Datasheet docs

GCT

USB4125-GF-A USB-C Power-Only Receptacle

USB Type-C receptacle with 6 contacts for power charging only.

USB connectorsUSB4125-GF-AUSB4125, USB4130, USB41356-contact USB Type-C receptacleUSB-C

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage1
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH


USB4125

USB4130

USB4135

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage2
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

1.0 SCOPE

This specification covers performance, tests and quality requirements for the USB Type C Receptacles, USB4125, USB4130 and USB4135.

2.0 PRODUCT NAME AND PART NUMBER

USB Type C Receptacles, USB4125, USB4130 and USB4135.

3.0 PRODUCT SHAPE, DIMENSIONS AND MATERIAL

Please refer to drawings.

4.0 RATINGS

4.1 Current rating: 3.00A collectively for VBUS pins(pins A9, B9)

4.25A collectively for GND pins(pins A12, B12)

1.25A for VCONN (pin A5/B5)

4.2 Voltage rating ……………………… 48V DC

4.3 Operating Temperature Range …… -30°C to $+ 8 5 ^ { \circ } \mathsf { C }$

5.0 TEST AND MEASUREMENT CONDITIONS

Product is designed to meet electrical, mechanical and environmental performance requirements specified below. All tests are performed in ambient conditions unless otherwise specified.

6.0 PERFORMANCE

Test NoItemTest ConditionRequirement
6.0.1Examination of ProductVisual, dimensional and functional inspection as per quality plan.Product shall meet requirements of product drawing and specification.
ReseatingManually plug/unplug 3 timesNo physical damage

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage3
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

6.1 Electrical Performance

Test NoItemTest ConditionRequirement
6.1.1Low Level Contact ResistanceThe low level contact resistance measurement is made from the solder tail of the receptacle to the soldering point of the plug. When measured at 20mV Max. open circuit at 100mA. Mated test contacts must be in a connector housing. In accordance with EIA-364-23, Test Condition B40mΩ max (initial)
6.1.2Insulation ResistanceBoth unmated and Mated connectors, apply 100V DC for 1 minute at sea level between adjacent terminal or ground. In accordance with EIA-364-21.100 MΩ Min (initial).
6.1.3Dielectric StrengthMate connectors, apply 100V AC (RMS) for 1 minute at sea level. In accordance with EIA-364-20.No Breakdown
6.1.4Contact current ratingA current of 3 A shall be applied collectively to VBUS pins (i.e., pins A9, B9) and 1.25 A shall be applied to the VCONN pin (i.e., B5) as applicable, terminated through the corresponding GND pins (i.e., pins A12, B12). A minimum current of 0.25 A shall also be applied individually to pin A5, as applicable.The temperature rise shall not exceed 30°C at the outside surface of the shell.

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage4
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

6.2 Mechanical Performance

Test NoItemTest ConditionRequirement
6.2.1Mating/Un-mating ForceMate/Un-mated at a speed of 12.5mm/min.In accordance with EIA-364-13.Mating force: within 5N to 20N (initial).Un-Mating force: within 8N to 20N up to 30cycles, within 6N to 20N after 20,000cycles
6.2.2Durability20,000 cycles at a cycle rate 500± 50 per hour.In accordance with EIA-364-09.(Replace the plug after 10K cycles)Un-Mating force: within 6N to 20NContact resistance: 50mΩ maxDielectric Strength: no breakdown
Durability (Preconditioning)50 cycles at a cycle rate 500± 50 per hourIn accordance with EIA-364-09.-
6.2.3VibrationEIA 364-28 Test Condition VII, Test Letter D 15 minutes in each of 3 mutually perpendicular directions. Both mating halves should be rigidly fixed so as not to contribute to the relative motion of one contact against another. The method of fixturing should be detailed in the test reportNo evidence of physical damage and no discontinuity longer than 1 microsecond.Contact resistance: 50mΩ max.
6.2.44-Axis ContinuityShall be tested for continuity under stress using a test fixtureNo evidence of physical damage and no discontinuity longer than 1 microsecond.

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage5
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

6.3 Environmental Performance and Others

Test NoItemTest ConditionRequirement
6.3.1Cyclic Temperature and Humidity TestCycle the connector between 25 °C ±3 °C at 80 % ±3% RH and 65 °C ±3 °C at 50 % ±3% RH. Ramp times should be 0.5 hour and dwell times should be 1.0 hour. Dwell times start when the temperature and humidity have stabilized within the specified levels. Perform 24 such cycles.Contact Resistance: 50mΩ Max.
6.3.2Salt SpraySubject mated connectors to 5±1% salt-solution concentration, 35±2°C for 24 hours. In accordance with EIA-364-26, Test Condition B.Shall meet visual requirements, No detrimental corrosion allowed in contact area and base metal exposed.
6.3.3Thermal ShockTemperature range from -55°C~+85°C .Start from -55°C. After 30 min. change to +85°C, change time is no more than 5min. Total 10 cycles. Test reference standard: EIA 364-32, test condition INo physical damage. Contact Resistance (Low Level) 50m max.
6.3.4SolderabilitySolder pot temperature: 250±5°C for 3~5 seconds. In accordance with EIA-364-52.95% of immersed area must show no voids, pin holes.
6.3.5Temperature life105°C without applied voltage for 120 hours. EIA-364-17, method AContact resistance: 50mΩ max
Temperature Life (preconditioning)105°C without applied voltage for 72 hours. EIA-364-17, method A-
6.3.6Mixed flowing gasEIA 364-65,Class II A Samples should be placed in an environmentally controlled ‘test chamber’ that is monitored by a gas analyzing system for controlled concentrations of the specified gas mixture. Test coupons shall also be used and the weight gain reported. Test duration is 7 days.Contact resistance: 50mΩ max
6.3.7Thermal disturbanceCycle the connector or socket between 15 °C ±3 °C and 85 °C ±3 °C, as measured on the part. Ramps should be a minimum of 2 °C per minute, and dwell times should insure that the contacts reach the temperature extremes (a minimum of 5 minutes). Humidity is not controlled. Perform 10 such cycles.Contact resistance: 50mΩ max

