BMP388 Digital pressure sensor
Digital barometric pressure and temperature sensor with low power consumption, integrated FIFO, and altitude tracking capability.
Bosch Sensortec BMP388 data sheet (BST-BMP388-DS001-07, revision 1.7, November 2020)
Faithful page-by-page text transcription (Poppler pdftotext -layout) of the Bosch Sensortec PDF https://www.bosch-sensortec.com/media/boschsensortec/downloads/datasheets/bst-bmp388-ds001.pdf (sha256 1ab21c90aaf15542751be6b970d53dc57893a4ea948f45f9fe96e844789fdec2). Pages that contain figures are attached as 110 dpi page renders (32-colour palette). Running headers/footers are omitted.
Page 1
BMP388
Digital pressure sensor
BMP388 – Datasheet
Document revision 1.7
Document release date November 2020
Document number BST-BMP388-DS001-07
Technical reference code(s) 0 273 300 511
Notes Data and descriptions in this document are subject to change without notice.
Product photos and pictures are for illustration purposes only and may differ
from the real product appearance.
Page 2
BMP388
Digital pressure sensor
The BMP388 is a digital sensor with pressure and temperature measurement based on proven sensing principles. The sensor
module is housed in an extremely compact 10-pin metal-lid LGA package with a footprint of only 2.0 × 2.0 mm² and max 0.8
mm package height. Its small dimensions and its low power consumption of 3.4 µA @1Hz allow the implementation in battery
driven devices such as mobile phones, GPS modules or watches.
Typical applications
• Vertical velocity indication (e.g. rise/sink speed)
• Internet of things
• Enhancement of GPS navigation
(e.g. time-to-first-fix improvement, dead-reckoning, slope detection)
• Indoor navigation & localization (floor detection, elevator detection)
• Outdoor navigation, leisure and sports applications
• Weather forecast
• Health care applications (e.g. spirometry)
• Fitness applications like enhancement of calorie detection
• AR & VR applications
• Context awareness
Target Devices
• Flying toys
• Drones
• Handsets such as mobile phones, tablet PCs, GPS devices
• Navigation systems
• Portable health care devices
• Home weather stations
• Watches
• White goods
Page 3
Key features
Table 1: Key Features of BMP388
Package 2.0 mm x 2.0 mm x 0.75 mm metal lid LGA
Digital interface I²C (up to 3.4 MHz) and SPI (3 and 4 wire, up to 10 MHz)
VDD main supply voltage range: 1.65 V to 3.6 V
Supply voltage
VDDIO interface voltage range: 1.2 V to 3.6 V
typ. ± 8 Pa, equiv. to ± 0.66 m
Relative accuracy
(900 … 1100 hPa, 25 . . . 40 °C )
typ. ± 50 Pa
Absolute accuracy
(300 ...1100 hPa, -20 ...+65 °C)
typ. ± 0.75 Pa/K
Temperature coefficient offset
(0 ... 55°C @700 -1100 hPa)
3.4 µA at 1 Hz pressure and temperature
Current consumption
2.0 µA in sleep mode
Operating range -40 ‒ +85 °C, 300‒1250 hPa
The product is RoHS compliant, halogen-free, MSL1
BMP388 enables accurate altitude tracking and is specifically suited for drone applications. The best-in-class TCO between
-20-65°C for accurate altitude measurement over a wide temperature range of the BMP388 greatly enhance the drone flying
experience by making accurate steering easier. It is compatible for use with other Bosch sensors, including the new BMI088
for better performance, robustness and stability. The new BMP388 sensor offers outstanding design flexibility, providing a
single package solution that can also be easily integrated into other existing and upcoming devices such as smart homes,
industrial products and wearables.
The sensor is more accurate than its predecessor BMP280, covering a wide measurement range from 300 hPa to 1250 hPa.
This new barometric pressure sensor exhibits an attractive price-performance ratio coupled with low power consumption.
It is available in a compact 10-in 2.0 x 2.0 x 0.75 mm³ LGA package with metal lid
Due to the built-in hardware synchronization of the pressure sensor data and its ability to synchronize data from external
devices such as acceleration sensors, the BMP388 is ideally suited for fitness and navigation applications which require
highly accurate, low power and low latency sensor data fusion.
The new interrupt functionality provides simple access to data and storage. Examples of interrupts than can be used in a
power efficient manner without using software algorithms include: Data ready interrupt, watermark interrupt (on byte level)
or FIFO full interrupt.
BMP388 also includes a new FIFO functionality. This greatly improves ease of use while helping to reduce power
consumption of the overall device system during full operation. The integrated 512 byte FIFO buffer supports low power
applications and prevents data loss in non-real-time systems.
Page 4
Table of Contents
1. Specification..................................................................................................................................................................... 7
2. Absolute maximum ratings ............................................................................................................................................. 9
3. Functional description .................................................................................................................................................... 9
3.1. Block diagram ......................................................................................................................................................... 10
3.2. Power management ................................................................................................................................................ 11
3.3. Power modes .......................................................................................................................................................... 11
3.3.1. Sleep mode ...................................................................................................................................................... 11
3.3.2. Forced mode ..................................................................................................................................................... 11
3.3.3. Normal mode ..................................................................................................................................................... 12
3.3.4. Mode transition diagram .................................................................................................................................... 13
3.4. Measurement flow .................................................................................................................................................. 13
3.4.1. Pressure measurement ..................................................................................................................................... 14
3.4.2. Temperature measurement ............................................................................................................................... 14
3.4.3. IIR filter .............................................................................................................................................................. 15
3.4.4. Oversampling .................................................................................................................................................... 15
3.5. Filter selection ........................................................................................................................................................ 17
3.6. FIFO Description ..................................................................................................................................................... 18
3.6.1. FIFO input data ................................................................................................................................................. 18
3.6.2. FIFO data sampling selection............................................................................................................................ 18
3.6.3. FIFO read out .................................................................................................................................................... 18
3.6.4. FIFO overflow behavior ..................................................................................................................................... 19
3.6.5. FIFO Frames ..................................................................................................................................................... 19
3.6.7. FIFO flush conditions ........................................................................................................................................ 21
3.7. Interrupts ................................................................................................................................................................. 22
3.7.1. Interrupt default mode ....................................................................................................................................... 22
3.7.2. Interrupt pin latching .......................................................................................................................................... 22
3.7.3. Monitoring .......................................................................................................................................................... 22
3.7.4. Interrupt Pin Configuration ................................................................................................................................ 22
3.7.5. Interrupt functions .............................................................................................................................................. 23
3.8. Current consumption ............................................................................................................................................. 26
3.9. Measurement timings ............................................................................................................................................. 26
3.9.1. Measurement time ............................................................................................................................................. 26
3.9.2. Measurement rate in forced mode and normal mode ....................................................................................... 27
3.10. Data readout from data registers ...................................................................................................................... 27
3.10.1. Data register shadowing.................................................................................................................................... 27
3.11. Output compensation ......................................................................................................................................... 28
3.11.1. Memory Map Trimming Coefficients .................................................................................................................. 28
4. Global memory map and register description ............................................................................................................ 29
4.1. General remarks ..................................................................................................................................................... 29
4.2. Datasheet Memory Map ......................................................................................................................................... 29
4.3. Register description ............................................................................................................................................... 31
4.3.1. Register 0x00 “CHIP_ID”................................................................................................................................... 31
4.3.2. Register 0x02 “ERR_REG” ............................................................................................................................... 31
4.3.3. Register 0x03 “STATUS” ................................................................................................................................... 31
4.3.4. Register 0x04 .. 0x06 Pressure Data ................................................................................................................ 32
4.3.5. Register 0x07 .. 0x09 Temperature Data .......................................................................................................... 32
4.3.6. Register 0x0C .. 0x0E Sensor Time .................................................................................................................. 33
4.3.7. Register 0x10 “EVENT” ..................................................................................................................................... 33
4.3.8. Register 0x11 “INT_STATUS”............................................................................................................................ 33
Page 5
4.3.9. Register 0x12 .. 0x13 “FIFO_LENGTH” ............................................................................................................ 33
4.3.10. Register 0x14 “FIFO_DATA” ............................................................................................................................. 34
4.3.11. Register 0x15 .. 0x16 FIFO Watermark ............................................................................................................. 34
4.3.12. Register 0x17 “FIFO_CONFIG_1”..................................................................................................................... 34
4.3.13. Register 0x18 “FIFO_CONFIG_2”..................................................................................................................... 35
4.3.14. Register 0x19 “INT_CTRL”................................................................................................................................ 35
4.3.15. Register 0x1A “IF_CONF” ................................................................................................................................. 36
4.3.16. Register 0x1B “PWR_CTRL”............................................................................................................................. 36
4.3.17. Register 0x1C “OSR” ........................................................................................................................................ 37
4.3.18. Register 0x1D “ODR” ........................................................................................................................................ 37
4.3.19. Control settings for odr_sel ............................................................................................................................... 38
4.3.20. Register 0x1F “CONFIG”................................................................................................................................... 39
4.3.21. Register 0x30 .. 0x57 “calibration data” ............................................................................................................ 39
4.3.22. Register 0x7E “CMD” ........................................................................................................................................ 39
5. Digital interfaces ............................................................................................................................................................ 40
5.1. Interface selection .................................................................................................................................................. 40
5.2. I²C Interface ............................................................................................................................................................. 40
5.2.1. I²C write ............................................................................................................................................................. 41
5.2.2. I²C read.............................................................................................................................................................. 41
5.3. SPI interface ............................................................................................................................................................ 42
5.3.1. SPI write ............................................................................................................................................................ 42
5.3.2. SPI read............................................................................................................................................................. 43
5.4. Interface parameter specification ......................................................................................................................... 43
5.4.1. General interface parameters............................................................................................................................ 43
5.4.2. I²C timings ......................................................................................................................................................... 43
5.4.3. SPI timings ........................................................................................................................................................ 45
6. Pin-out and connection diagram .................................................................................................................................. 46
6.1. Pin-out ..................................................................................................................................................................... 46
6.2. Connection diagram ¾-wire SPI............................................................................................................................ 47
6.3. Connection diagram I²C ......................................................................................................................................... 48
7. Package, reel and environment .................................................................................................................................... 49
7.1. Outline dimensions ................................................................................................................................................ 49
7.2. Landing pattern....................................................................................................................................................... 49
7.3. Marking .................................................................................................................................................................... 50
7.3.1. Mass production samples.................................................................................................................................. 50
7.3.2. Engineering samples ......................................................................................................................................... 50
7.4. Soldering guidelines .............................................................................................................................................. 51
7.5. Tape and reel specification .................................................................................................................................... 52
7.5.1. Dimensions ........................................................................................................................................................ 52
7.5.2. Orientation within the reel.................................................................................................................................. 52
7.6. Mounting and assembly recommendations ........................................................................................................ 52
7.7. Environmental safety ............................................................................................................................................. 53
7.7.1. RoHS ................................................................................................................................................................. 53
7.7.2. Halogen content ................................................................................................................................................ 53
7.7.3. Internal package structure ................................................................................................................................. 53
8. Legal disclaimer ............................................................................................................................................................. 54
8.1. Engineering samples ............................................................................................................................................. 54
8.2. Product use ............................................................................................................................................................. 54
8.3. Application examples and hints............................................................................................................................ 54
9. Appendix: Computation formulae reference implementation ................................................................................... 55
Page 6
9.1. Calibration coefficient ............................................................................................................................................ 55
9.2. Temperature compensation................................................................................................................................... 55
9.3. Pressure compensation ......................................................................................................................................... 56
10. Document history and modification ............................................................................................................................ 57
Page 7
1. Specification
If not stated otherwise,
• All values are valid over the full voltage range
• All minimum/maximum values are given for the full accuracy temperature range
• Minimum/maximum values of drifts, offsets and temperature coefficients are ±3σ values over lifetime
• Typical values of currents and state machine timings are determined at 25 °C
• Typical values of currents and state machine timings are determined at 25°C. minimum/maximum values of currents
are determined at -40°C/85°C.
• Minimum/maximum values of state machine timings are determined using corner lots over 0…+65 °C temperature
range.
Table 2: General electrical parameter specifications
OPERATING CONDITIONS BMP388
Parameter Symbol Condition Min Typ Max Unit
operational -40 25 +85
Operating
TA °C
temperature range
full accuracy 0 +65
Operating pressure
P full accuracy 300 1250 hPa
range
Sensor supply
VDD ripple max. 50mVpp 1.65 1.8 3.6 V
voltage
Interface supply
VDDIO 1.2 1.8 3.6 V
voltage
Sleep current IDD,sleep VDD = VDDIO 1.8-3.6 V 2 µA
during pressure
Peak current Ipeak 700 800 µA
measurement
Current at
temperature IDDT 300 400 µA
measurement
900 … 1100 hPa ±0.08 2 hPa
Relative accuracy
Arel
pressure 1 25 . . . 40 °C ±66 cm
700-1100 hPa
±0.75 Pa/K
Offset temperature 0 . . . 55 °C
TCO
coefficient 700-1100 hPa
±1.0 Pa/K
-20 . . .0 °C
300. . 1100 hPa
APfull -20 . . . 65 °C ±0.50 hPa
Absolute accuracy
pressure 900. . 1100 hPa
APext 25 . . . 40 °C ±0.40 hPa
1
Per 10 kPa steps
2
Mean value
Page 8
1100 . . 1250 hPa
AP -1.5 ±0.50 1.5 hPa
0 . . 65 °C
Resolution of
output data in
highest resolution RP Pressure 0.016 Pa
mode at lowest
bandwidth
Vp,full Full bandwidth, highest 1.2 Pa
resolution
See chapter 3.4.4
Noise in pressure
Vp,filtered Lowest bandwidth, highest 0.03 Pa
resolution
See chapter 3.4.4
AT @ 25 °C ±0.3 °C
Absolute accuracy
temperature 3 0 . . . +65 °C ±0.50 °C
Long term stability 4 ∆Pstab 12 months ±0.33 hPa
Minimum solder height 50 < ±1.0 hPa
Solder drifts µm
tstartup Time to first communication 2 ms
Start-up time after both VDD > 1.58V and
VDDIO > 0.65V
Possible sampling fsample osrs_t = osrs_p = 1; 200 Hz
rate See chapter 3.9
ODR accuracy ∆tstandby 25°C 2 +/- 12 5 %
3
Temperature measured by the internal temperature sensor. This temperature value depends on the PCB temperature, sensor element self-heating and
ambient temperature and is typically above ambient temperature.
4
Long term stability is specified in the full accuracy operating pressure range 0 … 65°C
5
From -40 to 85°C
Page 9
2. Absolute maximum ratings
The absolute maximum ratings are provided in Table 3 .
Table 3: Absolute maximum ratings
Parameter Symbol Condition Min Max Unit
Voltage at any supply pin VDD and VDDIO Pin -0.3 3.8 V
Voltage at any interface pin Vss -0.3 VDDIO + 0.3 V
Storage temperature ≤ 65% rel. H. -45 +85 °C
Overpressure survivability POVER 2 000 000 Pa
Mechanical shock MS MIL-STD-883H 12000 g
2002.5
Maximum allowable dust particle DustMAX ISO 12103-1 A2 300 6 µm
inside package
Class
Charge device model C2a:
(CDM) 500V to
ESD <750V
Human body model Class 2:
(HBM) 2 kV
Note: Stresses above these listed maximum ratings may cause permanent damage to the device. Exposure beyond specified
electrical characteristics (Table 2) may affect device reliability or cause malfunction.
3. Functional description
The BMP388 consists of a Piezo-resistive pressure sensing element and a mixed-signal ASIC. The ASIC performs A/D
conversions and provides the conversion results and sensor specific compensation data through a digital interface.
BMP388 provides highest flexibility to the designer and can be adapted to the requirements regarding accuracy,
measurement time and power consumption by selecting from a high number of possible combinations of the sensor settings.
BMP388 can be operated in three power modes (see section 3.3):
sleep mode | normal mode | forced mode
In sleep mode, no measurements are performed. Normal mode comprises an automated perpetual cycling between an active
measurement period and an inactive standby period. In forced mode, a single measurement is performed. When the
measurement is finished, the sensor returns to sleep mode.
6
Defined by hole size
Page 10
A set of oversampling settings is available ranging from ultra-low power to highest resolution setting in order to adapt the
sensor to the target application. The settings are predefined combinations of pressure measurement oversampling and
temperature measurement oversampling. Pressure and temperature measurement oversampling can be selected
independently from 0 to 32 times oversampling (see sections 3.4.1 and 3.4.2):
• Temperature measurement
• Ultra low power
• Low power
• Standard resolution
• High resolution
• Ultra high resolution
• Highest resolution
BMP388 is equipped with a built-in IIR filter in order to minimize short-term disturbances in the output data caused by the
slamming of a door or window. The filter coefficient ranges from 0 (off) to 127.
3.1. Block diagram
Figure 1 shows a simplified block diagram of the BMP388:
Figure 1: Block Diagram BMP388

