Datasheet docs

{ "mpn": "INA219A" }

INA219A

Zero-Drift, Bidirectional Current/Power Monitor With I²C Interface

Sensor

INA219 Zerø-Drift, Bidirectional Current/Power Monitor With I2C Interface

1 Features

1• Senses Bus Voltages from 0 to 26 V

• Reports Current, Voltage, and Power

• 16 Programmable Addresses

• High Accuracy: 0.5% (Maximum) Over Temperature (INA219B)

• Filtering Options

• Calibration Registers

• SOT23-8 and SOIC-8 Packages

2 Applications

• Servers

• Telecom Equipment

• Notebook Computers

• Power Management

• Battery Chargers

• Welding Equipment

• Power Supplies

• Test Equipment

3 Description

The INA219 is a current shunt and power monitor with an I2C- or SMBUS-compatible interface. The device monitors both shunt voltage drop and bus supply voltage, with programmable conversion times and filtering. A programmable calibration value, combined with an internal multiplier, enables direct readouts of current in amperes. An additional multiplying register calculates power in watts. The I2C- or SMBUS-compatible interface features 16 programmable addresses.

The INA219 is available in two grades: A and B. The B grade version has higher accuracy and higher precision specifications.

The INA219 senses across shunts on buses that can vary from 0 to 26 V. The device uses a single 3- to 5.5-V supply, drawing a maximum of 1 mA of supply current. The INA219 operates from –40°C to 125°C.

Device Information(1)

PART NUMBERPACKAGEBODY SIZE (NOM)
INA219SOIC (8)3.91 mm × 4.90 mm
SOT-23 (8)1.63 mm × 2.90 mm

(1) For all available packages, see the orderable addendum at the end of the data sheet.

Simplified Schematic

Table of Contents

1 Features.... 1
2 Applications.... 1
3 Description.... 1
4 Revision History.... 2
5 Related Products.... 3
6 Pin Configuration and Functions.... 3
7 Specifications.... 4
7.1 Absolute Maximum Ratings.... 4
7.2 ESD Ratings.... 4
7.3 Recommended Operating Conditions.... 4
7.4 Thermal Information.... 4
7.5 Electrical Characteristics:.... 5
7.6 Bus Timing Diagram Definitions.... 6
7.7 Typical Characteristics.... 7
8 Detailed Description.... 9
8.1 Overview.... 9
8.2 Functional Block Diagram.... 9

8.3 Feature Description.... 9
8.4 Device Functional Modes.... 11
8.5 Programming.... 12
8.6 Register Maps.... 18

9 Application and Implementation.... 25
9.1 Application Information.... 25
9.2 Typical Application.... 25

10 Power Supply Recommendations.... 27
11 Layout.... 27
11.1 Layout Guidelines.... 27
11.2 Layout Example.... 27

12 Device and Documentation Support.... 28
12.1 Community Resources.... 28
12.2 Trademarks.... 28
12.3 Electrostatic Discharge Caution.... 28
12.4 Glossary.... 28

13 Mechanical, Packaging, and Orderable Information.... 28

4 Revision History

NOTE: Page numbers for previous revisions may differ from page numbers in the current version.

Changes from Revision F (September 2011) to Revision G Page

  • Added ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section .... 1
  • Updated Bus Timing Diagram Definitions table. I²C timing table values were previously based on simulation and not characterized .... 6
    Changes from Revision E (September 2010) to Revision F Page
  • Changed step 5 and step 6 values in Table 8.... 26
    Changes from Revision D (September 2010) to Revision E Page
  • Updated Packaging Information table .... 3

5 Related Products

DEVICEDESCRIPTION
INA209Current/power monitor with watchdog, peak-hold, and fast comparator functions
INA210, INA211, INA212, INA213, INA214Zerø-drift, low-cost, analog current shunt monitor series in small package

6 Pin Configuration and Functions

DCN Package8-Pin SOT-23Top View
IN+18A1
IN-27A0
GND36SDA
VS45SCL

Pin Functions

PINI/ODESCRIPTION
NAMESOT-23SOIC
IN+18Analog InputPositive differential shunt voltage. Connect to positive side of shunt resistor.
IN-27Analog InputNegative differential shunt voltage. Connect to negative side of shunt resistor. Bus voltage is measured from this pin to ground.
GND36AnalogGround
$V_S$ 45AnalogPower supply, 3 to 5.5 V
SCL54Digital InputSerial bus clock line
SDA63Digital I/OSerial bus data line
A072Digital InputAddress pin. Table 1 shows pin settings and corresponding addresses.
A181Digital InputAddress pin. Table 1 shows pin settings and corresponding addresses.

7 Specifications

7.1 Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)

MINMAXUNIT
$V_S$ Supply voltage6V
Analog Inputs IN+, IN-Differential ( $V_{IN+} - V_{IN-}$ ) (2)-2626V
Common-mode( $V_{IN+} + V_{IN-}$ ) / 2-0.326V
SDAGND - 0.36V
SCLGND - 0.3 $V_S + 0.3$ V
Input current into any pin5mA
Open-drain digital output current10mA
Operating temperature-40125°C
$T_J$ Junction temperature150°C
$T_{stg}$ Storage temperature-65150°C

(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability

(2) $\vee _ { \vert N \vert }$ and $V _ { \vert N - }$ may have a differential voltage of –26 to 26 V; however, the voltage at these pins must not exceed the range –0.3 to 26 V.

7.2 ESD Ratings

VALUEUNIT
$V_{(ESD)}$ Electrostatic dischargeHuman body model (HBM), per ANSI/ESDA/JEDEC JS-001, all pins $^{(1)}$ ±4000V
Charged device model (CDM), per JEDEC specification JESD22-C101, all pins $^{(2)}$ ±750
Machine Model (MM)±200

(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.

7.3 Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)

MINNOMMAXUNIT
$V_{CM}$ 12V
$V_S$ 3.3V
$T_A$ -2585°C

7.4 Thermal Information

THERMAL METRIC(1)INA219UNIT
D (SOIC)DCN (SOT)
8 PINS8 PINS
$R_{\theta JA}$ Junction-to-ambient thermal resistance111.3135.4°C/W
$R_{\theta JC(top)}$ Junction-to-case (top) thermal resistance55.968.1°C/W
$R_{\theta JB}$ Junction-to-board thermal resistance5248.9°C/W
$\psi_{JT}$ Junction-to-top characterization parameter10.79.9°C/W
$\psi_{JB}$ Junction-to-board characterization parameter51.548.4°C/W
$R_{\theta JC(bot)}$ Junction-to-case (bottom) thermal resistanceN/AN/A°C/W

(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953.

7.5 Electrical Characteristics:

At TA=25°C, VS=3.3 V, VIN+=12V, VSHUNT=(VIN+-VIN-)=32 mV, PGA=/1, and BRNG(1)=1, unless otherwise noted.
PARAMETERTEST CONDITIONSINA219AINA219BUNIT
MINTYPMAXMINTYPMAX
INPUT
VSHUNTFull-scale current sense (input) voltage rangePGA =/10±400±40mV
PGA =/20±800±80mV
PGA =/40±1600±160mV
PGA =/80±3200±320mV
Bus voltage (input voltage) range(2)BRNG = 1032032V
BRNG = 0016016V
CMRRCommon-mode rejectionVIN+=0 to 26 V100120100120dB
VosOffset voltage, RTI(3)vs TemperaturePGA =/1±10±100±10±50(4)μV
PGA =/2±20±125±20±75(4)μV
PGA =/4±30±150±30±75(4)μV
PGA =/8±40±200±40±100(4)μV
TA=-25°C to 85°C0.10.1μV/°C
PSRRvs Power SupplyVS=3 to 5.5 V1010μV/V
Current sense gain errorvs Temperature±40±40m%
TA=-25°C to 85°C11m%/°C
IN+ pin input bias currentActive mode2020μA
IN-pin input bias current || VIN-pin input impedanceActive mode20 || 32020 || 320μA || kΩ
IN+ pin input leakage(5)Power-down mode0.1±0.50.1±0.5μA
IN-pin input leakage(5)Power-down mode0.1±0.50.1±0.5μA
DC ACCURACY
ADC basic resolution1212bits
Shunt voltage, 1 LSB step size1010μV
Bus voltage, 1 LSB step size44mV
Current measurement errorover Temperature±0.2%±0.5%±0.2%±0.3%(4)
TA=-25°C to 85°C±1%±0.5%(4)
Bus voltage measurement errorover Temperature±0.2%±0.5%±0.2%±0.5%
TA=-25°C to 85°C±1%±1%
Differential nonlinearity±0.1±0.1LSB
ADC TIMING
ADC conversion time12 bit532586532586μs
11 bit276304276304μs
10 bit148163148163μs
9 bit84938493μs
Minimum convert input low time44μs
SMBus
SMBus timeout(6)28352835ms
DIGITAL INPUTS (SDA as Input, SCL, A0, A1)
Input capacitance33pF
Leakage input current0 ≤ VIN ≤ VS0.110.11μA
VIH input logic level0.7 (VS)60.7 (VS)6V
VIL input logic level-0.30.3 (VS)-0.30.3 (VS)V

(1) BRNG is bit 13 of the Configuration register 00h in Figure 19.
(2) This parameter only expresses the full-scale range of the ADC scaling. In no event should more than 26 V be applied to this device. (3) Referred-to-input (RTI)
(4) Indicates improved specifications of the INA219B.
(5) Input leakage is positive (current flowing into the pin) for the conditions shown at the top of the table. Negative leakage currents can occur under different input conditions.
(6) SMBus timeout in the INA219 resets the interface any time SCL or SDA is low for over 28 ms.