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage6
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

7.0 RESISTANCE TO INFRARED REFLOW SOLDERING HEAT

ParameterReferenceSpecification
Average temperature gradient in preheating2.5°C/s
Soak time $T_{soak}$ 2-3 minutes
Time above 217°C $T_1$ 60
Time above 230°C $T_2$ 50
Time above 250°C $T_3$ 5
Peak temperature in reflow $T_{peak}$ 255°C(-0/+5°C)
Temperature gradient in cooling-5°C/s max

Lead Free Process

This profile is the minimum requirement for evaluating soldering heat resistance of components. Heat transfer method used for reflow soldering is hot air convection. The actual air temperatures used to achieve the specified profile is higher and largely dependent on the reflow equipment.

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage7
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

8.0 PRODUCT QUALIFICATION AND TEST SEQUENCE

Note: each group test needs 5pcs samples.

Test NoDescriptionRequirement
Group A-1
6.0.1ExaminationVisual inspection; No physical damage
6.1.1LLCR40mΩ Max all contacts
6.2.2Durability (preconditioning)50 cycles; No physical damage
6.3.5Temperature Life
6.1.1LLCR50mΩ Max all contacts
6.0.1ReseatingNo physical damage
6.1.1LLCR50mΩ Max all contacts
6.0.1ExaminationVisual inspection; No physical damage
Group A-2
6.0.1ExaminationVisual inspection; No physical damage
6.1.1LLCR40mΩ Max all contacts
6.2.2Durability (preconditioning)50 cycles; No physical damage
6.3.3Thermal Shock
6.1.1LLCR50mΩ Max all contacts
6.3.1Humidity
6.1.1LLCR50mΩ Max all contacts
6.0.1ReseatingNo physical damage
6.1.1LLCR50mΩ Max all contacts
6.0.1ExaminationVisual inspection; No physical damage
Group A-3
6.0.1ExaminationVisual inspection; No physical damage
6.1.1LLCR40mΩ Max all contacts

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage8
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH
6.2.2Durability (preconditioning)50 cycles; No physical damage
6.3.5Temperature Life (preconditioning)
6.1.1LLCR50mΩ Max all contacts
6.2.3VibrationDiscontinuity less than 1μs
6.1.1LLCR50mΩ Max all contacts
6.0.1ExaminationVisual inspection; No physical damage
Group A-4
6.0.1ExaminationVisual inspection; No physical damage
6.1.1LLCR40mΩ Max all contacts
6.2.2Durability (preconditioning)50 cycles; No physical damage
6.3.5Temperature Life (preconditioning)
6.1.1LLCR50mΩ Max all contacts
6.3.6Mixed Flowing Gases
6.1.1LLCR50mΩ Max all contacts
6.3.7Thermal Disturbance
6.1.1LLCR50mΩ Max all contacts
6.0.1ReseatingNo physical damage
6.1.1LLCR50mΩ Max all contacts
6.0.1ExaminationVisual inspection; No physical damage
Group A-7
6.0.1ExaminationVisual inspection; No physical damage
6.1.3DWVNo breakdown or flashover
6.1.1LLCR40mΩ Max all contacts
6.2.2Durability (preconditioning)No physical damage
6.2.1Insertion ForceWithin the range of 5N to 20N.
6.2.1Extraction forceWithin the range of 8N to 20N. Initial Reading
6.2.2Durability25cycles, No physical damage

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage9
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH
6.2.1Extraction forceWithin: a) 33% of initial reading & b) 8N to 20N
6.2.2DurabilityPerform 2468 cycles and then rotate the plug or socket 180° and then perform 2500 cycles. rotate the plug or socket 180° each 2500 cycles.No Physical damage.(Replace the plug after 10K cycles)
6.2.1Extraction forceWithin the range of 6N to 20N.
6.1.1LLCR50mΩ Max all contacts
6.1.3DWVNo breakdown or flashover
6.1.2Insulation Resistance100 MΩ Max.
6.0.1ExaminationVisual inspection; No physical damage
Group B-1
6.0.1ExaminationVisual inspection; No physical damage
6.2.44-Axis ContinuityDiscontinuity less than 1μs
6.0.1ExaminationVisual inspection; No physical damage
Group B-6
6.0.1ExaminationVisual inspection; No physical damage
6.1.5Contact Current RatingThe Temperature Rise shall not exceed 30°C
6.0.1ExaminationVisual inspection; No physical damage

PRODUCT SPECIFICATION

Part NumberUSB4125, USB4130, USB4135RevA3Date20/12/24
Product DescriptionUSB Type C Receptacle, 6 contacts, For Power Charging onlyPage10
Doc NumberUSB Type CPreparedYRCheckedCCApprovedPH

Revision details:

RevisionInformationPageRelease Date
ASpecification released.-25/11/20
A1Change USB4125 durability from 10000 cycles to 20000 cycles326/05/21
A2Add USB4135 to the specification1&218/02/22
A3- Voltage rating increased to 48Vdc- Durability increased to 20K cycles2, 4 & 920/12/2024