Page 11
3.2. Power management
The BMP388 has two separate power supply pins
• VDD is the main power supply for all internal analog and digital regulator blocks.
• VDDIO is a separate power supply pin, used for the supply of the digital interface.
VDD and VDDIO pins can be energized in any order.
A power-on reset generator is built in which resets the logic circuitry and the register values after the power-on sequence.
The slope for ramp up time must not be less than 10 ms. After powering up, the sensor settles in sleep mode (see section
3.3).
Completion of the power-on-reset or soft reset is indicated by the bit por_detected[0]. The bit is cleared after reading.
Holding any interface pin (SDI, SDO, SCK or CSB) at a logical high level when VDDIO is switched off can permanently damage
the device due caused by excessive current flow through the ESD protection diodes.
Table 4: mode settings
Parameter Symbol Min. Max. Unit Test 7
VDDA power-on
Vpor_vdda 1.35 1.6 V T
rising edge
VDDA power-on
hysteresis
Vpor_hyst_vdda 75 mV T
VDDD power-on
Vpor_vddd 2.7 1.08 V Q
rising edge
VDDD power-on
Vpor_hyst_vddd 200 mV Q
hysteresis
3.3. Power modes
The BMP388 offers three power modes: sleep mode, forced mode and normal mode. These can be selected using the
mode[1:0] bits in control register “pwr_ctrl”.
Table 5: mode settings
mode[1:0] Mode
00 Sleep mode
01 and 10 Forced mode
11 Normal mode
3.3.1. Sleep mode
Sleep mode is set by default after power on reset. In sleep mode, no measurements are performed and power consumption
(IDDSL) is at a minimum. All registers are accessible; Chip-ID and compensation coefficients can be read.
3.3.2. Forced mode
In forced mode, a single measurement is performed according to selected measurement and filter options. When the
measurement is finished, the sensor returns to sleep mode and the measurement results can be obtained from the data
registers. For a next measurement, forced mode needs to be selected again. Forced mode is recommended for applications
which require low sampling rate or host-based synchronization.
7
T: directly or indirectly tested at 100% at room temperature, Q: tested at the initial qualification and if necessary
Page 12
current
osrs_p osrs_t
IMEAS, P
IMEAS, T
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement T
Measurement T
Measurement T
Measurement T
IIDLE
ISLEEP
Write time
POR settings Mode[1:0] = 01 Data readout Mode[1:0] = 01
Figure 2: Force mode timing diagram
3.3.3. Normal mode
Normal mode continuously cycles between an (active) measurement period and an (inactive) standby period. The
measurement rate is set in the odr_sel register (see 4.3.18), where various prescaler for sample frequencies fsampling=200Hz
can be selected. The sampling period 𝜏𝜏 calculated by
𝜏𝜏𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 = 𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝/𝑓𝑓𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 .
After setting the mode, measurement and filter options, the last measurement results can be obtained from the data registers
without the need of further write accesses. Normal mode is recommended when using the IIR filter, and useful for applications
in which short-term disturbances (e.g. blowing into the sensor) should be filtered.
τsampling
current
osrs_p osrs_t
IMEAS, P
IMEAS, T
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement T
Measurement T
Measurement T
Measurement T
IIDLE
ISLEEP
Write time
POR settings Mode[1:0] = 11 Data readout
when needed
Figure 3: Normal mode timing diagram

Page 13
3.3.4. Mode transition diagram
The supported mode transitions are displayed below. If the device is currently performing a measurement, execution of mode
switching commands is delayed until the end of the currently running measurement period. Further mode change commands
are ignored until the last mode change command is executed. Also, mode change commands that are not legal are ignored.
Power OFF
(VDDA or VDDD = 0)
Normal
(cyclic standby and
VDDA and V DDD measurement periods)
supplied
Sleep
Forced
(one measurement
period)
Figure 4: Mode transition diagram
3.4. Measurement flow
The BMP388 measurement period consists of a temperature and pressure measurement with selectable oversampling. After
the measurement period, the data are passed through an optional IIR filter, which removes short-term fluctuations in pressure
(e.g. caused by slamming a door). The flow is depicted in the diagram below.
Start
measurement cycle
Measure pressure
(oversampling set by osrs_p; IIR filter enabled? No
skip if press_en = 0)
Yes
Measure temperature Copy ADC values
(oversampling set by osrs_t; IIR filter initialised? No to filter memory
skip if temp_en = 0) (initalises IIR filter)
Yes
Update filter memory using Copy filter memory
filter memory, ADC value to output registers,
and filter coefficient send filter memory to FIFO
End
measurement cycle
Figure 5: BMP388 measurement cycle
The individual blocks of the diagram above will be detailed in the following subsections.