Electrical Characteristics: (continued)

$\mathsf { A t } \mathsf { T } _ { \mathsf { A } } = 2 5 ^ { \circ } \mathsf { C }$ , V = 3.3 V, $\mathsf { V } _ { | \mathsf { N } + } = 1 2 \mathsf { V } ,$ $\mathsf { V } _ { \mathsf { S H U N T } } = ( \mathsf { V } _ { \mathsf { I N } + } - \mathsf { V } _ { \mathsf { I N } - } ) = 3 2$ mV, $\mathsf { P G A } = / 1$ , and $\mathsf { B R N G } ^ { ( 1 ) } = 1$ , unless otherwise noted.

PARAMETERTEST CONDITIONSINA219AINA219BUNIT
MINTYPMAXMINTYPMAX
Hysteresis500500mV
OPEN-DRAIN DIGITAL OUTPUTS (SDA)
Logic 0 output level $I_{\text{SINK}} = 3 \text{ mA}$ 0.150.40.150.4V
High-level output leakage current $V_{\text{OUT}} = V_{\text{S}}$ 0.110.11μA
POWER SUPPLY
Operating supply range35.535.5V
Quiescent current0.710.71mA
Quiescent current, power-down mode615615μA
Power-on reset threshold22V

7.6 Bus Timing Diagram Definitions(1)

FAST MODEHIGH-SPEED MODEUNIT
MINMAXMINMAX
$f_{(SCL)}$ SCL operating frequency0.0010.40.0012.56MHz
$t_{(BUF)}$ Bus free time between STOP and START condition1300160ns
$t_{(HDSTA)}$ Hold time after repeated START condition. After this period, the first clock is generated.600160ns
$t_{(SUSTA)}$ Repeated START condition setup time600160ns
$t_{(SUSTO)}$ STOP condition setup time600160ns
$t_{(HDDAT)}$ Data hold time0900090ns
$t_{(SUDAT)}$ Data setup time10010ns
$t_{(LOW)}$ SCL clock LOW period1300250ns
$t_{(HIGH)}$ SCL clock HIGH period60060ns
$t_{F}$ DAData fall time300150ns
$t_{F}CL$ Clock fall time30040ns
$t_{R}CL$ Clock rise time30040ns
$t_{R}CL$ Clock rise time for SCLK ≤ 100kHz1000ns

(1) Values based on a statistical analysis of a one-time sample of devices. Minimum and maximum values are not ensured and not production tested.


Figure 1. Bus Timing Diagram

7.7 Typical Characteristics

$\mathsf { A t } \mathsf { T } _ { \mathrm { A } } = 2 \mathsf { S ^ { o } C } , \mathsf { V } _ { \mathbb { S } } = 3 . 3 \vee , \mathsf { V } _ { \mathsf { I N } _ { \mathrm { + } } } = 1 2 \vee , \mathsf { V } _ { \mathsf { S H M N T } } = ( \mathsf { V } _ { \mathsf { I N } _ { \mathrm { + } } } - \mathsf { V } _ { \mathsf { I N } _ { \mathrm { - } } } ) = 3 2 \mathsf { m V } , \mathsf { P G A } = / 1$ , and $\mathsf { B R N G } = 1$ , unless otherwise noted.

Figure 2. Frequency Response

Figure 3. ADC Shunt Offset vs Temperature

Figure 4. ADC Shunt Gain Error vs Temperature

Figure 6. ADC Bus Gain Error vs Temperature

Figure 5. ADC Bus Voltage Offset vs Temperature

Figure 7. Integral Nonlinearity vs Input Voltage

Typical Characteristics (continued)

$\mathrm { a } _ { \mathsf { f } } \mathsf { T } _ { \mathsf { A } } = 2 5 ^ { \circ } \mathrm { C } , \mathsf { V } _ { \mathsf { S } } = 3 . 3 \vee , \mathsf { V } _ { \mathsf { I N } + } = 1 2 \vee , \mathsf { V } _ { \mathsf { S H U N T } } = ( \mathsf { V } _ { \mathsf { I N } + } - \mathsf { V } _ { \mathsf { I N } - } ) = 3 2$ mV, PGA = /1, and $\mathsf { B R N G } = 1$ , unless otherwise noted.

Figure 8. Input Currents With Large Differential Voltage $\mathsf { \Omega } ^ { \prime } ( \mathsf { V } _ { \mathsf { I N } + }$ at 12 V, Sweep Of $\mathsf { v } _ { \mathsf { I N } - } )$

Figure 9. Active $\mathsf { I } _ { \mathsf { Q } }$ vs Temperature

Figure 10. Shutdown $\mathsf { I } _ { \mathsf { Q } }$ vs Temperature
Figure 11. Active $\mathsf { I } _ { \mathsf { Q } }$ vs $\mathsf { I } ^ { 2 } \mathsf { C }$ Clock Frequency

Figure 12. Shutdown $\mathsf { I } _ { \mathsf { Q } }$ vs $\mathsf { I } ^ { 2 } \mathsf { C }$ Clock Frequency

8 Detailed Description

8.1 Overview

The INA219 is a digital current sense amplifier with an I2C- and SMBus-compatible interface. It provides digital current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems. Programmable registers allow flexible configuration for measurement resolution as well as continuous-versustriggered operation. Detailed register information appears at the end of this data sheet, beginning with Table 2. See the Functional Block Diagram section for a block diagram of the INA219 device.

8.2 Functional Block Diagram

8.3 Feature Description

8.3.1 Basic ADC Functions

The two analog inputs to the INA219, IN+ and IN–, connect to a shunt resistor in the bus of interest. The INA219 is typically powered by a separate supply from 3 to 5.5 V. The bus being sensed can vary from 0 to 26 V. There are no special considerations for power-supply sequencing (for example, a bus voltage can be present with the supply voltage off, and vice-versa). The INA219 senses the small drop across the shunt for shunt voltage, and senses the voltage with respect to ground from IN– for the bus voltage. Figure 13 shows this operation.

When the INA219 is in the normal operating mode (that is, MODE bits of the Configuration register are set to 111), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function (Configuration register, SADC bits). The device then converts the bus voltage up to the number set in the bus voltage averaging (Configuration register, BADC bits). The Mode control in the Configuration register also permits selecting modes to convert only voltage or current, either continuously or in response to an event (triggered).

All current and power calculations are performed in the background and do not contribute to conversion time; conversion times shown in the Electrical Characteristics: can be used to determine the actual conversion time.

Power-Down mode reduces the quiescent current and turns off current into the INA219 inputs, avoiding any supply drain. Full recovery from Power-Down requires 40 μs. ADC Off mode (set by the Configuration register, MODE bits) stops all conversions.

Writing any of the triggered convert modes into the Configuration register (even if the desired mode is already programmed into the register) triggers a single-shot conversion. Table 6 lists the triggered convert mode settings.

Feature Description (continued)


Figure 13. INA219 Configured for Shunt and Bus Voltage Measurement

Although the INA219 can be read at any time, and the data from the last conversion remain available, the conversion ready bit (Status register, CNVR bit) is provided to help coordinate one-shot or triggered conversions. The conversion ready bit is set after all conversions, averaging, and multiplication operations are complete.

The conversion ready bit clears under any of these conditions:

• Writing to the Configuration register, except when configuring the MODE bits for power down or ADC off (disable) modes

• Reading the Status register

• Triggering a single-shot conversion with the convert pin

8.3.1.1 Power Measurement

Current and bus voltage are converted at different points in time, depending on the resolution and averaging mode settings. For instance, when configured for 12-bit and 128 sample averaging, up to 68 ms in time between sampling these two values is possible. Again, these calculations are performed in the background and do not add to the overall conversion time.

8.3.1.2 PGA Function

If larger full-scale shunt voltages are desired, the INA219 provides a PGA function that increases the full-scale range up to 2, 4, or 8 times (320 mV). Additionally, the bus voltage measurement has two full-scale ranges: 16 or 32 V.

8.3.1.3 Compatibility With TI Hot Swap Controllers

The INA219 is designed for compatibility with hot swap controllers such the TI TPS2490. The TPS2490 uses a high-side shunt with a limit at 50 mV; the INA219 full-scale range of 40 mV enables the use of the same shunt for current sensing below this limit. When sensing is required at (or through) the 50-mV sense point of the TPS2490, the PGA of the INA219 can be set to /2 to provide an 80-mV full-scale range.

8.4 Device Functional Modes

8.4.1 Filtering and Input Considerations

Measuring current is often noisy, and such noise can be difficult to define. The INA219 offers several options for filtering by choosing resolution and averaging in the Configuration register. These filtering options can be set independently for either voltage or current measurement.

