Datasheet docs

{ "name": "Bosch Sensortec", "mpn": "BME688" }

Bosch Sensortec BME688 Gas/RH/Pressure/Temperature Sensor

Bosch Sensortec BME688 4-in-1 environmental sensor with gas, relative humidity, pressure, and temperature sensing plus AI/BSEC gas scan support over I2C or SPI.

Sensor

BME688 Digital low power gas, pressure, temperature & humidity sensor with AI

BME688 – Datasheet

Document revision 1.3

Document release date

Document number

February, 2024 BST-BME688-DS000-03

Technical reference code(s)

0 273 017 016

Notes

Data and descriptions in this document are subject to change without notice. Product photos and pictures are for illustration purposes only and may differ from the real product appearance.

BME688

Digital low power gas, pressure, temperature & humidity sensor with AI

The BME688 is the first gas sensor with Artificial Intelligence (AI) and integrated high-linearity and high-accuracy pressure, humidity and temperature sensors. It is housed in a robust yet compact 3.0 x 3.0 x 0.9 mm³ package and especially developed for mobile & connected applications where size and low power consumption are critical requirements. The gas sensor can detect Volatile Organic Compounds (VOCs), volatile sulfur compounds (VSCs) and other gases such as carbon monoxide and hydrogen in the part per billion (ppb) range.

Additionally to all features of the BME680, the BME688 has a gas scanner function. In standard configuration, the presence of VSCs is being detected as indicator for e.g. bacteria growth. And the gas scanner can be customized with respect to sensitivity, selectivity, data rate and power consumption as well. The BME AI-Studio tool enables customers to train the BME688 gas scanner on their specific application, like in home appliances, IoT products or Smart Home.

Typical applications

Indoor air quality measurement

Bad breath or spoiled food detection based on the measurement of volatile sulfur compounds, which are an indicator of bacteria growth

Detection of unusual gases and smells, which might indicate for instance a leakage

Diaper state detection, e.g. for baby care

Early detection of odors & bad smells

Target Devices

Handsets such as mobile phones, tablet PCs, GPS devices

Wearables e.g. smart watches or connected sensors

Mobile / care devices like toothbrushes or breath checkers

Smart home devices, e.g. smart speakers, connected sensors or lamps

Room climate sensors

Home appliances

Gaming, e.g. flying toys

Connected devices, for instance for asset tracking or surveillance

Sensor networks / sensor nodes

Videos, further documents & software is available online:

BME688: https://www.bosch-sensortec.com/products/environmental-sensors/gas-sensors/bme688/

Software: https://www.bosch-sensortec.com/software-tools/software/bme688-software/

Key features

Package 3.0 mm x 3.0 mm x 0.93 mm metal lid LGA

Digital interface I²C (up to 3.4 MHz) and SPI (3 and 4 wire, up to 10 MHz)

Supply voltage VDD main supply voltage range: 1.71 V to 3.6 V

VDDIO interface voltage range: 1.2 V to 3.6 V

Current consumption

2.1 µA at 1 Hz humidity and temperature

3.1 µA at 1 Hz pressure and temperature

3.7 µA at 1 Hz humidity, pressure and temperature

90 µA at ULP mode for p/h/T & air quality

0,9 mA at LP mode for p/h/T & air quality

3,9 mA in standard gas scan mode

0.09‒12 mA for p/h/T/gas in customized operation modes

0.15 µA in sleep mode

Operating range -40‒+85 °C, 0‒100% r.H., 300‒1100 hPa

The product is RoHS compliant, halogen-free, MSL1

Key parameters for gas sensor

F1 score for H2S scanning 0.94

Standard scan speed 10.8 s / scan

Electric charge for standard scan 0.18 mAh (5 scans ~ 1 min)

Power consumption < 0.1 mA in ultra-low power mode

Output data processing Major direct outputs: Index for Air Quality (IAQ), bVOC- & CO2-equivalents (ppm),

Gas scan result (%) & Intensity level (all listed in Table 20: BSEC outputs)

Key parameters for humidity sensor

Response time (�0−63%) ~8 s

Accuracy tolerance ±3% r.H.

Hysteresis ±1.5% r.H.

Key parameters for pressure sensor

RMS Noise 0.12 Pa, equiv. to 1.7 cm

Offset temperature coefficient ±1.3 Pa/K, equiv. to ±10.9 cm at 1 °C temperature change

Key parameters for temperature sensor

Absolute accuracy ±0.5 °C (0 - 65°C)

Key hardware & software tools for the BME688

BME688 Development Kit & App for mobile devices

BME AI-Studio Desktop & Server software for use-case testing & development

BSEC 2.x library for system µC w/ integration code examples

Sensor API (driver) w/ code examples

Table of contents

  1. Specification 7
    1.1 General Electrical Specification ....7
    1.2 Gas sensor specification....8
    1.3 Humidity sensor specification....12
    1.4 Pressure sensor specification....13
    1.5 Temperature sensor specification....14

  2. Absolute maximum ratings 15

  3. Sensor usage 16
    3.1 Use cases....16
    3.2 Selectivity....16
    3.3 Indoor-air-quality....16
    3.4 Sensor modes....17
    3.5 Sensor configuration....19
    3.5.1 Quick start – Forced mode....19
    3.5.2 Sensor configuration flow – Forced mode....19
    3.5.3 Quick start – Parallel mode....20
    3.5.4 Sensor configuration flow – Parallel mode....20
    3.6 Measurement flow....22
    3.6.1 Temperature measurement....22
    3.6.2 Pressure measurement....23
    3.6.3 Humidity measurement....25
    3.6.4 IIR filter....26
    3.6.5 Gas sensor heating and measurement....27
    3.7 Data readout....28
    3.7.1 Gas resistance readout....28

  4. Software 30
    4.1 BME software components....30
    4.2 BME software library - BSEC software....30

  5. Global memory map and register description 32
    5.1 General remarks....32
    5.2 Memory map....33
    5.3 Register description....35
    5.3.1 General control registers....35
    5.3.2 Sensor identification registers....36
    5.3.3 Temperature, pressure and relative humidity control registers....36
    5.3.4 Gas control registers....38
    5.3.5 Data registers....41
    5.3.6 Status registers....43

  6. Digital interfaces 45
    6.1 Interface selection....45
    6.2 I²C Interface....45
    6.2.1 I²C write....46
    6.2.2 I²C read....46
    6.3 SPI interface....47
    6.3.1 SPI write....47
    6.3.2 SPI read....48
    6.4 Interface parameter specification....48
    6.4.1 General interface parameters....48
    6.4.2 I²C timings....49
    6.4.3 SPI timings....50

  7. Pin-out and connection diagram 51
    7.1 Pin-out....51
    7.2 Connection diagrams....52
    7.3 Package dimensions....53
    7.4 Landing pattern recommendation....54
    7.5 Marking....55
    7.5.1 Mass production devices....55
    7.5.2 Engineering samples....55
    7.6 Soldering guidelines and reconditioning recommendations....56
    7.7 Mounting and assembly recommendations....56
    7.8 Environmental safety....57
    7.8.1 RoHS....57
    7.8.2 Halogen content....57
    7.8.3 Internal package structure....57

  8. Legal disclaimer 58
    8.1 Engineering samples....58
    8.2 Product use....58
    8.3 Application examples and hints....58

9. Document history and modifications

1. Specification

If not stated otherwise,

all values are valid over the full voltage range,

all minimum/maximum values are given for the full accuracy temperature range

minimum/maximum values of drifts, offsets and temperature coefficients are ±3 values over lifetime,

typical values of currents and state machine timings are determined at $2 5 ^ { \circ } \mathsf C ,$

minimum/maximum values of currents are determined using corner lots over complete temperature range, and

minimum/maximum values of state-machine timings are determined using corner lots over $0 \mathrm { - } \mathrm { + } 6 5 ^ { \circ } \mathrm { C }$ temperature range.

Besides the general electrical specifications, the following tables are separated for the gas, pressure, humidity and temperature functions of the BME688.

1.1 General Electrical Specification

Table 1: Electrical parameter specification

OPERATING CONDITIONS BME688
ParameterSymbolConditionMinTypMaxUnit
Supply Voltage Internal Domains1 $V_{DD}$ ripple max. 50 mVpp1.711.83.6V
Supply Voltage I/O Domain $V_{DDIO}$ 1.21.63.6V
Sleep current $I_{DDSL}$ 0.151μA
Standby current (inactive period of normal mode) $I_{DDSB}$ 0.290.8μA
Current during humidity measurement $I_{DDH}$ Max value at 85 °C340450μA
Current during pressure measurement $I_{DDP}$ Max value at -40 °C714849μA
Current during temperature measurement $I_{DDT}$ Max value at 85 °C350μA
Start-up time $t_{startup}$ Time to first communication after both $V_{DD} > 1.58$ V and $V_{DDIO} > 0.65$ V2ms
Power supply rejection ratio (DC)PSRRfull $V_{DD}$ range±0.01 ±5%r.H./V Pa/V
Standby time accuracy $\Delta t_{standby}$ ±5±25%

1.2 Gas sensor specification

The tables 2-5 list the gas sensor specification. All the parameters are deduced from lab measurements under controlled environmental conditions, which are chosen according to the ISO16000-29 standard “Test methods for VOC detectors”. The detailed procedure to measure the gas sensor is available in the application notes AN012 (“Measurement Instructions fo Lab Environment”) or AN016 (“handbook”).

Referring to chapter 4, a software solution (BSEC: Bosch Software Environmental Cluster) is available for the BME688. The software is carefully engineered to seamlessly work with the 4 integrated sensors inside the BME688. Based on intelligen algorithms, the BSEC provides numerous useful outputs (see Table 20), e.g. an Index for Air Quality (IAQ), bVOC- & CO - equivalents (ppm) and Gas scan results (%). The IAQ output is an index that can have values between 0 and 500 with a resolution of 1 to indicate or quantify the quality of the air available in the surrounding. Table 3 lists the IAQ system specification. The detailed classification and colour coding of the IAQ index is described in Table 6. Furthermore, the BSEC solution supports different operation modes (see Table 19) for the gas sensor to address the necessary power budget and update rate requirements of the end-application.

Unless mentioned otherwise, the specifications are deduced from new sensors that have been operated for at least five days mainly in ambient air and consequently have the same history (i.e. same power mode and exposed to the same environment).

The sensors are tested especially with hydrogen sulfide (H S), ethanol (“EtOH”), carbon monoxide (CO) and breath-VOCs (“b-VOC”). The b-VOC mixture, as listed in Table 7, represents the most important compounds in an exhaled breath of healthy humans. The values are derived from several publications on breath analysis studies. The composition does not contain species which would chemically react to ensure that the mixture is stable for at least 6 months. Furthermore, the composition is also limited to species which can be manufactured in one mixture.

Table 2: Gas sensor parameter specification

ParameterSymbolConditionMinTypMaxUnit
Operational range1-4085°C
1095% r.H.
Supply Current during heater operation $I_{DD}$ Heater target temperature 320 °C, constant operation ( $V_{DD} \leq 1.8 \text{ V}, 25^{\circ}\text{C}$ )91213mA
Peak Supply Current $I_{Peak}$ occurs within first ms of switching on the hotplate151718mA
Average Supply Current( $V_{DD} \leq 1.8 \text{ V}, 25^{\circ}\text{C}$ ) $I_{DD,IAQ}$ Ultra-low power mode0.09mA
Low power mode0.9mA
Continuous mode12mA
Response time2 (brand-new sensors)τ33-63%Ultra-low power mode92s
τ33-63%Low power mode1.4s
τ33-63%Continuous mode0.75s
Resolution of gas sensor resistance measurement0.050.080.11%
Noise in gas sensor resistance (RMS) $N_R$ 1.5%

Table 3: IAQ system parameter specification3

ParameterSymbolConditionMinTypMaxUnit
$Accuracy\ status^4$ $AX_{IAQ}$ Android compatible03
IAQ Resolution $IAQ_{rs}$ 1
IAQ Range $IAQ_{rg}$ 0500
$Sensor-to-sensor\ deviation^5$ $IAQ_{S2S}$ All operation modes±15% ±15
$Durability\ to\ siloxanes^{6,7,8}$ $IAQ_{S2S}$ Sensor-to-sensor deviation±15% ±15
$IAQ_{drift}$ Drift at low &amp; high concentrations±1% ±4

