BMP280 Digital Pressure Sensor
Absolute barometric pressure sensor with integrated temperature measurement for mobile and navigation applications.
Bosch Sensortec BMP280 Digital Pressure Sensor - Data sheet
Document BST-BMP280-DS001-26, revision 1.26, October 2021. Faithful per-page text transcription of the manufacturer PDF (sha256 473ff27d9df698b4757e36b36209f83b9f637b592c999d5fabe2a9453a488da6) produced with Poppler pdftotext because the configured parser returned HTTP 422. Figures are 130 dpi renders of the original PDF pages.
Page 1
BMP280
Digital Pressure Sensor
BMP280 – Data sheet
Document revision 1.26
Document release date October 2021
Document number BST-BMP280-DS001-26
Sales part number 0 273 300 436
Ordering code 0.273.300.436-1NV
Notes Data and descriptions in this document are subject to change without
notice. Product photos and pictures are for illustration purposes only
and may differ from the real product appearance
Page 2
BMP280
Digital Pressure Sensor
Key parameters
• Pressure range 300 … 1100 hPa
(equiv. to +9000…-500 m above/below sea level)
• Package 8-pin LGA metal-lid
Footprint : 2.0 × 2.5 mm², height: 0.95 mm
• Relative accuracy ±0.12 hPa, equiv. to ±1 m
(700 … 900hPa @25°C)
• Absolute accuracy typ. ±1 hPa
(950 ...1050 hPa, 0 ...+40 °C)
• Temperature coefficient offset 1.5 Pa/K, equiv. to 12.6 cm/K
(25 ... 40°C @900hPa)
• Digital interfaces I²C (up to 3.4 MHz)
SPI (3 and 4 wire, up to 10 MHz)
• Current consumption 2.7µA @ 1 Hz sampling rate
• Temperature range -40 … +85 °C
• RoHS compliant, halogen-free
• MSL 1
Typical applications
• Enhancement of GPS navigation
(e.g. time-to-first-fix improvement, dead-reckoning, slope detection)
• Indoor navigation (floor detection, elevator detection)
• Outdoor navigation, leisure and sports applications
• Weather forecast
• Vertical velocity indication (e.g. rise/sink speed)
Target devices
• Handsets such as mobile phones, tablet PCs, GPS devices
• Navigation systems
• Home weather stations
• Flying toys
• Watches
Page 3
General Description
Robert Bosch is the world market leader for pressure sensors in automotive and consumer
applications. Bosch’s proprietary APSM (Advanced Porous Silicon Membrane) MEMS manufacturing
process is fully CMOS compatible and allows a hermetic sealing of the cavity in an all silicon process.
The BMP280 is based on Bosch’s proven Piezo-resistive pressure sensor technology featuring high
EMC robustness, high accuracy and linearity and long term stability.
The BMP280 is an absolute barometric pressure sensor especially designed for mobile applications.
The sensor module is housed in an extremely compact 8-pin metal-lid LGA package with a footprint of
only 2.0 × 2.5 mm2 and 0.95 mm package height. Its small dimensions and its low power consumption
of 2.7 µA @1Hz allow the implementation in battery driven devices such as mobile phones, GPS
modules or watches.
As the successor to the widely adopted BMP180, the BMP280 delivers high performance in all
applications that require precise pressure measurement. The BMP280 operates at lower noise,
supports new filter modes and an SPI interface within a footprint 63% smaller than the BMP180.
The emerging applications of indoor navigation, fitness as well as GPS refinement require a high
relative accuracy and a low TCO at the same time. BMP180 and BMP280 are perfectly suitable for
applications like floor detection since both sensors feature excellent relative accuracy is ±0.12 hPa,
which is equivalent to ±1 m difference in altitude. The very low offset temperature coefficient (TCO) of
1.5 Pa/K translates to a temperature drift of only 12.6 cm/K.
Please contact your regional Bosch Sensortec partner for more information about software packages
enhancing the calculation of the altitude given by the BMP280 pressure reading.
Table 1: Comparison between BMP180 and BMP280
Parameter BMP180 BMP280
Footprint 3.6 × 3.8 mm 2.0 × 2.5 mm
Minimum VDD 1.80 V 1.71 V
Minimum VDDIO 1.62 V 1.20 V
Current consumption @3 Pa RMS noise 12 µA 2.7 µA
RMS Noise 3 Pa 1.3 Pa
Pressure resolution 1 Pa 0.16 Pa
Temperature resolution 0.1°C 0.01°C
Interfaces I²C I²C & SPI (3 and 4 wire,
mode ‘00’ and ‘11’)
Measurement modes Only P or T, forced P&T, forced or periodic
Measurement rate up to 120 Hz up to 157 Hz
Filter options None Five bandwidths
Page 4
Index of Contents
1. Specification ......................................................................................................................................7
2. Absolute maximum ratings ..............................................................................................................9
3. Functional description ................................................................................................................... 10
3.1 Block Diagram ......................................................................................................................... 11
3.2 Power management ................................................................................................................ 11
3.3 Measurement flow ................................................................................................................... 11
3.3.1 Pressure measurement .......................................................................................... 12
3.3.2 Temperature measurement .................................................................................... 13
3.3.3 IIR filter.................................................................................................................... 13
3.4 Filter selection.......................................................................................................................... 14
3.5 Noise ........................................................................................................................................ 15
3.6 Power modes ........................................................................................................................... 15
3.6.1 Sleep mode ............................................................................................................. 15
3.6.2 Forced mode ........................................................................................................... 15
3.6.3 Normal mode .......................................................................................................... 16
3.6.4 Mode transition diagram ......................................................................................... 17
3.7 Current consumption ............................................................................................................... 18
3.8 Measurement timings .............................................................................................................. 18
3.8.1 Measurement time .................................................................................................. 18
3.8.2 Measurement rate in normal mode ......................................................................... 19
3.9 Data readout ............................................................................................................................ 20
3.10 Data register shadowing .......................................................................................................... 20
3.11 Output compensation .............................................................................................................. 20
3.11.1 Computational requirements .................................................................................. 20
3.11.2 Trimming parameter readout .................................................................................. 21
3.11.3 Compensation formula............................................................................................ 21
3.12 Calculating pressure and temperature .................................................................................... 22
Page 5
4. Global memory map and register description............................................................................. 24
4.1 General remarks ...................................................................................................................... 24
4.2 Memory map ............................................................................................................................ 24
4.3 Register description ................................................................................................................. 24
4.3.1 Register 0xD0 “id” ................................................................................................... 24
4.3.2 Register 0xE0 “reset” .............................................................................................. 24
4.3.3 Register 0xF3 “status” ............................................................................................ 25
4.3.4 Register 0xF4 “ctrl_meas” ...................................................................................... 25
4.3.5 Register 0xF5 “config” ............................................................................................ 26
4.3.6 Register 0xF7…0xF9 “press” (_msb, _lsb, _xlsb) .................................................. 26
4.3.7 Register 0xFA…0xFC “temp” (_msb, _lsb, _xlsb) .................................................. 26
5. Digital interfaces ............................................................................................................................ 27
5.1 Interface selection ................................................................................................................... 27
5.2 I²C Interface ............................................................................................................................. 27
5.2.1 I²C write................................................................................................................... 28
5.2.2 I²C read ................................................................................................................... 29
5.3 SPI interface ............................................................................................................................ 29
5.3.1 SPI write.................................................................................................................. 30
5.3.2 SPI read .................................................................................................................. 30
5.4 Interface parameter specification ............................................................................................ 31
5.4.1 General interface parameters ................................................................................. 31
5.4.2 I²C timings ............................................................................................................... 31
5.4.3 SPI timings .............................................................................................................. 33
6. Pin-out and connection diagram .................................................................................................. 34
6.1 Pin-out ..................................................................................................................................... 34
6.2 Connection diagram 3-wire SPI ............................................................................................... 36
6.3 Connection diagram I2C........................................................................................................... 37
7. Package, reel and environment .................................................................................................... 38
7.1 Outline dimensions .................................................................................................................. 38
Page 6
7.2 Landing pattern recommendation ............................................................................................ 39
7.3 Marking .................................................................................................................................... 40
7.3.1 Mass production devices ........................................................................................ 40
7.3.2 Engineering samples .............................................................................................. 40
7.4 Soldering guidelines ................................................................................................................ 41
7.5 Tape and reel specification ...................................................................................................... 42
7.5.1 Dimensions ............................................................................................................. 42
7.5.2 Orientation within the reel ....................................................................................... 42
7.6 Mounting and assembly recommendations ............................................................................. 43
7.7 Environmental safety ............................................................................................................... 43
7.7.1 RoHS ...................................................................................................................... 43
7.7.2 Halogen content ...................................................................................................... 43
7.7.3 Internal package structure ...................................................................................... 43
8. Appendix 1: Computation formulae for 32 bit systems.............................................................. 44
8.1 Compensation formula in floating point ................................................................................... 44
8.2 Compensation formula in 32 bit fixed point ............................................................................. 44
9. Legal disclaimer ............................................................................................................................. 46
9.1 Engineering samples ............................................................................................................... 46
9.2 Product use.............................................................................................................................. 46
9.3 Application examples and hints ............................................................................................... 46
10. Document history and modification ............................................................................................. 47
Page 7
1. Specification
If not stated otherwise,
• All values are valid over the full voltage range
• All minimum/maximum values are given for the full accuracy temperature range
• Minimum/maximum values of drifts, offsets and temperature coefficients are ±3σ values over
lifetime
• Typical values of currents and state machine timings are determined at 25 °C
• Minimum/maximum values of currents are determined using corner lots over complete
temperature range
• Minimum/maximum values of state machine timings are determined using corner lots over
0…+65 °C temperature range
The specification tables are split into pressure and temperature part of BMP280.
Table 2: Parameter specification
Parameter Symbol Condition Min Typ Max Units
Operating temperature TA operational -40 25 +85 °C
range
full accuracy 0 +65
Operating pressure P full accuracy 300 1100 hPa
range
Sensor supply voltage VDD ripple max. 50mVpp 1.71 1.8 3.6 V
Interface supply voltage VDDIO 1.2 1.8 3.6 V
Supply current IDD,LP 1 Hz forced mode, 2.8 4.2 µA
pressure and
temperature, lowest
power
Peak current Ipeak during pressure 720 1120 µA
measurement
Current at temperature IDDT 325 µA
measurement
Sleep current 1 IDDSL 25 °C 0.1 0.3 µA
Standby current IDDSB 25 °C 0.2 0.5 µA
(inactive period of
normal mode) 2
Relative accuracy Arel 700 … 900hPa ±0.12 hPa
pressure 25 . . . 40 °C
VDD = 3.3V ±1.0 m
Offset temperature TCO 900hPa ±1.5 Pa/K
coefficient 25 . . . 40 °C
12.6 cm/K
1
Typical value at VDD = VDDIO = 1.8 V, maximal value at VDD = VDDIO = 3.6 V.
2
Typical value at VDD = VDDIO = 1.8 V, maximal value at VDD = VDDIO = 3.6 V.
Page 8
Absolute accuracy APext 300 . . 1100 hPa ±1.7 hPa
pressure -20 . . . 0 °C
APfull 300 . . . 1100 hPa ±1.0 hPa
0 . . . 65 °C
Resolution of RP Pressure 0.0016 hPa
output data in ultra high
resolution mode RT Temperature 0.01 °C
Noise in pressure Vp,full Full bandwidth, ultra 1.3 Pa
high resolution
See chapter 3.5 11 cm
Vp,filtered Lowest bandwidth, 0.2 Pa
ultra high resolution
See chapter 3.5 1.7 cm
Absolute accuracy AT @ 25 °C ±0.5 °C
temperature 3
0 . . . +65 °C ±1.0 °C
PSRR (DC) PSRR full VDD range ±0.005 Pa/
mV
Long term stability 4 ∆Pstab 12 months ±1.0 hPa
Solder drifts Minimum solder -0.5 +2 hPa
height 50 µm
Start-up time tstartup Time to first 2 ms
communication after
both VDD > 1.58V and
VDDIO > 0.65V
Possible sampling rate fsample osrs_t = osrs_p = 1; 157 182 tbd 5 Hz
See chapter 3.8
Standby time accuracy ∆tstandby ±5 ±25 %
3
Temperature measured by the internal temperature sensor. This temperature value depends on the PCB temperature, sensor
element self-heating and ambient temperature and is typically above ambient temperature.
4
Long term stability is specified in the full accuracy operating pressure range 0 … 65°C
5
Depends on application case, please contact Application Engineer for further questions
Page 9
2. Absolute maximum ratings
The absolute maximum ratings are provided in Table 3.
Table 3: Absolute maximum ratings
Parameter Condition Min Max Unit
Voltage at any supply pin VDD and VDDIO Pin -0.3 4.25 V
Voltage at any interface pin -0.3 VDDIO + 0.3 V
Storage Temperature ≤ 65% rel. H. -45 +85 °C
Pressure 0 20 000 hPa
ESD HBM, at any Pin ±2 kV
CDM ±500 V
Machine model ±200 V
Page 10
3. Functional description
The BMP280 consists of a Piezo-resistive pressure sensing element and a mixed-signal ASIC. The
ASIC performs A/D conversions and provides the conversion results and sensor specific
compensation data through a digital interface.
BMP280 provides highest flexibility to the designer and can be adapted to the requirements regarding
accuracy, measurement time and power consumption by selecting from a high number of possible
combinations of the sensor settings.
BMP280 can be operated in three power modes (see chapter 3.6):
• sleep mode
• normal mode
• forced mode
In sleep mode, no measurements are performed. Normal mode comprises an automated perpetual
cycling between an active measurement period and an inactive standby period. In forced mode, a
single measurement is performed. When the measurement is finished, the sensor returns to sleep
mode.
A set of oversampling settings is available ranging from ultra low power to ultra high resolution setting
in order to adapt the sensor to the target application. The settings are predefined combinations of
pressure measurement oversampling and temperature measurement oversampling. Pressure and
temperature measurement oversampling can be selected independently from 0 to 16 times
oversampling (see chapter 3.3.1 and 3.3.2):
• Temperature measurement
• Ultra low power
• Low power
• Standard resolution
• High resolution
• Ultra high resolution
BMP280 is equipped with a built-in IIR filter in order to minimize short-term disturbances in the output
data caused by the slamming of a door or window. The filter coefficient ranges from 0 (off) to 16.
In order to simplify the device usage and reduce the high number of possible combinations of power
modes, oversampling rates and filter settings, Bosch Sensortec provides a proven set of
recommendations for common use-cases in smart-phones, mobile weather stations or flying toys (see
chapter 3.3):
• Handheld device low-power (e.g. smart phones running Android)
• Handheld device dynamic (e.g. smart phones running Android)
• Weather monitoring (setting with lowest power consumption)
• Elevator / floor change detection
• Drop detection
• Indoor navigation
Page 11
3.1 Block Diagram
Figure 1 shows a simplified block diagram of the BMP280:
VDD VDDIO
Voltage Voltage
regulator reference
(analog &
digital) SDI
I
n
Pressure/ t
temperature Analog SDO
ADC e
sensing front-end Logic r
element f SCK
a
c
e CSB
OSC POR NVM
GND
Figure 1: Block diagram of BMP280
3.2 Power management
The BMP280 has two separate power supply pins
• VDD is the main power supply for all internal analog and digital functional blocks
• VDDIO is a separate power supply pin, used for the supply of the digital interface
A power-on reset generator is built in which resets the logic circuitry and the register values after the
power-on sequence. There are no limitations on slope and sequence of raising the VDD and VDDIO
levels. After powering up, the sensor settles in sleep mode (see 3.6.1).
Warning. Holding any interface pin (SDI, SDO, SCK or CSB) at a logical high level when VDDIO is
switched off can permanently damage the device due caused by excessive current flow through the
ESD protection diodes.
If VDDIO is supplied, but VDD is not, the interface pins are kept at a high-Z level. The bus can therefore
already be used freely before the BMP280 VDD supply is established.
3.3 Measurement flow
The BMP280 measurement period consists of a temperature and pressure measurement with
selectable oversampling. After the measurement period, the data are passed through an optional IIR
filter, which removes short-term fluctuations in pressure (e.g. caused by slamming a door). The flow is
depicted in the diagram below.

