Ebyte E32-433T20D
433 MHz, 20 dBm UART LoRa wireless module with TTL-level serial interface, AT command support, and SMA-K antenna connector.
Ebyte E32-T Series Module User Manual (EN) - transcription
Source: Chengdu Ebyte Electronic Technology Co., Ltd., E32-T Series User Manual (AT command 433/868/915 MHz LoRa wireless module), English edition, copyright 2012-2026, PDF created 2026-09-29, 48 pages, https://www.cdebyte.com/pdf-down.aspx?id=4218, SHA-256 ad67b10907df02af0d224c59427ecbd41a84307739b3eed7095d164bb06361de.
This document covers E32-433T20S, E32-433T20D, E32-433T30S, E32-433T30D, E32-900T20S, E32-900T20D, E32-900T30S and E32-900T30D. Below is a page-by-page text transcription extracted from the PDF text layer (layout preserved) with the PDF's own figures. The repeated Ebyte header logo is omitted.
E32-433T20D mechanical drawing dimensions (transcribed from PDF page 11, sec. 3.2)
| Item | Value (mm) |
|---|---|
| Module PCB outline | 21.0 x 36.0 |
| Header pin pitch | 2.54 (pins 1-7, single row) |
| Header row to short (header) edge | 1.50 |
| Pin 1 / pin 7 centre to long edges | 2.88 |
| Fixed holes 8-10 | 3.50 from the long edge + 2.54 pitch, 3.00 from the SMA end |
| SMA-K jack width | 6.20 |
| SMA-K overhang past module edge | 12.5 (body 11.1) |
| SMA-K centre from long edge (bottom view) | 15.6 |
| Side view, overall dimension as printed (header pin end to shield face) | 12.8 |
| Side view, callout at the shield/body | 4.20 |
| Module pad (top/bottom) | 1.50 x 2.00 oval, 0.90 hole |
| Tolerance | X.X +/-0.2, X.XX +/-0.05 |
| Pad quantity | 10 (7 header pins + 3 fixed holes) |
PDF page 1
E32-T Series Product Specifications
AT Command 433/868/915MHz LoRa Wireless Module

PDF page 2
Contents
Disclaimer and Copyright Notice ....................................................................................................错误!未定义书签。
1 Product Overview ...................................................................................................................................................................5
1.1 Brief Introduction ....................................................................................................................................... 5
1.2 Features ...................................................................................................................................................... 5
1.3 Application ................................................................................................................................................. 6
2 Specification and parameter .................................................................................................................................................6
2.1 E32-T Series Product Selection Comparison ............................................................................................. 6
2.2 Basic Parameters ........................................................................................................................................ 7
2.2.1 Basic Parameters ..................................................................................................................................... 7
3 Mechanical Dimensions and Pin Definitions ...................................................................................................................8
3.1 E32-433T20S & 900T20S Mechanical Dimensions and Pin Definitions .................................................. 8
3.2 E32-433T20D&900T20D Mechanical Dimensions and Pin Definitions .................................................10
3.3 E32-433T30S&900T30S Mechanical Dimensions and Pin Definitions .................................................. 11
3.4 E32-433T30D&900T30D Mechanical Dimensions and Pin Definitions .................................................13
4 Recommended Connection Diagram...............................................................................................................................14
5 Detailed Functionality........................................................................................................................................................ 15
5.1 Operating Mode ........................................................................................................................................15
5.1.1 Transmission mode in use: Mode 0 (M1 and M0 pins set to 0,0) ......................................................... 15
5.1.1.1 Quick Start Guide for Transparent Transfer .......................................................................................16
5.1.1.2 Quick Point-to-Point Transmission (Specify Destination Address and Channel) ..............................16
5.1.1.3 Quick Guide to Broadcasting ............................................................................................................. 18
5.1.2 Wake-up Mode, Mode 1 (M1, M0 pins set to 0,1) ................................................................................19
5.1.3 Power-saving mode, Mode 2 (M1 and M0 pins set to 1 and 0) ............................................................ 20
5.1.3.1 Quick Start Guide for Transparent Transfer .......................................................................................20
5.1.4 Sleep configuration mode in use, Mode 3 (M1, M0 pins set to 1,1) ..................................................... 21
5.1.4.1 Quick Start Guide for Configuration Tools ........................................................................................21
5.1.5 Precautions for Using Work Modes ...................................................................................................... 22
5.2 AUX Timing .............................................................................................................................................22
5.2.1 Power-On Start Indicator .......................................................................................................................22
5.2.2 Serial Port Data Output Indicator .......................................................................................................... 23
PDF page 3
5.2.3 Wireless Transmission Indicator ........................................................................................................... 24
5.2.4 Switch Mode ..........................................................................................................................................25
5.2.5 Notes ......................................................................................................................................................25
5.3 Serial Port Firmware Upgrade ..................................................................................................................26
5.3.1 Quick Guide to Host Computer Upgrade .............................................................................................. 26
6 Register Read/Write Control .............................................................................................................................................27
6.1 Command Introduction .............................................................................................................................27
6.2 Reading of Operating Parameters .............................................................................................................27
6.3 Version Number Reading ......................................................................................................................... 28
6.4 Reset command ........................................................................................................................................ 28
6.5 Register Function Reference Table .......................................................................................................... 28
6.6 Register Specifications ............................................................................................................................. 29
6.7 Register factory default parameters ..........................................................................................................31
7 AT command ........................................................................................................................................................................ 31
7.1 General Command ........................................................................................................................................................... 31
7.1.1 AT+RESET Software Reset ....................................................................................................................................... 31
7.1.2 AT+DEFAULT Restore factory settings .................................................................................................................32
7.1.3 AT+DEVTYPE Query Product Model .................................................................................................................... 32
7.1.4 AT+FWCODE Query Software Version.................................................................................................................32
7.1.5 AT+SWITCH Software Switching Mode Enable ................................................................................................. 33
7.1.6 AT+MODE Software Mode Switching ................................................................................................................... 33
7.1.7 AT+UAUX Wireless AUX Indicator Enable .........................................................................................................34
7.1.8 AT+ADDR Communication Address (Matching Filter)..................................................................................... 34
7.1.9 AT+CHANNEL Communication Channel (Carrier Frequency) ....................................................................... 35
7.1.10 AT+UART Serial Port Baud Rate and Parity...................................................................................................... 35
7.1.11 AT+URXT Serial Port Frame Disconnection Condition ...................................................................................36
7.1.12 AT+RATE Wireless Transmission Rate ............................................................................................................... 36
7.1.13 AT+TRANS Wireless Transmission Mode (Transparent/Fixed Point) ......................................................... 37
7.1.14 AT+WTIME Wake-on-Air Period......................................................................................................................... 37
7.1.15 AT+FEC Forward Error Correction ....................................................................................................................... 38
7.1.16 AT+POWER Power Tiering .................................................................................................................................... 38
7.2 Signaling Testing (Certification) .................................................................................................................................. 39
PDF page 4
7.2.1 Test Command Declaration........................................................................................................................................ 39
7.2.2 Test Command Reference ...........................................................................................................................................39
8 Hardware Design ................................................................................................................................................................. 40
9 Frequently Asked Questions............................................................................................................................................. 40
9.1 Transmission distance is not ideal ................................................................................................................................ 40
9.2 The module is vulnerable ............................................................................................................................................... 41
9.3 The error rate is too high ................................................................................................................................................ 41
9.4 Antenna Selection............................................................................................................................................................ 41
10 Welding Work Instructions............................................................................................................................................. 42
10.1 Reflow Soldering Temperature ...................................................................................................................................42
10.2 Reflow Soldering Profile Chart .................................................................................................................................. 43
11 Related Models.............................................................................................................................. 错误!未定义书签。
12 Antenna Guide ................................................................................................................................................................... 43
12.1 Antenna Recommendation...........................................................................................................................................43
13 Bulk Packaging Method...................................................................................................................................................45
13.1 E32-433T20S & E32-900T20S Bulk Packaging Method.....................................................................................45
13.2 Bulk Packaging Method for E32-433T20D(30D) & E32-900T20D(30D) .......................................................46
13.3 E32-433T30S & E32-900T30S Bulk Packaging Method.....................................................................................46
Revision history.......................................................................................................................................................................47
About us................................................................................................................................................错误!未定义书签。
PDF page 5
Disclaimer and Copyright Notice
The information contained herein, including the URLs for reference, is subject to change withou
t prior notice. This document is provided "as is" without any warranties, including but not limited to
warranties of merchantability, fitness for a particular purpose, and non-
infringement, as well as any warranties implied by proposals, specifications, or samples mentioned el
sewhere. The company shall not be liable for any claims, including liabilities arising from the use of
information in this document that may infringe upon any patent rights. No intellectual property licens
e, either express or implied, is granted herein by estoppel or otherwise.
All test data stated in this document are obtained by Ebyte Laboratory, and actual results may v
ary slightly.
All trade names, trademarks and registered trademarks mentioned herein are the property of thei
r respective owners.
This product is strictly prohibited from being used in military applications and life safety-
related scenarios. The user shall bear full responsibility for any unauthorized use.
Chengdu Ebyte Electronic Technology Co., Ltd. reserves the right of final interpretation.
Notice :
The content of this manual may be modified due to product version upgrades or other reasons. Chengdu Ebyte Electronic Technol
ogy Co., Ltd. reserves the right to revise the contents of this manual without prior notice. This manual is intended solely for operationa
l guidance. While every effort has been made to ensure the accuracy of the information herein, the company does not warrant that the c
ontent is entirely error-
free. All statements, information and recommendations contained in this manual shall not constitute any express or implied warranties
whatsoever.
PDF page 6
1 Product Overview
1.1 Brief Introduction
The E32-T Series (UART) module, developed by Chengdu Yibait Electronics Technology Co., Ltd. based on
SEMTECH's classic RF chip, features a transmit power of 20/30dBm. It supports multiple transmission modes and
operates in the 433MHz/868MHz/915MHz frequency bands. Utilizing LoRa spread spectrum technology, it provides
TTL-level output and is compatible with 3.3V IO port voltage.
The E32-T series employs the latest generation of LoRa spread spectrum technology. LoRa™ direct sequence spread
spectrum technology offers extended communication range, superior interference resistance, and robust confidentiality.
With a maximum transmit power of 30dBm, it incorporates a PA power amplifier and LNA low-noise amplifier to
enhance communication stability and extend transmission distance. Industrial-grade standards ensure reliability and
consistency. Currently in stable mass production, it is widely deployed in utility metering, IoT retrofits, smart home
applications, and other fields.
The eight modules shown below vary in power, packaging, and frequency bands. Detailed specifications are
provided in Section 2.1: E32-T Series Product Selection Comparison.
1.2 Features
Features next-generation LoRa spread-spectrum modulation technology for extended communication range and
enhanced interference resistance;
Supports multiple frequency bands including 433/868/915MHz (customizable);
Enables serial port firmware upgrades for simplified maintenance;
Supports dual HEX and AT command systems for flexible user selection;
Supports Forward Error Correction (FEC) for enhanced communication stability;
Supports Wake-on-Air (WoA) functionality, enabling ultra-low power consumption ideal for battery-powered
applications;
Supports point-to-point transmission and broadcast transmission;
Supports deep sleep mode;
Multi-level adjustable air transmission rates;
Parameters are preserved during power loss; the module resumes operation with preset parameters upon power-up;
Built-in watchdog automatically resets and restores operation in case of unexpected events.