Page 14
3.4.1. Pressure measurement
Pressure measurement can be enabled or skipped. Skipping the measurement could be useful if BMP388 is used as
temperature sensor. When enabled, several oversampling options exist. Each oversampling step reduces noise and
increases the output resolution by one bit, which is stored in the XLSB data register.
Enabling the measurement is selected by press_en bit in “PW_CTRL[0]” register (see 4.3.16). The oversampling setting
osr_p can be configured in “OSR[2:0]” register (see 4.3.17).
Table 6: osr_p settings 8
Recommended
Pressure Typical pressure
Oversampling setting osr_p temperature
oversampling resolution
oversampling
Ultra low power 000 ×1 16 bit / 2.64 Pa ×1
Low power 001 ×2 17 bit / 1.32 Pa ×1
Standard resolution 010 ×4 18 bit / 0.66 Pa ×1
High resolution 011 ×8 19 bit / 0.33 Pa ×1
Ultra high resolution 100 ×16 20 bit / 0.17 Pa ×2
Highest resolution 101 ×32 21 bit / 0.085 Pa ×2
3.4.2. Temperature measurement
Temperature measurement can be enabled or skipped. Skipping the measurement could be useful to measure pressure
extremely rapidly. When enabled, several oversampling options exist. Each oversampling step reduces noise and increases
the output resolution by one bit, which is stored in the XLSB data register. Noise and increases the output resolution by one
bit, which is stored in the XLSB data register.
Enabling the measurement is selected by temp_en bit in “PW_CTRL[1]” register (see 4.3.16). The oversampling setting osr_t
can be configured in “OSR[5:3]” register (see 4.3.17).
Table 7: osrs_t settings
Temperature Typical temperature
osr_t
oversampling resolution
000 ×1 16 bit / 0.0050 °C
001 ×2 17 bit / 0.0025 °C
010 ×4 18 bit / 0.0012 °C
011 ×8 19 bit / 0.0006 °C
100 ×16 20 bit / 0.0003 °C
101 ×32 21 bit / 0.00015 °C
It is recommended to base the value of osr_t on the selected value of osrs_p as per Table 5. Temperature oversampling
above ×2 is possible, but will not significantly improve the accuracy of the pressure output any further. The reason for this is
that the noise of the compensated pressure value depends more on the raw pressure than on the raw temperature noise.
Following the recommended setting will result in an optimal noise-to-power ratio.
8
Resolution of 24 bit e.g. OSR=32x and IIR>=b011
Page 15
3.4.3. IIR filter
The environmental pressure is subject to many short-term changes, caused e.g. by slamming of a door or window, or wind
blowing into the sensor. To suppress these disturbances in the output data without causing additional interface traffic and
processor work load, the BMP388 features an internal IIR filter. It effectively reduces the bandwidth of the output signals 9.
The output of a next measurement step is filter using the following formula:
𝑑𝑑𝑑𝑑𝑑𝑑𝑎𝑎𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓_𝑜𝑜𝑜𝑜𝑜𝑜 ∗ 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓_𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 + 𝑑𝑑𝑑𝑑𝑑𝑑𝑎𝑎𝐴𝐴𝐴𝐴𝐴𝐴
𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓 =
𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓_𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑡𝑡 + 1
where data_filtered_old is the data coming from the previous acquisition, and data_ADC is the data coming from the ADC
before IIR filtering.
The IIR filter can be configured using setting iir_filter in “CONFIG” register (see 4.3.20).
When writing to the register filter, the filter is reset. The next value will pass through the filter and be the initial memory value
for the filter. IIR filter is reset if the temperature or pressure measurement is disabled (temp_en or press_en registers changed
from ‘1’ to ‘0’) or when a transition from sleep mode to normal mode occurs. After enabling of pressure or temperature
measurement, the filtering will start, thus the next incoming value will pass unfiltered and be the initial value of the IIR filter.
The step response (e.g. response to in sudden change in height) of different filter settings is displayed in Figure 6.
Figure 6: Step response at different IIR filter settings
3.4.4. Oversampling
Noise depends on the oversampling and filter settings selected. The stated values were determined in a controlled pressure
environment and are based on the average standard deviation of 32 consecutive measurement points taken at highest
sampling rate (for details please refer to Table 21). This is required to exclude long term drifts from the noise measurement.
9
Since most pressure sensors do not sample continuously, filtering can suffer from signals with a frequency higher than the sampling rate of the sensor.
E.g. environmental fluctuations caused by windows being opened and closed might have a frequency <5 Hz. Consequently, a sampling rate of ODR = 10
Hz is sufficient to obey the Nyquist theorem.

Page 16
Table 8: Noise in pressure
Typical RMS noise in pressure [Pa]
Oversampling IIR filter coefficient
setting off 1 3 7 15 31 63 127
Ultra low power 6.6 3.8 2.5 1.7 1.2 0.8 0.6 0.4
Low power 4.3 2.5 1.6 1.1 0.8 0.5 0.4 0.3
Standard resolution 3.2 1.8 1.2 0.8 0.6 0.4 0.3 0.2
High resolution 2.3 1.3 0.9 0.6 0.4 0.3 0.2 0.1
Ultra high resolution 1.6 0.9 0.6 0.4 0.2 0.2 0.1 0.1
Highest resolution 1.2 0.7 0.4 0.3 0.3 0.1 0.1 <0.1
Table 9: Noise in temperature
Typical RMS noise in temperature [°C]
Temperature oversampling IIR filter off
Ultra low power 0.005
Low power 0.005
Standard resolution 0.005
High resolution 0.005
Ultra high resolution 0.004
Highest resolution 0.003
Page 17
3.5. Filter selection
In order to select optimal settings, the following use cases are suggested:
Table 10: Recommended filter settings based on use cases
IIR filter
Over- RMS Noise
coeff. IDD [µA] ODR [Hz]
Use case Mode sampling osrs_p osrs_t [cm]
setting (see (see 3.8) (see 3.4.1)
(see 3.4.4)
4.3.20)
handheld
device low-
High
power Normal x8 ×1 2 145 12.5 11
resolution
(e.g.
Android)
handheld
device
Standard
dynamic Normal ×4 ×1 4 310 50 10
resolution
(e.g.
Android)
Weather
monitoring Ultra low
Forced ×1 ×1 Off 4 1/60 55
(lowest power
power),
Drop
Normal Low power ×2 ×1 Off 358 100 36
detection
Indoor Ultra high
Normal ×16 ×2 4 560 25 5
navigation resolution
Standard
Drone Normal x8 x1 2 570 50 11
Resolution
Page 18
3.6. FIFO Description
The BMP388 contains a 512 Bytes FIFO (first-in-first-out) data buffer. To enable data collecting in the FIFO, fifo_mode is set
at ‘1’ and data to be collected are defined through fifo_press_en and fifo_temp_en. The FIFO mode is disabled, when no
writing is defined which according to the following two cases:
• fifo_mode=’0’
• fifo_mode=’1’ and fifo_press_en=’0’ and fifo_temp_en=’0’
If the FIFO is disabled when FIFO byte count is greater than 0, no new frame is written to the FIFO, but FIFO is operational:
• Frames already written in the FIFO remain stored and can be read out
• FIFO interrupts and their corresponding statuses are still evaluated
• after all bytes are read out, Sensortime (if enabled) and Empty frames are generated
• FIFO can be flushed
3.6.1. FIFO input data
Storing of pressure and/or temperature measurement results is enabled by setting fifo_press_en=’1’ and fifo_temp_en=’1’
respectively. Storing of data can be enabled or disabled on a per-channel basis in any combination. Filtered or unfiltered data
are stored to the FIFO; if data_select=”01”, filtered data are stored, otherwise unfiltered data are stored to the FIFO. The
Number of bytes available in FIFO is readable through fifo_length_1<0> (MSBs) and fifo_length_0<7:0> (LSBs) registers.
The FIFO byte count registers fifo_length_0 and fifo_length_1 are updated only when a full frame has been written to FIFO
and is available for read-out. FIFO byte count registers are also updated after each full-frame read from the FIFO.
FIFO byte count registers increment or decrement is equal to frame length; intermediate increments (corresponding to a
partial frame) are not readable.
3.6.2. FIFO data sampling selection
The FIFO input data rate is reduced by selecting a down-sampling factor in register fifo_subsampling. Down-sampling factor
ranges from 1 to 128 and is equal to 2fifo_subsampling. Down-sampling is applied in the normal mode only and is aligned to the
measurement timing grid. Down-sampling counter is reset and data saved to the FIFO at the end of the first measurement
when a transition from sleep mode to normal mode occurs.
3.6.3. FIFO read out
FIFO is read out via fifo_data register. FIFO reads are never blocked, however an ongoing read from the FIFO does not block
writing to the FIFO.
During burst read, the address counter stops incrementing when fifo_data address is reached; this allows a complete reading
of the FIFO content within one burst read transaction.
Page 19
3.6.4. FIFO overflow behavior
A FIFO overflow occurs if the FIFO is full and a new data is written to the FIFO. FIFO full means free space is less than
maximum frame length (9 bytes). In case of overflow the FIFO can either stop recording data or overwrite the oldest data.
The behavior is controlled by register fifo_stop_on_full.
• Streaming mode, fifo_stop_on_full=’0’:
if the new frame does not fit inside the remaining free space in the FIFO RAM, FIFO will repeatedly delete the
oldest frame until it creates enough space for the new one.
• FIFO stop-on-full mode, fifo_stop_on_full=’1’:
The newest frame is discarded. Normal operation resumes if the FIFO full condition no longer persists.
3.6.5. FIFO Frames
One data frame is composed of a header and a set of data organize as described in table below.
Table 11: Data frame composition
Bit 7 6 5 4 3 2 1 0
Header fh_mode[1:0] fh_param[3:0] 0 0
Data Data bytes
The number of data bytes is defined by the header.
3.6.5.1. Header Format
Table 12: Header format
fh_mode[1:0] Definition fh_param[3:0]
10 Sensor frame Sensor enable bits
Control frame: configuration
01 0001
error
Control frame: FIFO input
01 0010
configuration change
3.6.5.2. Sensor Frame Format
A sensor frame consists of a header and data bytes
Table 13: Sensor frame format
Bit 7 6 5 4 3 2 1 0
Header 1 0 s t 0 p 0 0
Data data bytes
Sensor data in frame is defined by s (time), t (temperature) and p (pressure) sensor enable bits:
• If s=’1’, the frame corresponds to the sensor-time frame, in that case, t=p=’0’
• If t=’1’ or/and p=’1’, the frame corresponds to a normal pressure or/and a temperature frame
• If s=t=p=’0’, the frame corresponds to an empty frame
Page 20
Table 14: Sensor-time frame
Bit 7 6 5 4 3 2 1 0
Header 1 0 1 0 0 0 0 0
time_xlsb[7:0]
Sensor-
time_lsb[7:0]
time
time_msb[7:0]
The data for the sensor-time frame consists of register sensor_time content at the time the sensortime frame transmission
has started. A sensor-time frame is not stored in the FIFO, but append to every FIFO burst read operation after all data has
been transmitted if fifo_time_en=‘1’.
Table 15: Normal pressure and temperature frame
Bit 7 6 5 4 3 2 1 0
Header 1 0 0 1 0 1 0 0
Temp temp_xlsb[7:0]
temp_lsb[7:0]
temp_msb[7:0]
Press press_xlsb[7:0]
press_lsb[7:0]
press_msb[7:0]
If one of t and p is ‘0’, the corresponding data is not part of the frame; the frame is therefore reduced to 4 bytes.
A FIFO empty frame is a sensor frame with no sensor enabled. This frame is returned if the last frames was read-out or if
FIFO is empty.
Table 16: FIFO empty frame format
Bit 7 6 5 4 3 2 1 0
Header 1 0 0 0 0 0 0 0
Data 0 0 0 0 0 0 0 0
When a configuration error is detected, a configuration error frame is stored into the FIFO
Table 17: Control frame: configuration error
Bit 7 6 5 4 3 2 1 0
Header 0 1 0 0 0 1 0 0
Opcode 0 0 0 0 0 0 0 1
If FIFO is enabled and a change in registers “FIFO_CONF_2” or “OSR” or “ODR” or “CONFIG” or press_en or temp_en
occurs, a control frame is inserted just before the first sensor frame with new configuration is stored to the FIFO. If multiple
configuration change becomes active at the same time, only one control frame is inserted. Configuration changes are tracked
when the device is in normal mode.
Page 21
3.6.6. Corner cases
3.6.6.1. Under-read
In case the FIFO is under-read (not all frames were taken from the FIFO, but the last frame read was read entirely), the next
readout will continue at the frame that was just about to be sent.
3.6.6.2. Partial frame read
In case the FIFO is under-read and a partial data frame read occurred (not all frames were taken from the FIFO, and the last
frame read was not read entirely), the entire last data frame is repeated upon the next read access.
When fifo_stop_on_full=’0’, the oldest frames are overwritten when new frames are available and the FIFO is full. When this
happens, the partially read data frame is not repeated but the oldest frame available in the RAM is sent instead.
Sensortime frame is not repeated when read only partially, its payload always contains current sensortime counter value.
If the read of the frame is interrupted after two or more bits of the frame’s last byte were already read, then frame is discarded
even though not all bits were read and the frame was read only partially.
3.6.6.3. Over-read
If the burst read continues after all frames have been read out, a sensortime frame is sent after the FIFO becomes empty
during a burst read operation if fifo_time_en=’1’. After that or when FIFO was completely read, the empty frame is returned
as long as the burst read is
active.
3.6.7. FIFO flush conditions
The FIFO can be flushed by issuing either fifo_flush or a softreset in the command register “CMD” (see 4.3.22):
Table 18: fifo_fluch and softreset commands
Value
fifo_flush 0xB0
softreset 0xB6
Page 22
3.7. Interrupts
The BMP388 provides an interrupt pin (INT), which allows to signal certain events to the host processor. Different events can
be mapped to the interrupt pin, which all are processed with a logical OR.
The available interrupts are listed below and can be read in the “INT_STATUS” register (see 4.3.8):
• FIFO watermark interrupt
• FIFO full interrupt
• Data ready interrupt
3.7.1. Interrupt default mode
After a power-on or soft reset has completed, the interrupt pin is in push-pull and active high mode.
3.7.2. Interrupt pin latching
The chip can be operated in non-latched or latched mode:
• Non-latched mode: Interrupts’ conditions are selected as a contributors to the INT pad. INT pad is de-asserted as
soon as the conditions of all the interrupts propagated to the INT pad are not valid.
For data ready, interrupt contribution is de-asserted by reading int_status or after 2.5ms after assertion of the
interrupt.
For FIFO interrupts, INT pad contributions are not affected by fifo_data readings, only by the interrupt conditions
• Latched mode: Interrupt statuses are selected as contributors of the INT pad.
The minimum interrupt pulse width is Tint = 1µs
3.7.3. Monitoring
The status of interrupt bits is always visible in the “INT_STATUS” register. (see 4.3.8) for details.
3.7.4. Interrupt Pin Configuration
The interrupt pin / pad is configured by the Bits in the “INT_CTRL” register (see 4.3.14). However, the status bits are not
influenced thereby.
The output mode of the INT pad is controlled by int_od bit:
Table 19: int_od
int_od=’0’ Push-pull
int_od=’1’ Open-drain
The level of the interrupt pad can be configured and switched by int_level between active low and active high:
Table 20: int_level
int_level=’0’ active_low
int_level=’1’ active_high
The latching of interrupts for INT pad and INT_STATUS register can be enabled by int_latch=’1’ or disabled by int_latch=’0’.
Page 23
FIFO interrupts are mapped to the INT pad by enabling the respective functions. For mapping FIFO watermark reached
interrupt to the pad, the fwtm_en bit shall be written to ’1’ (disabling by ‘0’). The FIFO full interrupt can be mapped by writing
ffull_en with ‘1’).
3.7.5. Interrupt functions
3.7.5.1. FIFO watermark interrupt
The FIFO watermark interrupt is used to signal, that fill level of the FIFO has reached a pre-set limit.
Fifo_length_1 & fifo_length_0 ≥ fifo_wtm_1 & fifo_wtm_0
The watermark level can be set and adjusted by the user by writing the registers and 0x15 “FIFO_WTM_0” and 0x16
“FIFO_WTM_1” (see 4.3.11) in a single burst transaction. If the FIFO watermark level is set to zero, the interrupt condition
will never be satisfied.
The status of the watermark interrupt can be read back through the fwm_int bit. The interrupt condition is also updated after
the end of a serial interface transaction which wrote into the registers fifo_wtm_0 or fifo_wtm_1.
Figure 7: FIFO watermark interrupt, non-latched with reads from FIFO
Figure 8: FIFO watermark interrupt, latched, with reads from FIFO