Page 12
Start
measurement cycle
Measure temperature
(oversampling set by osrs_t; IIR filter enabled? No
skip if osrs_t = 0)
Yes
Measure pressure Copy ADC values
(oversampling set by osrs_p; IIR filter initialised? No to filter memory
skip if osrs_p = 0) (initalises IIR filter)
Yes
Update filter memory using
Copy filter memory
filter memory, ADC value
to output registers
and filter coefficient
End
measurement cycle
Figure 2: BMP280 measurement cycle
The individual blocks of the diagram above will be detailed in the following subchapters.
3.3.1 Pressure measurement
Pressure measurement can be enabled or skipped. Skipping the measurement could be useful if
BMP280 is used as temperature sensor. When enabled, several oversampling options exist. Each
oversampling step reduces noise and increases the output resolution by one bit, which is stored in the
XLSB data register 0xF9. Enabling/disabling the measurement and oversampling settings are selected
through the osrs_p[2:0] bits in control register 0xF4.
Table 4: osrs_p settings
Oversampling setting Pressure Typical pressure Recommended
oversampling resolution temperature
oversampling
Pressure measurement Skipped – As needed
skipped (output set to 0x80000)
Ultra low power ×1 16 bit / 2.62 Pa ×1
Low power ×2 17 bit / 1.31 Pa ×1
Standard resolution ×4 18 bit / 0.66 Pa ×1
High resolution ×8 19 bit / 0.33 Pa ×1
Ultra high resolution ×16 20 bit / 0.16 Pa ×2
In order to find a suitable setting for osrs_p, please consult chapter 3.4.

