## A Miniature Power Relay with 1-pole 10A Switching Capacity

• Excellent switching performance for a variety of loads.

• Small, yet provides 8-kV impulse withstand voltage (between coil and contacts).

• Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)

• Coil insulation system: Class F (UL1446).

• IEC/EN 60335-1 conformed. (-HA Model)

• Reduced power consumption with voltage holding and pulse width modulation (PWM) control (Only for G5Q-@-PW model)

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F04c7ce1ac314f7d389ceda6f2284e96f699f35e424581a137cdfc040bbcfa87c.jpg)

## RoHS Compliant

## ■Model Number Legend

1. Number of Poles 1 : 1-pole

4. Classification

None : Standard

2. Contact Form

EU : High-capacity

None : SPDT (1c)

5. Market Code

A : SPST-NO (1a)

3. Enclosure Rating

None : Flux protection 4 : Sealed

None : General purpose HA : Home Appliance according to IEC/EN60335-1

None : Not supported

6. Special Requirement

PW : Supported

## ■Application Examples

• Ideal for output applications of control equipment.

■Ordering Information

<table><tr><td>Terminal Shape</td><td>Market Code</td><td>Classification</td><td>Contact Form</td><td>Enclosure Rating</td><td>Model</td><td>Rated Coil Voltage</td><td>Minimum Packing Unit</td></tr><tr><td rowspan="16">PCB terminals</td><td rowspan="10">General purpose</td><td rowspan="6">Standard</td><td rowspan="3">SPST-NO(1a)</td><td rowspan="2">Flux protection</td><td>G5Q-1A</td><td>5VDC9VDC12VDC24VDC</td><td rowspan="16">100 pcs/tray</td></tr><tr><td>G5Q-1A-PW</td><td>5VDC12VDC24VDC</td></tr><tr><td>Sealed</td><td>G5Q-1A4</td><td>5VDC9VDC12VDC24VDC</td></tr><tr><td rowspan="3">SPDT(1c)</td><td rowspan="2">Flux protection</td><td>G5Q-1</td><td>5VDC9VDC12VDC24VDC</td></tr><tr><td>G5Q-1-PW</td><td>5VDC12VDC24VDC</td></tr><tr><td>Sealed</td><td>G5Q-14</td><td>5VDC9VDC12VDC24VDC</td></tr><tr><td rowspan="4">High-capacity</td><td rowspan="2">SPST-NO(1a)</td><td>Flux protection</td><td>G5Q-1A-EU</td><td rowspan="4">5VDC12VDC24VDC</td></tr><tr><td>Sealed</td><td>G5Q-1A4-EU</td></tr><tr><td rowspan="2">SPDT(1c)</td><td>Flux protection</td><td>G5Q-1-EU</td></tr><tr><td>Sealed</td><td>G5Q-14-EU</td></tr><tr><td rowspan="6">Home Appliance</td><td rowspan="2">Standard</td><td rowspan="3">SPST-NO(1a)</td><td rowspan="6">Flux protection</td><td>G5Q-1A-HA</td><td rowspan="2">5VDC12VDC24VDC</td></tr><tr><td>G5Q-1A-HA-PW</td></tr><tr><td>High-capacity</td><td>G5Q-1A-EU-HA</td><td>12VDC24VDC</td></tr><tr><td rowspan="2">Standard</td><td rowspan="3">SPDT(1c)</td><td>G5Q-1-HA</td><td rowspan="2">5VDC12VDC24VDC</td></tr><tr><td>G5Q-1-HA-PW</td></tr><tr><td>High-capacity</td><td>G5Q-1-EU-HA</td><td>12VDC24VDC</td></tr></table>

Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G5Q-1A DC5  
Rated coil voltage  
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).