PDF page 7
1.3 Application
Home security alarms and remote keyless entry;
Smart home and industrial sensors;
Wireless alarm security systems;
Building automation solutions;
Wireless industrial-grade remote controllers;
Healthcare products;
Advanced Metering Infrastructure (AMI).
2 Specification and parameter
2.1 E32-T Series Product Selection Comparison
Test
Frequency① Transmit Package Antenna
Type Model Distance③k Size mm
Hz Power②dBm Type Type④
m
IPEX-1/Stamp
E32-433T20S 410~441M 20 5 SMD 16*26
Hole
E32-
433MHz 410~441M 20 5 DIP 21*36 SMA-K
433T20D
Band
Module IPEX-1/Stamp
E32-433T30S 410~441M 30 8 SMD 40.5*25
Hole
E32-
410~441M 30 8 DIP 43*24 SMA-K
433T30D
IPEX-1/Stamp
E32-900T20S 862~930M 20 5 SMD 16*26
Hole
868/915 E32-
862~930M 20 5 DIP 21*36 SMA-K
MHz 900T20D
Band IPEX-1/Stamp
Module E32-900T30S 862~930M 30 8 SMD 40.5*25
Hole
E32-
862~930M 30 8 DIP 43*24 SMA-K
900T30D
Note:
(1) Carrier Frequency ①: Frequency band range supports user customization;
(2) Transmit Power ②: 20dBm = 100mW / 30dBm = 1000mW, tolerance range ±1dBm. Multi-level power adjustment
available. Refer to Sections 6 and 7 for detailed power levels;
(3) Test Distance③: Clear open space, airspeed 2.4kbps, antenna height 2 meters (for reference only; field testing
recommended);
(4) Antenna Configuration④: Equivalent impedance approximately 50Ω;
(5) Modules within the same frequency band can communicate with each other.
PDF page 8
2.2 Basic Parameters
E32-T Series 20dBm Low-Power Module Models: E32-433T20D, E32-433T20S, E32-900T20D, E32-900T20S;
E32-T Series 30dBm high-power module models are: E32-433T30D, E32-433T30S, E32-900T30D, E32-900T30S;
2.2.1 Basic Parameters
Conditions: Tc=25°C, VCC=5.0V, 433MHz/868MHz/915MHz
Parameters Description
Modulation
LoRa Modulation Technology
method
1.27mm pin pitch / 2.54mm pin header connectors; the pin pitch connectors are surface-mount
Interface
modules, while the pin headers are through-hole modules.
Communicatio
UART Serial Port (3.3V)
n Interface
Launch length 58 Bytes, maximum capacity per package; automatically splits into multiple packages when exceeded.
Packaging
SMD/DIP
method
Cache capacity 512Byte
Work Environment
Operating
-40℃~+85℃,Industrial-grade standards
Temperature
Operating
10~90%RH
Humidity
Storage
-40℃~+125℃
temperature
RF parameters
20dBm = 100mW, with multi-level power adjustment. For details, refer to Sections 6 and 7 of this
document.
Transmit Power
30dBm = 1000mW, with multi-level power adjustment. For details, refer to Sections 6 and 7 of this
document.
Operating 410 MHz to 441 MHz, supports custom frequency bands
frequency band 862 MHz to 930 MHz, supports customized frequency bands
Receiver -126dBm, data rate 2.4kbps@SF11, suitable for E32-T series 20dBm low-power modules
sensitivity -134dBm, data rate 2.4kbps@SF11, suitable for E32-T series 30dBm high-power modules
2.4 to 19.2 Kbps, with multi-level adjustable air interface rates. For details, refer to Sections 6 and 7
Air Speed
of this document.
Blocking
10dBm
power
Electrical Parameters
2.6–5.5V, 30dBm output module ≥5V, 20dBm output module ≥3.3V to ensure output power. Exceeding
Supply Voltage
5.5V will permanently burn out the module.
Communicatio
3.3V
n Level
Launch current 90–120mA, instantaneous power consumption @ 20dBm, suitable for E32-T series 20dBm low-
PDF page 9
Parameters Description
power modules
500–600mA, instantaneous power consumption @ 30dBm, suitable for E32-T series 30dBm high-
power modules
≈7mA, suitable for E32-T series 20dBm low-power modules
Receive current
≈14mA, suitable for E32-T series 30dBm high-power modules
Sleep current ≈2uA
3 Mechanical Dimensions and Pin Definitions
3.1 E32-433T20S & 900T20S Mechanical Dimensions and Pin Definitions
Pin
Pin Name Pin Orientation Pin Function
Number
1. Module reset pin. Low-level trigger for reset, requiring a pull-down
time exceeding 100μs;
1 RESET Input
2. Users are strongly advised to connect to a microcontroller for reset
and recovery in unexpected situations.
2 GND - Module Grounding
3 NC - Empty Foot (Please leave this space blank)
4 NC - Empty Foot (Please leave this blank)