Page 13
3.3.2 Temperature measurement
Temperature measurement can be enabled or skipped. Skipping the measurement could be useful to
measure pressure extremely rapidly. When enabled, several oversampling options exist. Each
oversampling step reduces noise and increases the output resolution by one bit, which is stored in the
XLSB data register 0xFC. Enabling/disabling the temperature measurement and oversampling setting
are selected through the osrs_t[2:0] bits in control register 0xF4.
Table 5: osrs_t settings
osrs_t[2:0] Temperature oversampling Typical temperature
resolution
000 Skipped –
(output set to 0x80000)
001 ×1 16 bit / 0.0050 °C
010 ×2 17 bit / 0.0025 °C
011 ×4 18 bit / 0.0012 °C
100 ×8 19 bit / 0.0006 °C
101, 110, 111 ×16 20 bit / 0.0003 °C
It is recommended to base the value of osrs_t on the selected value of osrs_p as per Table 4.
Temperature oversampling above ×2 is possible, but will not significantly improve the accuracy of the
pressure output any further. The reason for this is that the noise of the compensated pressure value
depends more on the raw pressure than on the raw temperature noise. Following the recommended
setting will result in an optimal noise-to-power ratio.
3.3.3 IIR filter
The environmental pressure is subject to many short-term changes, caused e.g. by slamming of a
door or window, or wind blowing into the sensor. To suppress these disturbances in the output data
without causing additional interface traffic and processor work load, the BMP280 features an internal
IIR filter. It effectively reduces the bandwidth of the output signals 6. The output of a next measurement
step is filter using the following formula:
data _ filtered _ old ⋅ ( filter _ coefficient − 1) + data _ ADC
data _ filtered =
filter _ coefficient
where data_filtered_old is the data coming from the previous acquisition, and data_ADC is the data
coming from the ADC before IIR filtering.
The IIR filter can be configured using the filter[2:0] bits in control register 0xF5 with the following
options:
6
Since most pressure sensors do not sample continuously, filtering can suffer from signals with a frequency higher than the
sampling rate of the sensor. E.g. environmental fluctuations caused by windows being opened and closed might have a frequency
<5 Hz. Consequently, a sampling rate of ODR = 10 Hz is sufficient to obey the Nyquist theorem.
Page 14
Table 6: filter settings
Filter coefficient Samples to reach ≥75 %
of step response
Filter off 1
2 2
4 5
8 11
16 22
In order to find a suitable setting for filter, please consult chapter 3.4.
When writing to the register filter, the filter is reset. The next value will pass through the filter and be
the initial memory value for the filter. If temperature or pressure measurement is skipped, the
corresponding filter memory will be kept unchanged even though the output registers are set to
0x80000. When the previously skipped measurement is re-enabled, the output will be filtered using the
filter memory from the last time when the measurement was not skipped.
3.4 Filter selection
In order to select optimal settings, the following use cases are suggested:
Table 7: Recommended filter settings based on use cases
Use case Mode Over- osrs_p osrs_t IIR IDD ODR RMS
sampling filter [µA] [Hz] Noise
setting coeff. (see (see [cm]
(see 3.7) 3.8.2) (see
3.3.3) 3.5)
handheld device Normal Ultra high ×16 ×2 4 247 10.0 4.0
low-power resolution
(e.g. Android)
handheld device Normal Standard ×4 ×1 16 577 83.3 2.4
dynamic resolution
(e.g. Android)
Weather Forced Ultra low ×1 ×1 Off 0.14 1/60 26.4
monitoring power
(lowest power)
Elevator / floor Normal Standard ×4 ×1 4 50.9 7.3 6.4
change detection resolution
Drop detection Normal Low ×2 ×1 Off 509 125 20.8
power
Indoor navigation Normal Ultra high ×16 ×2 16 650 26.3 1.6
resolution
Page 15
3.5 Noise
Noise depends on the oversampling and filter settings selected. The stated values were determined in
a controlled pressure environment and are based on the average standard deviation of 32 consecutive
measurement points taken at highest sampling speed. This is needed in order to exclude long term
drifts from the noise measurement.
Table 8: Noise in pressure
Typical RMS noise in pressure [Pa]
Oversampling setting IIR filter coefficient
off 2 4 8 16
Ultra low power 3.3 1.9 1.2 0.9 0.4
Low power 2.6 1.5 1.0 0.6 0.4
Standard resolution 2.1 1.2 0.8 0.5 0.3
High resolution 1.6 1.0 0.6 0.4 0.2
Ultra high resolution 1.3 0.8 0.5 0.4 0.2
Table 9: Noise in temperature
Typical RMS noise in temperature [°C]
Temperature oversampling IIR filter off
oversampling ×1 0.005
oversampling ×2 0.004
oversampling ×4 0.003
oversampling ×8 0.003
oversampling ×16 0.002
3.6 Power modes
The BMP280 offers three power modes: sleep mode, forced mode and normal mode. These can be
selected using the mode[1:0] bits in control register 0xF4.
Table 10: mode settings
mode[1:0] Mode
00 Sleep mode
01 and 10 Forced mode
11 Normal mode
3.6.1 Sleep mode
Sleep mode is set by default after power on reset. In sleep mode, no measurements are performed
and power consumption (IDDSM) is at a minimum. All registers are accessible; Chip-ID and
compensation coefficients can be read.
3.6.2 Forced mode
In forced mode, a single measurement is performed according to selected measurement and filter
options. When the measurement is finished, the sensor returns to sleep mode and the measurement
results can be obtained from the data registers. For a next measurement, forced mode needs to be
Page 16
selected again. This is similar to BMP180 operation. Forced mode is recommended for applications
which require low sampling rate or host-based synchronization.
current
osrs_t osrs_p
IDDP
IDDT
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement T
Measurement T
Measurement T
Measurement T
IDDSB
IDDSL
Write time
POR settings Mode[1:0] = 01 Data readout Mode[1:0] = 01
Figure 3: Forced mode timing diagram
3.6.3 Normal mode
Normal mode 16ontinuously cycles between an (active) measurement period and an
(inactive) standby period, whose time is defined by tstandby. The current in the standby period
(IDDSB) is slightly higher than in sleep mode. After setting the mode,measurement and filter
options, the last measurement results can be obtained from the data registers without the
need of further write accesses. Normal mode is recommended when using the IIR filter, and
useful for applications in which short-term disturbances (e.g. blowing into the sensor) should
be filtered.
current
osrs_t osrs_p tstandby
IDDP
IDDT
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement P
Measurement T
Measurement T
Measurement T
Measurement T
IDDSB
IDDSL
Write time
POR settings Mode[1:0] = 11 Data readout
when needed
Figure 4: Normal mode timing diagram
The standby time is determined by the contents of the t_sb[2:0] bits in control register 0xF5 according
to the table below:

Page 17
Table 11: t_sb settings
t_sb[1:0] tstandby [ms]
000 0.5
001 62.5
010 125
011 250
100 500
101 1000
110 2000
111 4000
3.6.4 Mode transition diagram
The supported mode transitions are displayed below. If the device is currently performing a
measurement, execution of mode switching commands is delayed until the end of the currently
running measurement period. Further mode change commands are ignored until the last mode
change command is executed. Mode transitions other than the ones shown below are tested for
stability but do not represent recommended use of the device.
Power OFF
(VDD or VDDIO = 0)
VDD and VDDIO Normal
(cyclic standby and
supplied 00 measurement periods)
[1:0] =
Mode
11
[1 :0] =
Mode Mode[1:0] = 01
Sleep
Mode[1:0
] = 01
Forced
(one measurement
period)
Figure 5: Mode transition diagram

