Datasheet docs

Panasonic Corporation

Panasonic LD-P relay

Slim sealed 1 Form A power relay with a 12 V DC coil and 5 A switching capacity.

Electromechanical power relayALDP112LD-PThrough-hole PCB relay

LD-P RELAYS

Slim (7.2 mm), 1 Form A 5 A, Power relay

Protective construction:Sealed

FEATURES

Rated switching capacity: 5 A 277 V AC

Ambient temperature: -40 to +85°C

Excellent heat resistance and tracking performance EN60695 (GWT2-11, GWFI2-12, GWIT2-13) data available (for VDE) (Please consult us for details.)

Compact size: 7.2 mm(W) X 20.5 mm(L) X 15.3 mm(H)

TYPICAL APPLICATIONS

Boilers, Hot water units

Air conditioner, Fan heaters

Refrigerator

Microwave ovens

(Unit:mm)

ORDERING INFORMATION (PART NO.)

Note) The "W" at the end of the part number only appears on the inner and outer packing. It does not appear on the relay itself.

TYPES

Contact arrangementRated coil voltagePart No. *Standard packing
Class E insulationClass F insulationInner cartonOuter carton
1 Form A5 V DCALDP105WALDP1F05WCarton: 100 pcsTube: 50 pcsCarton: 500 pcsTube: 1,000 pcs
6 V DCALDP106WALDP1F06W
9 V DCALDP109WALDP1F09W
12 V DCALDP112WALDP1F12W
18 V DCALDP118WALDP1F18W
24 V DCALDP124WALDP1F24W

* Tube packing types available. When ordering, please remove sufix “W”.

RATING

Coil data

• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.

Therefore, please use the relay within ±5% of rated coil voltage.

• ‘Initial’ means the condition of products at the time of delivery.

Rated coil voltageOperate $voltage^{*1}$ (at 20°C)Release $voltage^{*1}$ (at 20°C)Rated operating current(±10%, at 20°C)Coil resistance(±10%, at 20°C)Rated operating powerMax. allowable $voltage^{*2}$ (at 20°C)
5 V DCMax. 75% V of rated coil voltage (Initial)Min. 5% V of rated coil voltage (Initial)40 mA125 Ω200 mW180% V of rated coil voltage
6 V DC33.3 mA180 Ω
9 V DC22.2 mA405 Ω
12 V DC16.7 mA720 Ω
18 V DC11.1 mA1,620 Ω
24 V DC8.3 mA2,880 Ω

*1. square, pulse drive
*2. Maximum allowable voltage is the maximum voltage which can satisfy the coil temperature rise value. Please refer to “Max. applied voltage and temperature rise” in GUIDELINES FOR USAGE.

Specifications

ItemSpecifications
Contact dataContact arrangement1 Form A
Contact resistance (initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact materialAgNi type
Contact rating (resistive)5 A 277 V AC, 3 A 30 V DC
Max. switching power (resistive)1,385 VA, 90 W
Max. switching voltage277 V AC, 30 V DC
Max. switching current5 A (AC), 3 A (DC)
Min. switching load (reference value)*1100 mA 5 V DC
Insulation resistance (initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric strength (initial)Between open contacts750 Vrms for 1 min. (detection current: 10 mA)
Between contact and coil4,000 Vrms for 1 min. (detection current: 10 mA)
Surge withstand voltage (initial)*2Between contact and coil10,000 V
Time characteristics (initial)Operate timeMax.10 ms at rated coil voltage (at 20°C, without bounce)
Release timeMax.10 ms at rated coil voltage (at 20°C, without bounce, with diode)
Shock resistanceFunctional300 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Destructive1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration resistanceFunctional10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Destructive10 to 55 Hz (at double amplitude of: 1.5 mm)
Expected lifeMechanical lifeMin. 5×106 (at 180 times/min.)
ConditionsConditions for usage, transport and storage*3Ambient temperature: -40 to +85°C, Humidity: 5 to 85% RH (Avoid icing and condensation)
Unit weightApprox. 4 g

*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load
*2. Wave is standard shock voltage of ±1.2×50 μs according to JEC-212-1981
*3. For ambient temperature, please read “GUIDELINES FOR RELAY USAGE”

Expected electrical life

Conditions: Resistive load, at 20°C, switching frequency 20 times/min

TypeSwitching capacityNumber of operations
1 Form A5 A 125 V ACMin. $2 \times 10^{5}$
5 A 250 V ACMin. $10^{5}$
3 A 30 V DCMin. $10^{5}$

Tested sample:ALDP112, 6 pcs.Operation frequency:20 times/min.(ON:OFF=1.5s:1.5s)Ambient temperature:20℃Circuit:

REFERENCE DATA

1.Max. switching capacity

Change of operate and release voltage
Change of contact resistance

3-1.Operate time

2.Coil temperature characteristics (Average)

4.Electrical life test (5A 250 V AC Resistive load)

DIMENSIONS

CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website.