PDF page 10
5 NC - Empty Foot (Please leave this blank)
Empty pins (programming pins; if possible, bring them out for easier
6 NC -
maintenance or firmware customization later)
Empty pins (programming pins; if possible, bring them out for easier
7 NC -
maintenance or firmware customization later)
8 GND - Module Grounding
11 GND - Module Grounding
Antenna Interface (High-Frequency Signal Output, 50-Ohm
12 ANT Outpu
Characteristic Impedance)
13 GND - Module Grounding
14 GND - Module Grounding
15 GND - Module Grounding
16 GND - Module Grounding
19 GND - Module Grounding
Input (Very weak In conjunction with M1, determines the module's four operating
20 M0
pull-up) modes (cannot be left floating).
Input (Very weak In conjunction with M0, determines the module's four operating
21 M1
pull-up) modes (cannot be left floating).
22 RXD Input 3.3V serial input connected to external TXD output pin;
23 TXD Output 3.3V serial port output connected to the external RXD output pin;
1. Indicates module operational status (may be left floating);
2. During normal operation, a low level on this pin indicates busy
status, while a high level indicates idle status;
3. It is not recommended to use this pin to drive external devices or
24 AUX Output
pull it low. Otherwise, if the AUX pin is continuously pulled low by an
external source during module power-up, the module may forcibly
enter upgrade mode and fail to operate normally. For detailed
information, please refer to Section 5.
Module Power Supply (Please refer to the Electrical Parameters
25 VCC -
section)
26 GND - Module Grounding
PDF page 11
3.2 E32-433T20D&900T20D Mechanical Dimensions and Pin Definitions
Pin Pin
Pin Orientation Pin Function
Number Name
Input (Very weak When paired with M1, determines the module's four operating modes
1 M0
pull-up) (cannot be left floating).
Input (Very weak When paired with M0, determines the module's four operating modes
2 M1
pull-up) (cannot be left floating).
3 RXD Input TTL serial input, connected to the external TXD output pin;
4 TXD Output TTL serial output connected to the external RXD input pin
1. Indicates module operational status (may be left floating);
2. During normal operation, a low level on this pin indicates busy
status, while a high level indicates idle status;
3. It is not recommended to use this pin to drive external devices or
5 AUX Output
pull it low. Otherwise, if the AUX pin is continuously pulled low by
an external source during module power-up, the module may forcibly
enter upgrade mode and fail to operate normally. For detailed
information, please refer to Section 5.
6 VCC Input Module Power Supply (Please refer to the Electrical Parameters

PDF page 12
section)
7 GND Input Module Grounding
Fixed
8 Fixed hole
hole
Fixed
9 Fixed hole
hole
Fixed
10 Fixed hole
hole
3.3 E32-433T30S&900T30S Mechanical Dimensions and Pin Definitions
Pin
Pin Name Pin Orientation Pin Function
Number
1 GND Input Module Grounding
Module Power Supply (Please refer to the Electrical Parameters
2 VCC Input
section)
1. Indicates module operational status (may be left floating)
3 AUX Output 2. During normal operation, a low level on this pin indicates busy
status, while a high level indicates idle status;

PDF page 13
3. It is not recommended to use this pin to drive external devices or
pull it low. Otherwise, if the AUX pin is continuously pulled low by
an external source during module power-up, the module may forcibly
enter upgrade mode and fail to operate normally. For detailed
information, please refer to Section 5.
4 TXD Output 3.3V serial port output, connected to the external RXD input pin;
5 RXD Input 3.3V serial input connected to external TXD output pin;
Input (Very weak In conjunction with M0, determines the module's four operating
6 M1
pull-up) modes (cannot be left floating).
Input (Very weak In conjunction with M1, determines the module's four operating
7 M0
pull-up) modes (cannot be left floating).
Antenna Interface (High-Frequency Signal Output, 50-Ohm
11 ANT Output
Characteristic Impedance)
12 GND - Grounded pin
13 GND - Grounded pin
14 GND - Grounded pin
Empty pins (programming pins; if possible, bring them out for easier
18 NC
maintenance or firmware customization later)
Empty pins (programming pins; if possible, bring them out for easier
19 NC
maintenance or firmware customization later)
20 NC Empty Foot (Please leave this space blank)
21 NC Empty Foot (Please leave this space blank)
1. Module reset pin. Low-level trigger initiates reset, requiring a hold
time exceeding 100μs.
22 RESET Input
2. Users are strongly advised to connect to a microcontroller for reset
and recovery in unexpected situations.
23 GND - Grounded pin
24 NC Empty Foot (Please leave this blank)
PDF page 14
3.4 E32-433T30D&900T30D Mechanical Dimensions and Pin Definitions
Pin Pin
Pin Orientation Pin Function
Number Name
Input (Very weak When paired with M1, determines the module's four operating modes
1 M0
pull-up) (cannot be left floating).
Input (Very weak When paired with M0, determines the module's four operating modes
2 M1
pull-up) (cannot be left floating).
3 RXD Input 3.3V serial input connected to the external TXD output pin;
4 TXD Output 3.3V serial port output, connected to the external RXD input pin;
1. Indicates module operational status (may be left floating);
2. During normal operation, a low level on this pin indicates busy status,
while a high level indicates idle status;
3. It is not recommended to use this pin to drive external devices or pull it
5 AUX Output
low. Otherwise, if the AUX pin is continuously pulled low by an external
source during module power-up, the module may forcibly enter upgrade
mode and fail to operate normally. For detailed information, please refer to
Section 5.
6 VCC Input Module Power Supply (Please refer to the Electrical Parameters section)
7 GND Input Module Grounding

PDF page 15
Fixed
8 - Fixed hole
hole
Fixed
9 - Fixed hole
hole
Fixed
10 - Fixed hole
hole
Fixed
11 - Fixed hole
hole
4 Recommended Connection Diagram
Serial
Notes
Number
The module features a 3.3V serial port and I/O pins. Users with 5V microcontrollers should consider level
1
conversion.
It is strongly recommended to connect the RESET pin to prevent unexpected malfunctions or other
2
abnormal conditions.
If you plan to add an external switch to the module's VCC, consider the leakage current of the external
3
microcontroller's serial port. Otherwise, the module cannot be turned off.
It is not recommended to use the AUX pin to drive external components, such as powering LEDs or
4 controlling relays. If continuously pulled low by an external source during power-up, it will not function
properly.
(Optional) Surface-mount modules may consider exposing the module's programming pins to facilitate
5
future maintenance or firmware customization.

PDF page 16
Serial
Notes
Number
(Optional) The module serial port may be extended with additional interfaces for easier maintenance
6
(supporting online upgrades via PC tools).
5 Detailed Functionality
In this section, pin 0 of M1/M0 represents a low level, while 1 represents a high level.
If using software switching mode, refer to Chapter 7 for the AT+MODE command.
5.1 Operating Mode
The module has four operating modes, set via pins M1 and M0. Details are shown in the table below:
Mode(0- M M
Model Introduction Note
3) 1 0
The receiving party
0 General
0 0 Serial port enabled, wireless enabled, transparent transmission must be Mode 0 or
Mode
Mode 1.
The receiver can be
Serial port enabled, wireless enabled; Mode 0
1 Wake The only difference from Mode 0: Before transmitting data packets, it The receiver can be
0 1
Mode automatically appends a wake-up code to wake up the receiver operating Mode 1
in Mode 2. The receiver can be
Mode 2
Transmitter must
2 Power be in Mode 1
Serial port reception is disabled. Wireless is in air wake mode. Upon
Saving 1 0 Transmission is not
receiving wireless data, enable the serial port to transmit data.
Mode permitted in this
mode
For detailed
specifications,
please refer to the
3 Sleep The module enters sleep mode and can receive parameter configuration
1 1 detailed
Mode commands.
explanation of
working
parameters.
5.1.1 Transmission mode in use: Mode 0 (M1 and M0 pins set to 0,0)
Type When M0 = 0 and M1 = 0, the module operates in Mode 0.
The module receives user data from the serial port and transmits wireless data packets with a length of 58
bytes. When the user input data reaches 58 bytes, the module initiates wireless transmission. At this point,
the user may continue inputting data for transmission. If the user needs to transmit less than 58 bytes, the
Transmit
module waits for 3 bytes. If no further user data is input, it assumes data termination and transmits all
accumulated data packets wirelessly. Upon receiving the first user data byte, the module outputs a low level
on the AUX pin. After loading all data into the RF chip and initiating transmission, the AUX pin outputs a
PDF page 17
high level. This indicates the final wireless data packet has begun transmission, allowing the user to continue
inputting data up to 512 bytes. Data packets transmitted in Mode 0 can only be received by receiver modules
operating in either Mode 0 or Mode 1.
The module continuously maintains its wireless reception capability, enabling it to receive data packets
transmitted from Mode 0 and Mode 1 devices.
Receive Upon receiving a data packet, the module outputs a low level on the AUX pin. After a 5ms delay, it begins
transmitting the wireless data via the serial port's TXD pin. Once all wireless data has been output through
the serial port, the module outputs a high level on the AUX pin.
5.1.1.1 Quick Start Guide for Transparent Transfer
What you see is what you get. Simply use Serial Port Assistant for mutual communication (all factory default
parameters are identical, and the transmission mode is transparent). An example scenario is as follows:
Figure 1: Schematic of Bidirectional Transmission and Reception
5.1.1.2 Quick Point-to-Point Transmission (Specify Destination Address and Channel)
Data transmission and reception follow a fixed format: destination address + destination channel + data. This
effectively minimizes interference. Detailed operational steps are as follows:

PDF page 18
Figure 2 Point-to-Point Transmission Schematic
Operating Procedure:
Step 1: Modify module parameters via the host computer:
Under configuration mode (set M1 and M0 pins to 1,1), modify the module address and channel. Change the
transmission mode from transparent to fixed-point transmission. Finally, write the parameters to complete the
modification.
Figure 3: Host Computer Interface
Step 2: Switch the module operating mode to normal mode: Edit Module A parameters to 000304AABBCC and
send to Module B. Similarly, Module B sends data as 000102AABBCC. (Data transmission format in fixed-point mode:
Destination address + Destination channel + Data).