Page 18
3.7 Current consumption
The current consumption depends on ODR and oversampling setting. The values given below are
normalized to an ODR of 1 Hz. The actual consumption at a given ODR can be calculated by
multiplying the consumption in Table 12 with the ODR used. The actual ODR is defined either by the
frequency at which the user sets forced measurements or by oversampling and tstandby settings in
normal mode in Table 14.
Table 12: Current consumption
Oversampling setting Pressure Temperature IDD [µA] @ 1 Hz forced mode
oversampling oversampling
Typ Max
Ultra low power ×1 ×1 2.74 4.16
Low power ×2 ×1 4.17 6.27
Standard resolution ×4 ×1 7.02 10.50
High resolution ×8 ×1 12.7 18.95
Ultra high resolution ×16 ×2 24.8 36.85
3.8 Measurement timings
The rate at which measurements can be performed in forced mode depends on the oversampling
settings osrs_t and osrs_p. The rate at which they are performed in normal mode depends on the
oversampling setting settings osrs_t and osrs_p and the standby time tstandby. In the following table the
resulting ODRs are given only for the suggested osrs combinations.
3.8.1 Measurement time
The following table explains the typical and maximum measurement time based on selected
oversampling setting. The minimum achievable frequency is determined by the maximum
measurement time.
Table 13: Measurement time
Oversampling Pressure Temperature Measurement Measurement
setting oversampling oversampling time [ms] rate [Hz]
Typ Max Typ Min
Ultra low power ×1 ×1 5.5 6.4 181.8 155.6
Low power ×2 ×1 7.5 8.7 133.3 114.6
Standard resolution ×4 ×1 11.5 13.3 87.0 75.0
High resolution ×8 ×1 19.5 22.5 51.3 44.4
Ultra high resolution ×16 ×2 37.5 43.2 26.7 23.1
Page 19
3.8.2 Measurement rate in normal mode
The following table explains which measurement rates can be expected in normal mode based on
oversampling setting and tstandby.
Table 14: typical output data Rate (ODR) in normal mode [Hz]
Oversampling tstandby [ms]
setting
0.5 62.5 125 250 500 1000 2000 4000
Ultra low power 166.67 14.71 7.66 3.91 1.98 0.99 0.50 0.25
Low power 125.00 14.29 7.55 3.88 1.97 0.99 0.50 0.25
Standard 83.33 13.51 7.33 3.82 1.96 0.99 0.50 0.25
resolution
High resolution 50.00 12.20 6.92 3.71 1.92 0.98 0.50 0.25
Ultra high 26.32 10.00 6.15 3.48 1.86 0.96 0.49 0.25
resolution
Table 15: Sensor timing according to recommended settings (based on use cases)
Use case Mode Over- osrs_p osrs_t IIR Timing ODR BW
sampling filter [Hz] [Hz]
setting coeff. (see (see
(see 3.8.2) 3.3.3)
3.3.3)
handheld device Normal Ultra high ×16 ×2 4 tstandby = 10.0 0.92
low-power (e.g. resolution 62.5 ms
Android)
handheld device Normal Standard ×4 ×1 16 tstandby = 83.3 1.75
dynamic (e.g. resolution 0.5 ms
Android)
Weather Forced Ultra low ×1 ×1 Off 1/min 1/60 full
monitoring power
(lowest power)
Elevator / floor Normal Standard ×4 ×1 4 tstandby = 7.3 0.67
change resolution 125 ms
detection
Drop detection Normal Low ×2 ×1 Off tstandby = 125 full
power 0.5 ms
Indoor Normal Ultra high ×16 ×2 16 tstandby = 26.3 0.55
navigation resolution 0.5 ms
Page 20
3.9 Data readout
To read out data after a conversion, it is strongly recommended to use a burst read and not address
every register individually. This will prevent a possible mix-up of bytes belonging to different
measurements and reduce interface traffic. Data readout is done by starting a burst read from 0xF7 to
0xFC. The data are read out in an unsigned 20-bit format both for pressure and for temperature. It is
strongly recommended to use the BMP280 API, available from Bosch Sensortec, for readout and
compensation. For details on memory map and interfaces, please consult chapters 3.12 and 5
respectively.
The timing for data readout in forced mode should be done so that the maximum measurement times
(see chapter 3.8.1) are respected. In normal mode, readout can be done at a speed similar to the
expected data output rate (see chapter 3.8.2). After the values of ‘ut’ and ‘up’ have been read, the
actual pressure and temperature need to be calculated using the compensation parameters stored in
the device. The procedure is elaborated in chapter 3.11.
3.10 Data register shadowing
In normal mode, measurement timing is not necessarily synchronized to readout. This means that new
measurement results may become available while the user is reading the results from the previous
measurement. In this case, shadowing is performed in order to guarantee data consistency.
Shadowing will only work if all data registers are read in a single burst read. Therefore, the user must
use burst reads if he does not synchronize data readout with the measurement cycle. Using several
independent read commands may result in inconsistent data.
If a new measurement is finished and the data registers are still being read, the new measurement
results are transferred into shadow data registers. The content of shadow registers is transferred into
data registers as soon as the user ends the burst read, even if not all data registers were read.
Reading across several data registers can therefore only be guaranteed to be consistent within one
measurement cycle if a single burst read command is used. The end of the burst read is marked by
the rising edge of CSB pin in SPI case or by the recognition of a stop condition in I2C case. After the
end of the burst read, all user data registers are updated at once.
3.11 Output compensation
The BMP280 output consists of the ADC output values. However, each sensing element behaves
differently, and actual pressure and temperature must be calculated using a set of calibration
parameters. The recommended calculation in chapter 3.11.3 uses fixed point arithmetic. In high-level
languages like Matlab™ or LabVIEW™, fixed-point code may not be well supported. In this case the
floating-point code in appendix 8.1 can be used as an alternative. For 8-bit micro controllers, the
variable size may be limited. In this case a simplified 32 bit integer code with reduced accuracy is
given in appendix 8.2.
3.11.1 Computational requirements
The table below shows the number of clock cycles needed for compensation calculations on a 32 bit
Cortex-M3 micro controller with GCC optimization level –O2. This controller does not contain a floating
point unit, so all floating-point calculations are emulated. Floating point is only recommended for PC
applications where an FPU is present.
Page 21
Table 16: Computational requirements for compensation formulas
Compensation of Number of clock cycles (ARM Cortex-M3)
32 bit integer 64 bit integer Double precision
Temperature ~46 – ~2400 7
Pressure ~112 8 ~1400 ~5400 7
3.11.2 Trimming parameter readout
The trimming parameters are programmed into the devices’ non-volatile memory (NVM) during
production and cannot be altered by the customer. Each compensation word is a 16-bit signed or
unsigned integer value stored in two’s complement. As the memory is organized into 8-bit words, two
words must always be combined in order to represent the compensation word. The 8-bit registers are
named calib00…calib25 and are stored at memory addresses 0x88…0xA1. The corresponding
compensation words are named dig_T# for temperature compensation related values and dig_P# for
pressure compensation related values. The mapping is shown in Table 17.
Table 17: Compensation parameter storage, naming and data type
Register Register Data type
Address content
LSB / MSB
0x88 / 0x89 dig_T1 unsigned short
0x8A / 0x8B dig_T2 signed short
0x8C / 0x8D dig_T3 signed short
0x8E / 0x8F dig_P1 unsigned short
0x90 / 0x91 dig_P2 signed short
0x92 / 0x93 dig_P3 signed short
0x94 / 0x95 dig_P4 signed short
0x96 / 0x97 dig_P5 signed short
0x98 / 0x99 dig_P6 signed short
0x9A / 0x9B dig_P7 signed short
0x9C / 0x9D dig_P8 signed short
0x9E / 0x9F dig_P9 signed short
0xA0 / 0xA1 reserved reserved
3.11.3 Compensation formula
Please note that it is strongly advised to use the API available from Bosch Sensortec to perform
readout and compensation. If this is not wanted, the code below can be applied at the user’s risk. Both
pressure and temperature values are expected to be received in 20 bit format, positive, stored in a 32
bit signed integer.
The variable t_fine (signed 32 bit) carries a fine resolution temperature value over to the pressure
compensation formula and could be implemented as a global variable.
7
Use only recommended for high-level programming languages like Matlab™ or LabVIEW™
8
Use only recommended for 8-bit micro controllers
Page 22
The data type “BMP280_S32_t” should define a 32 bit signed integer variable type and can usually be
defined as “long signed int”.
The data type “BMP280_U32_t” should define a 32 bit unsigned integer variable type and can usually
be defined as “long unsigned int”.
For best possible calculation accuracy, 64 bit integer support is needed. If this is not possible on your
platform, please see appendix 8.2 for a 32 bit alternative.
The data type “BMP280_S64_t” should define a 64 bit signed integer variable type, which on most
supporting platforms can be defined as “long long signed int”. The revision of the code is rev.1.1.
// Returns temperature in DegC, resolution is 0.01 DegC. Output value of “5123” equals 51.23
DegC.
// t_fine carries fine temperature as global value
BMP280_S32_t t_fine;
BMP280_S32_t bmp280_compensate_T_int32(BMP280_S32_t adc_T)
{
BMP280_S32_t var1, var2, T;
var1 = ((((adc_T>>3) – ((BMP280_S32_t)dig_T1<<1))) * ((BMP280_S32_t)dig_T2)) >> 11;
var2 = (((((adc_T>>4) – ((BMP280_S32_t)dig_T1)) * ((adc_T>>4) – ((BMP280_S32_t)dig_T1)))
>> 12) *
((BMP280_S32_t)dig_T3)) >> 14;
t_fine = var1 + var2;
T = (t_fine * 5 + 128) >> 8;
return T;
}
“”–
// Returns pressure in Pa as unsigned 32 bit integer in Q24.8 format (24 integer bits and 8
fractional bits).
// Output value of “24674867” represents 24674867/256 = 96386.2 Pa = 963.862 hPa
BMP280_U32_t bmp280_compensate_P_int64(BMP280_S32_t adc_P)
{
BMP280_S64_t var1, var2, p;
var1 = ((BMP280_S64_t)t_fine) – 128000;
var2 = var1 * var1 * (BMP280_S64_t)dig_P6;
var2 = var2 + ((var1*(BMP280_S64_t)dig_P5)<<17);
var2 = var2 + (((BMP280_S64_t)dig_P4)<<35);
var1 = ((var1 * var1 * (BMP280_S64_t)dig_P3)>>8) + ((var1 * (BMP280_S64_t)dig_P2)<<12);
var1 = (((((BMP280_S64_t)1)<<47)+var1))*((BMP280_S64_t)dig_P1)>>33;
if (var1 == 0)
{
return 0; // avoid exception caused by division by zero
}
p = 1048576-adc_P;
p = (((p<<31)-var2)*3125)/var1;
var1 = (((BMP280_S64_t)dig_P9) * (p>>13) * (p>>13)) >> 25;
var2 = (((BMP280_S64_t)dig_P8) * p) >> 19;
p = ((p + var1 + var2) >> 8) + (((BMP280_S64_t)dig_P7)<<4);
return (BMP280_U32_t)p;
3.12 Calculating pressure and temperature
The following figure shows the detailed algorithm for pressure and temperature measurement.
This algorithm is available to customers as reference C source code (“BMP28x_ API”) from Bosch
Sensortec and via its sales and distribution partners.
Page 23
Please contact your Bosch Sensortec representative for details.
Page 24
4. Global memory map and register description
4.1 General remarks
All communication with the device is performed by reading from and writing to registers. Registers
have a width of 8 bits. There are several registers which are reserved; they should not be written to
and no specific value is guaranteed when they are read. For details on the interface, consult chapter
5.
4.2 Memory map
The memory map is given in Table 18 below. Reserved registers are not shown.
Table 18: Memory map
Reset
Register Name Address bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
state
temp_xlsb 0xFC temp_xlsb<7:4> 0 0 0 0 0x00
temp_lsb 0xFB temp_lsb<7:0> 0x00
temp_msb 0xFA temp_msb<7:0> 0x80
press_xlsb 0xF9 press_xlsb<7:4> 0 0 0 0 0x00
press_lsb 0xF8 press_lsb<7:0> 0x00
press_msb 0xF7 press_msb<7:0> 0x80
config 0xF5 t_sb[2:0] filter[2:0] spi3w_en[0] 0x00
ctrl_meas 0xF4 osrs_t[2:0] osrs_p[2:0] mode[1:0] 0x00
status 0xF3 measuring[0] im_update[0] 0x00
reset 0xE0 reset[7:0] 0x00
id 0xD0 chip_id[7:0] 0x58
calib25...calib00 0xA1…0x88 calibration data individual
Reserved Calibration Control Data Status
Registers: Revision Reset
registers data registers registers registers
do not
Type: read only read / write read only read only read only write only
write
4.3 Register description
4.3.1 Register 0xD0 “id”
The “id” register contains the chip identification number chip_id[7:0], which is 0x58. This number can
be read as soon as the device finished the power-on-reset.
4.3.2 Register 0xE0 “reset”
The “reset” register contains the soft reset word reset[7:0]. If the value 0xB6 is written to the register,
the device is reset using the complete power-on-reset procedure. Writing other values than 0xB6 has
no effect. The readout value is always 0x00.
Page 25
4.3.3 Register 0xF3 “status”
The “status” register contains two bits which indicate the status of the device.
Table 19: Register 0xF3 “status”
Register 0xF3 Name Description
“status”
Bit 3 measuring[0] Automatically set to ‘1’ whenever a conversion is
running and back to ‘0’ when the results have been
transferred to the data registers.
Bit 0 im_update[0] Automatically set to ‘1’ when the NVM data are being
copied to image registers and back to ‘0’ when the
copying is done. The data are copied at power-on-
reset and before every conversion.
4.3.4 Register 0xF4 “ctrl_meas”
The “ctrl_meas” register sets the data acquisition options of the device.
Table 20: Register 0xF4 “ctrl_meas”
Register 0xF4 Name Description
“ctrl_meas”
Bit 7, 6, 5 osrs_t[2:0] Controls oversampling of temperature data. See
chapter 3.3.2 for details.
Bit 4, 3, 2 osrs_p[2:0] Controls oversampling of pressure data. See chapter
3.3.1 for details.
Bit 1, 0 mode[1:0] Controls the power mode of the device. See chapter
3.6 for details.
Table 21: register settings osrs_p
osrs_p[2:0] Pressure
oversampling
000 Skipped (output set to
0x80000)
001 oversampling ×1
010 oversampling ×2
011 oversampling ×4
100 oversampling ×8
101, Others oversampling ×16
Page 26
Table 22: register settings osrs_t
osrs_t[2:0] Temperature oversampling
000 Skipped (output set to 0x80000)
001 oversampling ×1
010 oversampling ×2
011 oversampling ×4
100 oversampling ×8
101, 110, 111 oversampling ×16
4.3.5 Register 0xF5 “config”
The “config” register sets the rate, filter and interface options of the device. Writes to the “config”
register in normal mode may be ignored. In sleep mode writes are not ignored.
Table 23: Register 0xF5 “config”
Register 0xF5 Name Description
“config”
Bit 7, 6, 5 t_sb[2:0] Controls inactive duration tstandby in normal mode.
See chapter 3.6.3 for details.
Bit 4, 3, 2 filter[2:0] Controls the time constant of the IIR filter. See
chapter 3.3.3 for details.
Bit 0 spi3w_en[0] Enables 3-wire SPI interface when set to ‘1’. See
chapter 5.3 for details.
4.3.6 Register 0xF7…0xF9 “press” (_msb, _lsb, _xlsb)
The “press” register contains the raw pressure measurement output data up[19:0]. For details on how
to read out the pressure and temperature information from the device, please consult chapter0.
Table 24: Register 0xF7 … 0xF9 “press”
Register 0xF7- Name Description
0xF9 “press”
0xF7 press_msb[7:0] Contains the MSB part up[19:12] of the raw pressure
measurement output data.
0xF8 press_lsb[7:0] Contains the LSB part up[11:4] of the raw pressure
measurement output data.
0xF9 (bit 7, 6, 5, 4) press_xlsb[3:0] Contains the XLSB part up[3:0] of the raw pressure
measurement output data. Contents depend on
temperature resolution, see table 5.
4.3.7 Register 0xFA…0xFC “temp” (_msb, _lsb, _xlsb)
The “temp” register contains the raw temperature measurement output data ut[19:0]. For details on
how to read out the pressure and temperature information from the device, please consult chapter 0.
Page 27
Table 25: Register 0xFA … 0xFC “temp”
Register 0xFA- Name Description
0xFC “press”
0xFA temp_msb[7:0] Contains the MSB part ut[19:12] of the raw
temperature measurement output data.
0xFB temp_lsb[7:0] Contains the LSB part ut[11:4] of the raw
temperature measurement output data.
0xFC (bit 7, 6, 5, 4) temp_xlsb[3:0] Contains the XLSB part ut[3:0] of the raw
temperature measurement output data. Contents
depend on pressure resolution, see Table 4.
5. Digital interfaces
The BMP280 supports the I²C and SPI digital interfaces; it acts as a slave for both protocols. The I²C
interface supports the Standard, Fast and High Speed modes. The SPI interface supports both SPI
mode ‘00’ (CPOL = CPHA = ‘0’) and mode ‘11’ (CPOL = CPHA = ‘1’) in 4-wire and 3-wire configuration.
The following transactions are supported:
• Single byte write
• multiple byte write (using pairs of register addresses and register data)
• single byte read
• multiple byte read (using a single register address which is auto-incremented)
5.1 Interface selection
Interface selection is done automatically based on CSB (chip select) status. If CSB is connected to
VDDIO, the I²C interface is active. If CSB is pulled down, the SPI interface is activated. After CSB has
been pulled down once (regardless of whether any clock cycle occurred), the I²C interface is disabled
until the next power-on-reset. This is done in order to avoid inadvertently decoding SPI traffic to
another slave as I²C data. Since power-on-reset is only executed when both VDD and VDDIO are
established, there is no risk of incorrect protocol detection due to power-up sequence used. However,
if I²C is to be used and CSB is not directly connected to VDDIO but rather through a programmable pin,
it must be ensured that this pin already outputs the VDDIO level during power-on-reset of the device. If
this is not the case, the device will be locked in SPI mode and not respond to I²C commands.
5.2 I²C Interface
The I²C slave interface is compatible with Philips I²C Specification version 2.1. For detailed timings
refer to Table 27. All modes (standard, fast, high speed) are supported. SDA and SCL are not pure
open-drain. Both pads contain ESD protection diodes to VDDIO and GND. As the devices does not
perform clock stretching, the SCL structure is a high-Z input without drain capability.
Page 28
VDDIO
SDI /SCL high-z level shifter
output driver (only for SDI)
GND GND
Figure 6: SDI/SCK ESD drawing
The 7-bit device address is 111011x. The 6 MSB bits are fixed. The last bit is changeable by SDO
value and can be changed during operation. Connecting SDO to GND results in slave address
1110110 (0x76); connection it to VDDIO results in slave address 1110111 (0x77), which is the same as
BMP180’s I²C address. The SDO pin cannot be left floating; if left floating, the I²C address will be
undefined.
The I²C interface uses the following pins:
• SCK: serial clock (SCL)
• SDI: data (SDA)
• SDO: Slave address LSB (GND = ‘0’, VDDIO = ‘1’)
CSB must be connected to VDDIO to select I²C interface. SDI is bi-directional with open drain to GND: it
must be externally connected to VDDIO via a pull up resistor. Refer to chapter 6 for connection
instructions.
The following abbreviations will be used in the I²C protocol figures:
• S Start
• P Stop
• ACKS Acknowledge by slave
• ACKM Acknowledge by master
• NACKM Not acknowledge by master
5.2.1 I²C write
Writing is done by sending the slave address in write mode (RW = ‘0’), resulting in slave address
111011X0 (‘X’ is determined by state of SDO pin. Then the master sends pairs of register addresses
and register data. The transaction is ended by a stop condition. This is depicted in Figure 7.
Control byte Data byte
Start Slave Address RW ACKS Register address (A0h) ACKS Register data - address A0h ACKS
S 1 1 1 0 1 1 X 0 1 0 1 0 0 0 0 0 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 …
Control byte Data byte
Register address (A1h) ACKS Register data - address A1h ACKS Stop
… 1 0 1 0 0 0 0 1 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 P
Figure 7: I²C multiple byte write (not auto-incremented)

