Datasheet docs

Infineon Technologies

DPS310

Digital barometric pressure and temperature sensor with 24-bit resolution, FIFO, and low power consumption.

Digital barometric pressure sensorDPS310XENSIVPG-VLGA-8-1, 8-pin LGA, 2.0 x 2.5 x 1.0 mmI2CSPI

DPS310

Digital XENSIVTM Barometric Pressure Sensor for Portable Devices

Product Description

The DPS310 is a miniaturized Digital Barometric Air Pressure Sensor with a high accuracy and a low current consumption, capable of measuring both pressure and temperature. The pressure sensor element is based on a capacitive sensing principle which guarantees high precision during temperature changes. The small package makes the DPS310 ideal for mobile applications and wearable devices.

The internal signal processor converts the output from the pressure and temperature sensor elements to 24 bit results. Each unit is individually calibrated, the calibration coeficients calculated during this process are stored in the calibration registers. The coeficients are used in the application to convert the measurement results to high accuracy pressure and temperature values. The result FIFO can store up to 32 measurement results, allowing for a reduced host processor polling rate. Sensor measurements and calibration coeficients are available through the serial I2C or SPI interface. The measurement status is indicated by status bits or interrupts on the SDO pin.

Features

• Operation range: Pressure: 300 –1200 hPa. Temperature: -40 – 85 °C.

• Pressure sensor precision: ± 0.002 hPa (or ±0.02 m) (high precision mode).

• Relative accuracy: ± 0.06 hPa (or ±0.5 m)

• Absolute accuracy: ± 1 hPa (or ±8 m)

• Temperature accuracy: ± 0.5°C.

• Pressure temperature sensitivity: 0.5Pa/K

Measurement time: Typical: 27.6 ms for standard mode (16x). Minimum: 3.6 ms for low precision mode.

Average current consumption: 1.7 µA for Pressure Measurement, 1.5uA for Temperature measurement @1Hz sampling rate, Standby: 0.5 µA.

• Supply voltage: VDDIO: 1.2 – 3.6 V, VDD: 1.7 – 3.6 V.

• Operating modes: Command (manual), Background (automatic), and Standby.

• Calibration: Individually calibrated with coeficients for measurement correction.

• FIFO: Stores up to 32 pressure or temperature measurements.

• Interface: I2C and SPI (both with optional interrupt)

• Package dimensions: 8-pin LGA, 2.0 mm x 2.5 mm x 1.0 mm.

• Green Product (RoHS) Compliant

Typical Applications

• Indoor Navigation (floor detection e.g. in shopping malls and parking garages)

• Health and Sports (accurate elevation gain and vertical speed)

• Outdoor Navigation (GPS start-up time and accuracy improvement, dead-reckoning e.g. in tunnels)

• Weather Station('Micro-weather' and local forecasts)

• HDD drivers, (leak rate detection in hard disk drives)

• Drones (flight stability and height control)

Table of contents

Table of contents

Product Description .... 1
Features .... 1
Typical Applications .... 1
Table of contents .... 2
1 Definitions, acronyms and abbreviations .... 4
1.1 Definitions .... 4
2 Pin Configuration and Block Diagram .... 5
2.1 Pin Configuration and Description .... 5
2.2 Block Diagram .... 6
3 Specifications .... 6
3.1 Operating Range .... 6
3.2 Absolute Maximum Ratings .... 7
3.3 Current Consumption .... 7
3.4 Temperature Transfer Function .... 8
3.5 Pressure Transfer Function .... 9
3.6 Timing Characteristics .... 10
4 Functional Description .... 10
4.1 Operating Modes .... 10
4.2 Mode transition diagram .... 10
4.3 Start-up sequence .... 11
4.4 Measurement Precision and Rate .... 11
4.5 Sensor Interface .... 12
4.6 Interrupt .... 12
4.7 Result Register Operation .... 13
4.8 FIFO Operation .... 13
4.9 Calibration and Measurement Compensation .... 13
4.9.1 How to Calculate Compensated Pressure Values .... 14
4.9.2 How to Calculate Compensated Temperature Values .... 14
4.9.3 Compensation Scale Factors .... 15
4.9.4 Pressure and Temperature calculation flow .... 15
5 Applications .... 17
5.1 Measurement Settings and Use Case Examples .... 17
5.2 Application Circuit Example .... 18
5.3 IIR filtering .... 19
6 Digital interfaces .... 19
6.1 I2C Interface .... 20
6.2 SPI Interface .... 20