The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500-kHz (±30%) typical sampling rate. This architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling rate harmonics can cause problems. Because these signals are at 1 MHz and higher, they can be dealt with by incorporating filtering at the input of the INA219. The high frequency enables the use of low-value series resistors on the filter for negligible effects on measurement accuracy. In general, filtering the INA219 input is only necessary if there are transients at exact harmonics of the 500-kHz (±30%) sampling rate (>1 MHz). Filter using the lowest possible series resistance and ceramic capacitor. Recommended values are 0.1 to 1 μF. Figure 14 shows the INA219 with an additional filter added at the input.


Figure 14. INA219 With Input Filtering

Overload conditions are another consideration for the INA219 inputs. The INA219 inputs are specified to tolerate 26 V across the inputs. A large differential scenario might be a short to ground on the load side of the shunt. This type of event can result in full power-supply voltage across the shunt (as long the power supply or energy storage capacitors support it). It must be remembered that removing a short to ground can result in inductive kickbacks that could exceed the 26-V differential and common-mode rating of the INA219. Inductive kickback voltages are best dealt with by zener-type transient-absorbing devices combined with sufficient energy storage capacitance.

In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most likely cause of this event, particularly in applications with no large electrolytics present. This problem occurs because an excessive dV/dt can activate the ESD protection in the INA219 in systems where large currents are available. Testing has demonstrated that the addition of 10-Ω resistors in series with each input of the INA219 sufficiently protects the inputs against dV/dt failure up to the 26-V rating of the INA219. These resistors have no significant effect on accuracy.

8.5 Programming

An important aspect of the INA219 device is that it measure current or power if it is programmed based on the system. The device measures both the differential voltage applied between the IN+ and IN- input pins and the voltage at IN- pin. In order for the device to report both current and power values, the user must program the resolution of the Current Register (04h) and the value of the shunt resistor $( \mathsf { R } _ { \mathsf { S H U N T } } )$ present in the application to develop the differential voltage applied between the input pins. Both the Current_LSB and shunt resistor value are used in the calculation of the Calibration Register value that the device uses to calculate the corresponding current and power values based on the measured shunt and bus voltages.

After programming the Calibration Register, the Current Register (04h) and Power Register (03h) update accordingly based on the corresponding shunt voltage and bus voltage measurements. Until the Calibration Register is programmed, the Current Register (04h) and Power Register (03h) remain at zero.

8.5.1 Programming the Calibration Register

The Calibration Register is calculated based on Equation 1. This equation includes the term Current_LSB, which is the programmed value for the LSB for the Current Register (04h). The user uses this value to convert the value in the Current Register (04h) to the actual current in amperes. The highest resolution for the Current Register (04h) can be obtained by using the smallest allowable Current_LSB based on the maximum expected current as shown in Equation 2. While this value yields the highest resolution, it is common to select a value for the Current_LSB to the nearest round number above this value to simplify the conversion of the Current Register (04h) and Power Register (03h) to amperes and watts respectively. The $\mathsf { \bar { R } } _ { \mathsf { S H U N T } }$ term is the value of the external shunt used to develop the differential voltage across the input pins. The Power Register (03h) is internally set to be 20 times the programmed Current_LSB see Equation 3.

$$
\text { Cal } = \text { trunc } \left(\frac {0 . 0 4 0 9 6}{\text { Current_LSB } \times R _ {\text { SHUNT }}}\right)
$$

where

• 0.04096 is an internal fixed value used to ensure scaling is maintained properly

(1)

$$
\text { Current_LSB } = \frac {\text { Maximum Expected Current }}{2 ^ {1 5}}\tag{2}
$$

$$
\text { Power_LSB } = 2 0 \text { Current_LSB }\tag{3}
$$

Shunt voltage is calculated by multiplying the Shunt Voltage Register contents with the Shunt Voltage LSB of 10 $\mu \nu$

The Bus Voltage register bits are not right-aligned. In order to compute the value of the Bus Voltage, Bus Voltage Register contents must be shifted right by three bits. This shift puts the BD0 bit in the LSB position so that the contents can be multiplied by the Bus Voltage LSB of 4-mV to compute the bus voltage measured by the device.

After programming the Calibration Register, the value expected in the Current Register (04h) can be calculated by multiplying the Shunt Voltage register contents by the Calibration Register and then dividing by 4096 as shown in Equation 4. To obtain a value in amperes the Current register value is multiplied by the programmed Current_LSB.

$$
\text { Current Register } = \frac {\text { Shunt Voltage Register } \times \text { Calibration Register }}{4 0 9 6}\tag{4}
$$

The value expected in the Power register (03h) can be calculated by multiplying the Current register value by the Bus Voltage register value and then dividing by 5000 as shown in Equation 5. Power Register content is multiplied by Power LSB which is 20 times the Current_LSB for a power value in watts.

$$
\text { Power Register } = \frac {\text { Current Register } \times \text { Bus Voltage Register }}{5 0 0 0}\tag{5}
$$

Programming (continued)

8.5.2 Programming the Power Measurement Engine

8.5.2.1 Calibration Register and Scaling

The Calibration Register enables the user to scale the Current Register (04h) and Power Register (03h) to the most useful value for a given application. For example, set the Calibration Register such that the largest possible number is generated in the Current Register (04h) or Power Register (03h) at the expected full-scale point. This approach yields the highest resolution using the previously calculated minimum Current_LSB in the equation for the Calibration Register. The Calibration Register can also be selected to provide values in the Current Register (04h) and Power Register (03h) that either provide direct decimal equivalents of the values being measured, or yield a round LSB value for each corresponding register. After these choices have been made, the Calibration Register also offers possibilities for end user system-level calibration. After determining the exact current by using an external ammeter, the value of the Calibration Register can then be adjusted based on the measured current result of the INA219 to cancel the total system error as shown in Equation 6.

$$
\text { Corrected_Full_Scale_Cal } = \text { trunc } \left(\frac {\text { Cal } \times \text { MeasShuntCurrent }}{\text { INA219_Current }}\right)\tag{6}
$$

8.5.3 Simple Current Shunt Monitor Usage (No Programming Necessary)

The INA219 can be used without any programming if it is only necessary to read a shunt voltage drop and bus voltage with the default 12-bit resolution, 320-mV shunt full-scale range (PGA = /8), 32-V bus full-scale range, and continuous conversion of shunt and bus voltage.

Without programming, current is measured by reading the shunt voltage. The Current register and Power registe are only available if the Calibration register contains a programmed value.

8.5.4 Default Settings

The default power-up states of the registers are shown in the Register Details section of this data sheet. These registers are volatile, and if programmed to other than default values, must be re-programmed at every device power-up. Detailed information on programming the Calibration register specifically is given in the section, Programming the Calibration Register.

8.5.5 Bus Overview

The INA219 offers compatibility with both I2C and SMBus interfaces. The I2C and SMBus protocols are essentially compatible with one another.

The I2C interface is used throughout this data sheet as the primary example, with SMBus protocol specified only when a difference between the two systems is being addressed. Two bidirectional lines, SCL and SDA, connect the INA219 to the bus. Both SCL and SDA are open-drain connections.

The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates START and STOP conditions.

To address a specific device, the master initiates a START condition by pulling the data signal line (SDA) from a HIGH to a LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte on the rising edge of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA LOW.

Data transfer is then initiated and eight bits of data are sent, followed by an Acknowledge bit. During data transfer, SDA must remain stable while SCL is HIGH. Any change in SDA while SCL is HIGH is interpreted as a START or STOP condition.

Once all data have been transferred, the master generates a STOP condition, indicated by pulling SDA from LOW to HIGH while SCL is HIGH. The INA219 includes a 28-ms timeout on its interface to prevent locking up an SMBus.

Programming (continued)

8.5.5.1 Serial Bus Address

To communicate with the INA219, the master must first address slave devices through a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation.

The INA219 has two address pins, A0 and A1. Table 1 describes the pin logic levels for each of the 16 possible addresses. The state of pins A0 and A1 is sampled on every bus communication and should be set before any activity on the interface occurs. The address pins are read at the start of each communication event.

Table 1. INA219 Address Pins and Slave Addresses

A1A0SLAVE ADDRESS
GNDGND1000000
GND $V_{S+}$ 1000001
GNDSDA1000010
GNDSCL1000011
$V_{S+}$ GND1000100
$V_{S+}$ $V_{S+}$ 1000101
$V_{S+}$ SDA1000110
$V_{S+}$ SCL1000111
SDAGND1001000
SDA $V_{S+}$ 1001001
SDASDA1001010
SDASCL1001011
SCLGND1001100
SCL $V_{S+}$ 1001101
SCLSDA1001110
SCLSCL1001111

8.5.5.2 Serial Interface

The INA219 operates only as a slave device on the I2C bus and SMBus. Connections to the bus are made through the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The INA219 supports the transmission protocol for fast (1- to 400-kHz) and high-speed (1-kHz to 2.56-MHz) modes. All data bytes are transmitted most significant byte first.

8.5.6 Writing to and Reading from the INA219

Accessing a particular register on the INA219 is accomplished by writing the appropriate value to the register pointer. Refer to Table 2 for a complete list of registers and corresponding addresses. The value for the register pointer as shown in Figure 18 is the first byte transferred after the slave address byte with the R/W bit LOW. Every write operation to the INA219 requires a value for the register pointer.

