G5Q-1A4 DC5
Miniature sealed PCB power relay with SPST-NO contact form, 5 VDC coil, and 10 A switching capacity.
A Miniature Power Relay with 1-pole 10A Switching Capacity
• Excellent switching performance for a variety of loads.
• Small, yet provides 8-kV impulse withstand voltage (between coil and contacts).
• Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)
• Coil insulation system: Class F (UL1446).
• IEC/EN 60335-1 conformed. (-HA Model)
• Reduced power consumption with voltage holding and pulse width modulation (PWM) control (Only for G5Q-@-PW model)

RoHS Compliant
■Model Number Legend
Number of Poles 1 : 1-pole
Classification
None : Standard
- Contact Form
EU : High-capacity
None : SPDT (1c)
- Market Code
A : SPST-NO (1a)
- Enclosure Rating
None : Flux protection 4 : Sealed
None : General purpose HA : Home Appliance according to IEC/EN60335-1
None : Not supported
- Special Requirement
PW : Supported
■Application Examples
• Ideal for output applications of control equipment.
■Ordering Information
| Terminal Shape | Market Code | Classification | Contact Form | Enclosure Rating | Model | Rated Coil Voltage | Minimum Packing Unit |
| PCB terminals | General purpose | Standard | SPST-NO(1a) | Flux protection | G5Q-1A | 5VDC9VDC12VDC24VDC | 100 pcs/tray |
| G5Q-1A-PW | 5VDC12VDC24VDC | ||||||
| Sealed | G5Q-1A4 | 5VDC9VDC12VDC24VDC | |||||
| SPDT(1c) | Flux protection | G5Q-1 | 5VDC9VDC12VDC24VDC | ||||
| G5Q-1-PW | 5VDC12VDC24VDC | ||||||
| Sealed | G5Q-14 | 5VDC9VDC12VDC24VDC | |||||
| High-capacity | SPST-NO(1a) | Flux protection | G5Q-1A-EU | 5VDC12VDC24VDC | |||
| Sealed | G5Q-1A4-EU | ||||||
| SPDT(1c) | Flux protection | G5Q-1-EU | |||||
| Sealed | G5Q-14-EU | ||||||
| Home Appliance | Standard | SPST-NO(1a) | Flux protection | G5Q-1A-HA | 5VDC12VDC24VDC | ||
| G5Q-1A-HA-PW | |||||||
| High-capacity | G5Q-1A-EU-HA | 12VDC24VDC | |||||
| Standard | SPDT(1c) | G5Q-1-HA | 5VDC12VDC24VDC | ||||
| G5Q-1-HA-PW | |||||||
| High-capacity | G5Q-1-EU-HA | 12VDC24VDC |
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A DC5
Rated coil voltage
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).
■Ratings
●Coil
| Contact form | Rated voltage | Rated current (mA) | Coil resistance (Ω) | Must operate voltage (V) | Must release voltage (V) | Max. voltage (V) | Power consumption (mW) |
| SPST-NO (1a) | 5 VDC | 40 | 125 | 75% max. | 5% min. 5 to 34%* | 190% (at 23°C) | Approx. 200 Approx. 32* |
| 9 VDC | 22.2 | 405 | |||||
| 12 VDC | 16.7 | 720 | |||||
| 24 VDC | 8.3 | 2880 | |||||
| SPDT (1c) | 5 VDC | 80 | 63 | 5% min. 5 to 25%* | Approx. 400 Approx. 36* | ||
| 9 VDC | 44.4 | 202 | |||||
| 12 VDC | 33.3 | 360 | |||||
| 24 VDC | 16.7 | 1440 |
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage)
●Contacts
| LoadItem | Resistive load | |||
| SPST-NO (1a) | SPDT (1c) | |||
| Standard | High-capacity | Standard | High-capacity | |
| Contact type | Single | |||
| Contact material | Ag-Alloy (Cd free) | |||
| Rated load(resistive) | 10 A at 125 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC | 10 A at 250 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC | 10 A at 125 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC) | 10 A at 250 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC) |
| Rated carry current | 10 A (NO)/3 A (NC) | |||
| Max. switching voltage | 277 VAC, 30 VDC | |||
| Max. switching current | AC: 10 A (NO)/3 A (NC)DC: 5 A (NO)/3 A (NC) | |||
■Characteristics
| Item Classification | Standard model | |
| Contact resistance *1 | 100 mΩ max. | |
| Operate time | 10 ms max. | |
| Release time | 5 ms max. | |
| Insulation resistance *2 | 1,000 MΩ min. | |
| Dielectric strength | Between coil and contacts | 4,000 VAC, 50/60 Hz for 1 min |
| Between contacts of the same polarity | 1,000 VAC, 50/60 Hz for 1 min | |
| Impulse withstand voltage (between coil and contacts) | 8 kV (1.2 x 50 μs) | |
| Vibration resistance | Destruction | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
| Malfunction | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) | |
| Shock resistance | Destruction | 1,000 m/s2 |
| Malfunction | 100 m/s2 | |
| Durability | Mechanical | 10,000,000 operations (18,000 operations per hour) |
| Electrical | NO25,000 operations: 10 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)50,000 operations: 10 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)50,000 operations: 5 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 5 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec)NC200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec) | |
| Failure rate (P level) (reference *3) | 10 mA at 5 VDC | |
| Ambient operating temperature | -40°C to 105°C (with no icing or condensation)-40°C to 85°C (with no icing or condensation) | |
| Ambient operating humidity | 5% to 85% | |
| Weight | Approx. 6.5 g | |
Note. Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*3. This value was measured at a switching frequency of 120 operations/min.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.