Table of contents

6.3 Interface parameters specification....22
6.3.1 General interface parameters....22
6.3.1.1 I2C timings....22
6.3.1.2 SPI timings....24
7 Register Map....25
8 Register description....25
8.1 Pressure Data (PRS_Bn)....25
8.1.1 PRS_B2....26
8.1.2 PRS_B1....26
8.1.3 PRS_B0....27
8.2 Temperature Data (TMP_Tn)....27
8.2.1 TMP_B2....27
8.2.2 TMP_B1....28
8.2.3 TMP_B0....28
8.3 Pressure Configuration (PRS_CFG)....29
8.4 Temperature Configuration(TMP_CFG)....31
8.5 Sensor Operating Mode and Status (MEAS_CFG)....32
8.6 Interrupt and FIFO configuration (CFG_REG)....33
8.7 Interrupt Status (INT_STS)....34
8.8 FIFO Status (FIFO_STS)....35
8.9 Soft Reset and FIFO flush (RESET)....36
8.10 Product and Revision ID (ID)....36
8.11 Calibration Coefficients (COEF)....37
8.12 Coefficient Source....38
9 Package Dimensions....38
10 Package Handling....38
11 Reflow soldering and board assembly....38
Revision History....40
Known Issues List....40
Disclaimer....41

Definitions, acronyms and abbreviations

1 Definitions, acronyms and abbreviations

1.1 Definitions

An explanation of terms and definitions used in this datasheet.

Table 1

TermDefinition/explanation
Absolute accuracyThe absolute measurement accuracy over the entire measurement range.
Digital bit depthThe total bit depth used for conversion of the sensor input to the digital output. Measured in bits.
Digital resolutionThe pressure value represented by the LSB change in output. This value should be much smaller than the sensor noise.
Full Scale Range (FSR)The peak-to-peak measurement range of the sensor.
LSBLeast Significant Bit
Measurement timeThe time required to acquire one sensor output result. This value determines the maximum measurement rate.
MSBMost Significant Bit
Non-linearityThe deviation of measured output from the best-fit straight line, relative to 1000 hPa and 25 °C.
Output compensationThe process of applying an algorithm to the sensor output to improve the absolute accuracy of the sensor across temperature and to minimize unit to unit output variation. This algorithm makes use of both the temperature sensor readings and the individual calibration coefficients.
Precision (noise)The smallest measurable change, expressed as rms, after sensor oversampling.
Pressure temperature coefficientThe pressure measurement deviation, after compensation, from expected measurement value due to temperature change from 25 °C. Measured in Pa/K.
Sensor calibrationThe process, during the production test, where the sensor's measurement results are compared against reference values, and a set of calibration coefficients are calculated from the deviation. The coefficients are stored in the sensor's memory and are used in the output compensation.
Sensor oversampling rate (OSR)Specifies the number of sensor measurements used internally to generate one sensor output result.

Pin Configuration and Block Diagram

2

Pin Configuration and Block Diagram

2.1

Pin Configuration and Description


Figure 1 Pin configuration (top view, figure not to scale)

Table 2
Pin description

PinNameSPI 3-wireSPI 3-wire with interruptSPI 4-wire $I^{2}C$ $I^{2}C$ with interrupt
1GNDGround
2CSBChip select - active lowChip select - active lowChip select - active lowNot used - open (internal pull-up) or tie to VDDIONot used - open (internal pull-up) or tie to VDDIO
3SDISerial data in/outSerial data in/outSerial data inSerial data in/outSerial data in/out
4SCKSerial Clock
5SDONot usedInterruptSerial data outLeast significant bit in the device address.Interrupt pin and least significant bit in the device address.
6VDDIODigital supply voltage for digital blocks and I/O interface
7GNDGround
8VDDSupply voltage for analog blocks

Specifications

2.2

Block Diagram

Figure 2

3 Specifications

3.1 Operating Range

The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections refer to these operating conditions, unless noted otherwise.