Writing to a register begins with the first byte transmitted by the master. This byte is the slave address, with the R/W bit LOW. The INA219 then acknowledges receipt of a valid address. The next byte transmitted by the master is the address of the register to which data will be written. This register address value updates the register pointer to the desired register. The next two bytes are written to the register addressed by the register pointer. The INA219 acknowledges receipt of each data byte. The master may terminate data transfer by generating a START or STOP condition.

When reading from the INA219, the last value stored in the register pointer by a write operation determines which register is read during a read operation. To change the register pointer for a read operation, a new value must be written to the register pointer. This write is accomplished by issuing a slave address byte with the R/W bit LOW, followed by the register pointer byte. No additional data are required. The master then generates a START condition and sends the slave address byte with the R/W bit HIGH to initiate the read command. The next byte is transmitted by the slave and is the most significant byte of the register indicated by the register

www.ti.com

pointer. This byte is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master acknowledges receipt of the data byte. The master may terminate data transfer by generating a Not-Acknowledge after receiving any data byte, or generating a START or STOP condition. If repeated reads from the same register are desired, it is not necessary to continually send the register pointer bytes; the INA219 retains the register pointer value until it is changed by the next write operation.

Figure 15 and Figure 16 show write and read operation timing diagrams, respectively. Note that register bytes are sent most-significant byte first, followed by the least significant byte. Figure 17 shows the timing diagram for the SMBus Alert response operation. Figure 18 shows a typical register pointer configuration.


NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1.

Figure 15. Timing Diagram for Write Word Format

(3) ACK by Master can also be sent.

Figure 16. Timing Diagram for Read Word Format


NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1.

Figure 17. Timing Diagram for SMBus Alert

NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 and A1 pins. Refer to Table 1.
Figure 18. Typical Register Pointer Set

8.5.6.1 High-Speed I2C Mode

When the bus is idle, both the SDA and SCL lines are pulled high by the pull-up devices. The master generates a start condition followed by a valid serial byte containing high-speed (HS) master code 00001XXX. This transmission is made in fast (400 kbps) or standard (100 kbps) (F/S) mode at no more than 400 kbps. The INA219 does not acknowledge the HS master code, but does recognize it and switches its internal filters to support 2.56 Mbps operation.

The master then generates a repeated start condition (a repeated start condition has the same timing as the start condition). After this repeated start condition, the protocol is the same as F/S mode, except that transmission speeds up to 2.56 Mbps are allowed. Instead of using a stop condition, repeated start conditions should be used to secure the bus in HS-mode. A stop condition ends the HS-mode and switches all the internal filters of the INA219 to support the F/S mode. For bus timing, see Bus Timing Diagram Definitions(1) and Figure 1.

8.5.6.2 Power-Up Conditions

Power-up conditions apply to a software reset through the RST bit (bit 15) in the Configuration register, or the I2C bus General Call Reset.

(1) Values based on a statistical analysis of a one-time sample of devices. Minimum and maximum values are not ensured and not production tested.

8.6 Register Maps

8.6.1 Register Information

The INA219 uses a bank of registers for holding configuration settings, measurement results, maximum/minimum limits, and status information. Table 2 summarizes the INA219 registers; Functional Block Diagram shows registers.

Register contents are updated 4 μs after completion of the write command. Therefore, a 4-μs delay is required between completion of a write to a given register and a subsequent read of that register (without changing the pointer) when using SCL frequencies in excess of 1 MHz.

Table 2. Summary of Register Set

POINTER ADDRESSREGISTER NAMEFUNCTIONPOWER-ON RESETTYPE(1)
HEXBINARYHEX
00ConfigurationAll-register reset, settings for bus voltage range, PGA Gain, ADC resolution/averaging.00111001 10011111399FR/W
01Shunt voltageShunt voltage measurement data.Shunt voltage—R
02Bus voltageBus voltage measurement data.Bus voltage—R
03Power(2)Power measurement data.00000000 000000000000R
04Current(2)Contains the value of the current flowing through the shunt resistor.00000000 000000000000R
05CalibrationSets full-scale range and LSB of current and power measurements. Overall system calibration.00000000 000000000000R/W

8.6.2 Register Details

All INA219 16-bit registers are actually two 8-bit bytes through the I2C interface.

8.6.2.1 Configuration Register (address = 00h) [reset = 399Fh]

Figure 19. Configuration Register

1514131211109876543210
RST—BRNGPG1PG0BADC 4BADC 3BADC 2BADC 1SADC 4SADC 3SADC 2SADC 1MODE 3MODE 2MODE 1
R/W-0R/W-0R/W-1R/W-1R/W-1R/W-0R/W-0R/W-1R/W-1R/W-0R/W-0R/W-1R/W-1R/W-1R/W-1R/W-1

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 3. Bit Descriptions

RST: Reset Bit

Bit 15 Setting this bit to '1' generates a system reset that is the same as power-on reset. Resets all registers to default values; this bit self-clears.

BRNG: Bus Voltage Range

Bit 13 0 = 16V FSR 1 = 32V FSR (default value)

PG: PGA (Shunt Voltage Only)

Bits 11, 12 Sets PGA gain and range. Note that the PGA defaults to ÷8 (320mV range). Table 4 shows the gain and range for the various product gain settings.

Table 4. PG Bit Settings(1)

PG1PG0GAINRange
001±40 mV
01/2±80 mV
10/4±160 mV
11/8±320 mV

(1) Shaded values are default.

BADC: BADC Bus ADC Resolution/Averaging

Bits 7–10 These bits adjust the Bus ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Bus Voltage Register (02h).

SADC: SADC Shunt ADC Resolution/Averaging

Bits 3–6

These bits adjust the Shunt ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Shunt Voltage Register (01h).

BADC (Bus) and SADC (Shunt) ADC resolution/averaging and conversion time settings are shown in Table 5.

Table 5. ADC Settings(1)

ADC4ADC3ADC2ADC1Mode/SamplesConversion Time
0 $X^{(2)}$ 009 bit84 μs
0 $X^{(2)}$ 0110 bit148 μs
0 $X^{(2)}$ 1011 bit276 μs
0 $X^{(2)}$ 1112 bit532 μs
100012 bit532 μs
100121.06 ms
101042.13 ms
101184.26 ms
1100168.51 ms
11013217.02 ms
11106434.05 ms
111112868.10 ms

(1) Shaded values are default.

(2) X = Don't care

MODE: Operating Mode

Bits 0–2 Selects continuous, triggered, or power-down mode of operation. These bits default to continuous shunt and bus measurement mode. The mode settings are shown in Table 6

Table 6. Mode Settings(1)

MODE3MODE2MODE1MODE
000Power-down
001Shunt voltage, triggered
010Bus voltage, triggered
011Shunt and bus, triggered
100ADC off (disabled)
101Shunt voltage, continuous
110Bus voltage, continuous
111Shunt and bus, continuous

(1) Shaded values are default.

8.6.3 Data Output Registers

8.6.3.1 Shunt Voltage Register (address = 01h)

The Shunt Voltage register stores the current shunt voltage reading, $\mathsf { V } _ { \mathsf { S H U N T } }$ . Shunt Voltage register bits are shifted according to the PGA setting selected in the Configuration register (00h). When multiple sign bits are present, they will all be the same value. Negative numbers are represented in 2's complement format. Generate the 2's complement of a negative number by complementing the absolute value binary number and adding 1. Extend the sign, denoting a negative number by setting the MSB = 1. Extend the sign to any additional sign bits to form the 16-bit word.

Example: For a value of $\mathsf { V } _ { \mathsf { S H U N T } } = - 3 2 0 \mathsf { m V } \colon$

  1. Take the absolute value (include accuracy to 0.01 mV) → 320.00

  2. Translate this number to a whole decimal number → 32000

  3. Convert it to binary → 111 1101 0000 0000

www.ti.com

  1. Complement the binary result : 000 0010 1111 1111

  2. Add 1 to the Complement to create the Two’s Complement formatted result → 000 0011 0000 0000

  3. Extend the sign and create the 16-bit word: 1000 0011 0000 0000 = 8300h (Remember to extend the sign to all sign-bits, as necessary based on the PGA setting.)

At PGA = /8, full-scale range = ±320 mV (decimal = 32000). For $\mathsf { V } _ { \mathsf { S H U N T } } = + 3 2 0$ mV, Value = 7D00h; For VSHUNT = –320 mV, Value = 8300h; and LSB = 10µV.

Figure 20. Shunt Voltage Register at PGA = /8

1514131211109876543210
SIGNSD14_8SD13_8SD12_8SD11_8SD10_8SD9_8SD8_8SD7_8SD6_8SD5_8SD4_8SD3_8SD2_8SD1_8SD0_8

At PGA = /4, full-scale range = ±160 mV (decimal = 16000). For $\mathsf { V } _ { \mathsf { S H U N T } } = + 1 6 0 \mathrm { ~ m V } ,$ , Value = 3E80h; For VSHUNT = –160 mV, Value = C180h; and $\mathsf { L S B } = 1 0 \mu \ V .$

Figure 21. Shunt Voltage Register at PGA = /4

1514131211109876543210
SIGNSIGNSD13_4SD12_4SD11_4SD10_4SD9_4SD8_4SD7_4SD6_4SD5_4SD4_4SD3_4SD2_4SD1_4SD0_4

At PGA = /2, full-scale range = ±80 mV (decimal = 8000). For $\mathsf { V } _ { \mathsf { S H U N T } } = + 8 0$ mV, $\mathsf { V a l u e } = 1 \mathsf { F } 4 0 \mathsf { h } ;$ For $\mathsf { V } _ { \mathsf { S H U N T } } =$ –80 mV; Value = E0C0h; and LSB = 10µV.