Page 29
5.2.2 I²C read
To be able to read registers, first the register address must be sent in write mode (slave address
111011X0). Then either a stop or a repeated start condition must be generated. After this the slave is
addressed in read mode (RW = ‘1’) at address 111011X1, after which the slave sends out data from
auto-incremented register addresses until a NOACKM and stop condition occurs. This is depicted in
Figure 8, where two bytes are read from register 0xF6 and 0xF7.
Control byte
Start Slave Address RW ACKS Register address (F6h) ACKS
S 1 1 1 0 1 1 X 0 1 1 1 1 0 1 1 0
Data byte Data byte
Start Slave Address RW ACKS Register data - address F6h ACKM Register data - address F7h NOACKM Stop
S 1 1 1 0 1 1 X 1 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 P
Figure 8: I²C multiple byte read
5.3 SPI interface
The SPI interface is compatible with SPI mode ‘00’ (CPOL = CPHA = ‘0’) and mode ‘11’ (CPOL =
CPHA = ‘1’). The automatic selection between mode ‘00’ and ‘11’ is determined by the value of SCK
after the CSB falling edge.
The SPI interface has two modes: 4-wire and 3-wire. The protocol is the same for both. The 3-wire
mode is selected by setting ‘1’ to the register spi3w_en. The pad SDI is used as a data pad in 3-wire
mode.