PDF page 19
Figure 4 Data Transmission Diagram
5.1.1.3 Quick Guide to Broadcasting
Set Module A's address to 0xFFFF and channel to 0x04. When Module A transmits (in the same mode, transparent
transmission or fixed-point transmission), all receiving modules on channel 0x04 can receive the data, achieving a
broadcast effect.
Set Module A's address to 0xFFFF and channel to 0x04. When Module A operates as a receiver, it can receive all
data on channel 0x04, achieving monitoring functionality.
Figure 5 Point-to-Point Broadcast Transmission Diagram
Operating Procedure:
Step 1: Modify module parameters via the host computer:
In configuration mode (with M1 and M0 pins set to 1,1), modify the module address and channel. Change the
transmission mode from transparent to fixed-point transmission. Finally, write the parameters to complete the
modification.


PDF page 20
Figure 6: Host Computer Interface Diagram
Step 2: Switch the module operating mode to normal mode: Edit Module A parameters to FFFF04AABBCC and transmit
to Module B. Similarly, Module B transmits data as FFFF02AABBCC. (Data transmission format in point-to-point
broadcast mode: Broadcast address + Target channel + Data).
Figure 7 Data Transmission Diagram
5.1.2 Wake-up Mode, Mode 1 (M1, M0 pins set to 0,1)
Type When M0 = 1 and M1 = 0, the module operates in Mode 1.
The conditions for module startup packet transmission and AUX functions are identical to Mode 0. The only
difference is that the module automatically appends a wake-up code before each packet. The length of the
Transmit
wake-up code depends on the wake-up time set in the user parameters. The purpose of the wake-up code is
to wake up receiver modules operating in Mode 2. Therefore, data transmitted in Mode 1 can be received by
Modes 0, 1, and 2.
Receive Equivalent to Mode 0.

PDF page 21
5.1.3 Power-saving mode, Mode 2 (M1 and M0 pins set to 1 and 0)
Type When M0 = 0 and M1 = 1, the module operates in Mode 2.
The module is in sleep mode, and the serial port is disabled, preventing reception of serial data from an
Transmit
external MCU. Therefore, this mode does not support wireless transmission functionality.
In Mode 2, the transmitter must operate in Mode 1; it periodically monitors for wake-up codes. Upon
receiving a valid wake-up code, the module remains in continuous receive mode until the entire valid data
packet is acquired. Subsequently, the AUX pin outputs a low level. After a 5ms delay, the serial port is
activated to transmit the received wireless data via TXD. Upon completion, the AUX pin outputs a high level.
Receive
The wireless module then returns to its “Sleep - Listening” operational state (polling). By configuring
different wake-up times, the module exhibits varying reception response delays (maximum 2s) and average
power consumption (minimum 30μA). Users must strike a balance between communication latency and
average power consumption.
5.1.3.1 Quick Start Guide for Transparent Transfer
Based on the content in Sections 5.1.2 and 5.1.3, the detailed steps for module wake-up are as follows:
Step 1: Modify the operating mode via the M1 and M0 pins of the module. Set the A module pin to 0,1 for wake-up mode,
and set the B module pin to 1,0 for power-saving mode.
Step 2: After switching the module's operating mode: The transmitting module sends data to the receiving module, but the
receiving module cannot send data back to the transmitting module.
Figure 8 Data Transmission Diagram

PDF page 22
5.1.4 Sleep configuration mode in use, Mode 3 (M1, M0 pins set to 1,1)
Type When M0 = 1 and M1 = 1, the module operates in Mode 3.
Transmit Unable to transmit wireless data.
Receive Unable to receive wireless data.
Configu Sleep mode can be used for module parameter configuration. Utilize the serial port at 9600 baud, 8 data bits,
ration and 1 stop bit to set the module's operational parameters via specific command formats.
When transitioning from sleep mode to other modes, the module reconfigures its parameters. During this
Notice process, AUX remains low; upon completion, it outputs a high level. Therefore, users are advised to detect
the rising edge of AUX.
5.1.4.1 Quick Start Guide for Configuration Tools
The figure below shows the configuration host display interface. Users can switch to configuration mode via M0 or
M1 to quickly configure and read parameters on the host computer.
Within the configuration host, module addresses and frequency channels are displayed in decimal mode. For the valid
parameter ranges, refer to the specific parameters for different product models within the registers in Section 6.3.
Figure 9: Host Computer Interface