## ■Ratings

●Coil

<table><tr><td>Contact form</td><td>Rated voltage</td><td>Rated current (mA)</td><td>Coil resistance (Ω)</td><td>Must operate voltage (V)</td><td>Must release voltage (V)</td><td>Max. voltage (V)</td><td>Power consumption (mW)</td></tr><tr><td rowspan="4">SPST-NO (1a)</td><td>5 VDC</td><td>40</td><td>125</td><td rowspan="8">75% max.</td><td rowspan="4">5% min. 5 to 34%*</td><td rowspan="8">190% (at 23°C)</td><td rowspan="4">Approx. 200 Approx. 32*</td></tr><tr><td>9 VDC</td><td>22.2</td><td>405</td></tr><tr><td>12 VDC</td><td>16.7</td><td>720</td></tr><tr><td>24 VDC</td><td>8.3</td><td>2880</td></tr><tr><td rowspan="4">SPDT (1c)</td><td>5 VDC</td><td>80</td><td>63</td><td rowspan="4">5% min. 5 to 25%*</td><td rowspan="4">Approx. 400 Approx. 36*</td></tr><tr><td>9 VDC</td><td>44.4</td><td>202</td></tr><tr><td>12 VDC</td><td>33.3</td><td>360</td></tr><tr><td>24 VDC</td><td>16.7</td><td>1440</td></tr></table>

Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
\* Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage)

## ●Contacts

<table><tr><td rowspan="3">LoadItem</td><td colspan="4">Resistive load</td></tr><tr><td colspan="2">SPST-NO (1a)</td><td colspan="2">SPDT (1c)</td></tr><tr><td>Standard</td><td>High-capacity</td><td>Standard</td><td>High-capacity</td></tr><tr><td>Contact type</td><td colspan="4">Single</td></tr><tr><td>Contact material</td><td colspan="4">Ag-Alloy (Cd free)</td></tr><tr><td>Rated load(resistive)</td><td>10 A at 125 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC</td><td>10 A at 250 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC</td><td>10 A at 125 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC)</td><td>10 A at 250 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC)</td></tr><tr><td>Rated carry current</td><td colspan="4">10 A (NO)/3 A (NC)</td></tr><tr><td>Max. switching voltage</td><td colspan="4">277 VAC, 30 VDC</td></tr><tr><td>Max. switching current</td><td colspan="4">AC: 10 A (NO)/3 A (NC)DC: 5 A (NO)/3 A (NC)</td></tr></table>

■Characteristics

<table><tr><td colspan="2">Item Classification</td><td>Standard model</td></tr><tr><td colspan="2">Contact resistance *1</td><td>100 mΩ max.</td></tr><tr><td colspan="2">Operate time</td><td>10 ms max.</td></tr><tr><td colspan="2">Release time</td><td>5 ms max.</td></tr><tr><td colspan="2">Insulation resistance *2</td><td>1,000 MΩ min.</td></tr><tr><td rowspan="2">Dielectric strength</td><td>Between coil and contacts</td><td>4,000 VAC, 50/60 Hz for 1 min</td></tr><tr><td>Between contacts of the same polarity</td><td>1,000 VAC, 50/60 Hz for 1 min</td></tr><tr><td colspan="2">Impulse withstand voltage (between coil and contacts)</td><td>8 kV (1.2 x 50 μs)</td></tr><tr><td rowspan="2">Vibration resistance</td><td>Destruction</td><td>10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)</td></tr><tr><td>Malfunction</td><td>10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)</td></tr><tr><td rowspan="2">Shock resistance</td><td>Destruction</td><td>1,000 m/s2</td></tr><tr><td>Malfunction</td><td>100 m/s2</td></tr><tr><td rowspan="2">Durability</td><td>Mechanical</td><td>10,000,000 operations (18,000 operations per hour)</td></tr><tr><td>Electrical</td><td>NO25,000 operations: 10 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)50,000 operations: 10 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)50,000 operations: 5 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 5 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec)NC200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec)</td></tr><tr><td colspan="2">Failure rate (P level) (reference *3)</td><td>10 mA at 5 VDC</td></tr><tr><td colspan="2">Ambient operating temperature</td><td>-40°C to 105°C (with no icing or condensation)-40°C to 85°C (with no icing or condensation)</td></tr><tr><td colspan="2">Ambient operating humidity</td><td>5% to 85%</td></tr><tr><td colspan="2">Weight</td><td>Approx. 6.5 g</td></tr></table>