Figure 22. Shunt Voltage Register at PGA = /2

1514131211109876543210
SIGNSIGNSIGNSD12_2SD11_2SD10_2SD9_2SD8_2SD7_2SD6_2SD5_2SD4_2SD3_2SD2_2SD1_2SD0_2

At PGA = /1, full-scale range = ±40 mV (decimal = 4000). For $\mathsf { V } _ { \mathsf { S H U N T } } = + 4 0$ mV, Value = 0FA0h; For $\mathsf { V } _ { \mathsf { S H U N T } } =$ –40 mV, Value = F060h; and LSB = 10µV.

Figure 23. Shunt Voltage Register at PGA = /1

1514131211109876543210
SIGNSIGNSIGNSIGNSD11_1SD10_1SD9_1SD8_1SD7_1SD6_1SD5_1SD4_1SD3_1SD2_1SD1_1SD0_1

Table 7. Shunt Voltage Register Format(1)

$V_{SHUNT}$ Reading (mV)Decimal ValuePGA = /8(D15:D0)PGA = /4(D15:D0)PGA = /2(D15:D0)PGA = /1(D15:D0)
320.02320020111 1101 0000 00000011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
320.01320010111 1101 0000 00000011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
320.00320000111 1101 0000 00000011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
319.99319990111 1100 1111 11110011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
319.98319980111 1100 1111 11100011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
⋮⋮⋮⋮⋮⋮
160.02160020011 1110 1000 00100011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
160.01160010011 1110 1000 00010011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
160.00160000011 1110 1000 00000011 1110 1000 00000001 1111 0100 00000000 1111 1010 0000
159.99159990011 1110 0111 11110011 1110 0111 11110001 1111 0100 00000000 1111 1010 0000
159.98159980011 1110 0111 11100011 1110 0111 11100001 1111 0100 00000000 1111 1010 0000
⋮⋮⋮⋮⋮⋮
80.0280020001 1111 0100 00100001 1111 0100 00100001 1111 0100 00000000 1111 1010 0000
80.0180010001 1111 0100 00010001 1111 0100 00010001 1111 0100 00000000 1111 1010 0000
80.0080000001 1111 0100 00000001 1111 0100 00000001 1111 0100 00000000 1111 1010 0000
79.9979990001 1111 0011 11110001 1111 0011 11110001 1111 0011 11110000 1111 1010 0000
79.9879980001 1111 0011 11100001 1111 0011 11100001 1111 0011 11100000 1111 1010 0000
⋮⋮⋮⋮⋮⋮
40.0240020000 1111 1010 00100000 1111 1010 00100000 1111 1010 00100000 1111 1010 0000
40.0140010000 1111 1010 00010000 1111 1010 00010000 1111 1010 00010000 1111 1010 0000
40.0040000000 1111 1010 00000000 1111 1010 00000000 1111 1010 00000000 1111 1010 0000
39.9939990000 1111 1001 11110000 1111 1001 11110000 1111 1001 11110000 1111 1001 1111
39.9839980000 1111 1001 11100000 1111 1001 11100000 1111 1001 11100000 1111 1001 1110
⋮⋮⋮⋮⋮⋮
0.0220000 0000 0000 00100000 0000 0000 00100000 0000 0000 00100000 0000 0000 0010
0.0110000 0000 0000 00010000 0000 0000 00010000 0000 0000 00010000 0000 0000 0001
000000 0000 0000 00000000 0000 0000 00000000 0000 0000 00000000 0000 0000 0000
-0.01-11111 1111 1111 11111111 1111 1111 11111111 1111 1111 11111111 1111 1111 1111
-0.02-21111 1111 1111 11101111 1111 1111 11101111 1111 1111 11101111 1111 1111 1110
⋮⋮⋮⋮⋮⋮
-39.98-39981111 0000 0110 00101111 0000 0110 00101111 0000 0110 00101111 0000 0110 0010
-39.99-39991111 0000 0110 00011111 0000 0110 00011111 0000 0110 00011111 0000 0110 0001
-40.00-40001111 0000 0110 00001111 0000 0110 00001111 0000 0110 00001111 0000 0110 0000
-40.01-40011111 0000 0101 11111111 0000 0101 11111111 0000 0101 11111111 0000 0110 0000
-40.02-40021111 0000 0101 11101111 0000 0101 11101111 0000 0101 11101111 0000 0110 0000
⋮⋮⋮⋮⋮⋮
-79.98-79981110 0000 1100 00101110 0000 1100 00101110 0000 1100 00101111 0000 0110 0000
-79.99-79991110 0000 1100 00011110 0000 1100 00011110 0000 1100 00011111 0000 0110 0000
-80.00-80001110 0000 1100 00001110 0000 1100 00001110 0000 1100 00001111 0000 0110 0000
-80.01-80011110 0000 1011 11111110 0000 1011 11111110 0000 1100 00001111 0000 0110 0000
-80.02-80021110 0000 1011 11101110 0000 1011 11101110 0000 1100 00001111 0000 0110 0000
⋮⋮⋮⋮⋮⋮
-159.98-159981100 0001 1000 00101100 0001 1000 00101110 0000 1100 00001111 0000 0110 0000
-159.99-159991100 0001 1000 00011100 0001 1000 00011110 0000 1100 00001111 0000 0110 0000
-160.00-160001100 0001 1000 00001100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
-160.01-160011100 0001 0111 11111100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
-160.02-160021100 0001 0111 11101100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
⋮⋮⋮⋮⋮⋮
-319.98-319981000 0011 0000 00101100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
-319.99-319991000 0011 0000 00011100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
-320.00-320001000 0011 0000 00001100 0001 1000 00001110 0000 1100 00001111 0000 0110 0000
-320.01-320011000 0011 0000 00001100 0001 1000 00001110 0000 1100 00001111 0000 0110 000

(1) Out-of-range values are shown in gray shading.

8.6.3.2 Bus Voltage Register (address = 02h)

The Bus Voltage register stores the most recent bus voltage reading, VBUS.

At full-scale range = 32 V (decimal = 8000, hex = 1F40), and LSB = 4 mV.

Figure 24. Bus Voltage Register

1514131211109876543210
BD12BD11BD10BD9BD8BD7BD6BD5BD4BD3BD2BD1BD0—CNVROVF

At full-scale range = 16 V (decimal = 4000, hex = 0FA0), and LSB = 4 mV.

CNVR: Conversion Ready

Bit 1 Although the data from the last conversion can be read at any time, the INA219 Conversion Ready bit (CNVR) indicates when data from a conversion is available in the data output registers. The CNVR bit is set after all conversions, averaging, and multiplications are complete. CNVR will clear under the following conditions:

1.) Writing a new mode into the Operating Mode bits in the Configuration Register (except for Power-Down or Disable)

2.) Reading the Power Register

OVF: Math Overflow Flag

Bit 0 The Math Overflow Flag (OVF) is set when the Power or Current calculations are out of range. It indicates that current and power data may be meaningless.

8.6.3.3 Power Register (address = 03h) [reset = 00h]

Full-scale range and LSB are set by the Calibration register. See the Programming the Calibration Register.

Figure 25. Power Register

1514131211109876543210
PD15PD14PD13PD12PD11PD10PD9PD8PD7PD6PD5PD4PD3PD2PD1PD0
R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

The Power register records power in watts by multiplying the values of the current with the value of the bus voltage according to the equation Equation 5:

8.6.3.4 Current Register (address = 04h) [reset = 00h]

Full-scale range and LSB depend on the value entered in the Calibration register. See Programming the Calibration Register for more information. Negative values are stored in 2's complement format.

Figure 26. Current Register

1514131211109876543210
CSIGNCD14CD13CD12CD11CD10CD9CD8CD7CD6CD5CD4CD3CD2CD1CD0
R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0R-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

The value of the Current register is calculated by multiplying the value in the Shunt Voltage register with the value in the Calibration register according to the Equation 4:

8.6.4 Calibration Register

8.6.4.1 Calibration Register (address = 05h) [reset = 00h]

Current and power calibration are set by bits FS15 to FS1 of the Calibration register. Note that bit FS0 is not used in the calculation. This register sets the current that corresponds to a full-scale drop across the shunt. Fullscale range and the LSB of the current and power measurement depend on the value entered in this register. See the Programming the Calibration Register. This register is suitable for use in overall system calibration. Note that the 0 POR values are all default.

www.ti.com

Figure 27. Calibration Register(1)

1514131211109876543210
FS15FS14FS13FS12FS11FS10FS9FS8FS7FS6FS5FS4FS3FS2FS1FS0
R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R/W-0R-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
(1) FS0 is a void bit and will always be 0. It is not possible to write a 1 to FS0. CALIBRATION is the value stored in FS15:FS1.

9 Application and Implementation

NOTE

Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality.

9.1 Application Information

The INA219 is a current shunt and power monitor with an $1 ^ { 2 } { \mathsf { C } } -$ and SMBus-compatible interface. The device monitors both a shunt voltage drop and bus supply voltage. Programmable calibration value, combined with an internal multiplier, enable readouts of current and power.