Table 3 Operating Range

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Pressure $P_a$ 3001200hPa
Temperature $T_a$ -4085°C
Supply voltage $V_{DD}$ 1.73.6V
Supply voltage IO $V_{DDIO}$ 1.23.6V
Supply voltage ramp-up time $t_{vddup}$ 0.0015msTime for supply voltage to reach 90% of final value.
Solder $drift^{1)}$ 0.8hPaMinimum solder height 50um.
Long term stability±1hPaDepending on environmental conditions.

Specifications

3.2 Absolute Maximum Ratings

Maximum ratings are absolute ratings. Exceeding any one of these values may cause irreversible damage to the integrated circuit.

Attention: Stresses above the values listed as "Absolute Maximum Ratings" may cause permanent damage to the devices. Exposure to absolute maximum rating conditions for extended periods may afect device reliability.

Table 5 Current Consumption
Table 4 Absolute Maximum Ratings

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
$V_{DD}$ and $V_{DDIO}$ $V_{DDxx\_max}$ 4V
Voltage on any pin $V_{max}$ 4V
Storage temperature $T_s$ -40125°C
Pressure $P_{max}$ 10,000hPa
ESD $V_{ESD\_HBM}$ -22KVHBM (JS001)

3.3 Current Consumption

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } } { = } 1 0 0 0 \mathsf { h P a }$ and $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$ . Max./Min. values $( \mathsf { P _ { A } } \mathsf { = 9 5 0 } \mathsf { - 1 0 5 0 } \mathsf { h P a }$ and ${ \mathsf { T } } _ { \mathsf { A } } { = } 0 \ldots { + } 6 5 ^ { \circ } { \mathsf { C } } )$

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Peak Current Consumption $I_{peak}$ 345μAduring Pressure measurement
280μAduring Temperature measurement
Standby Current Consumption $I_{stb}$ 0.5μA
Current Consumption.(1 pressure and temperature measurements per second.) $I_{1Hz}$ 2.1μALow precision
11Standard precision
38High precision

Note: The current consumption depends on both pressure measurement precision and rate. Please refer to the Pressure Configuration (PRS_CFG) register description for an overview of the current consumption in diferent combinations of measurement precision and rate.

Specifications

3.4

Temperature Transfer Function

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } { = } 1 0 0 0 h P a a n c }$ $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$ . Max./Min. values $( \mathsf { P _ { A } } \mathsf { = 9 5 0 - 1 0 5 0 } \mathsf { h P a }$ and ${ \mathsf { T } } _ { \mathsf { A } } { = } 0 \ldots { + } 6 5 ^ { \circ } { \mathsf { C } } )$

Table 6
Temperature Transfer Function

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Temperature accuracy $A_t$ +/-0.5°C
Temperature data resolution $A_{t\_res}$ 0.01°C
Temperature measurement ratef1128Hz

Specifications

3.5 Pressure Transfer Function

Test conditions (unless otherwise specified in the table): $\mathsf { V } _ { \mathsf { D D } } \mathsf { = } 1 . 8 \mathsf { V }$ and $\mathsf { V } _ { \mathsf { D D I O } } = 1 . 8 \mathsf { V } .$ Typ. values $( \mathsf { P _ { A } } { = } 1 0 0 0 \mathsf { h P a } \mathsf { a n d }$ $\mathsf { T } _ { \mathsf { A } } { = } 2 5 ^ { \circ } \mathsf { C } )$

Pressure Transfer Function

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Absolute pressure accuracy $A_{p\_abs}$ +/-100PaPa=300 - 1200hPa; $T_A$ =0..+65°C; Excluding solder effects
Relative pressure accuracy $A_{p\_rel}$ +/-6PaAny Δ1hPa in the range Pa=800 - 1200hP; Any constant temperature in the range $T_A$ =20..+60°C
Pressure precision $A_{p\_prc}$ 1.0 $Pa_{RMS}$ Low Power
0.35Standard
0.2High Precision

Note: Pressure precision is measured as the average standard deviation. Please refer to the Pressure Configuration (PRS_CFG) register description for all precision mode options.

