Miniature sealed PCB power relay with SPST-NO contact form, 5 VDC coil, and 10 A switching capacity.

Electromechanical relayG5Q-1A4 DC5G5QPCB terminals

A Miniature Power Relay with 1-pole 10A Switching Capacity

• Excellent switching performance for a variety of loads.

• Small, yet provides 8-kV impulse withstand voltage (between coil and contacts).

• Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)

• Coil insulation system: Class F (UL1446).

• IEC/EN 60335-1 conformed. (-HA Model)

• Reduced power consumption with voltage holding and pulse width modulation (PWM) control (Only for G5Q-@-PW model)

RoHS Compliant

■Model Number Legend

  1. Number of Poles 1 : 1-pole

  2. Classification

None : Standard

  1. Contact Form

EU : High-capacity

None : SPDT (1c)

  1. Market Code

A : SPST-NO (1a)

  1. Enclosure Rating

None : Flux protection 4 : Sealed

None : General purpose HA : Home Appliance according to IEC/EN60335-1

None : Not supported

  1. Special Requirement

PW : Supported

■Application Examples

• Ideal for output applications of control equipment.

■Ordering Information

Terminal ShapeMarket CodeClassificationContact FormEnclosure RatingModelRated Coil VoltageMinimum Packing Unit
PCB terminalsGeneral purposeStandardSPST-NO(1a)Flux protectionG5Q-1A5VDC9VDC12VDC24VDC100 pcs/tray
G5Q-1A-PW5VDC12VDC24VDC
SealedG5Q-1A45VDC9VDC12VDC24VDC
SPDT(1c)Flux protectionG5Q-15VDC9VDC12VDC24VDC
G5Q-1-PW5VDC12VDC24VDC
SealedG5Q-145VDC9VDC12VDC24VDC
High-capacitySPST-NO(1a)Flux protectionG5Q-1A-EU5VDC12VDC24VDC
SealedG5Q-1A4-EU
SPDT(1c)Flux protectionG5Q-1-EU
SealedG5Q-14-EU
Home ApplianceStandardSPST-NO(1a)Flux protectionG5Q-1A-HA5VDC12VDC24VDC
G5Q-1A-HA-PW
High-capacityG5Q-1A-EU-HA12VDC24VDC
StandardSPDT(1c)G5Q-1-HA5VDC12VDC24VDC
G5Q-1-HA-PW
High-capacityG5Q-1-EU-HA12VDC24VDC

Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A DC5
Rated coil voltage
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).

■Ratings

●Coil

Contact formRated voltageRated current (mA)Coil resistance (Ω)Must operate voltage (V)Must release voltage (V)Max. voltage (V)Power consumption (mW)
SPST-NO (1a)5 VDC4012575% max.5% min. 5 to 34%*190% (at 23°C)Approx. 200 Approx. 32*
9 VDC22.2405
12 VDC16.7720
24 VDC8.32880
SPDT (1c)5 VDC80635% min. 5 to 25%*Approx. 400 Approx. 36*
9 VDC44.4202
12 VDC33.3360
24 VDC16.71440

Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage)

●Contacts

LoadItemResistive load
SPST-NO (1a)SPDT (1c)
StandardHigh-capacityStandardHigh-capacity
Contact typeSingle
Contact materialAg-Alloy (Cd free)
Rated load(resistive)10 A at 125 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC10 A at 250 VAC3 A at 125 VAC5 A at 250 VAC3 A at 250 VAC5 A at 30 VDC10 A at 125 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC)10 A at 250 VAC (NO)3 A at 125 VAC (NO)5 A at 250 VAC (NO)3 A at 250 VAC (NO)5 A at 30 VDC (NO)3 A at 125 VAC (NC)3 A at 250 VAC (NC)3 A at 30 VDC (NC)
Rated carry current10 A (NO)/3 A (NC)
Max. switching voltage277 VAC, 30 VDC
Max. switching currentAC: 10 A (NO)/3 A (NC)DC: 5 A (NO)/3 A (NC)

■Characteristics

Item ClassificationStandard model
Contact resistance *1100 mΩ max.
Operate time10 ms max.
Release time5 ms max.
Insulation resistance *21,000 MΩ min.
Dielectric strengthBetween coil and contacts4,000 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage (between coil and contacts)8 kV (1.2 x 50 μs)
Vibration resistanceDestruction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistanceDestruction1,000 m/s2
Malfunction100 m/s2
DurabilityMechanical10,000,000 operations (18,000 operations per hour)
ElectricalNO25,000 operations: 10 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)50,000 operations: 10 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 3 sec)200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)50,000 operations: 5 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 5 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec)NC200,000 operations: 3 A at 125 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 250 VAC resistive load(operation: ON for 1 sec, OFF for 1 sec)100,000 operations: 3 A at 30 VDC resistive load(operation: ON for 1 sec, OFF for 1 sec)
Failure rate (P level) (reference *3)10 mA at 5 VDC
Ambient operating temperature-40°C to 105°C (with no icing or condensation)-40°C to 85°C (with no icing or condensation)
Ambient operating humidity5% to 85%
WeightApprox. 6.5 g

Note. Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*3. This value was measured at a switching frequency of 120 operations/min.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.