9.2 Typical Application

Figure 28 shows a typical application circuit for the INA219. Use a 0.1-μF ceramic capacitor for power-supply bypassing, placed as closely as possible to the supply and ground pins.

The input filter circuit consisting of $\mathsf { R } _ { \mathsf { F } 1 } , \mathsf { R } _ { \mathsf { F } 2 } ,$ and $C _ { \mathsf { F } }$ is not necessary in most applications. If the need for filtering is unknown, reserve board space for the components and install 0-Ω resistors for $\mathsf { R } _ { \mathsf { F } 1 }$ and $\mathsf { R } _ { \mathsf { F } 2 }$ and leave $C _ { \mathsf { F } }$ unpopulated, unless a filter is needed (see Filtering and Input Considerations).

The pull-up resistors shown on the SDA and SCL lines are not needed if there are pullup resistors on these same lines elsewhere in the system. Resistor values shown are typical: consult either the ${ \mathsf { I } } ^ { 2 } { \mathsf { C } }$ or SMBus specification to determine the acceptable minimum or maximum values and also refer to the Specifications for Output Current Limitations.


Figure 28. Typical Application Circuit

9.2.1 Design Requirements

The INA219 measures the voltage across a current-sensing resistor $( \mathsf { R } _ { \mathsf { S H U N T } } )$ when current passes through the resistor. The device also measures the bus supply voltage, and calculates power when calibrated. This section goes through the steps to program the device for power measurements, and shows the register results Table 8.

The Conditions for the example circuit is: Maximum expected load current = 15 A, Nominal load current = 10 A, $\mathsf { V } _ { \mathsf { C M } } = 1 2 \mathsf { V } , \mathsf { R } _ { \mathsf { S H M N T } } = 2 \mathsf { m } \Omega , \dot { \mathsf { V } } _ { \mathsf { S H M N T } } \mathsf { F S R } = 4 0 \mathsf { m V } ( \mathsf { P G } \dot { \mathsf { A } } = / 1 )$ , and BRNG = 0 (VBUS range = 16 V).

9.2.2 Detailed Design Procedure

Figure 29 shows a nominal 10-A load that creates a differential voltage of 20 mV across a 2-mΩ shunt resistor. The common mode is at 12 volts and the voltage present at the IN– pin is equal to the common-mode voltage minus the differential drop across the resistor.

Typical Application (continued)

For this example, the minimum-current LSB is calculated to be 457.78 µA/bit, assuming a maximum expected current of 15 A using Equation 2. This value is rounded up to 1 mA/bit and is chosen for the current LSB. Setting the current LSB to this value allows for sufficient precision while serving to simplify the math as well. Using Equation 1 results in a calibration value of 20480 (5000h). This value is then programmed into the Calibration register.


Figure 29. Example Circuit Configuration

The bus voltage is internally measured at the IN– pin to calculate the voltage level delivered to the load. The Bus Voltage register bits are not right-aligned; therefore, they must be shifted right by three bits. Multiply the shifted contents by the 4-mV LSB to compute the bus voltage measured by the device in volts. The shifted value of the Bus Voltage register contents is equal to BB3h, the decimal equivalent of 2995. This value of 2995 is multiplied by the 4-mV LSB, and results in a value of 11.98 V. As shown, the voltage at the IN– pin is 11.98 V. For a 40- mV, full-scale range, this small difference is not a significant deviation from the 12-V common-mode voltage. However, at larger full-scale ranges, this deviation can be much larger.

The Current register content is internally calculated using Equation 4, and the result of 10000 (2710h) is automatically loaded into the register. Current in amperes is equal to 1 mA/bit times 10000, and results in a 10-A load current.

The Power register content is internally calculated using Equation 5 and the result of 5990 (1766h) is automatically loaded into the register. Multiplying this result by the Power register LSB 20 × 10–3(20 times 1 × 10–3 current LSB using Equation 3), results in a power calculation of 5990 × 20 mW/bit, and equals 119.8 W. This result matches what is expected for this register. A calculation for the power delivered to the load uses 11.98 V (12 VCM – 20-mV shunt drop) multiplied by the load current of 10 A to give a 119.8-W result.

9.2.2.1 Register Results for the Example Circuit

Table 8 shows the register readings for the Calibration example.

Table 8. Register Results(1)

REGISTER NAMEADDRESSCONTENTSADJDECLSBVALUE
Configuration00h019Fh
Shunt01h07D0h200010 μV20 mV
Bus02h5D98h0BB329954 mV11.98 V
Calibration05h5000h20480
Current04h2710h100001 mA10.0 A
Power03h1766h599020 mW119.8 W

(1) Conditions: load = 10 A, $\mathsf { V } _ { \mathsf { C M } } = 1 2 \mathsf { V } ,$ RSHUNT = 2 mΩ, VSHUNT FSR = 40 mV, and $\mathsf { V } _ { \mathsf { B U S } } = \mathsf { V } _ { \mathsf { I N } } .$ , BRNG = 0 (VBUS range = 16 V).

10 Power Supply Recommendations

The input circuitry of the device can accurately measure signals on common-mode voltages beyond its power supply voltage, ${ \mathsf { V } } _ { \mathsf { S } } .$ . For example, the voltage applied to the ${ \sf V } _ { \sf S }$ power supply terminal can be 5 V, whereas the load power-supply voltage being monitored (the common-mode voltage) can be as high as 26 V. Note also that the device can withstand the full 0-V to 26-V range at the input terminals, regardless of whether the device has power applied or not.

Place the required power-supply bypass capacitors as close as possible to the supply and ground terminals of the device to ensure stability. A typical value for this supply bypass capacitor is 0.1 μF. Applications with noisy or high-impedance power supplies may require additional decoupling capacitors to reject power-supply noise.

11 Layout

11.1 Layout Guidelines

Connect the input pins (IN+ and IN–) to the sensing resistor using a Kelvin connection or a 4-wire connection. These connection techniques ensure that only the current-sensing resistor impedance is detected between the input pins. Poor routing of the current-sensing resistor commonly results in additional resistance present between the input pins. Given the very low ohmic value of the current-sensing resistor, any additional high-current carrying impedance causes significant measurement errors. Place the power-supply bypass capacitor as close as possible to the supply and ground pins.

11.2 Layout Example


Figure 30. Recommended Layout

12 Device and Documentation Support

12.1 Community Resources

The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use.

TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers.

Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support.

12.2 Trademarks

E2E is a trademark of Texas Instruments.

All other trademarks are the property of their respective owners.

12.3 Electrostatic Discharge Caution

These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.

12.4 Glossary

SLYZ022 — TI Glossary.

This glossary lists and explains terms, acronyms, and definitions.

13 Mechanical, Packaging, and Orderable Information

The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation.

PACKAGING INFORMATION

Orderable part numberStatus(1)Material type(2)Package | PinsPackage qty | CarrierRoHS(3)Lead finish/ Ball material(4)MSL rating/ Peak reflow(5)Op temp (°C)Part marking(6)
INA219AIDObsoleteProductionSOIC (D) | 8--Call TICall TI-40 to 125I219A
INA219AIDCNRActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNR.AActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNR.BActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNR1G4ActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNR1G4.AActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNR1G4.BActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNTActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNT.AActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDCNT.BActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125A219
INA219AIDRActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219AIDR.AActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219AIDR.BActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219AIDRG4ActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219AIDRG4.AActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219AIDRG4.BActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219A
INA219BIDObsoleteProductionSOIC (D) | 8--Call TICall TI-40 to 125I219B
INA219BIDCNRActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNR.AActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNR.BActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNRG4ActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNRG4.AActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNRG4.BActiveProductionSOT-23 (DCN) | 83000 | LARGE T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNTActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNT.AActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDCNT.BActiveProductionSOT-23 (DCN) | 8250 | SMALL T&RYesNIPDAULevel-2-260C-1 YEAR-40 to 125B219
INA219BIDRActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219B
INA219BIDR.AActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219B
INA219BIDR.BActiveProductionSOIC (D) | 82500 | LARGE T&RYesNIPDAULevel-1-260C-UNLIM-40 to 125I219B

(1) Status: For more details on status, see our product life cycle.

(2) Material type: When designated, preproduction parts are prototypes/experimental devices, and are not yet approved or released for full production. Testing and final process, including without limitation quality assurance, reliability performance testing, and/or process qualification, may not yet be complete, and this item is subject to further changes or possible discontinuation. If available for ordering, purchases will be subject to an additional waiver at checkout, and are intended for early internal evaluation purposes only. These items are sold without warranties of any kind.

(3) RoHS values: Yes, No, RoHS Exempt. See the TI RoHS Statement for additional information and value definition.

(4) Lead finish/Ball material: Parts may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead finish/Ball material values may wrap to two lines if the finish value exceeds the maximum column width.

(5) MSL rating/Peak reflow: The moisture sensitivity level ratings and peak solder (reflow) temperatures. In the event that a part has multiple moisture sensitivity ratings, only the lowest level per JEDEC standards is shown. Refer to the shipping label for the actual reflow temperature that will be used to mount the part to the printed circuit board.