Power supply rejection $A_{p\_psr}$ 0.063 $Pa_{RMS}$ Measured with 217Hz square wave and broad band noise, 100mVpp
Pressure temperature sensitivity of calibrated measurements $A_{p\_tmp}$ 0.5Pa/K1000hPa, 25...+65°C.
Pressure data resolution $A_{p\_res}$ 0.06 $Pa_{RMS}$
Pressure measurement ratef1128Hz
Pressure measurement timet5.2msLow Power
27.6Standard
105High Precision

Note: The pressure measurement time (and thus the maximum rate) depends on the pressure measurement precision. Please refer to the Pressure Configuration (PRS_CFG) register description for an overview of the possible combinations of measurement precision and rate

Functional Description

3.6 Timing Characteristics

Table 8 Timing Characteristics

ParameterSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Time to sensor ready $T_{Sensor\_rdy}$ 12msThe SENSOR_RDY bit in the Measurement Configuration register will be set when the sensor is ready.
Time to coefficients are available. $T_{Coef\_rdy}$ 40msThe COEF_RDY bit in the Measurement Configuration register will be set when the coefficients can be read out.

Note: Start-up timing is measured from VDD > 1.2V & VDDIO > 0.6V or Soft Reset.

$I^{2}C$ Clock. $f_{I2C}$ 3.4MHz
SPI Clock $f_{SPI}$ 10MHz

4 Functional Description

4.1 Operating Modes

The DPS310 supports 3 diferent modes of operation: Standby, Command, and Background mode.

• Standby Mode

- Default mode after power on or reset. No measurements are performed.

- All registers and compensation coeficients are accessible.

• Command Mode

- One temperature or pressure measurement is performed according to the selected precision.

The sensor will return to Standby Mode when the measurement is finished, and the measurement result will be available in the data registers.

• Background Mode

Pressure and/or temperature measurements are performed continuously according to the selected measurement precision and rate. The temperature measurement is performed immediately after the pressure measurement.

The FIFO can be used to store 32 measurement results and minimize the number of times the sensor must be accessed to read out the results.

Note: Operation mode and measurement type are set in the Sensor Operating Mode and Status (MEAS_CFG) register.

4.2 Mode transition diagram

The mode transition diagram is shown below.

Functional Description


Figure 3 Mode transition diagram

4.3 Start-up sequence

The start-up sequence is shown below. This diagram shows when the registers are accessible for read and/or write and also when the Pressure/Temperature measurements can start.


Figure 4 Start-up sequence

4.4 Measurement Precision and Rate

Diferent applications require diferent measurement precision and measurement rates. Some applications, such as weather stations, require lower precision and measurement rates than for instance indoor navigation and sports applications.

When the sensor DPS310 is in Background Mode, the measurement precision and rate can be configured to match the requirements of the application. This reduces current consumption of the sensor and the system.

Functional Description

In order to achieve a higher precision, the sensor DPS310 will read multiple times ( oversampling ), and combine the readings into one result. This increases the current consumption and also the measurement time, reducing the maximum possible measurement rate. It is necessary to balance the accuracy and data rate required for each application with the allowable current consumption.

The measurement precision, rate and time is set in the Pressure Configuration (PRS_CFG) and Temperature Configuration(TMP_CFG) registers. The register descriptions contain information about the current consumption and the possible combinations of measurement precision, time, and rate.

Enabling temperature measurements allows for compensation of temperature drift in the pressure measurement. The rates of these measurements can be set independently, but temperature compensation is more accurate when temperature and pressure measurements are taken together. This reduces the maximum pressure measurement rate, since: Ratetemperature*Timetemperature + Ratepressure*Timepressure< 1 second. Measurement Settings and Use Case Examples contains a table with examples of combinations of pressure and temperature precision and rates for diferent use cases.