Page 24
3.7.5.2. FIFO full interrupt
FIFO Full interrupt status is asserted when the full interrupt condition is satisfied, when the filling level of the FIFO
number of unread bytes in the FIFO = fifo_length_1 & fifo_length_0 is equal or higher than 504.
The status of the FIFO full interrupt can be read back through the ffull_int bit. Interrupt status is cleared by reading the ffull_int
bit high ‘1’ when the FIFO filling level is lower than 504.
The FIFO full interrupt is propagated to INT pad only when it is enabled by setting bit ffull_en=‘1’. Latching mode configuration
bit int_latch selects whether the interrupt status or condition is propagated to the INT pad.
Figure 9:FIFO full interrupt, non-latched, with reads from FIFO
Figure 10: FIFO full interrupt, latched, with reads from FIFO
3.7.5.3. Data ready
Data ready interrupt status int_status.drdy is asserted after a pressure and temperature measurement ends and conversion
results are stored to the data registers and to the FIFO. The status of the interrupt can be read back through the drdy bit.
The data ready interrupt is propagated to INT pad when it is enabled by setting drdy_en=‘1’. Interrupt status is cleared by
reading drdy bit high ‘1’. Data ready INT pad contribution is cleared automatically 2.5 ms after the interrupt assertion in the
non-latched mode (int_latch=’0’).
Corner cases:
• If data ready interrupt is changed from latched to non-latched mode (int_latched changed from ‘1’ to ‘0’) after the
interrupt was already asserted;
timer is not running and it is not starting during the ongoing measurement, self-clearing does not happen. Timer is
starting when next data ready comes.
• If data ready is changed to be propagated to INT pad (drdy_int changed from ‘0’ to ‘1’) after the interrupt was
already asserted;
data ready INT pad contribution remains ‘0’ until next data ready interrupt assertion.

Page 25
Figure 11: Data ready interrupt, non-latched mode, with read of data registers
Figure 12: Data ready interrupt, non-latched mode, with read of data registers during register update
Figure 13: Data ready interrupt, latched mode, with read of data registers