Note. Note. Values in the above table are the initial values at 23°C.  
\*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.  
\*3. This value was measured at a switching frequency of 120 operations/min.  
\*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F88eae0f1c1659ac18aa078ba2ae0a5372fb1abe697cedd63c787eef217bd1ca4.jpg)  
Switching voltgate (V)

●Shock Malfunction  
■Engineering Data  
●Maximum Switching Capacity  
![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F34c40a4ee969f9d3731ca88ba6c9bb4ace1fee3c7e4d66b7ec4b9df842b7f5b9.jpg)

●Ambient Temperature VS. Maximum Coil Voltage  
![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fe6d461e471761f526dc948213e5e9e9dd79712ae0ca2a62285159d9447206f24.jpg)

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F02a4dcf7a82ead02902f5eae76e610af3b4d223f72568013c79e072b8f7234b9.jpg)

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F1783ef1b4e99b9696dc5143309aed32f512cb286ce4084b89508cd7df61d0326.jpg)

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F674d40b6485660e7cfd3b3dc46c19eecb3707d8edc9d361d9c8e6a8d3a778c03.jpg)  
Sample: G5Q-14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. The energized voltage is 100% of the rated voltage. Requirement: None malfuction 100 m/s2  
Note. The Maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.

■Dimensions  
(Unit: mm)  
![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fb6ddb6e5af74214868ac5d9a424bdd3180388e9ff0f4198d3f2b3fa5a5052273.jpg)

## ■Approved Standards

## UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)

<table><tr><td>Model</td><td>Contact form</td><td>Coil ratings</td><td>Contact ratings</td><td>Number of test operations</td></tr><tr><td rowspan="5">G5Q-1A(4)(-EU)(-HA)(-PW)G5Q-1(4)(-EU)(-HA)(-PW)</td><td rowspan="5">SPST-NO (1a)SPDT (1c)</td><td rowspan="5">5 to 48 VDC</td><td>10 A 250 VAC N.O. only (Resistive) 40°C</td><td rowspan="2">6,000</td></tr><tr><td>10 A 30 VDC N.O. only (Resistive) 40°C</td></tr><tr><td>4 A 120 VAC N.O. only (Resistive) 40°C</td><td>100,000</td></tr><tr><td>3 A 250 VAC N.C. only (Resistive) 40°C</td><td rowspan="2">6,000</td></tr><tr><td>3 A 30 VDC N.C. only (Resistive) 40°C</td></tr></table>

## EN/IEC, VDE (Certified/No.40009467)

<table><tr><td>Model</td><td>Contact form</td><td>Coil ratings</td><td>Contact ratings</td><td>Number of test operations</td></tr><tr><td rowspan="2">G5Q-1(4)(-HA)(-PW)G5Q-1A(4)(-HA)(-PW)</td><td rowspan="4">SPST-NO (1a)SPDT (1c)</td><td rowspan="4">5 to 48 VDC</td><td>10 A making and 0 A breaking, 250 VAC ( $\cos\phi=1$ ) 105°C5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C</td><td>10,000</td></tr><tr><td>5 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 105°C</td><td>75,000</td></tr><tr><td rowspan="2">G5Q-1A(4)-EU(-HA)G5Q-1(4)-EU(-HA)</td><td>10 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 65°C5 A 30 VDC (0 ms) (N.O.) 65°C3 A 30 VDC (0 ms) (N.C.) 65°C</td><td>10,000</td></tr><tr><td>4 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 85°C</td><td>100,000</td></tr></table>