PDF page 23
5.1.5 Precautions for Using Work Modes
Serial
Notes
Number
Users can combine M1 and M0 into high or low levels to determine the module's operating mode. Two
GPIO pins on the MCU can be used to control mode switching;
If the module has serial data that has not yet been fully transmitted wirelessly, it can only enter a new
1 operating mode after transmission is complete;
If the module receives wireless data and then transmits data externally via the serial port, it must finish
transmitting before entering a new operating mode;
Mode switching is only effective when AUX is outputting 1; otherwise, the switch will be delayed.
When a user continuously inputs large amounts of data while simultaneously switching modes, the
2 mode-switching operation is ineffective. The module will process all user data before performing a new
mode detection.
When the module transitions from other modes to sleep mode, if any data remains unprocessed, the
module will complete processing of this data (including both received and transmitted data) before entering
sleep mode. This feature enables rapid sleep mode transition to conserve power. For example: When the
3 transmit module operates in Mode 0, if the user initiates serial data “12345”, it can immediately switch to
sleep mode without waiting for the AUX pin to become idle (high level). The user's main MCU can then
enter sleep mode immediately. The module will automatically transmit all user data wirelessly and enter
sleep mode within 1ms.
5.2 AUX Timing
5.2.1 Power-On Start Indicator
Conditions: Tc = 25°C, VCC = 5 V
Para
mete Description Typical value Unit
rs
The entire startup process after powering on the module's VCC takes time
T1 16 ms
(entering operational mode, user-accessible state).
After the module's VCC power supply is applied, the initial delay period begins
when AUX first pulls low. It does not immediately indicate a busy state (low
level) because the internal microcontroller also requires a certain amount of
startup time.
T2 Note: During the initial phase of T2, the AUX pin operates as an internally 5 ms
pulled-up input. If it detects an externally pulled-low signal lasting over 1 second
(e.g., via an external pull-down resistor or shorting to GND), the device will
forcibly enter upgrade mode. This prevents normal wireless data transmission,
reception, and configuration command processing. For further details, refer to the
firmware upgrade section.
PDF page 24
1 2 3 4 5 6 7 8 9 10 11 12 13
VCC
T1
AUX
T2
Figure 10 Power-Up Sequence Diagram
5.2.2 Serial Port Data Output Indicator
Conditions: Tc = 25°C, VCC = 5 V
Para
mete Description Typical value Unit
rs
After the module completes reception of the air data packet, the AUX pin pulls
T1 low to indicate to external users that the microcontroller is ready. It can also 3 ms
serve as a wake-up signal, suitable for certain low-power battery applications.
The module outputs the time interval between two consecutive packets of air
data.
Scenario 1: When the transmitter is transmitting data in an oversized packet loop
and the air data rate significantly exceeds the receiver's serial port rate, the serial
0
output data from the receiver module will exhibit packet sticking (T2=0). The
or
length of a single serial output may exceed the user-defined packet size. This is
T2 Tx ms
suitable for applications where Modbus reads multiple registers from a slave
(single packet
device and acknowledges responses.
airtime)
Scenario 2: The transmitter is transmitting oversized packets in a loop, but both
the air interface rate and serial baud rate are slow (e.g., default air interface 2.4
Mbps, serial 9600 baud). In this case, air transmission is time-consuming, so the
receiver outputs packets at the packet interval.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
AUX
TXD 0x01 0x02 n 0x01 n
T1 T2
Figure 11 Serial Port Data Output Timing Diagram
PDF page 25
5.2.3 Wireless Transmission Indicator
Tc = 25°C, VCC = 5 V
Para
mete Description Typical value Unit
rs
Internal buffer capacity of the module serial port (maximum single-transmission
data length). When the buffer contains data exceeding the user-defined packet
n 512 Byte
size (default 58 bytes), it will automatically segment the data for wireless
transmission.
AUX indicator delay time when the module receives serial data. The busy state
(pulled low) is only indicated after the module identifies and receives the first
T1 1 ms
byte of the serial data packet. Therefore, the delay time is related to the serial
baud rate (default 9600 bps).
Module Cache Idle State AUX Indicator Delay (Pull-High) Time
Scenario 1: When the data length transmitted to the module is shorter than the
packet length (default 58 bytes), At this point, T2 represents the serial port
reception frame break delay, with a default frame break time of 3 bytes
(dependent on the serial port baud rate, default 9600). Once the frame break
3
countdown ends, the AUX pin is immediately pulled high to indicate cache idle,
simultaneously triggering the air transmission process (under default conditions,
or
AUX does not indicate wireless transmission busy; refer to the AT+UAUX
T2 ms
command for additional settings).
Tx
(Transmission
Scenario 2: When the data length transmitted to the module exceeds the packet
time)
size, T2 represents the total airtime consumption (dependent on air interface
rate). During serial reception, once the packet size is reached, the air transmission
process is triggered immediately (LoRa air transmission is relatively time-
consuming). Subsequent cycles involve multiple packet transmissions (based on
the incoming data length) until all data in the receive buffer is fully transmitted.
Only then is the AUX pin pulled high to indicate buffer availability.
1 2 3 4 5 6 7 8 9 10 11 12 13
RXD 0x01 0x02 0x03 n-1 n
AUX
T1 T2
Figure 12 Wireless Transmission Timing Diagram
PDF page 26
5.2.4 Switch Mode
When switching between all modes, the AUX will indicate a busy state for the durations specified in the table below:
Original working mode Switch Mode T1 Switching Time (ms)
Transparent Mode 9~11
Sleep Mode Power Saving Mode 9~11
Wake Mode 9~11
Sleep Mode 9~11
Transparent Mode Power Saving Mode 9~11
Wake Mode 9~11
Sleep Mode 9~11
Power Saving Mode Transparent Mode 9~11
Wake Mode 9~11
Sleep Mode 9~11
Wake Mode Transparent Mode 9~11
Power Saving Mode 9~11
1 2 3 4 5 6 7 8 9 10 11 12 13
M0
M1
AUX
T1 T1 T1
Figure 13 Mode Switching Sequence Diagram
5.2.5 Notes
Serial
AUX Notes
Number
When the AUX output is low, it indicates that the module is busy and will not perform operating mode
1
detection at this time.
2 If AUX remains at a high level, the mode switch will take effect immediately.
When the user transitions from Mode 3 (Sleep Mode) to another mode or during the reset process, the
3
module will reset user parameters, during which the AUX output will be low.
PDF page 27
5.3 Serial Port Firmware Upgrade
If customers need to upgrade the firmware, they must locate the corresponding BIN file provided by the official source
and use the official PC software for the upgrade. Generally, users do not need to perform firmware upgrades; please
do not use the “AT+IAP” command.
The pins required for upgrading must be brought out (M1, M0, AUX, TXD, RXD, VCC, GND). Then, send the
“AT+IAP” command in configuration mode to enter upgrade mode. To exit IAP upgrade mode, keep the device
powered on and wait 60 seconds; the program will automatically exit. Otherwise, even after a reboot, the device will
continuously enter upgrade mode.
Upon entering upgrade mode, the baud rate automatically switches to 115200 and remains there until automatic exit.
Log output will be displayed during this period.
5.3.1 Quick Guide to Host Computer Upgrade
Enter configuration mode by changing M0 and M1 (Note: The baud rate in configuration mode is 9600);
Open the configuration host computer and select the Firmware Upgrade tab.
Open the official website configuration host computer, select Serial Port → Open Serial Port → Read Parameters →
Select Firmware Upgrade → Click Open File and choose the required upgrade firmware → Click Download.
Figure 14 Firmware Upgrade Interface