Table 4: Standard gas scanner mode for H S selectivity9

ParameterSymbolConditionMinTypMaxUnit
Average Supply Current (VDD≤1.8 V, 25°C)IDD,IAQGas scanner standard mode consists of 5 scan cycles and 10 sleeping cycles3.96mA
Gas scanning power consumption in ampere hoursAhscanElectric charge for one scanning phase (5 scan cycles in standard gas scanner mode)0.18mAh
Duty cycle of standard gas scanner modetstandard scanDuration of gas scanning phase54s
fstandard scanODR during scanning phase1/10.81/s
tstandard sleepDuration of sleeping phase108s
fstandard sleepODR during sleeping phase01/s
Gas scan cycletstandard cycleDuration of gas scan cycle10.8s
Selectivity to H2SPH2SProbability of H2S and non H2S class01
Resolution of probability0.01
SH2SSensitivity (recall) of H2S classification0.95
F1H2SF1 score of H2S classification0.94
DS/F1Average long-term drift10of Sensitivity / F1 score0.012/year
IAQIAQrg0500

Table 5: Customization of gas scanner mode11

ParameterSymbolConditionMinTypMaxUnit
ClassificationNumber of Classes24
Number of temperature steps10
Duration of gas scan cycle10 to 30sec

Table 6: Index for Air Quality (IAQ) classification and color-coding12

IAQ IndexAir QualityImpact (long-term exposure)Suggested action
0 – 50ExcellentPure air; best for well-beingNo measures needed
51 – 100GoodNo irritation or impact on well-beingNo measures needed
101 – 150Lightly pollutedReduction of well-being possibleVentilation suggested
151 – 200Moderately pollutedMore significant irritation possibleIncrease ventilation with clean air
201 – 250Heavily pollutedExposition might lead to effects like headache depending on type of VOCsoptimize ventilation
251 – 350Severely pollutedMore severe health issue possible if harmful VOC presentContamination should be identified if level is reached even w/o presence of people; maximize ventilation &amp; reduce attendance
&gt;351Extremely pollutedHeadaches, additional neurotoxic effects possibleContamination needs to be identified; avoid presence in room and maximize ventilation

Table 7: bVOC mixture with Nitrogen as carrier gas

Molar fractionCompoundProduction toleranceCertified accuracy
5 ppmEthane20 %5 %
10 ppmIsoprene /2-methyl-1,3 Butadiene20 %5 %
10 ppmEthanol20 %5 %
50 ppmAcetone20 %5 %
15 ppmCarbon Monoxide10 %2 %

1.3 Humidity sensor specification

Table 8: Humidity parameter specification

ParameterSymbolConditionMinTypMaxUnit
$Operating\ Range^{13}$ -402585°C
0100% r.H.
Full accuracy range065°C
1090% r.H.
Supply Current $I_{DD,H}$ 1 Hz forced mode, temperature and humidity measurement2.12.8μA
Absolute Accuracy $A_H$ 20 - 80 % r.H., 25 °C, including hysteresis±3% r.H.
$Hysteresis^{14}$ $H_H$ 10→90→10 % r.H., 25°C±1.5% r.H.
$Nonlinearity^{15}$ $NL_H$ 10→90 % r.H., 25°C1.7% r.H.
Response time to complete 63% of $step^{16}$ $τ_{0-63\%}$ $N_2(dry) \rightarrow 90\% r.H., 25°C$ 8s
Resolution $R_H$ 0.008% r.H.
Noise in humidity (RMS) $N_H$ Highest oversampling0.01% r.H.
Long-term stability $ΔH_{stab}$ 10 - 90 % r.H., 25°C0.5% r.H./year

1.4 Pressure sensor specification

Table 9: Pressure parameter specification

ParameterSymbolConditionMinTypMaxUnit
Operating temperature range $T_A$ operational-402585°C
full accuracy065
Operating pressure rangePfull accuracy3001100hPa
Supply current $I_{DD,LP}$ 1 Hz forced mode, pressure and temperature, lowest power3.14.2μA
Temperature coefficient of $offset^{17}$ $TCOP$ 25 - 40 °C, 900 hPa±1.3Pa/K
±10.9cm/K
Absolute accuracy pressure $A_p, full$ 300 - 1100 hPa0 - 65°C±0.6hPa
Relative accuracy pressure $A_{rel}$ 700 – 900 hPa,25 - 40 °C, at constant humidity±0.12hPa
$A_{rel}$ 900 – 1100 hPa25 - 40 °C, at constant humidity±0.12hPa
Resolution of pressure output data $R_P$ Highest oversampling0.18Pa
Noise in pressure $N_{P,fullBW}$ Full bandwidth, highest oversampling1.4Pa
11cm
Reduced bandwidth, highest oversampling0.2Pa
1.7cm
Solder driftMinimum solder height 50 μm-0.51.2+2.0hPa
Long-term stability $^{18}$ $P_{stab}$ per year±1.0hPa
Possible sampling rate $f_{sample\_P}$ Lowest oversampling, see chapter 3.6.2157182Hz

1.5 Temperature sensor specification

Table 10: Temperature parameter specification

ParameterSymbolConditionMinTypMaxUnit
Operating temperature range $T_A$ operational-402585°C
Supply current $I_{DD,T}$ 1 Hz forced mode,temperature measurement only1.0μA
Absolute accuracy $temperature^{19}$ $A_T$ 0 - 65 °C±0.5°C
Output resolution $R_T$ API output resolution0.01°C
RMS noise $N_T$ Lowest oversampling0.005°C

2. Absolute maximum ratings

The absolute maximum ratings are determined over the complete temperature range using corner lots. The values are provided in Table 11.

Table 11: Absolute maximum ratings

ParameterConditionMinMaxUnit
Voltage at any supply pin $V_{DD}$ and $V_{DDIO}$ pin-0.34.25V
Voltage at any interface pin-0.3 $V_{DDIO} + 0.3$ V
Storage temperature≤ 65% r.H.-45+85°C
Pressure020 000hPa
ESDHBM, at any pin±2kV
Machine model±200V

3. Sensor usage

3.1 Use cases

The key features of the BME688 hardware-software system are:

Selectivity to target gas classes

Provision for custom usecase develpment

Calculation of index for air quality (IAQ) level outside of the device

Calculation of ambient air temperature outside of the device (e.g. phone)

Calculation of ambient relative humidity outside of the device

3.2 Selectivity

Selectivity to target gas classes will enable wide variety of use cases for customers. From a gas sensing perspective selectivity is the ability to classify different gas compositions (with different combinations and concentrations of gases) that occur in different situations. Operating the metal oxide layer of the gas sensor at different temperatures enable measuring with different sensitivities and can create a unique fingerprint for numerous gas compositions. The standard heater profile is as shown below figure is executed in sensor ASIC which consists of 10 heater temperature steps. Features interpreted by AI based software brings selectivity feature.


Figure 1: Standard Heater profile

3.3 Indoor-air-quality

The BME688 is a metal oxide-based sensor that detects gases by adsorption (and subsequent oxidation/reduction) on its sensitive layer. The intensity of the signal typically scales with the chemical reactivity of the gases. The BME688 reacts to most volatile compounds as well as many other gases polluting indoor air (exceptions are very few gases which are chemically pretty inert, e.g. N and CO ). In contrast to sensors selective for one specific component, the BME688 is capable of measuring the sum of VOCs/contaminants in the surrounding air. This enables the BME688 to detect e.g. outgasing from paint, furniture and/or garbage, high VOC levels due to cooking, food consumption, exhaled breath and/or sweating.

As a raw signal, the BME688 will output the gas sensor resistance values and its changes due to varying VOC concentrations (the higher the concentration of reducing VOCs, the lower the resistance and vice versa). Since this raw signal is influenced by parameters other than VOC concentration (e.g. humidity level), the raw values are transformed to an index for air quality (IAQ) by smart algorithms inside BSEC.

The IAQ scale ranges from 0 (clean air) to 500 (heavily polluted air). During operation, the algorithms automatically calibrate and adapt themselves to the typical environments where the sensor is operated (e.g., home, workplace, inside a car, etc.). This automatic background calibration ensures that users experience consistent IAQ performance. The calibration process considers the recent measurement history (typ. up to four days, configurable) to ensure that IAQ ~ 50 corresponds to “typical good” air and IAQ ~ 200 indicates “typical polluted” air.

3.4 Sensor modes

The sensor supports low-level power modes: sleep, parallel and forced mode. These modes can be selected using the mode<1:0> control register (see Section 5.3.1.3). The key differences between the modes are summarized in Table 12. Measurement cycle is abbreviated as TPHG (Temperature, Pressure, Humidity and Gas) in the following descriptions.

After a power-up sequence, the sensor automatically starts in sleep mode. If the device is currently performing a measurement, execution of mode switching commands is delayed until the end of the currently running measurement period. It is important to note that, further mode change commands or other write commands to the control registers are ignored unti the mode change command has been executed. All control registers should be set to the desired values before writing to the mode register.

Table 12: Low-level operation modes

Operation modemode&lt;1:0&gt;Key features
Sleep00► No measurements are performed ► Minimal power consumption
Forced mode01► Single TPHG cycle is performed ► Sensor automatically returns to sleep mode afterwards ► Gas sensor heater only operates during gas measurement
Parallel mode10► Multiple TPHG cycles are performed ► Sensor will not automatically returns to sleep mode ► Gas sensor heater operates in parallel to TPH measurement

In forced mode, temperature, pressure, humidity and gas conversion are performed sequentially for 1 heater temperature step and heating duration. In parallel mode, TPH measurements and gas conversion are performed parallelly. Hence in parallel mode at least one of T,P,H is expected to be enabled. Up to 10 temperature steps and heating durations for the gas sensor hot plate can be stored in the sensor registers and can be executed as heater profile. Heater profiles can be repeated without host support. In the Figure 1, heater steps and the corresponding measurements are identified as G0 – G9.

Figure 2 illustrates the handling of these measurement sequences and the gas sensor hot plate is heated for the forced mode and parallel mode.


Figure 2: Sequence of ADC and gas sensor heater operation

3.5 Sensor configuration

Quick start – Forced mode

The sensor is configured by writing to a set of control registers (see Chapter 5 for a detailed list of all available registers and their descriptions). This section illustrates, with the help of a basic step-by-step example, how to configure the sensor fo simple forced mode measurements with a single heater step. For a more detailed description of the measurement flow, please refer to Section 3.6.

In this example, the sensor will be configured to use 2x oversampling for its temperature measurements, 16x oversampling for the pressure signal, and 1x oversampling for humidity. Moreover, the gas sensor hot plate will be configured to be heated for 100 ms at 300 °C before the gas measurement is performed.

First, the user must configure the oversampling settings for temperature, pressure and humidity by setting the contro registers osrs_t<2:0> and osrs_h<2:0>, respectively. Supported settings range from 16x oversampling down to 0x, which is equivalent to skipping the corresponding sub-measurement. See Section 5.3.3 for further details.

  1. Set humidity oversampling to 1x by writing 0b001 to osrs_ $h { < } 2 { : } 0 { > }$

  2. Set temperature oversampling to 2x by writing 0b010 to osrs $\cdot t { < } 2 { : } 0 >$

  3. Set pressure oversampling to 16x by writing 0b101 to osrs $\ J { < } 2 { : } 0 { > }$

It is highly recommended to set first osrs_h<2:0> followed by osrs_t<2:0> and osrs $\ J { < } 2 { : } 0 { > }$ in one write command (see Section 3.6).

Next, the user shall set at least one gas sensor hot plate temperature step and heating duration. Up to 10 heating duration can be configured through the control registers gas_wait $. x { < } 7 { : } 0 >$ , where x ranges from 0 to 9. See Section 5.3.4 for definition of register content. The corresponding heater step are stored in the registers res_heat_x<7:0>. Section 3.6.5 explains how to convert the target heater temperature, $\mathsf { e . g . 3 0 0 ^ { \circ } C } .$ , into a register code. For forced mode operation, the used heater step is selected by setting the control register nb_conv<3:0> to the heater profile to be used, e.g. to use gas_wait $. 0 { < } 7 { : } 0 >$ and res_heat_0<7:0>, nb_conv<3:0> shall be set to 0x0. Finally, gas functionality shall be enabled by setting the $r u n _ g a s _ h$ bit to 1.

  1. Set gas_wait_0<7:0> to 0x59 to select 100 ms heat up duration

  2. Set the corresponding heater step by writing the target heater resistance to res_heat_0<7:0>

  3. Set nb_conv<3:0> to 0x0 to select the previously defined heater settings

  4. Set $r u n _ g a s _ h$ to 1 to enable gas measurements

Now, a single forced mode measurement with the above settings can be triggered by writing 0b01 to mode<1:0>. For more details on data readout, please see Section 5.3.1.3.

  1. Set mode<1:0> to 0b01 to trigger a single measurement.

Please find abstracted example code using BME68x-Sensor-API in https://github.com/BoschSensortec/BME68x-Sensor API/blob/master/examples/forced_mode/forced_mode.c

Sensor configuration flow – Forced mode

Figure 3 illustrates which control registers must be set. For details on the individual control registers, please refer to Chapter 5. Moreover, details on the measurement flow for the individual modes can be found in Section 3.6.