Page 30
The SPI interface uses the following pins:
• CSB: chip select, active low
• SCK: serial clock
• SDI: serial data input; data input/output in 3-wire mode
• SDO: serial data output; hi-Z in 3-wire mode
Refer to chapter 6 for connection instructions.
CSB is active low and has an integrated pull-up resistor. Data on SDI is latched by the device at SCK
rising edge and SDO is changed at SCK falling edge. Communication starts when CSB goes to low
and stops when CSB goes to high; during these transitions on CSB, SCK must be stable. The SPI
protocol is shown in Figure 9. For timing details, please review Table 28
.
CSB
SCK
SDI
RW AD6 AD5 AD4 AD3 AD2 AD1 AD0 DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
SDO
DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0 tri-state
Figure 9: SPI protocol (shown for mode ‘11’ in 4-wire configuration)
In SPI mode, only 7 bits of the register addresses are used; the MSB of register address is not used
and replaced by a read/write bit (RW = ‘0’ for write and RW = ‘1’ for read).
Example: address 0xF7 is accessed by using SPI register address 0x77. For write access, the byte
0x77 is transferred, for read access, the byte 0xF7 is transferred.
5.3.1 SPI write
Writing is done by lowering CSB and sending pairs control bytes and register data. The control bytes
consist of the SPI register address (= full register address without bit 7) and the write command (bit7 =
RW = ‘0’). Several pairs can be written without raising CSB. The transaction is ended by a raising
CSB. The SPI write protocol is depicted in Figure 10.
Control byte Data byte Control byte Data byte
Start RW Register address (F4h) Data register - address F4h RW Register address (F5h) Data register - adress F5h Stop
CSB CSB
= 0 1 1 1 0 1 0 0 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 0 1 1 1 0 1 0 1 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 =
0 1
Figure 10: SPI multiple byte write (not auto-incremented)
5.3.2 SPI read
Reading is done by lowering CSB and first sending one control byte. The control bytes consist of the
SPI register address (= full register address without bit 7) and the read command (bit 7 = RW = ‘1’).
After writing the control byte, data is sent out of the SDO pin (SDI in 3-wire mode); the register address
is automatically incremented. The SPI read protocol is shown in Figure 11.

Page 31
Control byte Data byte Data byte
Start RW Register address (F6h) Data register - address F6h Data register - address F7h Stop
CSB CSB
= 1 1 1 1 0 1 1 0 bit15 bit14 bit13 bit12 bit11 bit10 bit9 bit8 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 =
0 1
Figure 11: SPI multiple byte read
5.4 Interface parameter specification
5.4.1 General interface parameters
The general interface parameters are given in Table 26 below.
Table 26: interface parameters
Parameter Symbol Condition Min Typ Max Units
Input – low level Vil_si VDDIO=1.2V to 3.6V 0.2 * V
VDDIO
Input – high level Vih_si VDDIO=1.2V to 3.6V 0.8 * V
VDDIO
Output – low level for I2C Vol_SDI VDDIO=1.62V, iol=3 mA 0.2 * V
VDDIO
Output – low level for I2C Vol_SDI VDDIO=1.20V, iol=3 mA 0.23 * V
_1.2 VDDIO
Output – low level Vol_SD VDDIO=1.62V, iol=1 mA 0.2 * V
O VDDIO
Output – low level Vol_SD VDDIO=1.20V, iol=1 mA 0.23 * V
O_1.2 VDDIO
Output – high level Voh VDDIO=1.62V, ioh=1 mA 0.8 * V
(SDO, SDI) VDDIO
Output – high level Voh_1.2 VDDIO=1.2V, ioh=1 mA 0.6 * V
(SDO, SDI) VDDIO
Pull-up resistor Rpull Internal pull-up 70 120 190 kΩ
resistance to VDDIO
I2C bus load capacitor Cb On SDI and SCK 400 pF
5.4.2 I²C timings
For I²C timings, the following abbreviations are used:
• “S&F mode” = standard and fast mode
• “HS mode” = high speed mode
• Cb = bus capacitance on SDA line
All other naming refers to I²C specification 2.1 (January 2000).
The I²C timing diagram is shown in
Figure 12. The corresponding values are given in Table 27

Page 32
.
SDI
tBUF
tf
tLOW
SCK
tHIGH
tHDSTA tr tHDDAT
tSUDAT
SDI
tSUSTA
tSUSTO
Figure 12: I²C timing diagram

Page 33
Table 27: I²C timings
Parameter Symbol Condition Min Typ Max Units
SDI setup time tSU;DAT S&F Mode 160 ns
HS mode 30 ns
SDI hold time tHD;DAT S&F Mode, Cb≤100 pF 80 ns
S&F Mode, Cb≤400 pF 90 ns
HS mode, Cb≤100 pF 18 115 ns
HS mode, Cb≤400 pF 24 150 ns
SCK low pulse tLOW HS mode, Cb≤100 pF 160 ns
VDDIO = 1.62 V
SCK low pulse tLOW HS mode, Cb≤100 pF 210 ns
VDDIO = 1.2 V
The above-mentioned I2C specific timings correspond to the following internal added delays:
• Input delay between SDI and SCK inputs: SDI is more delayed than SCK by typically
100 ns in Standard and Fast Modes and by typically 20 ns in High Speed Mode.
• Output delay from SCK falling edge to SDI output propagation is typically 140 ns in
Standard and Fast Modes and typically 70 ns in High Speed Mode.
5.4.3 SPI timings
The SPI timing diagram is in Figure 13, while the corresponding values are given in
Table 28. All timings apply both to 4- and 3-wire SPI.
T_setup_csb T_hold_csb
CSB
T_low_sck T_high_sck
SCK
SDI
T_setup_sdi T_hold_sdi
SDO
T_delay_sdo
Figure 13: SPI timing diagram