PDF page 28
6 Register Read/Write Control
6.1 Command Introduction
In sleep mode (Mode 3: M0=1, M1=1), the supported command list is as follows (when configured, only 9600 baud rate
and 8N1 format are supported):
Seria
l Command
Detailed Description
Num Format
ber
C0+
Send C0 + 5 bytes of operating parameters in hexadecimal format, totaling 6 bytes. Must be
1 Operating
transmitted consecutively (preserved during power loss).
Parameters
Send three C1 commands in hexadecimal format. The module will return the saved parameters.
2 C1+C1+C1
Commands must be sent consecutively.
C2+
Send C2 + 5 bytes of working parameters in hexadecimal format, totaling 6 bytes. Must be sent
3 Operating
consecutively (not retained after power loss).
Parameters
Send three C3 commands in hexadecimal format. The module will return version information.
4 C3+C3+C3 Commands must be sent consecutively. (It is recommended to use AT commands to read
version information. For detailed usage, refer to Chapter 7 of this document.)
Send three C4s in hexadecimal format; the module will generate a reset. The transmission must
5 C4+C4+C4
be continuous.
6.2 Reading of Operating Parameters
Command
Detailed Description
Format
In sleep mode (M0=1, M1=1), send the command (in HEX format) to the module's serial port: C1 C1
C1+C1+C1 C1.
The module will return its current configuration parameters, for example: C0 00 00 1A 06 44.
PDF page 29
6.3 Version Number Reading
Comman
Detailed Description
d Format
In sleep mode (M0=1, M1=1), send the command (in HEX format) to the module's serial port: C3 C3 C3.
The module will return its current configuration parameters, e.g.: C3 32 XX YY;
C3 denotes the command prefix, 32 represents the product model, XX indicates the version number, and
C3+C3+C YY signifies the interface format + maximum module power value (hexadecimal). TTL interface is 0x10,
3 RS232 is 0x40, and RS485 is 0x80.
It is recommended to use the command AT+DEVTYPE=? instead, which will retrieve the complete
product model.
6.4 Reset command
Comman
Detailed Description
d Format
In sleep mode (M0=1, M1=1), send the command (in HEX format) C4 C4 C4 to the module's serial port.
The module will perform a reset.
C4+C4+
During reset, the module conducts a self-test and outputs a low level on AUX. After reset completes, AUX
C4
outputs a high level, and the module resumes normal operation.
At this point, mode switching or issuing the next command is possible.
6.5 Register Function Reference Table
Bit
Address Name
bit 7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
00h HEAD Fixed Control Frame Header [7:0]
01h ADDH Mailing Address [15:8]
02h ADDL Mailing Address [7:0]
03h SPED Serial Port Parity Type Serial Port Baud Rate Wireless transmission rate [2:0]
[1:0] [2:0]
04h CHAN Channel Control [7:0]
05h OPTION Transmission Retain Air Wake-Up Period Forward Wireless transmission
Method [2:0] error power [1:0]
correction
Note: For reference on register software structure design, consult the E32-xxxTBL-SC series sample code (available in
the relevant download section of this page). See e32_demo.h for details.
PDF page 30
6.6 Register Specifications
Seria
l
Name Description Note
Num
ber
Must be 0xC0 or C2
C0: Set parameters are retained
HEA Fixed at 0xC0 or 0xC2, indicating that this frame data is a control
0 after power loss.
D command.
C2: Set parameters are not
retained after power loss.
ADD
1 High byte of module address (default 00H) 00H-FFH
H
ADD
2 Low byte of module address (default 00H) 00H-FFH
L
7 6 Serial Port Parity Bit
0 0 8N1(Default) The serial port modes of the
0 1 8O1 communicating parties may
1 0 8E1 differ.
1 1 8N1(Equivalent to 00)
5 4 3 TTL Serial Port Speed (bps)
0 0 0 The serial port baud rate is 1200
The baud rates of both
0 0 1 The serial port baud rate is 2400 communication parties may
0 1 0 The serial port baud rate is 4800 differ.
The serial port baud rate is 9600 The serial port baud rate is
0 1 1
(Default) unrelated to wireless
1 0 0 The serial port baud rate is 19200 transmission parameters and
1 0 1 The serial port baud rate is 38400 does not affect wireless
3 SPED transceiver characteristics.
1 1 0 The serial port baud rate is 57600
1 1 1 The serial port baud rate is 115200
2 1 0 Universal Wireless Air Rate(bps)
0 0 0 Air Rate 2.4k
The lower the air interface rate,
0 0 1 Air Rate 2.4k the greater the transmission
0 1 0 Air Rate 2.4k(Default) distance, the stronger the anti-
0 1 1 Air Rate 4.8k interference capability, and the
longer the transmission time.
1 0 0 Air Rate 9.6k The air interface transmission
1 0 1 Air Rate 19.2k rates of both communication
parties must be identical.
1 1 0 Air Rate 19.2k
1 1 1 Air Rate 19.2k
General Model
7 6 5 Reserve unused Write 0
Communication channel
CHA 400 MHz band: 00H-1FH,
4 4–0, corresponding to (410MHz + CHAN * 1MHz), default 17H
N corresponding to 410–441 MHz
(433MHz) (for 400MHz band) 900 MHz band: 00H-45H,
4–0, corresponding to (862MHz + CHAN * 1MHz), default 06H corresponding to 862–930 MHz
(868MHz) (for 900MHz band)
Enable Bit for Fixed Transmission(Similar to When set to 1, the first three
7
OPTI MODBUS) bytes of each user data frame
5
ON 0 Transparent Transfer Mode serve as the high address, low
1 Point-to-Point Transmission Mode address, and channel. During
PDF page 31
transmission, the module
changes its own address and
channel; upon completion, it
reverts to the original settings.
6 Retain
5 4 3 Wireless Wake-Up Time Both transmit and receive
0 0 0 250ms(Default) modules operate in Mode 0,
0 0 1 500ms rendering this delay time
0 1 0 750ms invalid and allowing any value.
0 1 1 1000ms The transmitter operates in
1 0 0 1250ms Mode 1, continuously
1 0 1 1500ms transmitting the corresponding
call code duration.
1 1 0 1750ms
The receiver operates in Mode
2, where this time represents
the receiver's monitoring
1 1 1 2000ms interval (wireless wake-up),
capable of receiving only data
from transmitters operating in
Mode 1.
2 FEC Switch After disabling FEC, the actual
0 Disable FEC error correction data transmission rate
increases, but interference
resistance weakens and the
effective distance decreases.
Please select based on your
1 Enable FEC error correction (default) specific application
requirements.
Both communication parties
must either enable or disable
FEC.
Transmit Power (Approximate Value) The external power supply
1 0 E32-T Series 30dBm E32-T Series 20dBm must provide an output current
Module Module capacity of 250mA or higher,
0 0 30dBm(Default) 20dBm(Default) with power supply ripple less
than 100mV.
0 1 27dBm 17dBm
1 0 24dBm 14dBm Using lower power transmitters
is not recommended, as their
1 1 21dBm 10dBm
power supply efficiency is low.
Example (meaning of byte 3 “SPED”):
Binary bits of this byte 7 6 5 4 3 2 1 0
Specific value (user-
0 0 0 1 1 0 1 0
configurable)
Serial Port Parity The serial port baud rate is
Representative meaning Airborne speed is 2.4k
Bit 8N1 9600.
Corresponding hexadecimal 1 A
PDF page 32
6.7 Register factory default parameters
Factory default parameter values for the 433MHz band: C0 00 00 1A 17 04
Model
Factory default parameter values for the 900MHz band: C0 00 00 1A 06 04
Chann Serial Port Transmit
Module model Frequency Address Air rate Baud rate
el Format Power
E32-433T20S
433.125MHz 0x0000 0x17 2.4kbps 9600 8N1 20dbm
E32-433T20D
E32-433T30S
433.125MHz 0x0000 0x17 2.4kbps 9600 8N1 30dbm
E32-433T30D
E32-900T20S
868.125MHz 0x0000 0x12 2.4kbps 9600 8N1 20dbm
E32-900T20D
E32-900T30S
868.125MHz 0x0000 0x6 2.4kbps 9600 8N1 30dbm
E32-900T30D
7 AT command
Configuring parameters or querying using AT commands requires entering configuration mode (configuration mode
serial port is fixed at 9600 8N1);
For software versions (7459-0-18) and earlier, users do not need to add a carriage return/line feed character at the end
of AT commands.
Software versions (7459-0-19) and later automatically recognize the carriage return/line feed at the end of user AT
commands; recognition remains unaffected even without the return/feed.
AT command recognition or execution failures will respond with “=ERR”.
When input parameters exceed the valid range, restrictions will apply. Do not allow parameters to exceed the range
to avoid unexpected conditions.
7.1 General Command
7.1.1 AT+RESET Software Reset
Command
AT+RESET
Format
Execution Send: AT+RESET
Example Response: =OK
Software versions (7459-0-19) and earlier will not respond with “=OK”.
Feature Software versions (7459-0-20) and later will respond with “=OK”.
Description The actual reset process will only begin after the “=OK” response. Users should wait approximately
30ms before proceeding with the next operation.
PDF page 33
7.1.2 AT+DEFAULT Restore factory settings
Command
AT+DEFAULT
Format
Execution Send: AT+DEFAULT
Example Response: =OK
Feature
After acknowledging (=OK), the system will perform parameter restoration and initiate a restart process.
Descriptio
Please wait approximately 30 milliseconds before proceeding with the next operation.
n
7.1.3 AT+DEVTYPE Query Product Model
Command AT+DEVTYPE=?
Format
Execution Send: AT+DEVTYPE=?
Example Response: DEVTYPE=E32-433T30S
Feature Product Series: E32
Descriptio Operating Frequency Band: 433 (433/900)
n Maximum Power: 30 (20/30/33)
7.1.4 AT+FWCODE Query Software Version
Command AT+FWCODE=?
Format
Execution Send:AT+FWCODE=?
Example Response:FWCODE=7459-0-20
Feature Major Version: 7459
Descriptio Branch Number: 0
n Minor Version: 20 (increments starting from 10)
PDF page 34
7.1.5 AT+SWITCH Software Switching Mode Enable
Comman AT+SWITCH=<on_off>
d Format
Setup Send:AT+SWITCH=0
Example Response:=OK
Query Send:AT+SWITCH=?
Example Response:AT+SWITCH=0
Paramete <on_off>: Switch
r 0 Off (default)
Descripti 1 On
on
Feature Factory default is disabled. Use the M0M1 pin to switch operating modes (hard switch).
Descripti When enabled, the M0M1 pin remains functional. The last triggered switch (hard or soft) takes precedence.
on After enabling, restart the system for it to take effect.
When enabled, use AT+MODE to specify the operating mode (soft switch). Each soft switch immediately
saves the operating mode number.
When enabled, for software versions 7459-0-18 and earlier, the M0M1 hardware mode becomes the initial
operating mode after power-cycle restart.
When enabled, for software versions 7459-0-19 and later, the last soft-switch saved mode number becomes
the initial operating mode after power-cycle restart.
When disabled, the M0M1 hardware mode becomes the initial operating mode after power-cycle restart.
7.1.6 AT+MODE Software Mode Switching
Comman AT+MODE=<mode>
d Format
Setup Send:AT+MODE=0
Example Response:AT+MODE=0
Query Send:AT+MODE=?
Example Response:AT+MODE=0
Paramete <mode>: Operating Mode Number
r 0 Transmission Mode
Descripti 1 Wake-on-Radio Transmission Mode (WOR Tx)
on 2 Wake-on-Radio Reception Mode (WOR Rx/Power-Saving Mode)
3 Sleep and Configuration Mode
Feature Must be enabled via AT+SWITCH before use
Descripti Available in any operating mode
on Actual mode switching commences only after acknowledgment (=OK); users should wait approximately
15ms before proceeding
Refer to AT+SWITCH feature documentation
PDF page 35
7.1.7 AT+UAUX Wireless AUX Indicator Enable
Comman AT+UAUX=<on_off>
d Format
Configur Send:AT+UAUX=0
ation Response:=OK
Example
Query Send:AT+UAUX=?
Example Response:AT+UAUX=0
Paramete <on_off>: Switch
r 0 Off (default)
Descripti 1 On
on
Feature Software version (7459-0-18) and earlier do not support this command, and by default AUX does not
Descripti indicate the wireless transmission process (does not pull low during transmission).
on Software version (7459-0-19) and later are disabled by default. When enabled, AUX will pull low to
indicate wireless transmission during transmission.
7.1.8 AT+ADDR Communication Address (Matching Filter)
Comman AT+ADDR=<address>
d Format
Configur Send:AT+ADDR=0
ation Response:=OK
Example
Query Send:AT+ADDR=?
Example Response:AT+ADDR=0
Paramete <address> :Mailing Address 0 - 65535
r
Descripti
on
Feature Default address 0
Descripti The address is not an RF characteristic but merely an identifier carried within the packet, assisting the
on receiving software logic in determining whether to perform matching and filtering.
Broadcast address 65535. When acting as a receiver, it can receive data sent from any address on the same
channel (unfiltered). When acting as a sender, the transmitted packet carries the broadcast address, so
the recipient will not filter it either (broadcast data).
PDF page 36
7.1.9 AT+CHANNEL Communication Channel (Carrier Frequency)
Comman AT+CHANNEL=<ch>
d Format
Configura Send:AT+CHANNEL=0
tion Response:=OK
Example
Query Send:AT+CHANNEL=?
Example Response:AT+CHANNEL=0
Parameter <ch> :Communication Channel 0 - 31 <ch> :Communication Channel 0 - 69
Descripti E32-433T30D、E32-433T30S、E32-433T20D、 E32-900T30D、E32-900T30S、E32-900T20D、
on E32-433T20S E32-900T20S
Feature Product channel ranges differ across frequency bands; please note the distinctions.
Descripti For the 433 MHz band, the actual carrier frequency corresponds to: 410 MHz + channel frequency × 1
on MHz
For the 933 MHz band, the actual carrier frequency corresponds to: 862 MHz + channel frequency × 1
MHz
7.1.10 AT+UART Serial Port Baud Rate and Parity
Comman AT+UART=<baud>,<parity>
d Format
Configur Send:AT+UART=3,0
ation Response:=OK
Example
Query Send:AT+UART=?
Example Response:AT+UART=3,0
Paramete <baud> : Serial Port Baud Rate
r 0 1200bps
Descripti 1 2400bps
on 2 4800bps
3 9600bps (default)
4 19200bps
5 38400bps
6 57600bps
7 115200bps
<parity> :Serial Port Parity Type
0 No parity None (default)
1 Odd parity Odd
2 Even parity Even
Feature In configuration mode (M0M1 Mode 3), force fixed baud rate 9600, 8N1.
Descripti Changes take effect after switching operating modes.
on
PDF page 37
7.1.11 AT+URXT Serial Port Frame Disconnection Condition
Comman AT+URXT=<byte>
d Format
Configur Send:AT+URXT=3
ation Response:=OK
Example
Query Send:AT+URXT=?
Example Response:AT+URXT=3
Paramete <byte> :ByteTime 1 - 255
r
Descripti
on
Feature By default, serial port frame break processing is handled based on a 3-byte timeout.
Descripti The timeout duration varies by baud rate (measured in bytes). At 9600 baud, it is approximately 1
on millisecond per byte; at 115200 baud, it is approximately 100 microseconds per byte.
Some customers experience discontinuous data transmission from external microcontroller serial ports to
the module (e.g., due to RTOS task interruptions). When data exceeds the module's configured byte
time window, it is treated as a frame break and manifests as packet fragmentation at the receiving end.
7.1.12 AT+RATE Wireless Transmission Rate
Command AT+RATE=<rate>
Format
Configura Send:AT+RATE=2
tion Response:=OK
Example
Query Send:AT+UART=?
Example Response:AT+UART=2
Parameter <rate> :Air rate
Descriptio 0 2.4Kbps
n 1 2.4Kbps
2 2.4Kbps (Default)
3 4.8Kbps
4 9.6Kbps
5 19.2Kbps
6 19.2Kbps
7 19.2Kbps
Feature The higher the airborne speed, the lower the communication delay (shorter transmission time), but the
Descriptio poorer the reception sensitivity (shorter communication range).
n
PDF page 38
7.1.13 AT+TRANS Wireless Transmission Mode (Transparent/Fixed Point)
Command AT+TRANS=<mode>
Format
Configura Send:AT+TRANS=0
tion Response:=OK
Example
Query Send:AT+TRANS=?
Example Response:AT+TRANS=0
Parameter <mode> :Transmission Method
Descriptio 0 Transparent Transfer (Default)
n 1 Point-to-point transmission
Feature Point-to-point transmission applies special processing to the first three bytes of user input data. The first
Descriptio and second bytes are identified as the target communication address, while the third byte identifies the
n target communication channel (automatically switching channels).
After completing data transmission, point-to-point transmission automatically switches back to the
original channel.
7.1.14 AT+WTIME Wake-on-Air Period
Command AT+WTIME=<timeout>
Format
Configurati Send:AT+WTIME=0
on Example Response:=OK
Query Send:AT+WTIME=?
Example Response:AT+WTIME=0
Parameter <timeout> :Sleep time
Description 0 250ms (Default)
1 500ms
2 750ms
3 1000ms
4 1250ms
5 1500ms
6 1750ms
7 2000ms
Feature The longer the air wake-up receiver sleep time, the lower the average power consumption, but the greater
Description the communication delay.
Software version (7459-0-13) and earlier do not support this command. Please use the HEX command
to set the register instead.
PDF page 39
7.1.15 AT+FEC Forward Error Correction
Comman AT+FEC=<on_off>
d Format
Configur Send:AT+FEC=0
ation Response:=OK
Example
Query Send:AT+FEC=?
Example Response:=OK
Paramete <on_off> :Switch
r 0 Close
Descripti 1 Enable (Default)
on
Feature After disabling FEC, the actual data transmission rate increases, but interference resistance weakens
Descripti and the effective distance may decrease. Please select based on your specific application.
on Both communication parties must either enable or disable FEC.
7.1.16 AT+POWER Power Tiering
Comman AT+POWER=<Power>
d Format
Configur Send:AT+POWER=0
ation Response:AT+POWER=0
Example
Query Send:AT+POWER=?
Example Response:AT+POWER=0
Paramete <Power> :Power <Power> :Power
r E32-433T30S、E32-433T30D、E32-900T30D、 E32-433T20S、E32-433T20D、E32-900T20D、
Descripti E32-900T30S E32-900T20S
on
0 30dBm (Default) 0 20dBm (Default)
1 27dBm 1 17dBm
2 24dBm 2 14dBm
3 21dBm 3 10dBm
Feature -
Descripti
on
PDF page 40
7.2 Signaling Testing (Certification)
7.2.1 Test Command Declaration
The AT command testing section is intended solely for auxiliary use during product certification processes (e.g., CE,
FCC certification, etc.). Do not use it for any other purposes.
EBYTE assumes no liability for damages resulting from failure to comply with relevant operational or design
specifications. EBYTE strives to ensure the completeness, accuracy, and timeliness of features under development, but
does not exclude the possibility of errors or omissions in such features. Unless otherwise agreed upon, no implied or
statutory warranties are provided for the use of features under development. To the maximum extent permitted by applicable
law, EBYTE shall not be liable for any damages incurred from using features under development, regardless of whether
such damages were foreseeable.
7.2.2 Test Command Reference
For detailed documentation on command operations, please contact our sales channels through EBYTE.
AT Command Function Overview
AT+FPOWER Fine-tuning of transmit power
AT+XCAP Crystal Oscillator Calibration
Modifying LoRa Modulation Parameters (SF Spread Factor, BW Transmission Bandwidth, CR
AT+ULORAM
Coding Rate)
AT+OPTIMIZE Low-Rate Optimization Option
AT+UFREQ Carrier Frequency Adjustment (Starting Frequency Point, Channel Spacing)
AT+SWAVE Fixed-frequency continuous single-carrier transmission
AT+MWAVE Fixed-frequency continuous modulation wave transmission
AT+TFHSS Frequency-hopping modulated wave transmission
AT+DUTYTX Fixed-frequency continuous single carrier/modulation wave duty cycle transmission
PDF page 41
8 Hardware Design
It is recommended to power this module using a DC regulated power supply with minimal ripple coefficient, and
ensure the module is reliably grounded.
Please note the correct connection of the power supply's positive and negative terminals; reverse polarity may cause
permanent damage to the module.
Check the power supply to ensure it operates within the recommended voltage range; exceeding the maximum value
may cause permanent damage to the module.
Verify power supply stability; voltage must not fluctuate significantly or frequently.
When designing the power circuit for the module, it is often recommended to maintain a margin of at least 30% to
ensure long-term stable operation of the entire system.
Position the module as far as possible from power supplies, transformers, high-frequency traces, and other sources of
significant electromagnetic interference;
High-frequency digital traces, high-frequency analog traces, and power traces must avoid routing beneath the module.
If routing beneath the module is unavoidable (assuming the module is soldered to the Top Layer), place a copper
ground plane (fully copper-clad and properly grounded) on the Top Layer where the module contacts the board.
Routing must be positioned close to the module's digital section and placed on the Bottom Layer;
If the module is soldered or placed on the Top Layer, routing traces arbitrarily on the Bottom Layer or other layers is
incorrect and will adversely affect the module's spurious emissions and reception sensitivity to varying degrees;
Components emitting significant electromagnetic interference near the module will also severely degrade its
performance. Depending on the interference strength, maintain an appropriate distance from the module. Where
feasible, implement suitable isolation and shielding;
If high-interference traces (high-frequency digital, high-frequency analog, power lines) exist near the module,
performance will be severely degraded. Depending on interference intensity, maintain adequate distance from the
module. Where feasible, implement appropriate isolation and shielding.
Antenna mounting significantly impacts module performance. Ensure the antenna is exposed and ideally oriented
vertically upward.
When installing the module inside an enclosure, use a high-quality antenna extension cable to route the antenna
externally.
Never install the antenna inside a metal enclosure, as this will drastically reduce transmission range.
9 Frequently Asked Questions
9.1 Transmission distance is not ideal
When direct line-of-sight obstructions exist, communication distance will correspondingly decrease;
Temperature, humidity, and co-channel interference can increase packet loss rates;
Ground absorption and reflection of radio waves result in poorer performance during ground-level testing;
Seawater possesses extremely strong radio wave absorption capabilities, leading to poor testing results near the coast;
PDF page 42
Signal attenuation becomes severe when metal objects are present near the antenna or when the module is housed in
a metal enclosure;
Incorrect power register settings or excessively high air interface rate (higher air interface rate reduces communication
distance);
Power supply voltage below recommended levels at room temperature; lower voltage results in reduced transmit
power;
Use of antennas poorly matched to the module or antennas with inherent quality issues.
9.2 The module is vulnerable
Check the power supply to ensure it falls within the recommended voltage range. Exceeding the maximum voltage
may cause permanent damage to the module.
Verify power supply stability; voltage must not fluctuate significantly or frequently.
Ensure anti-static precautions during installation and operation, as high-frequency components are sensitive to static
electricity.
Maintain appropriate humidity levels during installation and operation, as certain components are moisture-sensitive.
Unless specifically required, avoid operating in excessively high or low temperatures.
9.3 The error rate is too high
Interference from nearby signals operating on the same frequency may occur. Move away from the interference source
or modify the frequency/channel to avoid interference.
Poor power supply quality may also cause garbled data. Ensure the power supply is reliable.
Extension cables or feeders of inferior quality or excessive length can also lead to elevated error rates.
9.4 Antenna Selection
Enable both the IPEX interface and the stamp hole interface simultaneously. Either the IPEX interface or the stamp hole
interface may be selected as needed.