Switching voltgate (V)

●Shock Malfunction
■Engineering Data
●Maximum Switching Capacity

●Ambient Temperature VS. Maximum Coil Voltage


Sample: G5Q-14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. The energized voltage is 100% of the rated voltage. Requirement: None malfuction 100 m/s2
Note. The Maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.

■Dimensions
(Unit: mm)

■Approved Standards

UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)

ModelContact formCoil ratingsContact ratingsNumber of test operations
G5Q-1A(4)(-EU)(-HA)(-PW)G5Q-1(4)(-EU)(-HA)(-PW)SPST-NO (1a)SPDT (1c)5 to 48 VDC10 A 250 VAC N.O. only (Resistive) 40°C6,000
10 A 30 VDC N.O. only (Resistive) 40°C
4 A 120 VAC N.O. only (Resistive) 40°C100,000
3 A 250 VAC N.C. only (Resistive) 40°C6,000
3 A 30 VDC N.C. only (Resistive) 40°C

EN/IEC, VDE (Certified/No.40009467)

ModelContact formCoil ratingsContact ratingsNumber of test operations
G5Q-1(4)(-HA)(-PW)G5Q-1A(4)(-HA)(-PW)SPST-NO (1a)SPDT (1c)5 to 48 VDC10 A making and 0 A breaking, 250 VAC ( $\cos\phi=1$ ) 105°C5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C10,000
5 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 105°C75,000
G5Q-1A(4)-EU(-HA)G5Q-1(4)-EU(-HA)10 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 65°C5 A 30 VDC (0 ms) (N.O.) 65°C3 A 30 VDC (0 ms) (N.C.) 65°C10,000
4 A 250 VAC ( $\cos\phi=1$ ) (N.O.) 85°C100,000
Creepage Distance6.4 mm min.
Clearance Distance5.5 mm min.
Insulation Material GroupIIIa
Type of Insulation Coil-contact CircuitOpen Contact CircuitBasic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)Micro disconnection
Rated Insulation Voltage250 V
Pollution Degree2
Rated Voltage System250 V / 400 V (EU flux type only)
Over Voltage CategoryIII
Category of Protection according to IEC 61810-1RT II (Flux protection) / RT III (Sealed)
Glow Wire according to IEC 60335-1<HA Models only>GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Tracking Index of Relay BasePTI 250 V min. (housing parts)
Flammability Class according to UL94V-0
Coil Insulation SystemF Class (UL 1446)
Regional Contact
AmericasEurope
https://www.components.omron.com/http://components.omron.eu/
Asia-PacificChina
https://ecb.omron.com.sg/https://www.ecb.omron.com.cn/
KoreaJapan
https://www.omron-ecb.co.kr/https://www.omron.co.jp/ecb/

© OMRON Corporation 2007-2021 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice.

■Precautions

●Please refer to “PCB Relays Common Precautions” for correct use.

Correct Use

●Coil Voltage Reduction (Holding Voltage) after Relay operation

• If the coil voltage is reduced to the holding voltage after relay operation, first apply the rated voltage to the coil for at least 100 ms, as shown below.

• A voltage of at least 40% (G5Q-1A type) /30% (G5Q-1 type) of the rated voltage is required for the coil holding voltage. Do not allow voltage fluctuations to cause the coil holding voltage to fall below this level.

G5Q-1A

G5Q-1

G5Q-1A

Applied coil voltageCoil resistance*Power consumption
Rated voltage100%125Ω (5 VDC)720Ω (12 VDC)2,880Ω (24 VDC)Approx. 200 mW
Holding voltage40%Approx. 32 mW

The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.

G5Q-1

Applied coil voltageCoil resistance*Power consumption
Rated voltage100%63Ω (5 VDC)Approx. 400 mW
360Ω (12 VDC)
Holding voltage30%1,440Ω (24 VDC)Approx. 36 mW

The coil resistance were measured at a coil temperature of 23°C with tolerances of ±10%.
■Example of drive circuit

Please check each region's Terms & Conditions by region website.

OMRON Corporation Electronic and Mechanical Components Company

●Power consumption reduction of coil with pulse width modulation (PWM)

• Models with PWM drive capability (-PW) can reduce coil holding current with PWM control. This function reduces power consumption by reducing the current held by coil.

• Apply the rated voltage for at least 100 ms at the time of relay operation.

• The following are our verification conditions. When using, it be sure to check the actual machine under the actual usage conditions.

■Conditions of validation carried out by OMRON

• Applied voltage: rated voltage

• Duty: 50% or more

• Frequency: 10 kHz or more

• Diode Vf: 0.4 V or less