Page 34
Table 28: SPI timings
Parameter Symbol Condition Min Typ Max Units
SPI clock input frequency F_spi 0 10 MHz
SCK low pulse T_low_sck 20 ns
SCK high pulse T_high_sck 20 ns
SDI setup time T_setup_sdi 20 ns
SDI hold time T_hold_sdi 20 ns
SDO output delay T_delay_sdo 25pF load, VDDIO=1.6V min 30 ns
SDO output delay T_delay_sdo 25pF load, VDDIO=1.2V min 40 ns
CSB setup time T_setup_csb 20 ns
CSB hold time T_hold_csb 20 ns
6. Pin-out and connection diagram
6.1 Pin-out
8 1 1 8
VDD GND GND VDD
Vent hole Pin 1
marker
7 2 2 7
GND CSB CSB GND
TOP VIEW BOTTOM VIEW
(pads not visible) (pads visible)
6 3 3 6
VDDIO SDI SDI VDDIO
5 4 4 5
SDO SCK SCK SDO
Figure 14: Pin-out top and bottom view
Table 29: Pin description
Pin Name I/O Type Description Connect to
SPI 4W SPI 3W I²C
1 GND Supply Ground GND
2 CSB In Chip select CSB CSB VDDIO
3 SDI In/Out Serial data input SDI SDI/SDO SDA
4 SCK In Serial clock input SCK SCK SCL
5 SDO In/Out Serial data output SDO DNC GND for
default
address
6 VDDIO Supply Digital interface supply VDDIO
7 GND Supply Ground GND
8 VDD Supply Analog supply VDD

Page 35
Connection diagram 4-wire SPI
VDD VDDIO
8 1
VDD GND
Vent hole
7 2
CSB
GND CSB
TOP VIEW
(pads not visible)
6 3
SDI
VDDIO SDI
5 4
SDO SCK
SDO SCK
C1 C2
Figure 15: 4-wire SPI connection diagram (Pin1 marking indicated)
Note: the recommended value for C1, C2 is 100 nF.

Page 36
6.2 Connection diagram 3-wire SPI
VDD VDDIO
8 1
VDD GND
Vent hole
7 2
CSB
GND CSB
TOP VIEW
(pads not visible)
6 3
SDI/SDO
VDDIO SDI
5 4
SCK
SDO SCK
C1 C2
Figure 16: 3-wire SPI connection diagram (Pin1 marking indicated)
Note: the recommended value for C1, C2 is 100 nF.

Page 37
6.3 Connection diagram I2C
VDD VDDIO
8 1
VDD GND
Vent hole
7 2
GND CSB
TOP VIEW
(pads not visible)
6 3
SDA
VDDIO SDI
I2C address bit 0 5 4
SCL
GND: '0'; VDDIO: '1' SDO SCK
C1 C2
Figure 17: I²C connection diagram (Pin1 marking indicated)
Notes:
• The recommended value for C1, C2 is 100 nF.
• A direct connection between CSB and VDDIO is recommended. If CSB is detected as low during
startup, the interface will be locked into SPI mode. See chapter 5.1.

Page 38
7. Package, reel and environment
7.1 Outline dimensions
The sensor housing is an 8-pin metal-lid LGA 2.0 × 2.5× 0.95 mm3 package. Its dimensions are
depicted in Figure 18.
Figure 18: Package outline dimensions for top, bottom and side view
Note: General tolerances are ±50 µm (linear) and ±1° µm (angular)

Page 39
7.2 Landing pattern recommendation
For the design of the landing pattern, the following dimensioning is recommended:
0.5
0.35
8 1
7 2
2.50
0.325
6 3
0.65
5 4
0.55
2.0
Figure 19: Recommended landing pattern (top view); dimensions are in mm
Note: red areas demark exposed PCB metal pads.
• In case of a solder mask defined (SMD) PCB process, the land dimensions should be defined
by solder mask openings. The underlying metal pads are larger than these openings.
• In case of a non solder mask defined (NSMD) PCB process, the land dimensions should be
defined in the metal layer. The mask openings are larger than the these metal pads.

Page 40
7.3 Marking
7.3.1 Mass production devices
Table 30: Marking of mass production samples
Labeling Name Symbol Remark
Lot counter CCC
3 alphanumeric digits, variable
to generate mass production trace-code
Product number T
CCC 1 alphanumeric digit, fixed
to identify product type, T = “K”
TL “K” is associated with the product BMP280
Sub-con ID L
1 alphanumeric digit, variable to
identify subcon (L = “S”, “M” for new
variant, both part number 0273300436)
Orientation
Vent hole
marker
7.3.2 Engineering samples
Table 31: Marking of engineering samples
Labeling Name Symbol Remark
Eng. Sample ID N
1 alphanumeric digit, fixed to identify
engineering sample, N = “ * ” or “e” or
XXN “E”
CC Sample ID XX
2 alphanumeric digits, variable
to generate trace-code
Counter ID CC
2 alphanumeric digits, variable
to generate trace-code
Orientation
Vent hole
marker
Page 41
7.4 Soldering guidelines
The moisture sensitivity level of the BMP280 sensors corresponds to JEDEC Level 1, see also:
• IPC/JEDEC J-STD-020C “Joint Industry Standard: Moisture/Reflow Sensitivity Classification for non-
hermetic Solid State Surface Mount Devices”
• IPC/JEDEC J-STD-033A “Joint Industry Standard: Handling, Packing, Shipping and Use of Moisture/Reflow
Sensitive Surface Mount Devices”.
The sensor fulfils the lead-free soldering requirements of the above-mentioned IPC/JEDEC standard,
i.e. reflow soldering with a peak temperature up to 260°C. The minimum height of the solder after
reflow shall be at least 50µm. This is required for good mechanical decoupling between the sensor
device and the printed circuit board (PCB).
Figure 20: Soldering profile

Page 42
7.5 Tape and reel specification
7.5.1 Dimensions
Figure 21: Tape and Reel dimensions
Quantity per reel: 10 kpcs.
7.5.2 Orientation within the reel
PIN
1 2 3 4
8 7 6 5
reel direction
Figure 22: Orientation within tape