Figure 3: Sensor configuration flow in Forced Mode

Quick start – Parallel mode

Please find abstracted example code using BME68x-Sensor-API in https://github.com/BoschSensortec/BME68x-Sensor-API/tree/master/examples/parallel\_mode

Sensor configuration flow – Parallel mode

Figure 3 illustrates which control registers must be set. For details on the individual control registers, please refer to Chapter 5. Moreover, details on the measurement flow for the individual modes can be found in Section 3.6.


Figure 4: Sensor configuration flow in Parallel Mode


Figure 5: Illustration of parallel measurement mode, an example with 3 step heater profile

3.6 Measurement flow

Referring to Figure 2, the BME688 measurement period consists of a temperature, pressure and humidity measurement with selectable oversampling. Moreover, it contains a heating phase for the gas sensor hot plate as well as a measurement of the gas sensor resistance. In parallel mode there are 3 data registers naming Field 0, Field 1 and Field 2 which will be filled in first in first out order.

After the measurement period, the pressure and temperature data can be passed through an optional IIR filter, which removes short-term fluctuations. For humidity and gas, such a filter is not needed and has not been implemented.

Temperature measurement

Temperature measurement can be enabled or skipped. Skipping the measurement is typically not recommended since temperature information is used to compensate temperature influences in the other parameters. When enabled, several oversampling options exist. The temperature measurement is controlled by the osrs_t<2:0> setting which is detailed in Section 5.3.3.2. For the temperature measurement, oversampling is possible to reduce the noise. The resolution of the temperature data depends on the IIR filter (see Section 5.3.3.4) and the oversampling setting:

When the IIR filter is enabled, the temperature resolution is 20 bit

When the IIR filter is disabled, the temperature resolution is 16 + (osrs_t – 1) bit, e.g. 18 bit when osrs_t is set to ‘3’

Using the variables listed in Table 13, the following code will calculate the compensated temperature value (in degrees Celsius). It is, however, recommended to use the sensor API available on github (Chapter 0) for a friendlier user experience.

Floating point:

var1 = (((double)temp_adc / 16384.0) - ((double)par_t1 / 1024.0)) * (double)par_t2;
var2 = (((double)temp_adc / 131072.0) - ((double)par_t1 / 8192.0)) *
    (((double)temp_adc / 131072.0) - ((double)par_t1 / 8192.0))) *
    ((double)par_t3 * 16.0);
t_fine = var1 + var2;
temp_comp = t_fine / 5120.0;

Integer:

var1 = ((int32_t)temp_adc >> 3) - ((int32_t)par_t1 << 1);
var2 = (var1 * (int32_t)par_t2) >> 11;
var3 = (((var1 >> 1) * (var1 >> 1)) >> 12) * ((int32_t)par_t3 << 4)) >> 14;
t_fine = var2 + var3;
temp_comp = ((t_fine * 5) + 128) >> 8;

where

par_t1, par_t2 and par_t3 are calibration parameters,

temp_adc is the raw temperature output data, see 5.3.5.2

temp_comp is the compensated temperature output data in degrees Celsius.

Table 13: Variable names and register addresses for temp_comp calculation

Variable nameRegister address (LSB / MSB)
par_t10xE9 / 0xEA
par_t20x8A / 0x8B
par_t30x8C
temp_adcField 0 - 0x24&lt;7:4&gt; / 0x23 / 0x22Field 1 - 0x35&lt;7:4&gt; / 0x34 / 0x33Field 2 - 0x46&lt;7:4&gt; / 0x45 / 0x44

Pressure measurement

Pressure measurement can be enabled or skipped. When enabled, several oversampling options exist. The pressure measurement is controlled by the osrs_p<2:0> setting which is detailed in Section 5.3.3. For the pressure measurement, oversampling is possible to reduce noise. The resolution of the pressure data depends on the IIR filter (see Section 5.3.3.4) and the oversampling setting:

When the IIR filter is enabled, the pressure resolution is 20 bit

When the IIR filter is disabled, the pressure resolution is $1 6 + ( o s r s _ p - 1 )$ bit, e.g. 18 bit when osrs_p is set to $\mathfrak { s }$

Using the variables listed in Table 14 the following code will calculate the compensated pressure value (in Pascal). It is, however, recommended to use the sensor API available on github for a friendlier user experience.

Floating point:
var1 = ((double)t_fine / 2.0) - 64000.0;
var2 = var1 * var1 * ((double)par_p6 / 131072.0);
var2 = var2 + (var1 * (double)par_p5 * 2.0);
var2 = (var2 / 4.0) + ((double)par_p4 * 65536.0);
var1 = (((double)par_p3 * var1_p * var1) / 16384.0) +
((double)par_p2 * var1_p)) / 524288.0;
var1 = (1.0 + (var1 / 32768.0)) * (double)par_p1;
press_comp = 1048576.0 - (double)press_adc;
press_comp = ((press_comp - (var2_p / 4096.0)) * 6250.0) / var1;
var1 = ((double)par_p9 * press_comp * press_comp) / 2147483648.0;
var2 = press_comp * ((double)par_p8 / 32768.0);
var3 = (press_comp / 256.0) * (press_comp / 256.0) *
(press_comp / 256.0) * (par_p10 / 131072.0);
press_comp = press_comp + (var1_p + var2_p + var3_p +
((double)par_p7 * 128.0)) / 16.0;

Integer:
var1 = ((int32_t)t_fine >> 1) - 64000;
var2 = (((var1 >> 2) * (var1 >> 2)) >> 11) * (int32_t)par_p6) >> 2;
var2 = var2 + ((var1 * (int32_t)par_p5) << 1);
var2 = (var2 >> 2) + ((int32_t)par_p4 << 16);
var1 = (((((var1 >> 2) * (var1 >> 2)) >> 13) *
((int32_t)par_p3 << 5)) >> 3) + (((int32_t)par_p2 * var1) >> 1);

var1 = var1 >> 18;
var1 = ((32768 + var1) * (int32_t)par_p1) >> 15;
press_comp = 1048576 - press_raw;
press_comp = (uint32_t)((press_comp - (var2 >> 12)) * ((uint32_t)3125));
if (press_comp >= (1 << 30))
    press_comp = ((press_comp / (uint32_t)var1) << 1);
else
    press_comp = ((press_comp << 1) / (uint32_t)var1);
var1 = ((int32_t)par_p9 * (int32_t)((press_comp >> 3) *
(press_comp >> 3)) >> 13)) >> 12;
var2 = ((int32_t)(press_comp >> 2) * (int32_t)par_p8) >> 13;
var3 = ((int32_t)(press_comp >> 8) * (int32_t)(press_comp >> 8) *
(int32_t)(press_comp >> 8) * (int32_t)par_p10) >> 17;
press_comp = (int32_t)(press_comp) +
((var1 + var2 + var3 + ((int32_t)par_p7 << 7)) >> 4);

where

▶ par_p1, par_p2, ..., par_p10 are calibration parameters,
▶ press_adc is the raw pressure output data, see 5.3.5.1
▶ press_comp is the compensated pressure output data in Pascal.

Table 14: Variable names and register addresses for press_comp calculation

Variable nameRegister address (LSB / MSB)
par_p10x8E / 0x8F
par_p20x90 / 0x91
par_p30x92
par_p40x94 / 0x95
par_p50x96 / 0x97
par_p60x99
par_p70x98
par_p80x9C / 0x9D
par_p90x9E / 0x9F
par_p100xA0
press_adcField 0 - 0x21&lt;7:4&gt; / 0x20 / 0x1FField 1 - 0x32&lt;7:4&gt; / 0x31 / 0x30Field 2 - 0x43&lt;7:4&gt; / 0x42 / 0x41

Humidity measurement

The humidity measurement can be enabled or skipped. When enabled, several oversampling options exist. The humidity measurement is controlled by the osrs_h<2:0> setting, which is described in detail in Section 5.3.3.1. For the humidity measurement, oversampling is possible to reduce noise. The resolution of the humidity measurement is fixed at 16 bit ADC output.

Using the variables listed in Table 15, the following code will calculate the compensated humidity value (in percent). It is, however, recommended to use the sensor API available on github for a friendlier user experience.

Floating point:
var1 = hum_adc - (((double)par_h1 * 16.0) + (((double)par_h3 / 2.0) * temp_comp));
var2 = var1 * (((double)par_h2 / 262144.0) * (1.0 + (((double)par_h4 / 16384.0) * temp_comp) + (((double)par_h5 / 1048576.0) * temp_comp * temp_comp));
var3 = (double)par_h6 / 16384.0;
var4 = (double)par_h7 / 2097152.0;
hum_comp = var2 + ((var3 + (var4 * temp_comp)) * var2 * var2);
temp_scaled = (int32_t)temp_comp;
var1 = (int32_t)hum_adc - (int32_t)((int32_t)par_h1 << 4) -
    (((temp_scaled * (int32_t)par_h3) / ((int32_t)100)) >> 1);
var2 = ((int32_t)par_h2 * (((temp_scaled *
    (int32_t)par_h4) / ((int32_t)100)) +
    (((temp_scaled * ((temp_scaled * (int32_t)par_h5) /
    ((int32_t)100))) >> 6) / ((int32_t)100)) + ((int32_t)(1 << 14)))) >> 10;

var3 = var1 * var2;

var4 = (((int32_t)par_h6 << 7) +

$$
((t e m p _ s c a l e d * (i n t 3 2 _ t) p a r _ h 7) / ((i n t 3 2 _ t) 1 0 0))) > > 4;
$$

var5 = ((var3 >> 14) * (var3 >> 14)) >> 10;

var6 = (var4 * var5) >> 1;

hum_comp = (var3 + var6) >> 12;

hum_comp = (((var3 + var6) >> 10) * ((int32_t) 1000)) >> 12;

where

par_h1, par_h2, …, par_h7 are calibration parameters,

hum_adc is the raw humidity output data, see 5.3.5.3

hum_comp is the compensated humidity output data in percent.

Table 15: Variable names and register addresses for hum_comp calculation

Variable nameRegister address (LSB / MSB)
par_h10xE2&lt;3:0&gt; / 0xE3
par_h20xE2&lt;7:4&gt; / 0xE1
par_h30xE4
par_h40xE5
par_h50xE6
par_h60xE7
par_h70xE8
hum_adcField 0 - 0x26 / 0x25Field 1 - 0x37 / 0x36Field 2 - 0x48 / 0x47

IIR filter

The environmental pressure is subject to many short-term changes, caused external disturbances. To suppress disturbances (e.g. slamming of door or wind blowing into the sensor) in the output data without causing additional interface traffic and processor work load, the BME688 features an internal IIR filter (see Section 5.3.3.4). It effectively reduces the bandwidth o the temperature and pressure output signals and increases the resolution of the output data to 20 bit, noting that the humidity and gas values inside the sensor does not fluctuate rapidly and does not require low pass filtering. The output of a next measurement step is filtered using the following formula:

$$
x _ {f i l t} [ n ] = \frac {x _ {f i l t} [ n - 1 ] \cdot (c - 1) + x _ {A D C}}{c}
$$

�����[� − 1] is the data coming from the current filter memory, and $x _ { A D C }$ is the data coming from current ADC acquisition. � [�] denotes the new value of filter memory and the value that will be sent to the output registers.

The IIR filter can be configured to different filter coefficients, which slows down the response to the sensor inputs. Note that the response time with enabled IIR filter depends on the number of samples generated, which means that the data output rate must be known to calculate the actual response time.

When writing to the register filter, the filter is reset. The next ADC values will pass through the filter unchanged and become the initial memory values for the filter. If temperature or pressure measurements are skipped, the corresponding filter memory will be kept unchanged even though the output registers are set to 0x80000. When the previously skipped measurement is re-enabled, the output will be filtered using the filter memory from the last time when the measurement was not skipped. If this is not desired, please write to the filter register in order to re-initialize the filter.

Gas sensor heating and measurement

The operation of the gas sensing part of BME688 involves two steps:

  1. Heating the gas sensor hot plate to a target temperature (typically between 200 °C and 400 °C) and keep that temperature for a certain duration of time.

  2. Measuring the resistance of the gas sensitive layer.

Up to 10 different hot plate temperature set points can be configured by setting the registers res heat x<7:0>. where x = 0…9 .The internal heater control loop operates on the resistance of the heater structure. Hence, the user first needs to convert the target temperature into a device specific target resistance before writing the resulting register code into the sensor memory map.

Using the variables listed in Table 16, the following code will calculate register code that to be written to res_heat_x<7:0>. It is, however, recommended to use the sensor API available on github (Chapter 0) for a friendlier user experience.