CAD

LD-P relay external dimensions, recommended PC board pattern (bottom view) and schematic (bottom view), datasheet page 4

Transcription of the page 4 drawing (unit: mm; the drawing is vector artwork with no text layer, transcribed by Embedr from ASCTB193E 202010):

External dimensions

Item Value
Body length Max. 20.5
Body width Max. 7.2
Body height (seated) Max. 15.3
Base dimensions at the terminals 0.4 (standoff step) and 3.4 (terminal projection), as dimensioned in the side view
Terminal cross-section 0.4 x 0.8 (0.4 marked "dia." in the side view, 0.8 in the end view)
Coil terminal column from body end 1.05
Terminal row from body side 1.15

Recommended PC board pattern (BOTTOM VIEW), tolerance ±0.1

Item Value
Holes 4 x 1.1 dia.
Coil terminal to inner contact terminal (along the row) 11.5
Inner contact terminal to outer contact terminal 7
Coil terminal pitch (perpendicular to the row) 4.7
Row to body edge (reference) (1.15)
Coil column to body end (reference) (1.05)

Schematic (BOTTOM VIEW): the coil occupies the two terminals of the 4.7 mm column (coil is not polarized). The contact is 1 Form A: the moving contact arm is drawn on the inner contact terminal (11.5 mm from the coil column) and the fixed normally open contact on the outer terminal (18.5 mm from the coil column).

Unit: mm

General tolerance

Less than 1mm:±0.1

Min. 1mm less than 3mm:±0.2

Min. 3mm:±0.3

SAFETY STANDARDS

UL/C-UL (Recognized)

File No.Contact ratingOperationsAmbient temperature
E430286 A 277 V AC $5 \times 10^{4}$ -
5 A 277 V AC Resistive $10^{5}$ 85°C
5 A 277 V AC Resistive (Class F only) $5 \times 10^{4}$ 105°C
5 A 30 V DC Resistive $10^{5}$ -
3 A 277 V AC General Use $12 \times 10^{4}$ 85°C
Pilot Duty C 300 $10^{5}$ 85°C
Pilot Duty 0.65 A 277 V AC (Inrush 6.5 A) $10^{5}$ 85°C

*Pilot Duty is in accordance with the conditions of UL508

VDE (Certified)

File No.Contact ratingOperationsAmbient temperature
400143845 A 250 V AC (cosφ = 1.0) $10^{5}$ 85°C
5 A 250 V AC (cosφ = 1.0)(Class F only) $5 \times 10^{4}$ 105°C
5 A 30 V DC (0 ms) $10^{4}$ 25°C

CSA (Certified)

CSA standard certified by C-UL

CQC (Certified)

File No.Contact ratingAmbient temperature
CQC100020486115 A 250 V AC85°C

Note: Excluding Class F insulation

INSULATION CHARACTERISTICS (IEC61810-1)

ItemCharacteristics
Clearance/Creepage distance (IEC61810-1)Min. 5.5 mm/5.5 mm
Category of protection (IEC61810-1)RT III
Tracking resistance (IEC60112)PTI 175
Insulation material groupIII a
Over voltage categoryIII
Rated voltage250 V
Pollution degree32
Type of insulation (Between contact and coil)Basic insulationReinforced insulation
Type of insulation (Between open contacts)Micro disconnection

Note: EN/IEC VDE Certified.

GUIDELINES FOR USAGE

For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions\_use/index.jsp

Cautions for usage of LD-P relays

Max. applied voltage and temperature rise

Proper usage requires that the rated voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum applied voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog.

Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE

For cautions for use, please read “GUIDELINES FOR RELAY USAGE”. https://industrial.panasonic.com/ac/e/control/relay/cautions\_use/index.jsp

Precautions for Coil Input

Long term current carrying

A circuit that will be carrying a current continuously for long periods without relay switching operation. (circuits for emergency lamps, alarm devices and error inspection that, for example, revert only during malfunction and output warnings with form B contacts) Continuous, long-term current to the coil will facilitate deterioration of coil insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type latching relay. If you need to use a single stable relay, use a sealed type relay that is not easily afected by ambient conditions and make a failsafe circuit design that considers the possibility of contact failure or disconnection.