Page 43
7.6 Mounting and assembly recommendations
In addition to “Handling, soldering & mounting instructions BMP280”, the following recommendations
should be taken into consideration when mounting a pressure sensor on a printed-circuit board (PCB):
• The clearance above the metal lid shall be 0.1mm at minimum.
• For the device housing appropriate venting needs to be provided in case the ambient pressure
shall be measured.
• Liquids shall not come into direct contact with the device.
• During operation the sensor chip is sensitive to light, which can influence the accuracy of the
measurement (photo-current of silicon). The position of the vent hole minimizes the light
exposure of the sensor chip. Nevertheless, BST recommends to avoid the exposure of BMP280
to strong light sources.
• Soldering may not be done using vapor phase processes since the sensor might be damaged.
7.7 Environmental safety
7.7.1 RoHS
The BMP280 sensor meets the requirements of the EC restriction of hazardous substances (RoHS)
directive, see also: RoHS–Directive 2011/65/EU and its amendments, including the amendment
2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic
equipment.
7.7.2 Halogen content
The BMP280 is halogen-free. For more details on the analysis results please contact your Bosch
Sensortec representative.
7.7.3 Internal package structure
Within the scope of Bosch Sensortec’s ambition to improve its products and secure the mass product
supply, Bosch Sensortec qualifies additional sources (e.g. 2nd source) for the LGA package of the
BMP280.
While Bosch Sensortec took care that all of the technical packages parameters are described above
are 100% identical for all sources, there can be differences in the chemical content and the internal
structural between the different package sources.
However, as secured by the extensive product qualification process of Bosch Sensortec, this has no
impact to the usage or to the quality of the BMP280 product.
Page 44
8. Appendix 1: Computation formulae for 32 bit systems
8.1 Compensation formula in floating point
Please note that it is strongly advised to use the API available from Bosch Sensortec to perform
readout and compensation. If this is not wanted, the code below can be applied at the user’s risk. Both
pressure and temperature values are expected to be received in 20 bit format, positive, stored in a 32
bit signed integer.
The variable t_fine (signed 32 bit) carries a fine resolution temperature value over to the pressure
compensation formula and could be implemented as a global variable.
The data type “BMP280_S32_t” should define a 32 bit signed integer variable type and could usually
be defined as “long signed int”. The revision of the code is rev.1.1.
// Returns temperature in DegC, double precision. Output value of “51.23” equals 51.23 DegC.
// t_fine carries fine temperature as global value
BMP280_S32_t t_fine;
double bmp280_compensate_T_double(BMP280_S32_t adc_T)
{
double var1, var2, T;
var1 = (((double)adc_T)/16384.0 – ((double)dig_T1)/1024.0) * ((double)dig_T2);
var2 = ((((double)adc_T)/131072.0 – ((double)dig_T1)/8192.0) *
(((double)adc_T)/131072.0 – ((double) dig_T1)/8192.0)) * ((double)dig_T3);
t_fine = (BMP280_S32_t)(var1 + var2);
T = (var1 + var2) / 5120.0;
return T;
}
// Returns pressure in Pa as double. Output value of “96386.2” equals 96386.2 Pa = 963.862 hPa
double bmp280_compensate_P_double(BMP280_S32_t adc_P)
{
double var1, var2, p;
var1 = ((double)t_fine/2.0) – 64000.0;
var2 = var1 * var1 * ((double)dig_P6) / 32768.0;
var2 = var2 + var1 * ((double)dig_P5) * 2.0;
var2 = (var2/4.0)+(((double)dig_P4) * 65536.0);
var1 = (((double)dig_P3) * var1 * var1 / 524288.0 + ((double)dig_P2) * var1) / 524288.0;
var1 = (1.0 + var1 / 32768.0)*((double)dig_P1);
if (var1 == 0.0)
{
return 0; // avoid exception caused by division by zero
}
p = 1048576.0 – (double)adc_P;
p = (p – (var2 / 4096.0)) * 6250.0 / var1;
var1 = ((double)dig_P9) * p * p / 2147483648.0;
var2 = p * ((double)dig_P8) / 32768.0;
p = p + (var1 + var2 + ((double)dig_P7)) / 16.0;
return p;
}
8.2 Compensation formula in 32 bit fixed point
Please note that it is strongly advised to use the API available from Bosch Sensortec to perform
readout and compensation. If this is not wanted, the code below can be applied at the user’s risk. Both
pressure and temperature values are expected to be received in 20 bit format, positive, stored in a 32
bit signed integer.
The variable t_fine (signed 32 bit) carries a fine resolution temperature value over to the pressure
compensation formula and could be implemented as a global variable.
The data type “BMP280_S32_t” should define a 32 bit signed integer variable type and can usually be
defined as “long signed int”.
The data type “BMP280_U32_t” should define a 32 bit unsigned integer variable type and can usually
be defined as “long unsigned int”.
Compensating the pressure value with 32 bit integer has an accuracy of typically 1 Pa (1-sigma). At
very high filter levels this adds a noticeable amount of noise to the output values and reduces their
resolution.
// Returns temperature in DegC, resolution is 0.01 DegC. Output value of “5123” equals 51.23 DegC.
// t_fine carries fine temperature as global value
BMP280_S32_t t_fine;
BMP280_S32_t bmp280_compensate_T_int32(BMP280_S32_t adc_T)
{
BMP280_S32_t var1, var2, T;
Page 45
var1 = ((((adc_T>>3) – ((BMP280_S32_t)dig_T1<<1))) * ((BMP280_S32_t)dig_T2)) >> 11;
var2 = (((((adc_T>>4) – ((BMP280_S32_t)dig_T1)) * ((adc_T>>4) – ((BMP280_S32_t)dig_T1))) >> 12) *
((BMP280_S32_t)dig_T3)) >> 14;
t_fine = var1 + var2;
T = (t_fine * 5 + 128) >> 8;
return T;
}
// Returns pressure in Pa as unsigned 32 bit integer. Output value of “96386” equals 96386 Pa = 963.86 hPa
BMP280_U32_t bmp280_compensate_P_int32(BMP280_S32_t adc_P)
{
BMP280_S32_t var1, var2;
BMP280_U32_t p;
var1 = (((BMP280_S32_t)t_fine)>>1) – (BMP280_S32_t)64000;
var2 = (((var1>>2) * (var1>>2)) >> 11 ) * ((BMP280_S32_t)dig_P6);
var2 = var2 + ((var1*((BMP280_S32_t)dig_P5))<<1);
var2 = (var2>>2)+(((BMP280_S32_t)dig_P4)<<16);
var1 = (((dig_P3 * (((var1>>2) * (var1>>2)) >> 13 )) >> 3) + ((((BMP280_S32_t)dig_P2) * var1)>>1))>>18;
var1 =((((32768+var1))*((BMP280_S32_t)dig_P1))>>15);
if (var1 == 0)
{
return 0; // avoid exception caused by division by zero
}
p = (((BMP280_U32_t)(((BMP280_S32_t)1048576)-adc_P)-(var2>>12)))*3125;
if (p < 0x80000000)
{
p = (p << 1) / ((BMP280_U32_t)var1);
}
else
{
p = (p / (BMP280_U32_t)var1) * 2;
}
var1 = (((BMP280_S32_t)dig_P9) * ((BMP280_S32_t)(((p>>3) * (p>>3))>>13)))>>12;
var2 = (((BMP280_S32_t)(p>>2)) * ((BMP280_S32_t)dig_P8))>>13;
p = (BMP280_U32_t)((BMP280_S32_t)p + ((var1 + var2 + dig_P7) >> 4));
return p;
}
Page 46
9. Legal disclaimer
9.1 Engineering samples
Engineering Samples are marked with an asterisk (*), (E) or (e). Samples may vary from the valid
technical specifications of the product series contained in this data sheet. They are therefore not
intended or fit for resale to third parties or for use in end products. Their sole purpose is internal client
testing. The testing of an engineering sample may in no way replace the testing of a product series.
Bosch Sensortec assumes no liability for the use of engineering samples. The Purchaser shall indemnify
Bosch Sensortec from all claims arising from the use of engineering samples.
9.2 Product use
Bosch Sensortec products are developed for the consumer goods industry. They may only be used
within the parameters of this product data sheet. They are not fit for use in life-sustaining or safety-
critical systems. Safety-critical systems are those for which a malfunction is expected to lead to bodily
harm, death or severe property damage. In addition, they shall not be used directly or indirectly for
military purposes (including but not limited to nuclear, chemical or biological proliferation of weapons or
development of missile technology), nuclear power, deep sea or space applications (including but not
limited to satellite technology).
Bosch Sensortec products are released on the basis of the legal and normative requirements relevant
to the Bosch Sensortec product for use in the following geographical target market: BE, BG, DK, DE,
EE, FI, FR, GR, IE, IT, HR, LV, LT, LU, MT, NL, AT, PL, PT, RO, SE, SK, SI, ES, CZ, HU, CY, US, CN,
JP, KR, TW. If you need further information or have further requirements, please contact your local sales
contact.
The resale and/or use of Bosch Sensortec products are at the purchaser’s own risk and his own
responsibility. The examination of fitness for the intended use is the sole responsibility of the purchaser.
The purchaser shall indemnify Bosch Sensortec from all third party claims arising from any product use
not covered by the parameters of this product data sheet or not approved by Bosch Sensortec and
reimburse Bosch Sensortec for all costs in connection with such claims.
The purchaser accepts the responsibility to monitor the market for the purchased products, particularly
with regard to product safety, and to inform Bosch Sensortec without delay of all safety-critical incidents.
9.3 Application examples and hints
With respect to any examples or hints given herein, any typical values stated herein and/or any
information regarding the application of the device, Bosch Sensortec hereby disclaims any and all
warranties and liabilities of any kind, including without limitation warranties of non-infringement of
intellectual property rights or copyrights of any third party. The information given in this document shall
in no event be regarded as a guarantee of conditions or characteristics. They are provided for illustrative
purposes only and no evaluation regarding infringement of intellectual property rights or copyrights or
regarding functionality, performance or error has been made.
Page 47
10. Document history and modification
Rev. No Chapter Description of modification/changes Date
0.1 Document creation 2012-08-06
1.0 9.2 Change of product use 2013-11-26
Table 2 Update of min/max data (only for restricted
version)
Added comment on the sampling rate
1.1 1, 3.3.1 Changed value for resolution, values for 2014-02-10
osrs_p settings changed
5.2 Changed sentence and added drawing 2014-02-18
3.7 Added max values for current consumption 2014-05-08
1.11 4.5.3 Modified write in normal mode 2014-06-25
5.2 Modified SDI/SCK ESD drawing
1.12 1 Changed min/max values for standby current, 2014-07-12
only valid for 25 °C
Table 1 Pressure resolution 0.16Pa 2014-07-12
1.13 Page 2 New technical reference codes added 2014-11-12
7.3 New details about laser marking added
1.14 Table 6 Changed contents of table 2015-05-04
Page 1 Removed TRC 0 273 300 354 & 0273 300
391
Page 44 Updated RoHS directive to 2011/65/EU 2015-05-07
effective 8 June 2011
1.15 Page 2, 3 Modified target devices, applications 2015-10-15
1.16 Special customer-only 2016-01-28
1.17 7.3 Added all available TRC 2016-06-07
1.18 7.3 New marking 2016-11-02
1.19 Page 1 Update of technical reference code 2018-01-08
1.20 4.3.7 Modified typo in table header 2018-04-25
1.21 Template update 2018-09-17
1.22 9 Update of legal disclaimer 2019-11-07
1.23 9 Update disclaimer 2020-11-20
1.24 7.3 Updated marking 2021-07-12
7.7 Update Environmental safety
1.25 Page 1 Added ordering code 2021-09-28
Page 48
1.26 7.7 Update Environmental safety 2021-10-20
Page 49
Bosch Sensortec GmbH
Gerhard-Kindler-Straße 9
72770 Reutlingen / Germany
contact@bosch-sensortec.com
www.bosch-sensortec.com
Specifications subject to change without notice
Document number: BST-BMP280-DS001-26
Figures and diagrams from the PDF
Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.
Use this datasheet from any agent