Floating point:

var1 = ((double)par_g1 / 16.0) + 49.0;
var2 = (((double)par_g2 / 32768.0) * 0.0005) + 0.00235;
var3 = (double)par_g3 / 1024.0;
var4 = var1 * (1.0 + (var2 * (double) target_temp));
var5 = var4 + (var3 * (double)amb_temp);
res_heat_x = (uint8_t)(3.4 * ((var5 * (4.0 / (4.0 + (double)res_heat_range)) * (1.0/(1.0 + ((double)res_heat_val * 0.002)))) - 25));

Integer:

var1 = (((int32_t)amb_temp * par_g3) / 10) << 8;
var2 = (par_g1 + 784) * (((par_g2 + 154009) * target_temp * 5) / 100) + 3276800) / 10);
var3 = var1 + (var2 >> 1);
var4 = (var3 / (res_heat_range + 4));
var5 = (131 * res_heat_val) + 65536;
res_heat_x100 = (int32_t)((var4 / var5) - 250) * 34);
res_heat_x = (uint8_t)((res_heat_x100 + 50) / 100);

where

par_g1, par_g2, and par_g3 are calibration parameters,

target_temp is the target heater temperature in degree Celsius,

amb_temp is the ambient temperature (hardcoded or read from temperature sensor),

var5 is the target heater resistance in Ohm,

res_heat_x is the decimal value that needs to be stored in register, where ‘x’ corresponds to the temperature profile number between 0 and 9,

res_heat_range is the heater range stored in register address 0x02 <5:4>, and res_heat_val is the heater resistance correction factor stored in register address 0x00 (signed, value from -128 to 127).

Floating point:
uint32_t var1 = UINT32_C(262144) >> gas_range;
int32_t var2 = (int32_t) gas_adc - INT32_C(512);
var2 *= INT32_C(3);
var2 = INT32_C(4096) + var2;
gas_res = 1000000.0f * (float)var1 / (float)var2;

Table 16: Variable names and register addresses for res_heat_x calculation

Variable nameRegister address (LSB / MSB)
par_g10xED
par_g20xEB/0xEC
par_g30xEE
res_heat_range0x02 &lt;5:4&gt;
res_heat_val0x00

For each of the 10 temperature steps, the heating duration must be specified. Referring to Figure 2, the heating phase starts after the temperature, pressure and humidity measurements are complete. This means there is no heating in parallel to these measurements, which is desirable to minimize undesired cross-influences between the various sensor components.

The heating duration is specified by writing to the corresponding gas_wait_x<7:0> control register. Heating durations between 1 ms and 4032 ms can be configured. In practice, approximately 20–30 ms are necessary for the heater to reach the intended target temperature.

3.7 Data readout

The procedure goes as follows, the new_data bit (see Section 5.3.6.1) can be checked to see if a new data is generated. I gas measurements are performed the gas_valid_r (see Section 5.3.6.5) and heat_stab_r (see Section 5.3.6.6) status bits of the respectively field should be checked to ensure that the gas measurement was successful. If heat_stab_r is zero, it indicates that either the heating time was not enough to allow the sensor to reach to configured target temperature or tha the target temperature was too high for the sensor to reach.

After the uncompensated values of temperature, pressure and humidity have been read, the actual humidity, pressure and temperature need to be calculated using the compensation parameters stored in the device. Please refer to the BME68x-Sensor-API for more details.

Gas resistance readout

Readout of gas resistance ADC value and calculation of gas resistance consists of 2 steps

  1. Read gas ADC value (gas_adc) and gas ADC range (gas_range) (see Section 5.3.5)

  2. Convert ADC value into gas resistance in ohm

Using the variables listed in Table 17, the conversion is done as follows:

calc_gas_res = (UINT32_C(10000) * var1) / (uint32_t)var2;

gas_res = calc_gas_res * 100;

where

gas_adc is the raw gas resistance output data (i.e. ADC value), see 0

gas_range is the ADC range of the measured gas resistance, see 5.3.5.5

gas_res is the compensated gas resistance output data in Ohms.

Table 17: Variable names and register addresses for gas_res calculation

Variable nameRegister address (LSB / MSB)
gas_adcField 0 - 0x2D&lt;7:6&gt; / 0x2CField 1 - 0x3E&lt;7:6&gt; / 0x3DField 2 - 0x4F&lt;7:6&gt; / 0x4E
gas_rangeField 0 - 0x2D&lt;3:0&gt;Field 1 - 0x3E&lt;3:0&gt;Field 2 - 0x4F&lt;3:0&gt;

4. Software

4.1 BME software components

Table 18: Software components

Software componentTypeFunctionLink
BME68x sensor APIC codeProvide software interfaces to get compensated raw data from sensor via SPI/I2C interfaceBME68x-Sensor-API
BSECC static libraryProvides fused sensor outputs and AI interpreter for classification of gas classesBME688-Software
BME AI StudioPC applicationAI toolchain to develop, verify and deploy custom gas classification use cases

4.2 BME software library - BSEC software

BME688 sensor is intended to be used together with Bosch Software Environmental Cluster (BSEC) solution and BME6xy sensor API to unlock its full potential. The BSEC software features intelligent algorithms which enable use cases such as indoor-air-quality monitoring using the BME688. Moreover, the software algorithms handle humidity compensation, baseline as well as long-term drift correction of the gas sensor signal.

Bosch Sensortec BSEC software is available as a closed source binary which will be made available via a Software License Agreement (SLA) on the Bosch Sensortec website.

Different power modes for the gas sensor and corresponding data rates are supported by the software solution:

 Gas Scan mode (scan) is designed for interactive applications where selectivity of traget gases are needed in addition in indoor airquality monitoring. The standard heater profile has an update rate of 10.8 s and can be finetuned for use-cases using BME AI Studio.

Ultra low power (ULP) mode is designed for battery-powered and/or frequency-coupled devices over extended periods of time. This mode features an update rate of 300 seconds and an average current consumption of <0.1 mA Quick Ultra-low power (q-ULP) has a 3 s data rate for Temprature, pressure and humidity w/o significantly increasing the power consumption compared to ULP.

Low power (LP) mode that is designed for interactive applications where the air quality is tracked and observed at a higher update rate of 3 seconds with a current consumption of <1 mA

Continuous (CONT) mode provides an update rate of 1 Hz and shall only be used short-term for use cases that incorporate very fast events or stimulus.

Table 19: BSEC gas sensor power-modes

BSEC power modeUpdate rateAverage current consumption
Standard gas scan mode (scan)1/10.8 s3.96 mA
Ultra-low power mode (ULP)3.3 mHz0.09 mA
quick Ultra-low power mode (q-ULP)0.33 Hz (T, p, h) / 3.3 mHz (IAQ)0.1 mA
Low power mode (LP)0.33 Hz0.9 mA
Continuous mode (for testing purposes only)1 Hz12 mA

The following table describes the available outputs of BSEC. Full descriptions of the outputs and the available interfaces are available in the integration guide shipped together with the BSEC software.

Table 20: BSEC outputs

OutputDescription
Raw pressureRaw data from sensor API bypassed to BSEC output
Raw temperatureRaw data from sensor API bypassed to BSEC output
Raw relative humidityRaw data from sensor API bypassed to BSEC output
Raw gas resistanceRaw data from sensor API bypassed to BSEC output
Sensor-compensated temperature (°C)Temperature which is compensated for internal cross-influences caused by the BME sensor
Sensor-compensated relative humidity (%)Relative humidity which is compensated for internal cross-influences caused by the BME sensor
Sensor-compensated gas resistance (Ohm)Raw gas resistance compensated by temperature and humidity influences.
Ambient temperature (°C)Ambient temperature after compensating the influence of device (where BME688 is integrated in) heatsources
Ambient relative humidity (%)Ambient relative humidity after compensating influence of device (where BME688 is integrated in) heatsources
IAQ (0-500)Index for Air Quality, especially recommended for mobile devices, since the auto-trim algorithm automatically adopts to different environments.
Static IAQ (“s-IAQ”)“Static” Index for Air Quality, especially recommended for stationary devices (w/o auto-trimming algorithm)
CO2 equivalents (ppm)Estimation of the CO2 level in ppm. The sensor does not directly measure CO2, but derives this from the average correlation between VOCs and CO2 in human&#x27;s exhaled breath.
b-VOC equivalents (ppm)Conversion into breath-VOC equivalents in ppm concentration. The scaling is derived from lab tests with the b-VOC gas mixture described in Table 7.
Accuracy status (0-3)Accuracy status of IAQ
Stabilization time statusIndicates if the sensor is undergoing initial stabilization during its first use after production
Run in statusIndicates when the sensor is ready after after switch-on
Gas (%)Alternative indicator for air pollution which rates the current raw gas resistance value based on the individual sensor history: 0% = “lowest air pollution ever measured” 100% = “highest air pollution level ever measured”
Gas scan result (%)The gas scan result is given in % for each of the used classes. In standard scan mode, the probability of H2S and non H2S class is provided by the variables GAS_ESTIMATE_1 &amp; GAS_ESTIMATE_2 respectively. A maximum of 4 classes can be used by configuring using BME AI-Studio.

5. Global memory map and register description

5.1 General remarks

Communication with the device is performed by reading from and writing to registers. Registers have a width of 8 bits. If I2C is used, 8-bit addressing is utilized. If SPI is used, 7-bit address is only available for register access. For details on the interface, consult Chapter 0.

In SPI mode complete memory map is accessed using page 0 and page 1. Register spi_mem_page is used for page selection. After power-on, spi_mem_page is in its reset state and page 0 (0x80 to 0xFF) will be active. Page 1 (0x00 to 0x7F) will be active on setting spi_mem_page to 1.

Global memory map consists of calibration registers, control registers, data registers, status registers and reserved registers. There are, however, several registers which are reserved. Accordingly, they should not be written to and no specific value is guaranteed when they are read.

Table 21: Memory map page selection

Digital InterfaceRegister address rangeRegister spi_mem_pageMemory Page
I2C0x00 to 0xFFNot ApplicableNot Applicable
SPI0x80 to 0xFF0 (default; power on state)Page 0
SPI0x00 to 0x7F1Page 1

5.2 Memory map

The memory map is given in Table 22, noting that not all reserved registers are depicted.

Table 22: Memory map

Register nameI2CSPIBit 7Bit 6Bit 5Bit 4Bit 3Bit2Bit 1Bit 0Reset state
AdrAdrPg
Status73h73h1spi_mem_page01h
Variant_idF0h70h0variant_id&lt;7:0&gt;01h
ResetE0h60h0reset&lt;7:0&gt;00h
Chip_idD0h50h0chip_id&lt;7:0&gt;61h
Config75h75h1filter&lt;2:0&gt;spi_3w_en00h
Ctrl_meas74h74h1osrs_t&lt;2:0&gt;osrs_p&lt;2:0&gt;mode&lt;1:0&gt;00h
Ctrl_hum72h72h1spi_3w_int_enosrs_h&lt;2:0&gt;00h
Ctrl_gas_171h71h1run_gasnb_conv&lt;3:0&gt;00h
Ctrl_gas_070h70h1heat_off00h
Gas_wait_shared6Eh6Eh1gas_wait_shared&lt;7:0&gt;00h
Gas_wait_x6Dh...64h6Dh...64h1gas_wait_9&lt;7:0&gt; downto gas_wait_0&lt;7:0&gt;00h
Res_heat_x63h...5Ah63h...5Ah1res_heat_9&lt;7:0&gt; downto res_heat_0&lt;7:0&gt;00h
Idac_heat_x59h...50h59h...50h1idac_heat_9&lt;7:0&gt; downto idac_heat_0&lt;7:0&gt;00h
gas_r_lsb [2]4Fh4Fh1gas_r&lt;1:0&gt;gas_valid_rheat_stab_rgas_range_r00h
gas_r_msb [2]4Eh4Eh1gas_r&lt;9:2&gt;00h
hum_lsb [2]48h48h1hum_lsb&lt;7:0&gt;00h
hum_msb [2]47h47h1hum_msb&lt;7:0&gt;80h
temp_xlsb [2]46h46h1temp_xlsb&lt;7:4&gt;000000h
temp_lsb [2]45h45h1temp_lsb&lt;7:0&gt;00h
temp_msb [2]44h44h1temp_msb&lt;7:0&gt;80h
press_xlsb [2]43h43h1press_xlsb&lt;7:4&gt;000000h
press_lsb [2]42h42h1press_lsb&lt;7:0&gt;00h
press_msb [2]41h41h1press_msb&lt;7:0&gt;80h
sub_meas_index [2]40h40h1sub_meas_index_2&lt;7:0&gt;00h
meas_status [2]3Fh3Fh1new_datagas_measuringmeasuringgas_meas_index_2&lt;3:0&gt;00h
gas_r_lsb [1]3Eh3Eh1gas_r&lt;1:0&gt;gas_valid_rheat_stab_rgas_range_r00h
gas_r_msb [1]3Dh3Dh1gas_r&lt;9:2&gt;00h

hum_lsb [1] 37h 37h 1 hum_lsb<7:0> 00h
hum_msb [1] 36h 36h 1 hum_msb<7:0> 80h
temp_xlsb [1] 35h 35h 1 temp_xlsb<7:4> 0 0 0 0 00h
temp_lsb [1] 34h 34h 1 temp_lsb<7:0> 00h
temp_msb [1] 33h 33h 1 temp_msb<7:0> 80h
press_xlsb [1] 32h 32h 1 press_xlsb<7:4> 0 0 0 0 00h
press_lsb [1] 31h 31h 1 press_lsb<7:0> 00h
press_msb [1] 30h 30h 1 press_msb<7:0> 80h
sub_meas_index [1] 2Fh 2Fh 1 sub_meas_index_1<7:0> 00h
meas_status [1] 2Eh 2Eh 1 new_data gas_measuring measuring gas_meas_index_1<3:0> 00h
gas_r_lsb [2] 2Dh 2Dh 1 gas_r<1:0> gas_valid_r heat_stab_r gas_range_r 00h
gas_r_msb [0] 2Ch 2Ch 1 gas_r<9:2> 00h
hum_lsb [0] 26h 26h 1 hum_lsb<7:0> 00h
hum_msb [0] 25h 25h 1 hum_msb<7:0> 80h
temp_xlsb [0] 24h 24h 1 temp_xlsb<7:4> 0 0 0 0 00h
temp_lsb [0] 23h 23h 1 temp_lsb<7:0> 00h
temp_msb [0] 22h 22h 1 temp_msb<7:0> 80h
press_xlsb [0] 21h 21h 1 press_xlsb<7:4> 0 0 0 0 00h
press_lsb [0] 20h 20h 1 press_lsb<7:0> 00h
press_msb [0] 1Fh 1Fh 1 press_msb<7:0> 80h
sub_meas_index [0] 1Eh 1Eh 1 sub_meas_index_0<7:0> 00h
meas_status [0] 1Dh 1Dh 1 new_data gas_measuring measuring gas_meas_index_0<3:0> 00h