PDF page 43
10 Welding Work Instructions
10.1 Reflow Soldering Temperature
Reflow Soldering Profile Characteristics Lead-based assembly Lead-Free Assembly
process Process
Lowest temperature
100℃ 150℃
(Tsmin)
Preheat/Keep Warm
Maximum temperature
150℃ 200℃
(Tsmax)
Time(Tsmin~Tsmin) 60–120 seconds 60-120 seconds
Temperature rise slope(TL~Tp) 3°C/s, maximum value 3°C/s, maximum value
Liquid phase temperature(TL) 183℃ 217℃
Hold time above TL 60~90 seconds 60~90 seconds
Users must not exceed the Users must not exceed the
temperature indicated on temperature indicated on
Peak Package Temperature Tp
the product's “Moisture the product's moisture
Sensitivity” label. sensitivity label.
Within the specified classification temperature (Tc) and time
20 seconds 30 seconds
(Tp) of 5°C, see the figure below.
Cooling slope(Tp~TL) 6°C/s, maximum value 6°C/s, maximum value
Time from room temperature to peak temperature 6 minutes, maximum 8 minutes, maximum
※The tolerance for the peak temperature (Tp) of the temperature curve is defined as the user's upper limit.
PDF page 44
10.2 Reflow Soldering Profile Chart
11 Antenna Guide
11.1 Antenna Recommendation
Antennas play a crucial role in communication processes, and substandard antennas can significantly impact
communication systems. Therefore, our company recommends certain antennas as compatible accessories for our wireless
modules, offering superior performance at a reasonable price.
Frequenc Interfa Height Feeder
Product Model Type Gain(dBi) Features
y(Hz) ce (mm) (cm)
Rubber Ultra-short straight-type
TX433-JZG-6 433M SMA-J 2.5 62 -
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX433-JW-5 433M SMA-J 2.0 50 -
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX433-JWG-7 433M SMA-J 2.5 75 -
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX433-JK-11 433M SMA-J 2.5 110 -
antenna omnidirectional antenna