Switching voltgate (V)
●Shock Malfunction
■Engineering Data
●Maximum Switching Capacity
●Ambient Temperature VS. Maximum Coil Voltage



Sample: G5Q-14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. The energized voltage is 100% of the rated voltage. Requirement: None malfuction 100 m/s2
Note. The Maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
■Dimensions
(Unit: mm)
■Approved Standards
UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)
| Model | Contact form | Coil ratings | Contact ratings | Number of test operations |
| G5Q-1A(4)(-EU)(-HA)(-PW)G5Q-1(4)(-EU)(-HA)(-PW) | SPST-NO (1a)SPDT (1c) | 5 to 48 VDC | 10 A 250 VAC N.O. only (Resistive) 40°C | 6,000 |
| 10 A 30 VDC N.O. only (Resistive) 40°C | ||||
| 4 A 120 VAC N.O. only (Resistive) 40°C | 100,000 | |||
| 3 A 250 VAC N.C. only (Resistive) 40°C | 6,000 | |||
| 3 A 30 VDC N.C. only (Resistive) 40°C |
EN/IEC, VDE (Certified/No.40009467)
| Model | Contact form | Coil ratings | Contact ratings | Number of test operations |
| G5Q-1(4)(-HA)(-PW)G5Q-1A(4)(-HA)(-PW) | SPST-NO (1a)SPDT (1c) | 5 to 48 VDC | 10 A making and 0 A breaking, 250 VAC ( $\cos\phi=1$ ) 105°C5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C | 10,000 |
| 5 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 105°C | 75,000 | |||
| G5Q-1A(4)-EU(-HA)G5Q-1(4)-EU(-HA) | 10 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 65°C5 A 30 VDC (0 ms) (N.O.) 65°C3 A 30 VDC (0 ms) (N.C.) 65°C | 10,000 | ||
| 4 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 85°C | 100,000 |
| Creepage Distance | 6.4 mm min. |
| Clearance Distance | 5.5 mm min. |
| Insulation Material Group | IIIa |
| Type of Insulation Coil-contact CircuitOpen Contact Circuit | Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)Micro disconnection |
| Rated Insulation Voltage | 250 V |
| Pollution Degree | 2 |
| Rated Voltage System | 250 V / 400 V (EU flux type only) |
| Over Voltage Category | III |
| Category of Protection according to IEC 61810-1 | RT II (Flux protection) / RT III (Sealed) |
| Glow Wire according to IEC 60335-1 | <HA Models only>GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12) |
| Tracking Index of Relay Base | PTI 250 V min. (housing parts) |
| Flammability Class according to UL94 | V-0 |
| Coil Insulation System | F Class (UL 1446) |
| Regional Contact | |
| Americas | Europe |
| https://www.components.omron.com/ | http://components.omron.eu/ |
| Asia-Pacific | China |
| https://ecb.omron.com.sg/ | https://www.ecb.omron.com.cn/ |
| Korea | Japan |
| https://www.omron-ecb.co.kr/ | https://www.omron.co.jp/ecb/ |
© OMRON Corporation 2007-2021 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice.
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Coil Voltage Reduction (Holding Voltage) after Relay operation
• If the coil voltage is reduced to the holding voltage after relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below.
• A voltage of at least 40% (G5Q-1A type) /30% (G5Q-1 type) of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level.
G5Q-1A
G5Q-1
G5Q-1A
| Applied coil voltage | Coil resistance* | Power consumption | |
| Rated voltage | 100% | 125Ω (5 VDC)720Ω (12 VDC)2,880Ω (24 VDC) | Approx. 200 mW |
| Holding voltage | 40% | Approx. 32 mW |
The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.
G5Q-1
| Applied coil voltage | Coil resistance* | Power consumption | |
| Rated voltage | 100% | 63Ω (5 VDC) | Approx. 400 mW |
| 360Ω (12 VDC) | |||
| Holding voltage | 30% | 1,440Ω (24 VDC) | Approx. 36 mW |
The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.
■Example of drive circuit
Please check each region's Terms & Conditions by region website.
OMRON Corporation Electronic and Mechanical Components Company
●Power consumption reduction of coil with pulse width modulation (PWM)
• Models with PWM drive capability (-PW) can reduce coil holding current with PWM control. This function reduces power consumption by reducing the current held by coil.
• Apply the rated voltage for at least 100 ms at the time of relay operation.
• The following are our verification conditions. When using, it be sure to check the actual machine under the actual usage conditions.
■Conditions of validation carried out by OMRON

• Applied voltage: rated voltage
• Duty: 50% or more
• Frequency: 10 kHz or more
• Diode Vf: 0.4 V or less