RegistersColor/Type
ReservedDo not change
Status registerRead only
Data registerRead only
Control registerRead/write

5.3 Register description

General control registers

5.3.1.1 SPI 3 wire interrupt enable – spi_3w_int_en

Register NameAddressContentDescription
ctrl_hum0x72spi_3w_int_en &lt;6&gt;New data interrupt can be enabled if the device is in SPI 3 wire mode and pi_3w_int_en=1.The new data interrupt is then indicated on the SDO pad.

5.3.1.2 SPI 3 wire enable – spi_3w_en

Register NameAddressContentDescription
config0x75spi_3w_en&lt;0&gt;Enable SPI 3 wire mode

5.3.1.3 Mode Selection – mode

The operation modes of the sensor can be controlled by the register mode as specified below.

Register NameAddressContentDescription
ctrl_meas0x74mode&lt;1:0&gt;Select sensor power mode as shown in the following table
mode&lt;1:0&gt;Mode
00Sleep mode
01Forced mode
10Parallel mode

5.3.1.4 SPI memory map page selection – spi_mem_page

In SPI mode complete memory page is accessed using page 0 & page 1. Register spi_mem_page is used for page selection. After power-on, spi_mem_page is in its reset state and page 0(0x00 to 0x7F) will be active. Page1 (0x7F to 0xFF) will be active on setting spi_mem_page. Please refer Table 21 for better understanding.

Register NameAddressContentDescription
status0x73(Page 0/1)spi_mem_page &lt;4&gt;Selects memory map page in SPI mode

5.3.1.5 Reset – reset

Writing 0xB6 to this register initiates a soft-reset procedure, which has the same effect like power-on reset. The default value stored in this register is 0x00.

Register NameAddressContentDescription
reset0x60 (Page 0 in SPI mode)0xE0 in I2Creset&lt;7:0&gt;Resets the device

Sensor identification registers

5.3.2.1 Variant Id – Variant_Id

Register NameAddressContentDescription
Variant_Id0x70(Page 0 in SPI mode)0xF0 in I2Cvariant_id&lt;7:0&gt;Variant Id of the sensorFor BME688 - 0x01h

5.3.2.2 Chip id – chip_id

Register NameAddressContentDescription
Chip_Id0x50(Page 0 in SPI mode) 0xD0 in I²Cchip_id&lt;7:0&gt;Chip id of the device

Temperature, pressure and relative humidity control registers

5.3.3.1 Humidity sensor over sampling control – osrs_h

Register NameAddressContentDescription
ctrl_hum0x72osrs_h&lt;2:0&gt;Controls over sampling setting of humidity sensor as described in the following table
osrs_h&lt;2:0&gt;Humidity oversampling
000Skipped (output set to 0x8000)
001oversampling ×1
010oversampling ×2
011oversampling ×4
100oversampling ×8
101, Othersoversampling ×16

5.3.3.2 Over sampling setting – Temperature data – osrs_t

Register NameAddressContentDescription
ctrl_meas0x74osrs_t&lt;7:5&gt;Temperature oversampling settings as shown in the following table
osrs_t&lt;2:0&gt;Temperature oversampling
000Skipped (output set to 0x8000)
001oversampling ×1
010oversampling ×2
011oversampling ×4
100oversampling ×8
101, Othersoversampling ×16

5.3.3.3 Over sampling setting – Pressure data – osrs_p

Register NameAddressContentDescription
ctrl_meas0x74osrs_p&lt;4:2&gt;Pressure oversampling settings as shown in the following table
osrs_p&lt;2:0&gt;Pressure oversampling
000Skipped (output set to 0x8000)
001oversampling ×1
010oversampling ×2
011oversampling ×4
100oversampling ×8
101, Othersoversampling ×16

5.3.3.4 IIR filter control – filter

IIR filter applies to temperature and pressure data but not to humidity and gas data. The data coming from the ADC are filtered and then loaded into the data registers. The temperature and pressure result registers are updated together at the same time at the end of the measurement. IIR filter output resolution is 20 bits. The result registers are reset to value 0x80000 when the temperature and/or pressure measurements have been skipped (osrs_x=”000‟). The appropriate filter memory is kept unchanged (the value from the last measurement is kept). When the appropriate OSRS register is set back to nonzero, then the first value stored to the result registers are filtered.

Register NameAddressContentDescription
config0x75filter&lt;4:2&gt;IIR filter settings as shown in the following table
filter&lt;2:0&gt;Filter coefficient
0000
0011
0103
0117
10015
10131
11063
111127

Gas control registers

The sensor can have 10 programmable gas sensor heater steps. Each heater step consists of a target heater resistance corresponding to heater temperature, heater-on time and optionally an initial heater current.

5.3.4.1 Heater current - idac_heat_x

BME688 contains a heater control block that will inject enough current into the heater resistance to achieve the requested heater temperature. There is a control loop which periodically measures heater resistance value and adapts the value of current injected from a DAC.

The heater operation could be speeded up by setting an initial heater current for a target heater temperature by using register idac_heat_x<7:0>. This step is optional since the control loop will find the current after a few iterations anyway. The current injected to the heater in mA can be calculated by: (idac_heat_7_1 + 1) / 8, where idac_heat_7_1 is the decimal value stored in idac_heat<7:1> (unsigned, value from 0 to 127).

Heater stepsRegister nameAddressContentDescription
0...9idac_heat_xx is from 0 to 90x50...0x59idac_heat_x&lt;7:0&gt;x is from 0 to 9idac_heat of particular heater set point

5.3.4.2 Target heater resistance - res_heat_x

Target heater resistance is programmed by user through res_heat_x<7:0> registers. The definition of res_heat_x is given in Section 3.6.5.

Heater stepRegister nameAddressContentDescription
0...9res_wait_xx is from 0 to 90x5A...0x63res_heat_x&lt;7:0&gt;x is from 0 to 9Decimal value that needs to be stored for achieving target heater resistance

5.3.4.3 Gas Sensor heater-on time in Forced mode - gas_wait_x

Referring to Figure 2, the time between the beginning of the heat phase and the start of gas sensor resistance measurement depends on gas_wait_x setting as mentioned below.

Heater stepRegister nameAddressContentDescription
0...9gas_wait_xx is from 0 to 90x64...0x6Dgas_wait_x&lt;5:0&gt;x is from 0 to 964 timer values with1 ms step sizes, all zeros means no wait
0...9gas_wait_xx is from 0 to 90x64...0x6Dgas_wait_x&lt;7:6&gt;x is from 0 to 9Timer multiplication factor as shown in below table
gas_wait_x&lt;7:6&gt;Gas sensor wait time multiplication factor
001
014
1016
1164

5.3.4.4 Gas Sensor heater-on time in parallel mode -- gas_wait_x & gas_wait_shared

Referring to 3.5.4, total heater-on time depends on number of TPHG sequence, time taken for TPHG measurement and wait phase of each TPHG sequence. gas_wait_x<7:0> sets number of times TPHG sequence needs to be repeated.

The number of TPHG sub-measurement sequences within the one Gas conversion for one target temperature resistance is defined by gas_wait_X(7:0) settings. The duration of measurement is calculated as follows: Duration = gas_wait_X × (wait time defined by gas_wait_shared + TTPHG_duration)

Heater stepRegister nameAddressContentDescription
0...9gas_wait_xx is from 0 to 90x64...0x6Dgas_wait_x&lt;7:0&gt;x is from 0 to 9255 values with1 LSB corresponds to 1 TPHG sequence, all zeros means gas_wait_shared is fully skipped and one TPHG sequence is executed.

gas_wait_shared<7:0> sets wait time before each TPHG measurement sequence with duration as configured below. This is common for the whole gas measurement sequence in parallel mode.

Register NameAddressContentDescription
gas_wait_shared0x6Egas_wait_shared&lt;5:0&gt;64 timer values with 0.477ms step sizes, all zeros means no wait. gas_wait_shared=0x00 is treated as if gas_wait_shared=0x01.
gas_wait_shared&lt;7:6&gt;Gas sensor wait time multiplication factor
001
014
1016
1164

5.3.4.5 Heater off - heat_off

Register NameAddressContentDescription
ctrl_gas_00x70heat_off &lt;3&gt;Turn off current injected to heater by setting bit to one

5.3.4.6 Heater profile selection- nb_conv

nb_conv set heater profile of the sensor.

Register NameAddressContentDescription
ctrl_gas_10x71nb_conv&lt;3:0&gt;Forced mode: Indicates index of heater step that will be used in forced mode as describe in below tableParallel mode: Indicates sequence of up to 10 heater steps as describe in below table

In forced mode:

nb_conv&lt;3:0&gt;Heater step
00000
00011
00102
00113
01004
01015
01106
01117
10008
10019

In parallel mode:

nb_conv&lt;3:0&gt;Length of heater profile
0000No conversion
0001Heater step 0
0010Heater step 0-1
0011Heater step 0-2
0100Heater step 0-3
0101Heater step 0-4
0110Heater step 0-5
0111Heater step 0-6
1000Heater step 0-7
1001Heater step 0-8
1010 to 1111Heater step 0-9

Each heater step in profile has specific heater temperature and heater-on time and gas_meas_index register (see 5.3.6.4) stores index of heater step (up to 10 steps numbered from 0 to 9) corresponding to TPHG data.

5.3.4.7 Run Gas - run_gas

Register NameAddressContentDescription
ctrl_gas_10x71run_gas&lt;5&gt;The gas conversions are started only in appropriate mode if run_gas = ‘1’

Data registers

In this section, the data registers for the temperature, pressure, humidity and gas sensors are explained. Shadowing registers are utilized to buffer the data and to ensure stable data in case an update of the data registers occurs simultaneously with the serial interface reading out.

3 fields store TPHG data, status bits and time indexes:

• In forced mode only field 0 is used,

• In parallel mode, fields are filled from 0 to 2 and overwritten if more than 3 heater steps have been selected (5.3.4.6).