PDF page 45
Frequenc Interfa Height Feeder
Product Model Type Gain(dBi) Features
y(Hz) ce (mm) (cm)
Suction
Compact Suction Cup
TX433-XPL-100 Cup 433M SMA-J 3.5 185 100
Antenna, Cost-Effective
Antenna
Suction
Neutral-point suction cup
TX433-XP-200 Cup 433M SMA-J 4.0 190 200
antenna, low loss
Antenna
Suction
Large suction cup
TX433-XPH-300 Cup 433M SMA-J 6.0 965 300
antenna, high gain
Antenna
Rubber Ultra-short straight-type
TX490-JZ-5 470/490M SMA-J 2.0 50 -
antenna omnidirectional antenna
Suction
Compact Suction Cup
TX490-XPL-100 Cup 470/490M SMA-J 3.5 120 100
Antenna, Cost-Effective
Antenna
Rubber Flexible rubber rod,
TX868-JKS-IPX20 868M IPEX-1 3.0 197 200
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX868-JZLW-15 868M IPEX-1 3.0 165 150
antenna omnidirectional antenna
Suction
Compact Suction Cup
TX868-XPL-100 Cup 868M SMA-J 3.5 290 100
Antenna, Cost-Effective
Antenna
Rubber Flexible rubber rod,
TX868-JKD-20 868M SMA-J 3.0 170 -
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX915-JKS-IPX20 915M IPEX-1 3.0 197 200
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX915-JZLW-15 915M IPEX-1 3.0 155 150
antenna omnidirectional antenna
Rubber Flexible rubber rod,
TX915-JKD-20 915M SMA-J 3.5 200 -
antenna omnidirectional antenna
Suction
Compact Suction Cup
TX915-XPL-100 Cup 915M SMA-J 3.5 260 100
Antenna, Cost-Effective
Antenna
PDF page 46
12 Bulk Packaging Method
12.1 E32-433T20S & E32-900T20S Bulk Packaging Method

PDF page 47
13.2 Bulk Packaging Method for E32-433T20D(30D) & E32-900T20D(30D)
13.3 E32-433T30S & E32-900T30S Bulk Packaging Method


PDF page 48
Revision history
Version Date Description Issued by
1.0 2023-10-25 Initial Version Hao
1.1 2024-6-7 Content Correction Hao
1.2 2024-8-30 Corrected pin descriptions Hao
1.3 2024-12-17 Revised sensitivity specifications Hao
1.4 2024-12-26 Removed certification details Lei
1.5 2025-10-23 Model consolidation and content restoration Hao
1.6 2026-1-16 Content Correction Hao
1.7 2026-5-29 Content Correction Hao
1.8 2026-9-2 Content Correction Hao
About us
Technical support: support@cdebyte.com
Documents and RF Setting download link: https://www.cdebyte.com
Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com
------------------------------------------------------------------------------------------------------------
Web: https://www.cdebyte.com
Address: B5 Mould Industrial Park, 199# Xiqu Ave, High tech Zone, Chengdu, Sichuan, China

Figures and diagrams from the PDF
Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.
Use this datasheet from any agent
Send the page, markdown, chunks, or search endpoint to ChatGPT, Claude, embedr-app, or your own tooling.