(6) Part marking: There may be an additional marking, which relates to the logo, the lot trace code information, or the environmental category of the part.

Multiple part markings will be inside parentheses. Only one part marking contained in parentheses and separated by a "~" will appear on a part. If a line is indented then it is a continuation of the previous line and the two combined represent the entire part marking for that device

Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, an makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representativ and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS number

In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.

TAPE AND REEL INFORMATION

A0Dimension designed to accommodate the component width
B0Dimension designed to accommodate the component length
K0Dimension designed to accommodate the component thickness
WOverall width of the carrier tape
P1Pitch between successive cavity centers

Reel Width (W1)
QUADRANT ASSIGNMENTS FOR PIN 1 ORIENTATION IN TAPE

*All dimensions are nomina

DevicePackage TypePackage DrawingPinsSPQReel Diameter (mm)Reel Width W1 (mm)A0 (mm)B0 (mm)K0 (mm)P1 (mm)W (mm)Pin1 Quadrant
INA219AIDCNRSOT-23DCN83000180.08.43.23.21.44.08.0Q3
INA219AIDCNRSOT-23DCN83000179.08.43.23.21.44.08.0Q3
INA219AIDCNR1G4SOT-23DCN83000180.08.43.23.21.44.08.0Q3
INA219AIDCNTSOT-23DCN8250180.08.43.23.21.44.08.0Q3
INA219AIDCNTSOT-23DCN8250179.08.43.23.21.44.08.0Q3
INA219AIDRSOICD82500330.012.56.45.22.18.012.0Q1
INA219AIDRG4SOICD82500330.012.56.45.22.18.012.0Q1
INA219BIDCNRSOT-23DCN83000179.08.43.23.21.44.08.0Q3
INA219BIDCNRSOT-23DCN83000180.08.43.23.21.44.08.0Q3
INA219BIDCNRG4SOT-23DCN83000180.08.43.23.21.44.08.0Q3
INA219BIDCNTSOT-23DCN8250180.08.43.23.21.44.08.0Q3
INA219BIDRSOICD82500330.012.56.45.22.18.012.0Q1

*All dimensions are nominal

DevicePackage TypePackage DrawingPinsSPQLength (mm)Width (mm)Height (mm)
INA219AIDCNRSOT-23DCN83000210.0185.035.0
INA219AIDCNRSOT-23DCN83000213.0191.035.0
INA219AIDCNR1G4SOT-23DCN83000210.0185.035.0
INA219AIDCNTSOT-23DCN8250210.0185.035.0
INA219AIDCNTSOT-23DCN8250213.0191.035.0
INA219AIDRSOICD82500353.0353.032.0
INA219AIDRG4SOICD82500353.0353.032.0
INA219BIDCNRSOT-23DCN83000213.0191.035.0
INA219BIDCNRSOT-23DCN83000210.0185.035.0
INA219BIDCNRG4SOT-23DCN83000210.0185.035.0
INA219BIDCNTSOT-23DCN8250210.0185.035.0
INA219BIDRSOICD82500353.0353.032.0

SMALL OUTLINE INTEGRATED CIRCUIT

NOTES:

SMALL OUTLINE INTEGRATED CIRCUIT

NOTES: (continued)

  1. Publication IPC-7351 may have alternate designs.

  2. Solder mask tolerances between and around signal pads can vary based on board fabrication site.

SMALL OUTLINE INTEGRATED CIRCUIT


SOLDER PASTE EXAMPLE BASED ON .005 INCH [0.125 MM] THICK STENCIL SCALE:8X

4214825/C 02/2019

NOTES: (continued)

  1. Laser cutting apertures with trapezoidal walls and rounded corners may offer better paste release. IPC-7525 may have alternate design recommendations.

  2. Board assembly site may have different recommendations for stencil design.

DCN (R-PDSO-G8)

PLASTIC SMALL-OUTLINE PACKAGE (DIE DOWN)

G. Body dimensions do not include flash or protrusion. Mold flash and protrusion shall not exceed 0.25 per side.

DCN (R-PDSO-G8)

PLASTIC SMALL-OUTLINE PACKAGE (DIE DOWN)


NOTES: A. All linear dimensions are in millimeters.
B. This drawing is subject to change without notice.

C. Publication IPC-7351 is recommended for alternate designs.

D. Laser cutting apertures with trapezoidal walls and also rounding corners will offer better paste release. Customers should contact their board assembly site for stencil design recommendations. Refer to IPC-7525.

E. Customers should contact their board fabrication site for solder mask tolerances between and around signal pads.

Extracted Images

Figures and diagrams from the PDF

Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.