5.3.5.1 Pressure data

Register Name[Field]AddressContentDescription
press_msb [0]0x1Fpress_msb&lt;7:0&gt;Contains the MSB part [19:12] of the raw pressure measurement output data.
press_msb [1]0x30
press_msb [2]0x41
press_lsb [0]0x20press_lsb&lt;7:0&gt;Contains the LSB part [11:4] of the raw pressure measurement output data
press_lsb [1]0x31
press_lsb [2]0x42
press_xlsb [0]0x21press_xlsb&lt;7:4&gt;Contains the XLSB part [3:0] of the raw pressure measurement output data. Contents depend on pressure resolution controlled by oversampling setting.
press_xlsb [1]0x32
press_xlsb [2]0x43

5.3.5.2 Temp data

Register Name[Field]AddressContentDescription
temp_msb [0]0x22temp_msb&lt;7:0&gt;Contains the MSB part [19:12] of the raw temperature measurement output data.
temp_msb [1]0x33
temp_msb [2]0x44
temp_lsb [0]0x23temp_lsb&lt;7:0&gt;Contains the LSB part [11:4] of the raw temperature measurement output data.
temp_lsb [1]0x34
temp_lsb [2]0x45
temp_xlsb [0]0x24temp_xlsb&lt;7:4&gt;Contains the XLSB part [3:0] of the raw temperature measurement output data. Contents depend on temperature resolution controlled by oversampling setting.
temp_xlsb [1]0x35
temp_xlsb [2]0x46

5.3.5.3 Humidity data

Register Name[Field]AddressContentDescription
hum_msb [0]0x25hum_msb&lt;7:0&gt;Contains the MSB part [15:8] of the raw humidity measurement output data.
hum_msb [1]0x36
hum_msb [2]0x47
hum_lsb [0]0x26hum_lsb&lt;7:0&gt;Contains the LSB part [7:0] of the raw humidity measurement output data.
hum_lsb [1]0x37
hum_lsb [2]0x48

5.3.5.4 Gas resistance data

Register Name [Field]AddressContentDescription
gas_r_msb [0]0x2Cgas_r&lt;7:0&gt;Contains the MSB part gas resistance [9:2] of the raw gas resistance.
gas_r_msb [1]0x3D
gas_r_msb [2]0x4E
gas_r_lsb [0]0x2Dgas_r&lt;7:6&gt;Contains the LSB part gas resistance [1:0] of the raw gas resistance.
gas_r_lsb [1]0x3E
gas_r_lsb [2]0x4F

5.3.5.5 Gas resistance range

Register Name [Field]AddressContentDescription
gas_r_lsb [0]0x2Dgas_range_r&lt;3:0&gt;Contains ADC range of measured gas resistance.
gas_r_lsb [1]0x3E
gas_r_lsb [2]0x4F

Status registers

The measured data are stored into the output data registers at the end of each TPHG conversion phase along with status flags and index of measurement

5.3.6.1 New data status

Register Name [Field]AddressContentDescription
meas_status [0]0x1Dnew_data&lt;7&gt;New data flag indicate that data field contains a new data, not already read-out.
meas_status [1]0x2E
meas_status [2]0x3F

5.3.6.2 Gas measuring status

Measuring bit is set to 1 only during gas measurements, goes to 0 as soon as measurement is completed and data transferred to data registers. The registers storing the configuration values for the measurement (gas_wait_shared, gas_wait_x, res_heat_x, idac_heat_x, image registers) should not be changed when the device is measuring.

Register Name [Field]AddressContentDescription
meas_status [0]0x1Dgas_measuring&lt;6&gt;Gas measuring status flag
meas_status [1]0x2E
meas_status [2]0x3F

5.3.6.3 Measuring status

Measuring status will be set to ‘1’ whenever a conversion (temperature, pressure, humidity and gas) is running and back to ‘0’ when the results have been transferred to the data registers.

Register Name [Field]AddressContentDescription
meas_status [0]0x1Dmeasuring&lt;5&gt;Measuring status flag
meas_status [1]0x2E
meas_status [2]0x3F

5.3.6.4 Gas Measurement Index

User can trigger a heater profile of up to 10 heater steps by setting nb_conv<3:0>(see 5.3.4.6).

Each heater step in profile has specific heater temperature and heater-on time and gas_meas_index register stores index of heater step (up to 10 steps numbered from 0 to 9) corresponding to TPHG data

Register Name[Field]AddressContentDescription
meas_status [0]0x1D
meas_status [1]0x2Egas_meas_index_0&lt;3:0&gt;Gas measurement index
meas_status [2]0x3F

5.3.6.5 Gas valid status

In each TPHG sequence in parallel mode contains a gas measurement slot, either a real one which result is used or a dummy one to keep a constant sampling rate and predictable device timing. A real gas conversion (i.e., not a dummy one) is indicated by the gas_valid_r status register.

Register Name[Field]AddressContentDescription
gas_r_lsb [0]0x2Dgas_valid_r&lt;5&gt;Gas valid bit
gas_r_lsb [1]0x3E
gas_r_lsb [2]0x4F

5.3.6.6 Heater Stability Status

Heater temperature stability for target heater resistance is indicated heat_stab_x status bits and updated with data registers.The heater stability flag behavior depends on the current device mode:

• Forced mode: Stability is monitored only during the auto ranging sequences for gas measurements.

• Parallel mode: Stability is monitored from the beginning of the last one TPHG sequence (the on

containing the real gas measurements) to the end of the gas measurement.

Register Name[Field]AddressContentDescription
gas_r_lsb [0]0x2Dheat_stab_r&lt;4&gt;Heater stability bit
gas_r_lsb [1]0x3E
gas_r_lsb [2]0x4F

5.3.6.7 Sub Measurement Index

Indicates current TPHG sequence number on operating sensor on parallel mode, which are incremented for each TPHG measurement. These status bytes form “virtual time sensor” and contain a snapshot of the internal 8 bit conversion counter since the last change of device mode.

Register Name[Field]AddressContentDescription
sub_meas_index [0]0x1Esub_meas_index&lt;7:0&gt;TPHG measurement sequence number
sub_meas_index [1]0x2F
sub_meas_index [2]0x40

6. Digital interfaces

The sensor supports the I²C and SPI digital interfaces, where it acts as a slave for both protocols. The I²C interface supports the Standard, Fast and High Speed modes. The SPI interface supports both SPI mode ‘00’ (CPOL = CPHA = ‘0’) and mode ‘11’ (CPOL = CPHA = ‘1’) in 4-wire and 3-wire configuration.

The following transactions are supported:

• Single byte write

• multiple byte write (using pairs of register addresses and register data)

• single byte read

• multiple byte read (using a single register address which is auto-incremented)

6.1 Interface selection

Interface selection is done automatically based on CSB (chip select) status. If CSB is connected to V , the I²C interface is active. If CSB is pulled down, the SPI interface is activated. After CSB has been pulled down once (regardless of whethe any clock cycle occurred), the I²C interface is disabled until the next power-on-reset. This is done in order to avoid inadvertently decoding SPI traffic to another slave as I²C data. Since the device startup is deferred until both VDD and VDDIO are established, there is no risk of incorrect protocol detection because of the power-up sequence used. However, if I²C is to be used and CSB is not directly connected to V but is instead connected to a programmable pin, it must be ensured tha this pin already outputs the VDDIO level during power-on-reset of the device. If this is not the case, the device will be locked in SPI mode and not respond to I²C commands.

6.2 I²C Interface

For detailed timings, please review Table 24 . All modes (standard, fast, high speed) are supported. SDA and SCL are not pure open-drain. Both pads contain ESD protection diodes to VDDIO and GND. As the devices does not perform clock stretching, the SCL structure is a high-Z input without drain capability.


Picture 6: SDI/SCK ESD schematic

The 7-bit device address is 111011x. The 6 MSB bits are fixed. The last bit is changeable by SDO value and can be changed during operation. Connecting SDO to GND results in slave address 1110110 (0x76); connection it to V results in slave address 1110111 (0x77), which is the same as BMP280’s I²C address. The SDO pin cannot be left floating; if left floating, the I²C address will be undefined.

The I²C interface uses the following pins:

• SCK: serial clock (SCL)

• SDI: data (SDA)

• SDO: Slave address LSB (GND = ‘0’, VDDIO = ‘1’)

CSB must be connected to V to select I²C interface. SDI is bi-directional with open drain to GND: it must be externally connected to VDDIO via a pull up resistor. Refer to Chapter 7 for connection instructions.

The following abbreviations will be used in the I²C protocol figures:

S Start

P Stop

• ACKS Acknowledge by slave

• ACKM Acknowledge by master

NACKM Not acknowledge by master

I²C write

Writing is done by sending the slave address in write mode (RW = ‘0’), resulting in slave address 111011X0 (‘X’ is determined by state of SDO pin. Then the master sends pairs of register addresses and register data. The transaction is ended by a stop condition. This is depicted in Picture 7.


Picture 7: I²C multiple byte write (not auto-incremented)

I²C read

To be able to read registers, first the register address must be sent in write mode (slave address 111011X0). Then either a stop or a repeated start condition must be generated. After this the slave is addressed in read mode (RW = ‘1’) at address 111011X1, after which the slave sends out data from auto-incremented register addresses until a NOACKM and stop condition occurs. This is depicted in Picture 8, where register 0xF6 and 0xF7 are read.


Picture 8: I²C multiple byte read

6.3 SPI interface

The SPI interface is compatible with SPI mode $^ { \circ } 0 0 ^ { \circ } \left( \mathsf { C P O L } = \mathsf { C P H A } = ^ { \circ } 0 ^ { \circ } \right)$ and mode $\cdot 1 1 ^ { \circ } ( \mathsf { C P O L } = \mathsf { C P H A } = ^ { \circ } 1 ^ { \circ } )$ . The automatic selection between mode ‘00’ and ‘11’ is determined by the value of SCK after the CSB falling edge.

The SPI interface has two modes, namely 4-wire and 3-wire mode. However, the protocol is the same for both. The 3-wire mode is selected by setting ‘1’ to the register spi3w_en. The pad SDI is used as a data pad in 3-wire mode.

The SPI interface uses the following pins:

• CSB: chip select, active low

• SCK: serial clock

• SDI: serial data input; data input/output in 3-wire mode

• SDO: serial data output; hi-Z in 3-wire mode

For more connection instructions, please refer to Chapter 7.

CSB is active low and has an integrated pull-up resistor. Data on SDI is latched by the device at SCK rising edge and SDO is changed at SCK falling edge. Communication starts when CSB goes to low and stops when CSB goes to high; during these transitions on CSB, SCK must be stable. The SPI protocol is shown in It is important to note that Picture 9. For timing details, please review Table 25.


Picture 9: SPI protocol (shown for mode ‘11’ in 4-wire configuration)

It is important to note that in the SPI mode, only 7 bits of the register addresses are used; the MSB of register address is not used and replaced by a read/write bit (RW = ‘0’ for write and RW = ‘1’ for read). For example, address 0xF7 is accessed by using SPI register address 0x77. On the one hand, the byte 0x77 is transferred for write access, and on the other hand, the byte 0xF7 is transferred for read access.

SPI write

Writing is done by lowering CSB and sending pairs control bytes and register data. The control bytes consist of the SPI register address (= full register address without bit 7) and the write command (bit7 = RW = ‘0’). Several pairs can be written without raising CSB. The transaction is ended by a raising CSB. The SPI write protocol is depicted in Picture 10.

Control byteData byteControl byteData byte
StartRWRegister address (F4h)Data register - address F4hRWRegister address (F5h)Data register - adress F5hStop
CSB=001110100bit7bit6bit5bit4bit3bit2bit1bit001110101bit7bit6bit5bit4bit3bit2bit1bit0CSB=1

Picture 10: SPI multiple byte write (not auto-incremented)

SPI read

Reading is done by lowering CSB and first sending one control byte. The control bytes consist of the SPI register address (= full register address without bit 7) and the read command (bit $7 = \mathsf { R W } = { \mathsf { \Omega } } ^ { \ast } 1 ^ { \mathfrak { n } } )$ . After writing the contro byte, data is sent out of the SDO pin (SDI in 3-wire mode); the register address is automatically incremented. The SPI read protocol is depicted in Picture 11.

Control byteData byteData byte
StartRWRegister address (F6h)Data register - address F6hData register - address F7hStop
CSB=011110110bit15bit14bit13bit12bit11bit10bit9bit8bit7bit6bit5bit4bit3bit2bit1bit0CSB=1

Picture 11: SPI multiple byte read

6.4 Interface parameter specification

General interface parameters

Table 23: Interface parameters

ParameterSymbolConditionMinTypMaxUnit
Input low level $V_{il\_si}$ $V_{DDIO}=1.2 V to 3.6 V$ 20% $V_{DDIO}$
Input high level $V_{ih\_si}$ $V_{DDIO}=1.2 V to 3.6 V$ 80% $V_{DDIO}$
Output low level $I^{2}C$ $V_{ol\_SDI}$ $V_{DDIO}=1.62 V, I_{ol}=3 mA$ 20% $V_{DDIO}$
Output low level $I^{2}C$ $V_{ol\_SDI\_1.2}$ $V_{DDIO}=1.20 V, I_{ol}=3 mA$ 23% $V_{DDIO}$
Output low level SPI $V_{ol\_SDO}$ $V_{DDIO}=1.62 V, I_{ol}=1 mA$ 20% $V_{DDIO}$
Output low level SPI $V_{ol\_SDO\_1.2}$ $V_{DDIO}=1.20 V, I_{ol}=1 mA$ 23% $V_{DDIO}$
Output high level $V_{oh}$ $V_{DDIO}=1.62 V, I_{oh}=1 mA (SDO, SDI)$ 80% $V_{DDIO}$
Output high level $V_{oh\_1.2}$ $V_{DDIO}=1.20 V, I_{oh}=1 mA (SDO, SDI)$ 60% $V_{DDIO}$
Pull-up resistor $R_{pull}$ Internal CSB pull-up resistor to $V_{DDIO}$ 70120190kΩ
$I^{2}C bus load capacitor$ $C_b$ On SDI and SCK400pF

I²C timings

For I²C timings, the following abbreviations are used:

• “S&F mode” = standard and fast mode

• “HS mode” = high speed mode

• Cb = bus capacitance on SDA line

All other naming refers to I²C specification 2.1 (January 2000).