Page 26
3.8. Current consumption
The current consumption depends on ODR and oversampling setting. The values given below are normalized to an ODR of
1 Hz. The actual consumption at a given ODR can be calculated by multiplying the consumption in Table 20 with the ODR
used. The actual ODR is defined either by the frequency at which the user sets forced measurements or by oversampling
and sampling period settings in normal mode in Table 23.
Table 21: Current consumption
Oversampling setting Pressure Temperature IDD [µA] @ 1 Hz forced
oversampling oversampling mode
Typ Calculated Max
Forced
Mode
Ultra low power ×1 ×1 3.4 4.3 7.4
Low power ×2 ×1 4.8 5.6 9.3
Standard resolution ×4 ×1 7.8 8.2 12.8
High resolution ×8 ×1 13.8 13.3 19.5
Ultra high resolution ×16 ×2 26.2 24.3 33.5
highest resolution ×32 ×2 46.4 45.0 59.2
3.9. Measurement timings
The rate at which measurements can be performed in forced mode depends on the oversampling settings osr_t and osr_p.
Thus in normal mode, the measurement rate is determined by the sampling frequency fsample.
3.9.1. Measurement time
The following table explains the typical and maximum measurement time based on selected oversampling setting. The
minimum achievable frequency is determined by the maximum measurement time.
Table 22: measurement time
Oversampling Pressure Temperature Measurement Measurement rate
setting oversampling oversampling time[ms] [Hz]
Typ Max Typ Min
Ultra low power ×1 ×1 4.82 5.70 207.08 175.39
Low power ×2 ×1 6.84 7.96 146.00 125.56
Standard resolution ×4 ×1 10.88 12.48 91.83 80.07
High resolution ×8 ×1 18.69 21.53 52.71 46.42
Ultra high resolution ×16 ×2 37.14 41.89 26.91 23.86
highest resolution ×32 ×2 69.46 78.09 14.39 12.80
Page 27
3.9.2. Measurement rate in forced mode and normal mode
In both forced mode and normal mode the pressure and temperature measurement duration follow the equation:
𝑇𝑇𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 = 234µ𝑠𝑠 + 𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝_𝑒𝑒𝑒𝑒 ∙ (392µ𝑠𝑠 + 2𝑜𝑜𝑜𝑜𝑜𝑜_𝑝𝑝 ∙ 2000µ𝑠𝑠) + 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡_𝑒𝑒𝑒𝑒 ∙ (313µ𝑠𝑠 + 2𝑜𝑜𝑜𝑜𝑜𝑜_𝑡𝑡 ∙ 2000µ𝑠𝑠)
With:
𝑇𝑇𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 = total conversion time in µs
𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝_𝑒𝑒𝑒𝑒 = “0” or “1”, depending of the status of the press_en bit
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡_𝑒𝑒𝑒𝑒 = “0” or “1”, depending of the status of the temp_en bit
2𝑜𝑜𝑜𝑜𝑜𝑜_𝑝𝑝 = amount of pressure oversampling repetitions
2𝑜𝑜𝑜𝑜𝑜𝑜_𝑡𝑡 = amount of temperature oversampling repetitions
Maximum possible readout frequency in forced mode (typical):
1
𝑓𝑓𝑚𝑚𝑚𝑚𝑚𝑚 =
𝑇𝑇𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 [µ𝑠𝑠] ∙ 106
Maximum possible readout frequency in normal mode:
200𝐻𝐻𝐻𝐻
𝑜𝑜𝑜𝑜𝑜𝑜_𝑠𝑠𝑠𝑠𝑠𝑠 = �𝑙𝑙𝑙𝑙𝑔𝑔2 � ��
𝑓𝑓𝑚𝑚𝑚𝑚𝑚𝑚 [𝐻𝐻𝐻𝐻]
200𝐻𝐻𝐻𝐻
𝑓𝑓𝑚𝑚𝑚𝑚𝑚𝑚_𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛_𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 =
2𝑜𝑜𝑜𝑜𝑜𝑜_𝑠𝑠𝑠𝑠𝑠𝑠
3.10. Data readout from data registers
To read out data after a conversion, it is strongly recommended to use a burst read and not address every register individually.
This will prevent a possible mix-up of bytes belonging to different measurements and reduce interface traffic. Data readout
is done by starting a burst read from register press_xlsb to temp_msb. The data are read out in an unsigned 24-bit format
both for pressure and for temperature.
The timing for data readout in forced mode should be done so that the maximum measurement times (see Sec. 3.9.1) are
respected. In normal mode, readout can be done at a speed similar to the expected data output rate (see Sec. 3.9.2). After
the uncompensated values of temperature and pressure have been read, the actual pressure and temperature need to be
calculated using the compensation parameters stored in the device. The procedure is elaborated in Sec. 3.11.
3.10.1. Data register shadowing
In normal mode, measurement timing is not necessarily synchronized to readout. This means that new measurement results
may become available while the user is reading the results from the previous measurement. In this case, shadowing is
performed in order to guarantee data consistency. Shadowing will only work if all data registers are read in a single burst
read. Therefore, the user must use burst reads if he does not synchronize data readout with the measurement cycle. Using
several independent read commands may result in inconsistent data.
If a new measurement is finished and the data registers are still being read, the new measurement results are transferred
into shadow data registers. The content of shadow registers is transferred into data registers as soon as the user ends the
burst read, even if not all data registers were read. Reading across several data registers can therefore only be guaranteed
to be consistent within one measurement cycle if a single burst read command is used. The end of the burst read is marked
by the rising edge of CSB pin. After the end of the burst read, all user data registers are updated at once.
Page 28
3.11. Output compensation
The BMP388 output consists of the ADC output values (including oversampling). However, each sensing element behaves
differently, and thus in order to receive the most accurate physical values for temperature and pressure, compensation
formulae have to be applied to the raw output values received from the sensor. The coefficients used for the compensation
are stored into the devices’ non-volatile memory (NVM) during production (see Table 22). For the compensation formula
please see Appendix 9.
3.11.1. Memory Map Trimming Coefficients
Table 23: Trimming Coefficient listing in register map with size and sign attributes
Memory- Memory-
Trimming
ADR_Read ADR_Read Register content Size Sign
Coefficient
[dec] [hex]
69 0x45 NVM_PAR_P11<7:0> NVM_PAR_P11 8 Bit signed
68 0x44 NVM_PAR_P10<7:0> NVM_PAR_P10 8 Bit signed
67 0x43 NVM_PAR_P9<15:8>
16
NVM_PAR_P9 signed
Bit
66 0x42 NVM_PAR_P9<7:0>
65 0x41 NVM_PAR_P8<7:0> NVM_PAR_P8 8 Bit signed
64 0x40 NVM_PAR_P7<7:0> NVM_PAR_P7 8 Bit signed
63 0x3F NVM_PAR _P6<15:8>
16
NVM_PAR _P6 unsigned
Bit
62 0x3E NVM_PAR _P6<7:0>
61 0x3D NVM_PAR _P5<15:8>
16
NVM_PAR _P5 unsigned
Bit
60 0x3C NVM_PAR _P5<7:0>
59 0x3B NVM_PAR _P4<7:0> NVM_PAR _P4 8 Bit signed
58 0x3A NVM_PAR _P3<7:0> NVM_PAR _P3 8 Bit signed
57 0x39 NVM_PAR _P2<15:8>
16
NVM_PAR _P2 signed
Bit
56 0x38 NVM_PAR _P2<7:0>
55 0x37 NVM_PAR _P1<15:8>
16
NVM_PAR _P1 signed
Bit
54 0x36 NVM_PAR _P1<7:0>
53 0x35 NVM_PAR _T3<7:0> NVM_PAR _T3 8 Bit signed
52 0x34 NVM_PAR _T2<15:8>
16
NVM_PAR _T2 unsigned
Bit
51 0x33 NVM_PAR _T2<7:0>
50 0x32 NVM_PAR _T1<15:8>
16
NVM_PAR _T1 unsigned
Bit
49 0x31 NVM_PAR _T1<7:0>
Page 29
4. Global memory map and register description
4.1. General remarks
All communication with the device is performed by reading and writing registers. All Registers have a width of 8 bits. There
are several registers which are reserved; they should not be written to and no specific value is guaranteed when they are
read. For details on the interface, consult chapter 5.
4.2. Datasheet Memory Map
The memory map is given in Table 23.
Page 30
Table 24: BMP388 memory map
read/write read only write only reserved
read/write read only write only reserved
Registe
r Registe Default
7 6 5 4 3 2 1 0
Addres r Name Value
s
0x7E CMD 0x00 cmd
0x7D - - reserved
... - - reserved
0x20 - - reserved
CONFI reserve
0x1F 0x00 reserved iir_filter
G d
0x1E - - reserved
0x1D ODR 0x00 reserved odr_sel
0x1C OSR 0x02 reserved osr_t osr_p
PWR_C temp_e press_e
0x1B 0x00 reserved mode reserved
TRL n n
IF_CON i2c_wdt i2c_wdt
0x1A 0x00 reserved spi3
F _sel _en
INT_CT reserve reserve
0x19 0x02 drdy_en ffull_en fwtm_en int_latch int_level int_od
RL d d
FIFO_C
0x18 ONFIG_ 0x02 reserved data_select fifo_subsampling
2
FIFO_C
fifo_tem fifo_pre fifo_time fifo_stop fifo_mo
0x17 ONFIG_ 0x02 reserved
p_en ss_en _en _on_full de
1
fifo_wat
FIFO_W
0x16 0x00 reserved er_mark
TM_1
_8
FIFO_W
0x15 0x01 fifo_water_mark_7_0
TM_0
FIFO_D
0x14 0x00 fifo_data
ATA
FIFO_L fifo_byte
0x13 ENGTH 0x00 reserved _counte
_1 r_8
FIFO_L
0x12 ENGTH 0x00 fifo_byte_counter_7_0
_0
INT_ST reserve
0x11 0x00 reserved drdy ffull_int fwm_int
ATUS d
por_det
0x10 EVENT 0x01 reserved
ected
SENSO
0x0E RTIME_ 0x00 sensor_time_23_16
2
SENSO
0x0D RTIME_ 0x00 sensor_time_15_8
1
Page 31
SENSO
0x0C RTIME_ 0x00 sensor_time_7_0
0
0x0B - - reserved
0x0A - - reserved
0x09 DATA_5 0x80 temp_23_16
0x08 DATA_4 0x00 temp_15_8
0x07 DATA_3 0x00 temp_7_0
0x06 DATA_2 0x80 press_23_16
0x05 DATA_1 0x00 press_15_8
0x04 DATA_0 0x00 press_7_0
reserve drdy_te drdy_pr cmd_rd
0x03 STATUS 0x00 reserved
d mp ess y
ERR_R
0x02 0x00 reserved conf_err cmd_err fatal_err
EG
0x01 - - reserved
CHIP_I
0x00 0x50 chip_id_fixed chip_id_nvm
D
4.3. Register description
4.3.1. Register 0x00 “CHIP_ID”
The “CHIP_ID” register contains the chip identification code.
Table 25: Register 0x00 “CHIP_ID”
Name Description
Bit 7..0 Chip id.
4.3.2. Register 0x02 “ERR_REG”
Sensor Error conditions are reported in the “ERR_REG” register.
Table 26: Register 0x02 “ERR_REG”
Name Description
Bit 0 fatal_err Fatal error
Bit 1 cmd_err Command execution failed. Cleared on read.
Bit 2 conf_err sensor configuration error detected. Cleared on read.
4.3.3. Register 0x03 “STATUS”
The Sensor Status Flags are stored in the “STATUS” register.
Page 32
Table 27: Register 0x03 “STATUS”
Name Description
CMD decoder status.
Bit 4 cmd_rdy 0: Command in progress
1: Command decoder is ready to accept a new command
Data ready for pressure.
Bit 5 drdy_press
It gets reset, when one pressure DATA register is read out
Data ready for temperature sensor.
Bit 6 drdy_temp
It gets reset, when one temperature DATA register is read out
4.3.4. Register 0x04 .. 0x06 Pressure Data
The 24Bit pressure data is split and stored in three consecutive registers
• 0x04 “DATA_0”
• 0x05 “DATA_1”
• 0x06 “DATA_2”
Table 28: Pressure Data Registers
Register 0x06 DATA_2 0x05 DATA_1 0x04 DATA_0
Bit 7..0 7..0 7..0
name PRESS_MSB_23_16 PRESS_LSB_15_8 PRESS_XLSB_7_0
Data pressure data
4.3.5. Register 0x07 .. 0x09 Temperature Data
The 24Bit temperature data is split and stored in three consecutive registers
• 0x07 “DATA_3”
• 0x08 “DATA_4”
• 0x09 “DATA_5”
Table 29: Temperature Data Registers
Register 0x09 DATA_5 0x08 DATA_4 0x07 DATA_3
Bit 7..0 7..0 7..0
name TEMP_MSB_23_16 TEMP_LSB_15_8 TEMP_XLSB_7_0
Data temperature data
Page 33
4.3.6. Register 0x0C .. 0x0E Sensor Time
The 24Bit sensor time is split and stored in three consecutive registers
• 0x0C “SENSORTIME_0”
• 0x0D “SENSORTIME_1”
• 0x0E “SENSORTIME_2”
Table 30: Sensor Time Registers
Register 0x0E SENSORTIME_2 0x0D SENSORTIME_1 0x0C SENSORTIME_0
Bit 7..0 7..0 7..0
name sensor_time_23_16 sensor_time_15_8 sensor_time_7_0
Data Sensor time
4.3.7. Register 0x10 “EVENT”
The “EVENT” register contains the sensor status flags.
Table 31: Register 0x10 “EVENT”
Name Description
Bit 0 por_detected ‘1’ after device power up or softreset. Clear-on-read
4.3.8. Register 0x11 “INT_STATUS”
The “INT_STATUS” register shows interrupt status and is cleared after reading.
Table 32: Register 0x11 “INT_STATUS”
Name Description
Bit 0 fwm_int FIFO Watermark Interrupt
Bit 1 ffull_int FIFO Full Interrupt
Bit 3 drdy data ready interrupt
4.3.9. Register 0x12 .. 0x13 “FIFO_LENGTH”
The FIFO byte counter indicates the current fill level of the FIFO buffer. Its size is 9 bit for 512 bytes and therefore split in two
registers “FIFO_LENGTH_0” and “FIFO_LENGTH_1”.
Table 33: FIFO Length Split
Register 0x13 FIFO_LENGTH_1 0x12 FIFO_LENGTH_0
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
name fifo_byte_counter_8 fifo_byte_counter_7_0
Page 34
4.3.10. Register 0x14 “FIFO_DATA”
The “FIFO_DATA” is the data output register.
Table 34: Register 0x14 “FIFO_DATA”
Name Description
Bit 7..0 fifo_data FIFO read data.
4.3.11. Register 0x15 .. 0x16 FIFO Watermark
The FIFO Watermark size is 9 Bit and therefore written to the FIFO_WTM_0 and FIFO_WTM_1 registers.
Table 35: FIFO Watermark Register Overview
Register 0x16 FIFO_WTM_1 0x15 FIFO_WTM_0
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
name fifo_water_mark_8 fifo_water_mark_7_0
4.3.12. Register 0x17 “FIFO_CONFIG_1”
The “FIFO_CONFIG_1” register contains the FIFO frame content configuration.
Table 36: Register 0x17 “FIFO_CONFIG_1”
Name Description
Bit 0 fifo_mode Enables or disables the FIFO
0 disable
1 enable FIFO mode
Bit 1 fifo_stop_on_full Stop writing samples into FIFO when FIFO is full.
0 disable do not stop writing to FIFO when full
1 enable Stop writing into FIFO when full.
Bit 2 fifo_time_en Return sensortime frame after the last valid data frame.
0 disable do not return sensortime frame
1 enable return sensortime frame
Bit 3 fifo_press_en Store pressure data in FIFO
0 disable no pressure data is stored
1 enable pressure data is stored
Bit 4 fifo_temp_en Store temperature data in FIFO
0 disable no temperature data is stored
1 enable temperature data is stored
Page 35
4.3.13. Register 0x18 “FIFO_CONFIG_2”
The “FIFO_CONFIG_2” register extends the FIFO_CONFIG_1 register.
Table 37: Register 0x18 “FIFO_CONFIG_2”
Name Description
FIFO downsampling selection for pressure and temperature data, factor is
Bit 2..0 fifo_subsampling 2^fifo_subsampling
for pressure and temperature, select data source
0 unfiltered data (compensated or uncompensated)
Bit 4..3 data_select 1 filtered data (compensated or uncompensated)
11/10 reserved, same as for “unfilt”
4.3.14. Register 0x19 “INT_CTRL”
Interrupt configuration can be set in the “INT_CTRL” register. It affects INT_STATUS registers and the INT pin.
Table 38: Register 0x19 “INT_CTRL”
Name Description
Bit 0 int_od Configure output: open-drain or push-pull
0 push-pull
1 open-drain
Bit 1 int_level level of INT pin
0 active_low
1 active_high
Bit 2 int_latch Latching of interrupts for INT pin and INT_STATUS register
0 disabled
1 enabled
Bit 3 fwtm_en enable FIFO watermark reached interrupt for INT pin and INT_STATUS.
0 disabled
1 enabled
Bit 4 ffull_en enable Fifo full interrupt for INT pin and INT_STATUS
0 disabled
1 enabled
Bit 6 drdy_en enable temperature / pressure data ready interrupt for INT pin and
INT_STATUS
0 disabled
1 enabled
Page 36
4.3.15. Register 0x1A “IF_CONF”
The “IF_CONF” register controls the serial interface settings.
Table 39: Register 0x1A “IF_CONF”
Name Description
Configure SPI Interface Mode for primary interface
Bit 0 spi3 0 spi4 SPI 4-wire mode
1 spi3 SPI 3-wire mode
Enable for the I2C Watchdog timer, backed by NVM
Bit 1 i2c_wdt_en 0 disabled Watchdog disabled
1 enabled Watchdog enabled
Select timer period for I2C Watchdog , backed by NVM
Bit 2 i2c_wdt_sel 0 wdt_short I2C watchdog timeout after 1.25 ms
1 wdt_long I2C watchdog timeout after 40 ms
4.3.16. Register 0x1B “PWR_CTRL”
The “PWR_CTRL” register enables or disables pressure and temperature measurement. Although, the measurement mode
can be set here.
Table 40: Register 0x1B “PWR_CTRL”
Name Description
0 press_off Disables the pressure sensor.
Bit 0 press_en
1 press_on Enables the pressure sensor.
0 temp_off Disables the temperature sensor.
Bit 1 temp_en 1 temp_on Enables the temperature sensor.
00 sleep mode
Bit 5..4 mode 01/10 forced mode
11 normal mode
Page 37
4.3.17. Register 0x1C “OSR”
The “OSR” register controls the oversampling settings for pressure and temperature measurements.
Table 41: Register 0x1C “OSR”
Name Description
Bit 2..0 osr_p Oversampling setting pressure measurement
000 x1 no oversampling.
001 x2 x2 oversampling.
010 x4 x4 oversampling.
011 x8 x8 oversampling.
100 x16 x16 oversampling.
101 x32 x32 oversampling.
Bit 5..3 osr4_t Oversampling setting temperature measurement
000 x1 no oversampling
001 x2 x2 oversampling
010 x4 x4 oversampling
011 x8 x8 oversampling
100 x16 x16 oversampling
101 x32 x32 oversampling
4.3.18. Register 0x1D “ODR”
The “ODR” register set the configuration of the output data rates by means of setting the subdivision/subsampling.
Table 42: Register 0x1D “ODR”
Name Description
subdivision factor for pressure and temperature
Bit 4..0 odr_sel measurements is 2^value. Allowed values are 0..17.
Other values are saturated at 17.
Page 38
4.3.19. Control settings for odr_sel
Table 43: Control Settings settings for odr_sel
odr_sel prescaler Name Description Sampling Period
0x00 1 ODR_200 ODR 200Hz 5 ms
0x01 2 ODR_100 ODR 100Hz 10 ms
0x02 4 ODR_50 ODR 50Hz 20 ms
0x03 8 ODR_25 ODR 25Hz 40 ms
0x04 16 ODR_12p5 ODR 25/2Hz 80 ms
0x05 32 ODR_6p25 ODR 25/4Hz 160 ms
0x06 64 ODR_3p1 ODR 25/8Hz 320 ms
0x07 127 ODR_1p5 ODR 25/16Hz 640 ms
0x08 256 ODR_0p78 ODR 25/32Hz 1.280 s
0x09 512 ODR_0p39 ODR 25/64Hz 2.560 s
0x0A 1024 ODR_0p2 ODR 25/128Hz 5.120 s
0x0B 2048 ODR_0p1 ODR 25/256Hz 10.24 s
0x0C 4096 ODR_0p05 ODR 25/512Hz 20.48 s
0x0D 8192 ODR_0p02 ODR 25/1024Hz 40.96 s
0x0E 16384 ODR_0p01 ODR 25/2048Hz 81.92 s
0x0F 32768 ODR_0p006 ODR 25/4096Hz 163.84 s
0x10 65536 ODR_0p003 ODR 25/8192Hz 327.68 s
0x11 131072 ODR_0p0015 ODR 25/16384Hz 655.36 s
Page 39
4.3.20. Register 0x1F “CONFIG”
The “CONFIG” register controls the IIR filter coefficients.
Table 44: Register 0x1F “CONFIG”
Name Description
filter coefficient for IIR filter
000 coef_0 filter coefficient is 0 -> bypass-mode
001 coef_1 filter coefficient is 1
010 coef_3 filter coefficient is 3
Bit 3..1 iir_filter 011 coef_7 filter coefficient is 7
100 coef_15 filter coefficient is 15
101 coef_31 filter coefficient is 31
110 coef_63 filter coefficient is 63
111 coef_127 filter coefficient is 127
4.3.21. Register 0x30 .. 0x57 “calibration data”
The overview over the calibration data can be found in Chapter 3.11.1.
4.3.22. Register 0x7E “CMD”
The available commands of the “CMD” register are listed below.
Table 45: Register 0x7E “CMD”
Name Description
All Available commands
Bit 7..0 cmd
(Note: Register will always read as 0x00)
Table 46: available cmd commands listed below
Value Name Description
0x00 nop reserved. No command.
0x34 extmode_en_middle see extmode_en_last
Clears all data in the FIFO, does not change FIFO_CONFIG
0xB0 fifo_flush
registers
Triggers a reset, all user configuration settings are overwritten
0xB6 softreset
with their default state
Page 40
5. Digital interfaces
The BMP388 supports the I²C and SPI digital interfaces; it acts as a slave for both protocols. The I²C interface supports the
standard, fast and high speed modes. The SPI interface supports both SPI mode ‘00’ (CPOL = CPHA = ‘0’) and mode ‘11’
(CPOL = CPHA = ‘1’) in 4-wire and 3-wire configuration.
The following transactions are supported:
• Single byte write
• Multiple byte write (using pairs of register addresses and register data)
• Single byte read
• Multiple byte read (using a single register address which is auto-incremented)
5.1. Interface selection
Interface selection is done automatically based on CSB (chip select) status. If CSB is connected to VDDIO, the I²C interface is
active. If CSB is pulled down, the SPI interface is activated. After CSB has been pulled down once (regardless of whether
any clock cycle occurred), the I²C interface is disabled until the next power-on-reset. This is done in order to avoid
inadvertently decoding SPI traffic to another slave as I²C data. Since power-on-reset is only executed when both VDD and
VDDIO are established, there is no risk of incorrect protocol detection due to power-up sequence used. However, if I²C is to
be used and CSB is not directly connected to VDDIO but rather through a programmable pin, it must be ensured that this pin
already outputs the VDDIO level during power-on-reset of the device. If this is not the case, the device will be locked in SPI
mode and not respond to I²C commands.
5.2. I²C Interface
The I²C slave interface is compatible with Philips I²C Specification Revision 6 (April 2014). For detailed timings refer to Table
47. All modes (standard, fast, high speed) are supported. SDA and SCL are not pure open-drain. Both pads contain ESD
protection diodes to VDDIO and GND.
Figure 14: SDI/SCK ESD drawing
The 7-bit device address is 111011x. The 6 MSB bits are fixed. The last bit is changeable by SDO value and can be changed
during operation. Connecting SDO to GND results in slave address 1110110 (0x76); connection it to VDDIO results in slave
address 1110111 (0x77), which is the same as BMP180’s I²C address. The SDO pin cannot be left floating; if left floating, the
I²C address will be undefined.