d89e5bace4558f4dc3148175f175f46315ef12c479f817532b63c533e200b388.jpg

d89e5bace4558f4dc3148175f175f46315ef12c479f817532b63c533e200b388.jpg

73c02158256656958389e6dac59eeb92adb6155dfcbe5aecd5d4b6e5ea4bc86d.jpg

73c02158256656958389e6dac59eeb92adb6155dfcbe5aecd5d4b6e5ea4bc86d.jpg

9083fb31dd0c81e8a20a1712b3be1947e712b147b042983f1d2189f9af98b976.jpg

9083fb31dd0c81e8a20a1712b3be1947e712b147b042983f1d2189f9af98b976.jpg

80bf8d6da7572c90f68fa2abe9a98e818bb5fca50d0fdda5ab841b66ebd0bb6a.jpg

80bf8d6da7572c90f68fa2abe9a98e818bb5fca50d0fdda5ab841b66ebd0bb6a.jpg

faab644a5de4586a900228093cdf22637a3d6326a3c7e1aff03ce2fdd6a7ff1d.jpg

faab644a5de4586a900228093cdf22637a3d6326a3c7e1aff03ce2fdd6a7ff1d.jpg

b644ab16305922819d66a3eff920ad11117a28070569c86dcb4015dc622aebe4.jpg

b644ab16305922819d66a3eff920ad11117a28070569c86dcb4015dc622aebe4.jpg

2dad4920aceb761efbd425439c3f92f2fc718a2b72a7e7f2fa8bd01c89bbf806.jpg

2dad4920aceb761efbd425439c3f92f2fc718a2b72a7e7f2fa8bd01c89bbf806.jpg

54654f430b285f01d6b7ff480c43a6325f25478390e92e1e49fd4ff564fbacfa.jpg

54654f430b285f01d6b7ff480c43a6325f25478390e92e1e49fd4ff564fbacfa.jpg

6ca1943863ca1407fbf72c459a990e9f470c7bfe2e2bdcff9874d5660873c7b7.jpg

6ca1943863ca1407fbf72c459a990e9f470c7bfe2e2bdcff9874d5660873c7b7.jpg

6df0685e546e756d8020117113f6cb3b76c6723ce74e24514ed997b2dabadef5.jpg

6df0685e546e756d8020117113f6cb3b76c6723ce74e24514ed997b2dabadef5.jpg

32cdaae76038a7d479521d3aef3019c77419f721ba34170a9d9fabc3404cc76c.jpg

32cdaae76038a7d479521d3aef3019c77419f721ba34170a9d9fabc3404cc76c.jpg

1b2501d2d5d91399fcbed2eb114d4b8128358acc5ce9c8863dcd344546504c6f.jpg

1b2501d2d5d91399fcbed2eb114d4b8128358acc5ce9c8863dcd344546504c6f.jpg

7475677e863950f45680ebc571191631af0f67be01bff5b8af782068aaca698a.jpg

7475677e863950f45680ebc571191631af0f67be01bff5b8af782068aaca698a.jpg

242b04a29ae83e204557e03c9053053dcee078865579dd0ee6873ce9e2ed1e94.jpg

242b04a29ae83e204557e03c9053053dcee078865579dd0ee6873ce9e2ed1e94.jpg

0af743c9e80becb29d35522ac18b9be1100e9b1d31ea15750e31f3f3c1623c9c.jpg

0af743c9e80becb29d35522ac18b9be1100e9b1d31ea15750e31f3f3c1623c9c.jpg

18be7e134b699663dbd68e260091cc9b727ea73f28d387dc87251fd27540ce68.jpg

18be7e134b699663dbd68e260091cc9b727ea73f28d387dc87251fd27540ce68.jpg

bd330b1b1aeed4f9e0a7b462a1736ef2eb1ba650f647aa2fb8b5c541745e19cf.jpg

bd330b1b1aeed4f9e0a7b462a1736ef2eb1ba650f647aa2fb8b5c541745e19cf.jpg

008cd8fe28fa4ef1617caeb178bd5a98b50421684ec0c75506e627443955ecf9.jpg

008cd8fe28fa4ef1617caeb178bd5a98b50421684ec0c75506e627443955ecf9.jpg

ab134af48ed62233bb0a9b7d81af4273e57c053f523b360f57f5b0ccd6c477e3.jpg

ab134af48ed62233bb0a9b7d81af4273e57c053f523b360f57f5b0ccd6c477e3.jpg

a78a6fa9955d38b509f779b975ca19ef21a7a2422bf3a9511c88e3c99d785865.jpg

a78a6fa9955d38b509f779b975ca19ef21a7a2422bf3a9511c88e3c99d785865.jpg

4d5019e63b68c49f153a3a1f56526091b37150cc14edac4bfb0b0f0279f98c72.jpg

4d5019e63b68c49f153a3a1f56526091b37150cc14edac4bfb0b0f0279f98c72.jpg

14ccd984a6c6db51dec40b07b4498e7e9f662267c0afcaac73c1323f678eebf3.jpg

14ccd984a6c6db51dec40b07b4498e7e9f662267c0afcaac73c1323f678eebf3.jpg

018c6bb411cc5ec00093fa37665b3ceb18e6ef6e199d13d79ee2481a92a6674f.jpg

018c6bb411cc5ec00093fa37665b3ceb18e6ef6e199d13d79ee2481a92a6674f.jpg

3f59054f13b734009cf021ff0ac57acc1cc42e066438ce2ddba88c9004ca07bd.jpg

3f59054f13b734009cf021ff0ac57acc1cc42e066438ce2ddba88c9004ca07bd.jpg

33e3dc45f2da5606f060fd6f8fc553d67eb49a300eb66b94c1c8fa75020ead4c.jpg

33e3dc45f2da5606f060fd6f8fc553d67eb49a300eb66b94c1c8fa75020ead4c.jpg

964a110669698b5fcb7a14e92c6f2906f2ea959ac90895fe0cb9974699b0e5cf.jpg

964a110669698b5fcb7a14e92c6f2906f2ea959ac90895fe0cb9974699b0e5cf.jpg

a8a4d559f171144a95be4ec89ef8ed1643da55f6e976a1d1a04b5810e4080682.jpg

a8a4d559f171144a95be4ec89ef8ed1643da55f6e976a1d1a04b5810e4080682.jpg

857d8a963658f78c8e2972cf42e82dcf2b5a7ba039c65b5fd10208c6b4572fa1.jpg

857d8a963658f78c8e2972cf42e82dcf2b5a7ba039c65b5fd10208c6b4572fa1.jpg

00859b0a3af0a26c93dce173d381ad06d1effd77e64531644c217f1c2790b97f.jpg

00859b0a3af0a26c93dce173d381ad06d1effd77e64531644c217f1c2790b97f.jpg

dd5df4a16b53fae7d3f759a727527e8318d7623e287036438950ce06a0bf79df.jpg

dd5df4a16b53fae7d3f759a727527e8318d7623e287036438950ce06a0bf79df.jpg

cf8ce7cca05dc8641eb2df1c703184ce76ba59cf605b4a8ca583b252900d8f33.jpg

cf8ce7cca05dc8641eb2df1c703184ce76ba59cf605b4a8ca583b252900d8f33.jpg

5bc78b95b649acae57cd952280586afd1b878ad8dbf58410b9869ff1088f19f0.jpg

5bc78b95b649acae57cd952280586afd1b878ad8dbf58410b9869ff1088f19f0.jpg

12622fdb042b693c35c40ccdd0c610034c759db34c34518a22cd9765aa3c8ccd.jpg

12622fdb042b693c35c40ccdd0c610034c759db34c34518a22cd9765aa3c8ccd.jpg

8d078d1bdc10bbc51cf408b33e399671f2434028df0a465739a7a9d0649410b5.jpg

8d078d1bdc10bbc51cf408b33e399671f2434028df0a465739a7a9d0649410b5.jpg

89b656de7280bbb29178a80232237e2dc05c8d1df6a07a77bbcbf6804b206bbf.jpg

89b656de7280bbb29178a80232237e2dc05c8d1df6a07a77bbcbf6804b206bbf.jpg

e496c7cb8c198800bdd638899483244dc100a9b088df69caea32a288f688ccfc.jpg

e496c7cb8c198800bdd638899483244dc100a9b088df69caea32a288f688ccfc.jpg

8dcb60bfe689f2349dc53a8276ac04ffbaadbc5af0224663eecab07c3dd38157.jpg

8dcb60bfe689f2349dc53a8276ac04ffbaadbc5af0224663eecab07c3dd38157.jpg

4505be38d41fc979098c1ed821b87b1a3e1a656cf5ccee398032db68f32079e6.jpg

4505be38d41fc979098c1ed821b87b1a3e1a656cf5ccee398032db68f32079e6.jpg

aee26a40aeaeac8032adddcaaa6107b9e429cdcd58fd576aad03c16058ae9222.jpg

aee26a40aeaeac8032adddcaaa6107b9e429cdcd58fd576aad03c16058ae9222.jpg

e9bac39d567968ca55068f93c7a41cd9083111007fae7388a236edfb2135c707.jpg

e9bac39d567968ca55068f93c7a41cd9083111007fae7388a236edfb2135c707.jpg

fee8142d14c9016ed4ceb669677717e2dd0260a03b2ccf0949042c257931273e.jpg

fee8142d14c9016ed4ceb669677717e2dd0260a03b2ccf0949042c257931273e.jpg

b8c87b1b24830ddb3fe0f667ac3918766bd6e5f108b6c09ff9f7659ed2a108f4.jpg

b8c87b1b24830ddb3fe0f667ac3918766bd6e5f108b6c09ff9f7659ed2a108f4.jpg

bbff5e0bddd581472d9d31dee0458abafb76a93fa149e6384e85744dd3cda786.jpg

bbff5e0bddd581472d9d31dee0458abafb76a93fa149e6384e85744dd3cda786.jpg

02bbea644bc9f6fe7ad3f8fdda1531dfc60aba286f01e095d8c1ae2730191afb.jpg

02bbea644bc9f6fe7ad3f8fdda1531dfc60aba286f01e095d8c1ae2730191afb.jpg

b4c124cc59749d938023b11476675428ce491e853e2c09a1e9167581551cba0c.jpg

b4c124cc59749d938023b11476675428ce491e853e2c09a1e9167581551cba0c.jpg

6f7c890b44efbe9f3f78925040616c4e2fbce5146be402d50014b4914c902902.jpg

6f7c890b44efbe9f3f78925040616c4e2fbce5146be402d50014b4914c902902.jpg

69f6d663cb4288a5afc28b6e691e621639cf9507f45a5624bd0f1d2b477b07bc.jpg

69f6d663cb4288a5afc28b6e691e621639cf9507f45a5624bd0f1d2b477b07bc.jpg

56c1bb8ffc10d322e5bdbd0348ebe5afe275915ce11ecaec8944e62644b0fa14.jpg

56c1bb8ffc10d322e5bdbd0348ebe5afe275915ce11ecaec8944e62644b0fa14.jpg

ca985b8dedbeae0188c388c659a25e8a0567cc479af0fbe6c0aede10ebaa90de.jpg

ca985b8dedbeae0188c388c659a25e8a0567cc479af0fbe6c0aede10ebaa90de.jpg

808a74e91f05a4e3f0ae66540cd0e96d482f316d2affca58192dab159d970dbe.jpg

808a74e91f05a4e3f0ae66540cd0e96d482f316d2affca58192dab159d970dbe.jpg

8edd91d15c4939a58b8daa3ef437c84160192c12bfd2a6c011785ea1fc227643.jpg

8edd91d15c4939a58b8daa3ef437c84160192c12bfd2a6c011785ea1fc227643.jpg

12f7beaaf372c8fe605d1d84f623134b4229504b2a060498c60ac00551b16900.jpg

12f7beaaf372c8fe605d1d84f623134b4229504b2a060498c60ac00551b16900.jpg

05d5e1976133dfcd25f675a3f8d38fd4f757e83076f6a4bcb06e3962d1f4ae78.jpg

05d5e1976133dfcd25f675a3f8d38fd4f757e83076f6a4bcb06e3962d1f4ae78.jpg

f5397bbd0332ecf9ef2978d442489d75353fc3f091fbfb6bb274e23b48f6ec1f.jpg

f5397bbd0332ecf9ef2978d442489d75353fc3f091fbfb6bb274e23b48f6ec1f.jpg

e8fe37f266ad1b2e1994f662cb28a913c0b05ec4505f697a8b9438531a53298e.jpg

e8fe37f266ad1b2e1994f662cb28a913c0b05ec4505f697a8b9438531a53298e.jpg

5c3cb55f67adc83654e6810c91f6dbe0fd9cb40f6310e7292b92ebdacb641bc5.jpg

5c3cb55f67adc83654e6810c91f6dbe0fd9cb40f6310e7292b92ebdacb641bc5.jpg

319b9506bea78ea2d9d6f8421d0279d79b54fc0b7f98d5ad4d6d548cec6fca00.jpg

319b9506bea78ea2d9d6f8421d0279d79b54fc0b7f98d5ad4d6d548cec6fca00.jpg

324b6253657f2ea37f8832ac3851913b70d94647808677821eeaedaf3240865d.jpg

324b6253657f2ea37f8832ac3851913b70d94647808677821eeaedaf3240865d.jpg

34b21509e7a0a9a9521486158f8db22e4203011a3de340996723b4855e4498a8.jpg

34b21509e7a0a9a9521486158f8db22e4203011a3de340996723b4855e4498a8.jpg

3f75705e265fd2cbbcc92c6d98f9cf9f4633c072a126a257489e8cc7396a8dff.jpg

3f75705e265fd2cbbcc92c6d98f9cf9f4633c072a126a257489e8cc7396a8dff.jpg

Agent APIs

Use this datasheet from any agent

Send the page, markdown, chunks, or search endpoint to ChatGPT, Claude, embedr-app, or your own tooling.