The I²C timing diagram is in Picture 12. The corresponding values are given in Table 24


Picture 12: I2C timing diagram

Table 24: I2C timings

ParameterSymbolConditionMinTypMaxUnit
SDI setup time $t_{SU;DAT}$ S&amp;F ModeHS mode16030nsns
SDI hold time $t_{HD;DAT}$ S&amp;F Mode, $C_b\leq 100$ pFS&amp;F Mode, $C_b\leq 400$ pFHS mode, $C_b\leq 100$ pFHS mode, $C_b\leq 400$ pF80901824115150nsnsns
SCK low pulse $t_{LOW}$ HS mode, $C_b\leq 100$ pF $V_{DDIO}=1.62 V$ 160ns
SCK low pulse $t_{LOW}$ HS mode, $C_b\leq 100$ pF $V_{DDIO}=1.2 V$ 210ns

The above-mentioned I2C specific timings correspond to the following internal added delays:

Input delay between SDI and SCK inputs: SDI is more delayed than SCK by typically 100 ns in Standard and Fast Modes and by typically 20 ns in High Speed Mode.

Output delay from SCK falling edge to SDI output propagation is typically 140 ns in Standard and Fast Modes and typically 70 ns in High Speed Mode.

SPI timings

The SPI timing diagram is in Picture 13, while the corresponding values are given in Table 25. All timings apply both to 4- and 3-wire SPI.


Picture 13: SPI timing diagram

Table 25: SPI timings

ParameterSymbolConditionMinTypMaxUnit
SPI clock i/p frequencyF_spi010MHz
SCK low pulseT_low_sck20ns
SCK high pulseT_high_sck20ns
SDI setup timeT_setup_sdi20ns
SDI hold timeT_hold_sdi20ns
SDO output delayT_delay_sdo25 pF load, $V_{DDIO}=1.6$ V min30ns
SDO output delayT_delay_sdo25 pF load, $V_{DDIO}=1.2$ V min40ns
CSB setup timeT_setup_csb20ns
CSB hold timeT_hold_csb20ns
SPI clock input frequencyF_spi010MHz

7. Pin-out and connection diagram

7.1 Pin-out

The pin numbering of BME688 is performed in the untypical clockwise direction when seen in top view and counter-clockwise when seen in bottom view. Picture 14 and Table 26 give a detailed description and illustration of the input/output pins.


Picture 14: Top (left) and bottom (right) views of the chip with input/output pins

Table 26: Pin description

PinNameI/O typeDescriptionConnection
SPI 4WSPI 3W $I^2C$
1GNDSupplyGroundGND
2CSBInChip selectCSBCSB $V_{DDIO}$
3SDIIn/OutSerial data inputSDISDI/SDOSDA
4SCKInSerial clock inputSCKSCKSCL
5SDOIn/OutSerial data outputSDODNCGND for default address
6 $V_{DDIO}$ SupplyDigital / Interface supply $V_{DDIO}$
7GNDSupplyGroundGND
8 $V_{DD}$ SupplyAnalog supply $V_{DD}$

7.2 Connection diagrams

For the I2C connection, it is recommended to use 100 nF for ${ \mathsf { C } } 1$ and $\mathsf { C } _ { 2 } .$ . Moreover, the value for the pull-up resistors $\mathsf { R } _ { 1 }$ and ${ \sf R } _ { 2 }$ should be based on the interface timing and the bus load; a normal value is 4.7 kΩ. Finally, a direct connection between CSB and V is required. Similarly for the 4- and 3-wire SPI connections, it is suggested to use 100 nF for $\mathsf { C } _ { 1 }$ and $\mathsf { C } _ { 2 } .$

(a)

(b)


(c)
Picture 15: Connection diagrams for (a) I2C, (b) 4-wire SPI, and (c) 3-wire SPI

7.3 Package dimensions


2. REFERENCE SPECIFICATIONS: A. AWW SPEC #001-0531-2234: PACKING OPERATION PROCEDURE B. AWW SPEC #001-0519-2062: MARKING.

  1. ALL DIMENSIONS AND TOLERANCES CONFORM TO ANSI Y14.5M-1994.

NOTES: UNLESS OTHERWISE SPECIFIED


Picture 16: Package dimensions for top, bottom and side view

7.4 Landing pattern recommendation

For the design of the landing pattern, the dimensions shown in Picture 17: Recommended landing pattern (top view; dimensions are in millimeters) are recommended. It is important to note that areas marked in red are exposed PCB metal pads.

In case of a solder mask defined (SMD) PCB process, the land dimensions should be defined by solder mask openings. The underlying metal pads are larger than these openings.

In case of a non-solder mask defined (NSMD) PCB process, the land dimensions should be defined in the meta layer. The mask openings are larger than these metal pads.


Picture 17: Recommended landing pattern (top view; dimensions are in millimeters)

7.5 Marking

Mass production devices

Table 27: Marking of mass production parts

MarkingSymbolDescription
Vent hole5 6 7 8CCC TLPin 1 marker4 3 2 1CCCLot counter: 3 alphanumeric digits, variable to generate mass production trace-code
TProduct number: 1 alphanumeric digit, fixed to identify product type.“T” identifies the BME688 w/ the part no.0 273 017 016
LSub-contractor ID: 1 alphanumeric digit, variable to identify sub-contractor (L = “P”)

Note: The product numbers “S” and “E” identify the BME680.

Engineering samples

Table 28: Marking of engineering samples

MarkingSymbolDescription
5 6 7 8Venthole →OXXNCC←Pin 1markerXXSample ID: 2-3 alphanumeric digits, variable to generate trace-code
NEng. Sample ID: 1 alphanumeric digit, fixed to identify engineering sample, N = “*” or “e” or “E”
CCCounter ID: 2-3 alphanumeric digits, variable to generate trace-code

Note: Early engineering samples (e.g. w/ marking “688E HR1”) did not yet have a flashed variant_id as described in chapter 5.3.2.1. Consequently, they are not automatically recognized by the API. In order to ensure correct function, the API needs to be manually modified according to the used variant.

7.6 Soldering guidelines and reconditioning recommendations

The moisture sensitivity level of the BME688 sensors corresponds to JEDEC Level 1, see also:

• IPC/JEDEC J-STD-020C “Joint Industry Standard: Moisture/Reflow Sensitivity Classification for non-hermetic Solid State Surface Mount Devices”

• IPC/JEDEC J-STD-033A “Joint Industry Standard: Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices”

The sensor fulfils the lead-free soldering requirements of the above-mentioned IPC/JEDEC standard, i.e. reflow soldering with a peak temperature up to $2 6 0 ^ { \circ } \mathsf { C }$ . The minimum height of the solder after reflow shall be at least 50 µm. This is required for good mechanical decoupling between the sensor device and the printed circuit board (PCB).

Profile FeaturePb-Free Assembly
Average Ramp-Up Rate (Tsmax to Tp)3°C/second max.
Preheat- Temperature Min (Tsmin)- Temperature Max (Tsmax)- Time (tsmin to tsmax)150 °C200 °C60-180 seconds
Time maintained above:- Temperature (TL)- Time (tL)217 °C60-150 seconds
Peak/Classification Temperature (Tp)260 °C
Time within 5 °C of actual Peak Temperature (tp)20-40 seconds
Ramp-Down Rate6 °C/second max.
Time 25 °C to Peak Temperature8 minutes max.

Note 1: All temperatures refer to topside of the package, measured on the package body surface


Picture 18: Soldering profile

7.7 Mounting and assembly recommendations

This HSMI-document provides all the necessary instructions to handle, solder and mount the environmental sensor BME688. Following the reported guidelines is very important to prevent the damage of the sensor and the resultant loss of warranty.

7.8 Environmental safety

RoHS

The BME688 sensor meets the requirements of the EC restriction of hazardous substances (RoHS) directive, see also:

Directive 2011/65/EU and its amendments, including the amendment 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

Halogen content

The BME688 is halogen-free. For more details on the analysis results please contact your Bosch Sensortec representative.

Internal package structure

Within the scope of Bosch Sensortec’s ambition to improve its products and secure the mass product supply, Bosch Sensortec qualifies additional sources (e.g. 2nd source) for the packaging and processing of the BME688.

While Bosch Sensortec took care that all of the technical packages parameters are described above are 100% identical for all sources, there can be differences in the chemical content and the internal structural between the different package sources.

However, as secured by the extensive product qualification process of Bosch Sensortec, this has no impact to the usage or to the quality of the BME688 product.

8. Legal disclaimer

8.1 Engineering samples

Engineering Samples are marked with an asterisk (*), (E) or (e). Samples may vary from the valid technical specifications of the product series contained in this data sheet. They are therefore not intended or fit for resale to third parties or for use in end products. Their sole purpose is internal client testing. The testing of an engineering sample may in no way replace the testing of a product series. Bosch Sensortec assumes no liability for the use of engineering samples. The Purchaser shall indemnify Bosch Sensortec from all claims arising from the use of engineering samples.

8.2 Product use

Bosch Sensortec products are developed for the consumer goods industry. They may only be used within the parameters of this product data sheet. They are not fit for use in life-sustaining or safety-critical systems. Safety critical systems are those for which a malfunction is expected to lead to bodily harm, death or severe property damage. In addition, they shall not be used directly or indirectly for military purposes (including but not limited to nuclear, chemical or biological proliferation of weapons or development of missile technology), nuclear power, deep sea or space applications (including but not limited to satellite technology).

Bosch Sensortec products are released on the basis of the legal and normative requirements relevant to the Bosch Sensortec product for use in the following geographical target market: BE, BG, DK, DE, EE, FI, FR, GR, IE, IT, HR, LV, LT, LU, MT, NL, AT, PL, PT, RO, SE, SK, SI, ES, CZ, HU, CY, US, CN, JP, KR, TW. If you need further information or have further requirements, please contact your local sales contact.

The resale and/or use of Bosch Sensortec products are at the purchaser’s own risk and his own responsibility. The examination of fitness for the intended use is the sole responsibility of the purchaser.

The purchaser shall indemnify Bosch Sensortec from all third party claims arising from any product use not covered by the parameters of this product data sheet or not approved by Bosch Sensortec and reimburse Bosch Sensortec for all costs in connection with such claims.

The purchaser accepts the responsibility to monitor the market for the purchased products, particularly with regard to product safety, and to inform Bosch Sensortec without delay of all safety-critical incidents

8.3 Application examples and hints

With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Bosch Sensortec hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights or copyrights of any third party. The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. They are provided for illustrative purposes only and no evaluation regarding infringement of intellectual property rights or copyrights or regarding functionality, performance or error has been made.

9. Document history and modifications

Rev.ChapterDescription of modificationsDate
1.0Initial releaseApril 2021
1.11.2Sensitivity (SH2S) &amp; F1-score (F1H2S) improved by updated BSEC 2.2.0.0 software (Table 4)Typical IAQ range updated according to BSEC 2.2.0.0 software improvements (Table 6)July 2022
1.5Temperature accuracy (AT) improved (Table 10)
5.2Memory Map for ctrl_gas_1 updated (Table 22)
5.3.4.7Bit position updated for ctrl_gas_1
1.2GeneralUpdated Typical Applications and Target DevicesFebruary 2024
1.32Removed condensation parameter from table 11February 2024

www.bosch-sensortec.com

Bosch Sensortec GmbH Gerhard-Kindler-Straße 9 72770 Reutlingen / Germany

Extracted Images

Figures and diagrams from the PDF

Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.