Page 41
The I²C interface uses the following pins:
• SCK: serial clock (SCL)
• SDI: data (SDA)
• SDO: Slave address LSB (GND = ‘0’, VDDIO = ‘1’)
The CSB is not used and is left open. SDI is bi-directional with open drain to VSS: it must be externally connected to VDDIO
via a pull up resistor. Refer to chapter 6 for connection instructions.
The following abbreviations will be used in the I²C protocol figures:
• S Start
• P Stop
• ACKS Acknowledge by slave
• ACKM Acknowledge by master
• NACKM Not acknowledge by master
5.2.1. I²C write
Writing is done by sending the slave address in write mode (RW = ‘0’), resulting in slave address 111011X0 (‘X’ is determined
by state of SDO pin. Then the master sends pairs of register addresses and register data. The transaction is ended by a stop
condition. This is depicted in Figure 15.
Figure 15: I²C write
5.2.2. I²C read
To be able to read registers, first the register address must be sent in write mode (slave address 111011X0). Then either a
stop or a repeated start condition must be generated. After this the slave is addressed in read mode (RW = ‘1’) at address
111011X1, after which the slave sends out data from auto-incremented register addresses until a NOACKM and stop
condition occurs. This is depicted in Figure 16, where two bytes are read from register 0xF6 and 0xF7.
Figure 16: I²C multiple byte read