<table><tr><td>Creepage Distance</td><td>6.4 mm min.</td></tr><tr><td>Clearance Distance</td><td>5.5 mm min.</td></tr><tr><td>Insulation Material Group</td><td>IIIa</td></tr><tr><td>Type of Insulation Coil-contact CircuitOpen Contact Circuit</td><td>Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)Micro disconnection</td></tr><tr><td>Rated Insulation Voltage</td><td>250 V</td></tr><tr><td>Pollution Degree</td><td>2</td></tr><tr><td>Rated Voltage System</td><td>250 V / 400 V (EU flux type only)</td></tr><tr><td>Over Voltage Category</td><td>III</td></tr><tr><td>Category of Protection according to IEC 61810-1</td><td>RT II (Flux protection) / RT III (Sealed)</td></tr><tr><td>Glow Wire according to IEC 60335-1</td><td>&lt;HA Models only&gt;GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)</td></tr><tr><td>Tracking Index of Relay Base</td><td>PTI 250 V min. (housing parts)</td></tr><tr><td>Flammability Class according to UL94</td><td>V-0</td></tr><tr><td>Coil Insulation System</td><td>F Class (UL 1446)</td></tr></table>

<table><tr><td colspan="2">Regional Contact</td></tr><tr><td>Americas</td><td>Europe</td></tr><tr><td>https://www.components.omron.com/</td><td>http://components.omron.eu/</td></tr><tr><td>Asia-Pacific</td><td>China</td></tr><tr><td>https://ecb.omron.com.sg/</td><td>https://www.ecb.omron.com.cn/</td></tr><tr><td>Korea</td><td>Japan</td></tr><tr><td>https://www.omron-ecb.co.kr/</td><td>https://www.omron.co.jp/ecb/</td></tr></table>

© OMRON Corporation 2007-2021 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice.

## ■Precautions

●Please refer to “PCB Relays Common Precautions” for correct use.

Correct Use

●Coil Voltage Reduction (Holding Voltage) after Relay operation

• If the coil voltage is reduced to the holding voltage after relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below.

• A voltage of at least 40% (G5Q-1A type) /30% (G5Q-1 type) of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level.

G5Q-1A  
![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2F61992597c1c0e3ba52d4530a29cdc5623c16b0a6fcbb97639be06ac8e7349d7b.jpg)

G5Q-1  
![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fa3a5dec6bd78a4fbe36d8f736b6fd57d70792100dce54bdd71d1e2e42bce833e.jpg)  
G5Q-1A

<table><tr><td></td><td>Applied coil voltage</td><td>Coil resistance*</td><td>Power consumption</td></tr><tr><td>Rated voltage</td><td>100%</td><td rowspan="2">125Ω (5 VDC)720Ω (12 VDC)2,880Ω (24 VDC)</td><td>Approx. 200 mW</td></tr><tr><td>Holding voltage</td><td>40%</td><td>Approx. 32 mW</td></tr></table>

The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.

G5Q-1

<table><tr><td></td><td>Applied coil voltage</td><td>Coil resistance*</td><td>Power consumption</td></tr><tr><td rowspan="2">Rated voltage</td><td rowspan="2">100%</td><td>63Ω (5 VDC)</td><td rowspan="2">Approx. 400 mW</td></tr><tr><td>360Ω (12 VDC)</td></tr><tr><td>Holding voltage</td><td>30%</td><td>1,440Ω (24 VDC)</td><td>Approx. 36 mW</td></tr></table>

The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.  
■Example of drive circuit

Please check each region's Terms & Conditions by region website.

## OMRON Corporation Electronic and Mechanical Components Company

●Power consumption reduction of coil with pulse width modulation (PWM)

• Models with PWM drive capability (-PW) can reduce coil holding current with PWM control. This function reduces power consumption by reducing the current held by coil.

• Apply the rated voltage for at least 100 ms at the time of relay operation.

• The following are our verification conditions. When using, it be sure to check the actual machine under the actual usage conditions.

■Conditions of validation carried out by OMRON

![](https://www.embedr.app/api/datasheets/ds_d3b538c1781b9424f70d/asset?path=images%2Fad7c5c7a756e2f996665d2cebaa7c81bae279c89238c9c32b1b86abab2e57db4.jpg)

• Applied voltage: rated voltage

• Duty: 50% or more

• Frequency: 10 kHz or more

• Diode Vf: 0.4 V or less