","mimeType":"image/jpeg","semanticKind":"text_snippet","semanticCaption":"Omron regional contact websites.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F315300e3e0c643573c8e148ab74a4a2363365162bf2531c87468d631b1d7e3a5.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0021"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0022","chunkIndex":21,"heading":"Extracted datasheet image 6: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Relay coil and contact ratings for SPST-NO and SPDT configurations.","images":[{"path":"images/ee5dee7196d16f024a4a7327f2419831d902c0be4609d5e7b943937a750917e8.jpg","name":"ee5dee7196d16f024a4a7327f2419831d902c0be4609d5e7b943937a750917e8.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Relay coil and contact ratings for SPST-NO and SPDT configurations.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fee5dee7196d16f024a4a7327f2419831d902c0be4609d5e7b943937a750917e8.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0022"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0023","chunkIndex":22,"heading":"Extracted datasheet image 7: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Relay insulation, spacing, safety, and material specifications.","images":[{"path":"images/6e28114ab3318e8ca6b8adc3f1791f2c7b33c84a2fee3c407251f92875d8b203.jpg","name":"6e28114ab3318e8ca6b8adc3f1791f2c7b33c84a2fee3c407251f92875d8b203.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Relay insulation, spacing, safety, and material specifications.","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F6e28114ab3318e8ca6b8adc3f1791f2c7b33c84a2fee3c407251f92875d8b203.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0023"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0024","chunkIndex":23,"heading":"Extracted datasheet image 8: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Applied coil voltage, coil resistance, and power consumption table","images":[{"path":"images/595be8131af7263eaa4ee657f1c1b455c77b4e00fb7dc4c009e771000c569d4b.jpg","name":"595be8131af7263eaa4ee657f1c1b455c77b4e00fb7dc4c009e771000c569d4b.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Applied coil voltage, coil resistance, and power consumption table","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F595be8131af7263eaa4ee657f1c1b455c77b4e00fb7dc4c009e771000c569d4b.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0024"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0025","chunkIndex":24,"heading":"Extracted datasheet image 9: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Relay model, coil, contact ratings, and test operations table","images":[{"path":"images/e3e10dc79376ac059290d1b490b3373ed607126b9de10551ad4144bc10090102.jpg","name":"e3e10dc79376ac059290d1b490b3373ed607126b9de10551ad4144bc10090102.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Relay model, coil, contact ratings, and test operations table","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fe3e10dc79376ac059290d1b490b3373ed607126b9de10551ad4144bc10090102.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0025"},{"chunkId":"ds_d3b538c1781b9424f70d-chunk-0026","chunkIndex":25,"heading":"Extracted datasheet image 10: electrical table","headingPath":["Extracted datasheet images","electrical table"],"preview":"Resistive-load contact ratings and switching specifications","images":[{"path":"images/e57b4ea39f362ce2b610b552eb42b85ada4d0a8532918994192aa55f03d09e44.jpg","name":"e57b4ea39f362ce2b610b552eb42b85ada4d0a8532918994192aa55f03d09e44.jpg","mimeType":"image/jpeg","semanticKind":"electrical_table","semanticCaption":"Resistive-load contact ratings and switching specifications","viewUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fe57b4ea39f362ce2b610b552eb42b85ada4d0a8532918994192aa55f03d09e44.jpg"}],"readUrl":"https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/chunks/ds_d3b538c1781b9424f70d-chunk-0026"}]}