Page 42
5.3. SPI interface
The SPI interface is compatible with SPI mode ‘00’ (CPOL = CPHA = ‘0’) and mode ‘11’ (CPOL = CPHA = ‘1’). The automatic
selection between mode ‘00’ and ‘11’ is determined by the value of SCK after the CSB falling edge.
The SPI interface has two modes: 4-wire and 3-wire. The protocol is the same for both. The 3-wire mode is selected by
setting spi3=‘1’ in register “IF_CONF[0]” (see 4.3.13). The pad SDI is used as a data input/output pad in 3-wire mode.
The SPI interface uses the following pins:
• CSB: chip select, active low
• SCK: serial clock
• SDI: serial data input; data input/output in 3-wire mode
• SDO: serial data output; hi-Z in 3-wire mode
Refer to chapter 6 for connection instructions.
CSB is active low and has an integrated pull-up resistor. Data on SDI is latched by the device at SCK rising edge and SDO
is changed at SCK falling edge. Communication starts when CSB goes to low and stops when CSB goes to high; during
these transitions on CSB, SCK must be stable. The SPI protocol is shown in Figure 17.
CSB
SCK
SDI
RW AD6 AD5 AD4 AD3 AD2 AD1 AD0 DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
SDO
DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0 tri-state
Figure 17: SPI protocol (shown for mode ‘11’ in 4-wire configuration)
In SPI mode, only 7 bits of the register addresses are used; the MSB of register address is not used and replaced by a
read/write bit (RW = ‘0’ for write and RW = ‘1’ for read).
Example: address 0xF7 is accessed by using SPI register address 0x77. For write access, the byte 0x77 is transferred, for
read access, the byte 0xF7 is transferred.
5.3.1. SPI write
Writing is done by lowering CSB and sending pairs control bytes and register data. The control bytes consist of the SPI
register address (= full register address without bit 7) and the write command (bit7 = RW = ‘0’). Several pairs can be written
without raising CSB. The transaction is ended by a raising CSB. The SPI write protocol is depicted in Figure 18.
Figure 18: 4 wire SPI sequence
Figure 19: SPI multiple write

Page 43
5.3.2. SPI read
Reading is done by lowering CSB and first sending one control byte. The control bytes consist of the SPI register address (=
full register address without bit 7) and the read command (bit 7 = RW = ‘1’). After writing the control byte, one dummy byte
is sent and there after data bytes. The register address is automatically incremented. The SPI read protocol is shown in
Figure 20.
Figure 20: SPI multiple byte read
5.4. Interface parameter specification
5.4.1. General interface parameters
The general interface parameters are given in the table below:
Table 47: interface parameters
Parameter Symbol Condition Min Typ Max Units
0.25
Input – low level Vil SCK, SDI and CSB V
VDDIO
0.7
Input – high level Vih SCK, SDI and CSB V
VDDIO
SDI, SDO and INT, 0.2
Output – low level Vol V
iol=3 mA VDDIO
SDI, SDO and INT 0.8
Output – high level Voh V
ioh=1 mA VDDIO
Internal pull-up
CSB Pull-up resistor Rcsb 75 100 125 kΩ
resistance to VDDIO
I2C bus load capacitor Cb On SDI and SCK 400 pF
5.4.2. I²C timings
For I²C timings, the following abbreviations are used:
• “S&F mode” = standard and fast mode
• “HS mode” = high speed mode
• Cb = bus capacitance on SDA line
All other naming refers to I²C specification 2.1 (January 2000).
The I²C timing diagram is shown in
Figure 21. The corresponding values are given in Table 47.

Page 44
SDI
tBUF
tf
tLOW
SCK
tHIGH
tHDSTA tr tHDDAT
tSUDAT
SDI
tSUSTA
tSUSTO
Figure 21: I²C timing diagram
Table 48: I²C timings
Parameter Symbol Condition Min Typ Max Units
SCK frequency Fi2c 400 3400 kHz
S&F Mode 160 ns
SDI input setup time tSU;DAT
HS mode 30 ns
S&F Mode, Cb≤100 pF 80 ns
S&F Mode, Cb≤400 pF 90 ns
SDI output hold time tHD;DAT
HS mode, Cb≤100 pF 18 ns
HS mode, Cb≤400 pF 24 ns
HS mode, Cb≤100 pF
SCK low pulse tLOW 160 ns
VDDIO = 1.62 V
HS mode, Cb≤100 pF
SCK low pulse tLOW 210 ns
VDDIO = 1.2 V
The above-mentioned I2C specific timings correspond to the following internal added delays:
• Input delay between SDI and SCK inputs: SDI is more delayed than SCK by typically 120 ns in Standard and Fast
Modes and by typically 20 ns in High Speed Mode.
• Output delay from SCK falling edge to SDI output propagation is typically 140 ns in Standard and Fast Modes and
typically 70 ns in High Speed Mode.

Page 45
5.4.3. SPI timings
The SPI timing diagram is in Figure 22, while the corresponding values are given inTable 48. All timings apply both to 4- and
3-wire SPI.
T_setup_csb T_hold_csb
CSB
T_low_sck T_high_sck
SCK
SDI
T_setup_sdi T_hold_sdi
SDO
T_delay_sdo
Figure 22: SPI timing diagram
Table 49: SPI timings
Parameter Symbol Condition Min Typ Max Units
SPI clock input frequency F_spi 0 10 MHz
SCK low pulse T_low_sck 20 ns
SCK high pulse T_high_sck 20 ns
SDI setup time T_setup_sdi 20 ns
SDI hold time T_hold_sdi 20 ns
SDO output delay T_delay_sdo 25pF load, VDDIO=1.6V min 30 ns
SDO output delay T_delay_sdo 25pF load, VDDIO=1.2V min 40 ns
CSB setup time T_setup_csb 20 ns
CSB hold time T_hold_csb 20 ns

Page 46
6. Pin-out and connection diagram
6.1. Pin-out
Pin 1 Pin 1
2 1 indicator indicator
1 2
SCK VDDIO VDDIO SCK
3 10 10 3
VSS VDD VDD VSS
Port hole
4 9 9 4
SDI TOP VIEW VSS VSS BOTTOM VIEW SDI
(pads not visible) (pads visible)
5 8 8 5
SDO VSS VSS SDO
6 7 7 6
CSB INT INT CSB
Figure 23: Pin-out top and bottom view
Table 50: Pin description
Connect to
Pin Name I/O Type Description
SPI 4W SPI 3W I²C
Digital interface
1 VDDIO Supply VDDIO
supply
2 SCK In Serial clock input SCK SCK SCL
3 VSS Supply Ground GND
4 SDI In/Out Serial data input SDI SDI/SDO SDA
5 SDO In/Out Serial data output SDO DNC SA0
6 CSB In Chip select CSB CSB CSB
7 INT Out INT output host INT input or DNC
8 VSS Supply Ground GND
9 VSS Supply Ground GND
10 VDD Supply Analog supply VDD

Page 47
6.2. Connection diagram ¾-wire SPI
VDDIO SCK VDD
C1
Pin 1
2 1 indicator
SCK VDDIO
3 10
VSS= GND VSS VDD
C2
Port hole
SDI
4 9
(4 wire SPI)
SDI/SDO
SDI TOP VIEW VSS
(3 wire SPI) (pads not visible)
SDO 5 8
(4 wire SPI) SDO VSS
6 7
CSB INT
CSB INT VSS= GND
Figure 24: 3 and 4-wire SPI connection diagram (Pin1 marking indicated).
Note: the recommended value for C1, C2 is 100 nF.

Page 48
6.3. Connection diagram I²C
VDD
VDDIO VDDIO
R1
SCL
VDDIO
C1
Pin 1
2 1 indicator
SCK VDDIO
3 10
VSS VDD
C2
R2 VSS= GND
Port hole
4 9
SDI TOP VIEW VSS
(pads not visible)
SDA
I²C Address Pin Select 5 8
Addr.: 111011X SDO VSS
(Connect to VSS, X=‘0’) 6 7
(Connect to VDDIO, X=‘1’) CSB INT
VDDIO* INT VSS= GND
Figure 25: I²C connection diagram (Pin1 marking indicated)
Notes:
• the recommended value for C1, C2 is 100 nF and for R1, R2 is 4.7 kΩ.
• *: It is recommended to connect the BMP388 CSB pin to programmable pin which drives VDDIO at POR of device
(see Chapter 5.1)

Page 49
7. Package, reel and environment
7.1. Outline dimensions
The sensor housing is an 10-pin metal-lid LGA 2.0×2.0×0.75 mm3 package (typ.). Its dimensions are depicted in Figure 26.
Figure 26: Package outline dimensions BMP388 for top, bottom, side and 3D view
Note: General tolerances are ±50 µm (linear) and ±1 µm (angular)
7.2. Landing pattern
Bosch Sensortec suggests the BMP388 outline Dimensions (see 7.1- bottom view) as landing pattern.