176611a0dc7da81da3ee3a467b4e02e294704b057ac2a0d55998649e8aba99c9.jpg

176611a0dc7da81da3ee3a467b4e02e294704b057ac2a0d55998649e8aba99c9.jpg

6693326992682d37bada3ac8f536efb64e9f93d7bb4826ac3adad30a9a883d8d.jpg

6693326992682d37bada3ac8f536efb64e9f93d7bb4826ac3adad30a9a883d8d.jpg

fa69e678f14f3371978c4485ffbe550e402c042598faed1467ad2894b35c4881.jpg

fa69e678f14f3371978c4485ffbe550e402c042598faed1467ad2894b35c4881.jpg

37d555255610e9049aae2214ef2708a43b53a743d42d0001c7b802a35ac4d4ab.jpg

37d555255610e9049aae2214ef2708a43b53a743d42d0001c7b802a35ac4d4ab.jpg

7e2d322c0ffce5468938f21b330ab821991dd08cf72476624cde3e9d0e2ce3b4.jpg

7e2d322c0ffce5468938f21b330ab821991dd08cf72476624cde3e9d0e2ce3b4.jpg

0713cc6d7be5557f158b20ed72e156f9334a59c9c884e4ae53f2fff385f6fc9f.jpg

0713cc6d7be5557f158b20ed72e156f9334a59c9c884e4ae53f2fff385f6fc9f.jpg

8b7c6e0854f4575369c9d49dc979a002540998cb7252c4fb23ec6d754b42fc17.jpg

8b7c6e0854f4575369c9d49dc979a002540998cb7252c4fb23ec6d754b42fc17.jpg

e84dd3ecab7b4bf63b770691ee6e43c7e79ed0ca75ad27b702f72bb32a09a07f.jpg

e84dd3ecab7b4bf63b770691ee6e43c7e79ed0ca75ad27b702f72bb32a09a07f.jpg

ac855c06764c4b8d6ef6cd0f411a44bedd46960594ff4ba1b99e17f4b033f481.jpg

ac855c06764c4b8d6ef6cd0f411a44bedd46960594ff4ba1b99e17f4b033f481.jpg

2b120c892c6915a83889912b5cc6127b5d14a4e4dff2a3f0e444efcb9ca17a6c.jpg

2b120c892c6915a83889912b5cc6127b5d14a4e4dff2a3f0e444efcb9ca17a6c.jpg

0601e89676cc0ef0957dcf79d893d3abc4a49f9234ac870e15c054f754ec2f47.jpg

0601e89676cc0ef0957dcf79d893d3abc4a49f9234ac870e15c054f754ec2f47.jpg

43e6054b8a7c83235995e9307c2c7c3bdabff650aac6df849cb54313dc6fe0b6.jpg

43e6054b8a7c83235995e9307c2c7c3bdabff650aac6df849cb54313dc6fe0b6.jpg

197302e351e0378fb321707e2690da257d0480a8d532cfe6c8caa40277f25946.jpg

197302e351e0378fb321707e2690da257d0480a8d532cfe6c8caa40277f25946.jpg

1c3b923e969ccda43c240a624f173097f6bbf412094e4acb43b8e92ea0eb87b6.jpg

1c3b923e969ccda43c240a624f173097f6bbf412094e4acb43b8e92ea0eb87b6.jpg

bec91eec63a2f52815d3909da376ef5e7a64c2a2f2306492eceb0e2963e176a5.jpg

bec91eec63a2f52815d3909da376ef5e7a64c2a2f2306492eceb0e2963e176a5.jpg

7ffdb999013a6d5cb8e89b907a1fc51136489f02e5a3c7129ac74281a2f7766b.jpg

7ffdb999013a6d5cb8e89b907a1fc51136489f02e5a3c7129ac74281a2f7766b.jpg

beac341880bf721ac96d43ab9758b23a34290410050ed12e98d3ba9a89531b8a.jpg

beac341880bf721ac96d43ab9758b23a34290410050ed12e98d3ba9a89531b8a.jpg

a9f27d4a439808aa9dea03540a5ee61700e1d884891ba622618bf5f8d887506d.jpg

a9f27d4a439808aa9dea03540a5ee61700e1d884891ba622618bf5f8d887506d.jpg

9e5e616efbbc8e17598ad3bebed8e8f8692fb6b95261c837d809feef6d60a02a.jpg

9e5e616efbbc8e17598ad3bebed8e8f8692fb6b95261c837d809feef6d60a02a.jpg

f63dfefc29adef268b9971a4ce3754f1a21f7ea4c389f6d1b8e714d34a326994.jpg

f63dfefc29adef268b9971a4ce3754f1a21f7ea4c389f6d1b8e714d34a326994.jpg

a0e7223105307534a507d7922fad6e816b624399aa993a9394ba85d557c5114f.jpg

a0e7223105307534a507d7922fad6e816b624399aa993a9394ba85d557c5114f.jpg

dbcb7d2fbc342207a80952024032a8e53df5d74aeb8011b219d7048507049173.jpg

dbcb7d2fbc342207a80952024032a8e53df5d74aeb8011b219d7048507049173.jpg

9ea67fef31a2d4d3d57c7de0bad5a8046de1ba32bf90349942eb801e2062e666.jpg

9ea67fef31a2d4d3d57c7de0bad5a8046de1ba32bf90349942eb801e2062e666.jpg

ae99e10a94a26334b4ffeef991267f4cb3a033147355ee9aec94eaebded8063c.jpg

ae99e10a94a26334b4ffeef991267f4cb3a033147355ee9aec94eaebded8063c.jpg

5322558b3f8cc568c5148d11262e98d30e1482f7af84b8e768b5ba1a68818119.jpg

5322558b3f8cc568c5148d11262e98d30e1482f7af84b8e768b5ba1a68818119.jpg

fd51ff1602c4725eb2841798c70df92a9850bf91db661da33195fbeb6b9980ea.jpg

fd51ff1602c4725eb2841798c70df92a9850bf91db661da33195fbeb6b9980ea.jpg

849c38ab2f1625cd5effd128c271564d4a066953ac20bda4d6265eb88110c584.jpg

849c38ab2f1625cd5effd128c271564d4a066953ac20bda4d6265eb88110c584.jpg

c2fc8d35e4f2b1b7a669fc0812e86fe162e68fde9fe88b2370004951b51916df.jpg

c2fc8d35e4f2b1b7a669fc0812e86fe162e68fde9fe88b2370004951b51916df.jpg

53baee3f229ff48db129f9e1c2d8a18930c122aa4c348f4256165092af7158d7.jpg

53baee3f229ff48db129f9e1c2d8a18930c122aa4c348f4256165092af7158d7.jpg

8437a4e84a3850e9674f9739fe52914fc2108a1f9d3921334a626816a3f3aed2.jpg

8437a4e84a3850e9674f9739fe52914fc2108a1f9d3921334a626816a3f3aed2.jpg

10e6d5a94c55e163ad3d8d0230e312373d931aecfa1b1960446c59c4b93b2295.jpg

10e6d5a94c55e163ad3d8d0230e312373d931aecfa1b1960446c59c4b93b2295.jpg

e7935e67c470e123ac1a473ba68a34e9563ef142b35e1ccc791d98727641f592.jpg

e7935e67c470e123ac1a473ba68a34e9563ef142b35e1ccc791d98727641f592.jpg

d3450964a75a09e2f4c5b27191f0761a8b2d58741b57c4347e9a22488cc17fbf.jpg

d3450964a75a09e2f4c5b27191f0761a8b2d58741b57c4347e9a22488cc17fbf.jpg

fb68f7c078a29a8798d12b35f9de0a18d5c99ba49d39b7ce9503fad6a1d07a37.jpg

fb68f7c078a29a8798d12b35f9de0a18d5c99ba49d39b7ce9503fad6a1d07a37.jpg

cd62623a2971d7a7ba1579715b0c2ae5a85127e8bf7209ec743965723928a56e.jpg

cd62623a2971d7a7ba1579715b0c2ae5a85127e8bf7209ec743965723928a56e.jpg

78df8175157f053a8c908fdae4ae642813c8a0f8d9bb045cf880167884664e01.jpg

78df8175157f053a8c908fdae4ae642813c8a0f8d9bb045cf880167884664e01.jpg

0e1e2ba6aed3f6b5584854edd6f96e21b470dd5b16cc01c6c0934468d1623635.jpg

0e1e2ba6aed3f6b5584854edd6f96e21b470dd5b16cc01c6c0934468d1623635.jpg

e082cdee6d9423131ae2187987abd084c7e402bfb1bf092b136eea1cbaa26502.jpg

e082cdee6d9423131ae2187987abd084c7e402bfb1bf092b136eea1cbaa26502.jpg

9038763721d6a54bd3e924f88e3216d425ee4620f7b55c75184410992a70e2ea.jpg

9038763721d6a54bd3e924f88e3216d425ee4620f7b55c75184410992a70e2ea.jpg

3e6e53d8ac6539ca7f24bca3cb433e0087924313fed99d7bac0949a3a15c01e7.jpg

3e6e53d8ac6539ca7f24bca3cb433e0087924313fed99d7bac0949a3a15c01e7.jpg

29eb13e431d01b332270f7c6159a637ff7d66da30888a3b74234f48c04ffb897.jpg

29eb13e431d01b332270f7c6159a637ff7d66da30888a3b74234f48c04ffb897.jpg

b6037f68b64bc3e338a4c0fc5b6012315b71447a011e21276bfb0baeeb37e573.jpg

b6037f68b64bc3e338a4c0fc5b6012315b71447a011e21276bfb0baeeb37e573.jpg

b878e90b954548b78c148f63a6b476426d2ec8affc9eb0f935e5745b5fdfdcc3.jpg

b878e90b954548b78c148f63a6b476426d2ec8affc9eb0f935e5745b5fdfdcc3.jpg

15150712d9f4d09d88b70e7b2d6d08ae5483171d137eac31cd355fc2a68ae511.jpg

15150712d9f4d09d88b70e7b2d6d08ae5483171d137eac31cd355fc2a68ae511.jpg

48981843d336558af8c325d2f0689ad56b04f8bbbf8926f6644389b29cbaf642.jpg

48981843d336558af8c325d2f0689ad56b04f8bbbf8926f6644389b29cbaf642.jpg

e13c6e7d306f0a1cfacd16e409576d44fed04d5e37579cee6e28f1f5282c6532.jpg

e13c6e7d306f0a1cfacd16e409576d44fed04d5e37579cee6e28f1f5282c6532.jpg

7b7daf9f48ad34c4d5986cd47493da9038c13a487df22d12b4405314da0372d7.jpg

7b7daf9f48ad34c4d5986cd47493da9038c13a487df22d12b4405314da0372d7.jpg

652f56c22835d532b0fe9d8d058b80d005d58b54c97a4f2934037777beb0c7bc.jpg

652f56c22835d532b0fe9d8d058b80d005d58b54c97a4f2934037777beb0c7bc.jpg

dbaa479dd00550fb41341c9a74e44ca9f39ac92af36b38740edd5c8d1c57738d.jpg

dbaa479dd00550fb41341c9a74e44ca9f39ac92af36b38740edd5c8d1c57738d.jpg

9653017101da5b3985a895d239f481d4cee71e3cc1424e7779a7c8864c3e7ba1.jpg

9653017101da5b3985a895d239f481d4cee71e3cc1424e7779a7c8864c3e7ba1.jpg

c4ca2849c7dd0a2f9e49284e0fdc1e75bc4a8ec757b5efae7ed5db725f1858d8.jpg

c4ca2849c7dd0a2f9e49284e0fdc1e75bc4a8ec757b5efae7ed5db725f1858d8.jpg

ab09b64bea20cd8ba4b759e88abc6e1872cadb5515e704aafb689550924d1d01.jpg

ab09b64bea20cd8ba4b759e88abc6e1872cadb5515e704aafb689550924d1d01.jpg

9ecd60f82251560f668123ba733614ac59b3c582c21ee20952de27b84ef0a736.jpg

9ecd60f82251560f668123ba733614ac59b3c582c21ee20952de27b84ef0a736.jpg

52d9cba172ec479f6b4379e937071f79174fe23e8c63f227241333d0c3c9b14f.jpg

52d9cba172ec479f6b4379e937071f79174fe23e8c63f227241333d0c3c9b14f.jpg

120992789483de6eb26b53c37647d89669965d0d5b8857b9215781e3b5a7e280.jpg

120992789483de6eb26b53c37647d89669965d0d5b8857b9215781e3b5a7e280.jpg

ad57f3b14c01fb64229d2a465b87e9e83471e04d7546ab71b3dfd7f1d323c8fd.jpg

ad57f3b14c01fb64229d2a465b87e9e83471e04d7546ab71b3dfd7f1d323c8fd.jpg

045fe88a352187df3537b02b52ef667e73902da39f401fd415c7329a3aed0932.jpg

045fe88a352187df3537b02b52ef667e73902da39f401fd415c7329a3aed0932.jpg

efe4c51f5046f2a42f6a2f528bebf1c15232d1ddfdbcae67ecfd3cc7eeef3519.jpg

efe4c51f5046f2a42f6a2f528bebf1c15232d1ddfdbcae67ecfd3cc7eeef3519.jpg

db012f412fb7dfaf52a41722985a4559afeb02dab625aad7f6b3e891903c784f.jpg

db012f412fb7dfaf52a41722985a4559afeb02dab625aad7f6b3e891903c784f.jpg

6416c72e4caacb597a8e32aee35ab7fd8527c5002b91ca3b0871ae7388421271.jpg

6416c72e4caacb597a8e32aee35ab7fd8527c5002b91ca3b0871ae7388421271.jpg

Agent APIs

Use this datasheet from any agent

Send the page, markdown, chunks, or search endpoint to ChatGPT, Claude, embedr-app, or your own tooling.