DC Coil operating power

Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%.

However, please check with the actual circuit since the electrica characteristics may vary. The rated coil voltage should be applied to the coil and the set/reset pulse time of latching type relay difers for each relays, please refer to the relay's individual specifications.

Coil connection

When connecting coils of polarized relays, please check coil polarity (+,-) at the internal connection diagram (Schematic). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and so on, and circuit do not work. Avoid impressing voltages to the set coil and reset coil at the same time.

Ambient Environment

Usage, Transport, and Storage Conditions

During usage, storage, or transportation, avoid locations subjected to direct sunlight and maintain normal temperature, humidity and pressure conditions.

Temperature/Humidity/Pressure

When transporting or storing relays while they are tube packaged, there are cases the temperature may difer from the allowable range. In this case be sure to check the individual specifications. Also allowable humidity level is influenced by temperature, please check charts shown below and use relays within mentioned conditions. (Allowable temperature values difer for each relays, please refer to the relay's individual specifications.)

1) Temperature:

The tolerance temperature range difers for each relays, please refer to the relay’s individual specifications

  1. Humidity: 5 to 85 % RH

  2. Pressure: 86 to 106 kPa


Ambient temperature(℃)

Maximum allowable voltage and temperature rise

Proper usage requires that the rated coil voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum continuous voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog.

Operate voltage change due to coil temperature rise

In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the pick-up voltage will become somewhat higher. Also, it will be the same as using it in a higher temperature atmosphere. The resistance/temperature relationship for copper wire is about 0.4% for 1°C, and with this ratio the coil resistance increases. That is, in order to operate of the relay, it is necessary that the voltage be higher than the pick-up voltage and the pick-up voltage rises in accordance with the increase in the resistance value. However, for some polarized relays, this rate of change is considerably smaller.

Dew condensation

Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation causes the failures like insulation deterioration, wire disconnection and rust etc.

Panasonic Corporation does not guarantee the failures caused by condensation.

The heat conduction by the equipment may accelerate the cooling of device itself, and the condensation may occur.

Please conduct product evaluations in the worst condition of the actual usage. (Special attention should be paid when high temperature heating parts are close to the device. Also please consider the condensation may occur inside of the device.)

Icing

Condensation or other moisture may freeze on relays when the temperature become lower than 0°C.This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Corporation does not guarantee the failures caused by the icing.

The heat conduction by the equipment may accelerate the cooling of relay itself and the icing may occur. Please conduct product evaluations in the worst condition of the actual usage.

Low temperature and low humidity

The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time.

High temperature and high humidity

Storage for extended periods of time (including transportation periods) at high temperature or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported.

Package

In terms of the packing format used, make every efort to keep the efects of moisture, organic gases and sulfide gases to the absolute minimum.

Silicon

When a source of silicone substances (silicone rubber, silicone oil, silicone coating materials and silicone filling materials etc.) is used around the relay, the silicone gas (low molecular siloxane etc.) may be produced.

This silicone gas may penetrate into the inside of the relay. When the relay is kept and used in this condition, silicone compound may adhere to the relay contacts which may cause the contact failure. Do not use any sources of silicone gas around the relay (Including plastic seal types).

Others

Cleaning

• Although the environmentally sealed type relay (plastic sealed type, etc.) can be cleaned, avoid immersing the relay into cold liquid (such as cleaning solvent) immediately after soldering. Doing so may deteriorate the sealing performance.

NOx Generation

When relay is used in an atmosphere high in humidity to switch a load which easily produces an arc, the NOx created by the arc and the water absorbed from outside the relay combine to produce nitric acid.

This corrodes the internal metal parts and adversely afects operation.

Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use at high humidity is unavoidable, please contact our sales representative.

• Cleaning with the boiling method is recommended(The temperature of cleaning liquid should be 40°C or lower ). Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may cause breaks in the coil or slight sticking of the contacts due to ultrasonic energy.

Please refer to "the latest product specifications"

when designing your product.

•Requests to customers:

https://industrial.panasonic.com/ac/e/salespolicies/

Please contact ..........

Extracted Images

Figures and diagrams from the PDF

Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.

Agent APIs

Use this datasheet from any agent

Send the page, markdown, chunks, or search endpoint to ChatGPT, Claude, embedr-app, or your own tooling.