Page 50
7.3. Marking
7.3.1. Mass production samples
Table 51: Marking of mass production samples
Labeling Name Symbol Remark
3 alphanumeric digits, variable
Lot Counter ID CCC
CCC to generate mass production trace code
FL Product number F
alphanumeric digit to identify product type,
“F” is associated with the product BMP388
(part number 0 273 300 511)
1 alphanumeric digit,
Sub-con ID L
variable to identify sub-con
Orientation
Vent hole
marker
7.3.2. Engineering samples
Table 52: Marking of engineering samples
Labeling Name Symbol Remark
1 alphanumeric digit, fixed
Eng. Sample ID R identification of sample status
R=”A” or “C” or “F”
RXX 2 alphanumeric digit, variable
Sample ID XX
identification of sample lot number
CCC
2 or 3 alphanumeric digits, variable
Counter ID CCC
to generate trace-code
Orientation
Vent hole
marker

Page 51
7.4. Soldering guidelines
The moisture sensitivity level of the BMP388 sensors corresponds to JEDEC Level 1, see also:
• IPC/JEDEC J-STD-020E “Joint Industry Standard: Moisture/Reflow Sensitivity Classification for non-hermetic Solid
State Surface Mount Devices”
• IPC/JEDEC J-STD-033D “Joint Industry Standard: Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive
Surface Mount Devices”.
The sensor fulfils the lead-free soldering requirements of the above-mentioned IPC/JEDEC standard, i.e. reflow soldering
with a peak temperature up to 260°C. The minimum height of the solder after reflow shall be at least 20 µm. This is required
for good mechanical decoupling between the sensor device and the printed circuit board (PCB).
Figure 27: Soldering profile

Page 52
7.5. Tape and reel specification
7.5.1. Dimensions
Figure 28: Tape and Reel dimensions
Quantity per reel: 10 kpcs.
7.5.2. Orientation within the reel
The orientation of the sensor placement inside the tape on reel can be found below.
Carrier
Sprocket hole
Cover tape foil
Port hole
CCC
CCC
CCC
CCC
EL
EL
EL
EL
Pocket
Tape: top side
Figure 29: Orientation within tape
7.6. Mounting and assembly recommendations
In addition to “Handling, soldering & mounting instructions BMP38x”, the following recommendations should be taken into
consideration when mounting a pressure sensor on a printed-circuit board (PCB):
• The clearance above the metal lid shall be 0.1mm at minimum.
• For the device housing appropriate venting needs to be provided in case the ambient pressure shall be measured.
• Liquids shall not come into direct contact with the device.
• During operation the sensor chip is sensitive to light, which can influence the accuracy of the measurement (photo-
current of silicon). The position of the vent hole minimizes the light exposure of the sensor chip. Nevertheless, BST
recommends to avoid the exposure of BMP388 to strong light sources.
• Soldering must not be done using vapor phase processes since the sensor might be damaged.

Page 53
7.7. Environmental safety
7.7.1. RoHS
The BMP388 sensor meets the requirements of the EC restriction of hazardous substances (RoHS) directive, see also:
Directive 2015/863 (amending Annex II to Directive 2011/65/EU) of the European Parliament and of the Council on the
restriction of the use of certain hazardous substances in electrical and electronic equipment.
7.7.2. Halogen content
The BMP388 is halogen-free. For more details on the analysis results please contact your Bosch Sensortec representative.
7.7.3. Internal package structure
Within the scope of Bosch Sensortec’s ambition to improve its products and secure the mass product supply, Bosch
Sensortec qualifies additional sources (e.g. 2nd source) for the LGA package of the BMP388.
While Bosch Sensortec took care that all of the technical packages parameters are described above are 100% identical for
all sources, there can be differences in the chemical content and the internal structural between the different package sources.
However, as secured by the extensive product qualification process of Bosch Sensortec, this has no impact to the usage or
to the quality of the BMP388 product.
Page 54
8. Legal disclaimer
8.1. Engineering samples
Engineering Samples are marked with an asterisk (*), (e) or (E). Samples may vary from the valid technical specifications of
the product series contained in this data sheet. They are therefore not intended or fit for resale to third parties or for use in
end products. Their sole purpose is internal client testing. The testing of an engineering sample may in no way replace the
testing of a product series. Bosch Sensortec assumes no liability for the use of engineering samples. The Purchaser shall
indemnify Bosch Sensortec from all claims arising from the use of engineering samples.
8.2. Product use
Bosch Sensortec products are developed for the consumer goods industry. They may only be used within the parameters of
this product data sheet. They are not fit for use in life-sustaining or safety-critical systems. Safety-critical systems are those
for which a malfunction is expected to lead to bodily harm, death or severe property damage. In addition, they shall not be
used directly or indirectly for military purposes (including but not limited to nuclear, chemical or biological proliferation of
weapons or development of missile technology), nuclear power, deep sea or space applications (including but not limited to
satellite technology).
Bosch Sensortec products are released on the basis of the legal and normative requirements relevant to the Bosch Sensortec
product for use in the following geographical target market: BE, BG, DK, DE, EE, FI, FR, GR, IE, IT, HR, LV, LT, LU, MT, NL,
AT, PL, PT, RO, SE, SK, SI, ES, CZ, HU, CY, US, CN, JP, KR, TW. If you need further information or have further requirements,
please contact your local sales contact.
The resale and/or use of Bosch Sensortec products are at the purchaser’s own risk and his own responsibility. The
examination of fitness for the intended use is the sole responsibility of the purchaser.
The purchaser shall indemnify Bosch Sensortec from all third party claims arising from any product use not covered by the
parameters of this product data sheet or not approved by Bosch Sensortec and reimburse Bosch Sensortec for all costs in
connection with such claims.
The purchaser accepts the responsibility to monitor the market for the purchased products, particularly with regard to product
safety, and to inform Bosch Sensortec without delay of all safety-critical incidents.
8.3. Application examples and hints
With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the
application of the device, Bosch Sensortec hereby disclaims any and all warranties and liabilities of any kind, including without
limitation warranties of non-infringement of intellectual property rights or copyrights of any third party. The information given
in this document shall in no event be regarded as a guarantee of conditions or characteristics. They are provided for
illustrative purposes only and no evaluation regarding infringement of intellectual property rights or copyrights or regarding
functionality, performance or error has been made.
Page 55
9. Appendix: Computation formulae reference implementation
The code below gives a provides a C implementation of the compensation algorithms discussed in Sec. 3.10.
The struct BMP388_calib_data is a structure, that contains the calibration coefficients. And the t_lin variable that carries a
temperature value over to the pressure compensation.
9.1. Calibration coefficient
The calibration coefficents are stored as described in Table 22. The compensation formula is implemented in floating point.
Therefore the coefficient have to be converted into floating point numbers by the following formulas.
𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇1 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇2 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇3
𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇1 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇2 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑇𝑇3 =
2−8 230 248
𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃1 − 214 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃2 − 214 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃3
𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃1 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃2 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃3 =
220 229 232
𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃4 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃5 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃6
𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃4 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃5 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃6 =
237 2−3 26
𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃7 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃8 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃9
𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃7 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃8 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃9 =
28 215 248
𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃10 𝑁𝑁𝑁𝑁𝑁𝑁_𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃11
𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃10 = 𝑃𝑃𝑃𝑃𝑃𝑃_𝑃𝑃11 =
248 265
9.2. Temperature compensation
static float BMP388_compensate_temperature(uint32_t uncomp_temp, struct BMP388_calib_data *calib_data)
{
float partial_data1;
float partial_data2;
partial_data1 = (float)(uncomp_temp – calib_data->par_t1);
partial_data2 = (float)(partial_data1 * calib_data->par_t2);
/* Update the compensated temperature in calib structure since this is
* needed for pressure calculation */
calib_data->t_lin = partial_data2 + (partial_data1 * partial_data1) * calib_data->par_t3;
/* Returns compensated temperature */
return calib_data->t_lin;
}
Page 56
9.3. Pressure compensation
static float BMP388_compensate_pressure(uint32_t uncomp_press, struct BMP388_calib_data *calib_data)
{
/* Variable to store the compensated pressure */
float comp_press;
/* Temporary variables used for compensation */
float partial_data1;
float partial_data2;
float partial_data3;
float partial_data4;
float partial_out1;
float partial_out2;
/* Calibration data */
partial_data1 = calib_data->par_p6 * calib_data->t_lin;
partial_data2 = calib_data->par_p7 * (calib_data->t_lin * calib_data->t_lin);
partial_data3 = calib_data->par_p8 * (calib_data->t_lin * calib_data->t_lin * calib_data->t_lin);
partial_out1 = calib_data->par_p5 + partial_data1 + partial_data2 + partial_data3;
partial_data1 = calib_data->par_p2 * calib_data->t_lin;
partial_data2 = calib_data->par_p3 * (calib_data->t_lin * calib_data->t_lin);
partial_data3 = calib_data->par_p4 * (calib_data->t_lin * calib_data->t_lin * calib_data->t_lin);
partial_out2 = (float)uncomp_press *
(calib_data->par_p1 + partial_data1 + partial_data2 + partial_data3);
partial_data1 = (float)uncomp_press * (float)uncomp_press;
partial_data2 = calib_data->par_p9 + calib_data->par_p10 * calib_data->t_lin;
partial_data3 = partial_data1 * partial_data2;
partial_data4 = partial_data3 + ((float)uncomp_press * (float)uncomp_press * (float)uncomp_press) * calib_data->par_p11;
comp_press = partial_out1 + partial_out2 + partial_data4;
return comp_press;
}
Page 57
10. Document history and modification
Rev. No Section Description of modification/changes Date
0.1 Document Creation 21.11.2016
7.4.2 Added 7.4.2 Orientation within the reel 13.03.2017
0.2
1 Added min/max data for restricted datasheet
0.3 7.1 Added warpage information 14.07.2017
1 Added min/max values and noise figures 18.10.2017
0.4 3.4.4 Updated noise values
3.5 Updated filter settings for different use cases
1.0 Final official version 15.01.2018
1.1 7.3.2 Change of laser marking definition 14.03.2018
1 Added missing sigma 25.04.2018
3 Changed coefficient from 128 to 127
3.11.1 Change 0x3B register content to NVM_PAR_P4
4.3.11 Greyed out unused bits
1.1
3.4 Updated reference links
3.4.2 Updated header number
4.3.11 Changed watermark name
7.3.2 Updated marking of engineering samples
Added new numeration 4.3.15. Register 0x1A 15.01.2019
4.3
“IF_CONF”
4.3.13 Table 36 01/10 changed to 11/10
1.2 4.3.9 Mark bit 1-7 as black for 0x13 FIFO_LENGTH_1
00 sleep mode
4.3.16 01/10 forced mode
11 normal mode
5.4.1 Update interface parameters 26.06.2019
1.3 8 Updated disclaimer
7.1 Updated outline dimensions 02.10.2019
8 Updated disclaimer
1.4 07.11.2019
Table 7 Updated IIR filter coefficients
3.9.1 Updated table 21 06.02.2020
7.4/7.7.1 Update JEDEC and ROHS standards
1.5
7.1 Updated drawing
6.1 Added I2C function 15.02.2020
Page 58
1 Added 10 KPa steps
4.2 Deleted sensortime_3 register 20.04.2020
1.6
3.4.1 Added example to reach 24 bits
8 New disclaimer 03.11.2020
1.7
3.2 Added VDDA and VDDD ramp-up conditions 23.11.2020
Page 59
Bosch Sensortec GmbH
Gerhard-Kindler-Straße 9
72770 Reutlingen / Germany
www.bosch-sensortec.com
Preliminary - specifications subject to change without notice
Document number: BST-BMP388-DS001-07
Revision_1.7_112020
Figures and diagrams from the PDF
Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.
Use this datasheet from any agent
Send the page, markdown, chunks, or search endpoint to ChatGPT, Claude, embedr-app, or your own tooling.