In the figure below is described the Temperature and Pressure measurements sequence in background mode.


Figure 5 Background mode temperature and pressure measurements sequence

4.5 Sensor Interface

The DPS310 can be accessed as a slave device through mode '11' SPI 3-wire, SPI 4-wire, or I2C serial interface.

• I2C interface

- The sensor's default interface.

The sensor's address is 0x77 (default) or 0x76 (if the SDO pin is pulled-down to GND).

• SPI interface

The sensor will switch to SPI configuration if it detects an active low on the CSB pin. SPI 4-wire is the default SPI interface.

To enable SPI 3-wire configuration, a bit must be set in the Interrupt and FIFO configuration (CFG_REG) register after start up.

More details about digital interfaces are available in the Digital interfaces.

4.6 Interrupt

The sensor DPS310 can generate an interrupt when a new measurement result is available and/or when the FIFO is full. The sensor uses the SDO pin for the interrupt signal, and interrupt is therefore not supported if the interface is 4-wire SPI.

The interrupt is enabled and configured in the Interrupt and FIFO configuration (CFG_REG) register. In I2C configuration the SDO pin serves as both interrupt and as the least significant bit in the device address. If the SDO pin is pulled low the interrupt polarity must be set to active high and vice-versa.

The interrupt status can be read from the Interrupt Status (INT_STS) register.

Functional Description

4.7

Result Register Operation

After starting the measurements, the latest pressure and temperature raw data will be available in their respective result registers. Temperature measurement can be skipped. The temperature measurements can be disabled if there is a requirement to measure pressure rapidly, but it will make accurate temperature drift compensation impossible.

All measurement data can be read in a single command using auto-increment read. When FIFO is disabled, reading the result register will not afect the register value, it will only be updated when a new measurement is completed. When FIFO is enabled, the pressure result register will update to the next value in the FIFO after each read. When all of the FIFO values have been read, the result register will be set to 0x800000.

4.8 FIFO Operation

The DPS310 FIFO can store the last 32 measurements of pressure or temperature. This reduces the overal system power consumption as the host processor does not need to continuously poll data from the sensor but can go into standby mode for longer periods of time.

The FIFO can store any combination of pressure and temperature results, according to the background mode measurement rate settings. The pressure rate can for instance be set 4 times higher than the temperature rate and thus only every fifth result will be a temperature result. The measurement type can be seen in the result data. The sensor will set the least significant bit to:

• '1' if the result is a pressure measurement.

• '0' if it is a temperature measurement.

The sensor uses 24 bits to store the measurement result. Because this is more bits than is needed to cover the full dynamic range of the pressure sensor, using the least significant bit to label the measurement type will not afect the precision of the result.

The FIFO can be enabled in the Interrupt and FIFO configuration register. The data from the FIFO is read out from the Pressure Data (PRS_Bn) registers regardless of whether the next result in the FIFO is a temperature or a pressure measurement.

When a measurement has been read out, the FIFO will auto increment and place the next result in the data register. A flag will be set in the FIFO Status register when the FIFO is empty and all following reads will return 0x800000.

If the FIFO is full, the FIFO_FULL bit in the FIFO Status (FIFO_STS)will be set. If the INT_FIFO bit in the Interrupt and FIFO configuration register ( CFG_REG) is set, an interrupt will also be generated when the FIFO is full. The FIFO will stop recording measurements results when it is full.

4.9

Calibration and Measurement Compensation

The sensor DPS310 is a calibrated sensor and contains calibration coeficients. These are used in the application (for instance by the host processor) to compensate the measurement results for sensor non-linearities.

The sections that follow describe how to calculate the compensated results and convert them into Pa and °C values.

Functional Description

4.9.1 How to Calculate Compensated Pressure Values

Steps

  1. Read the pressure calibration coeficients (c00, c10, c20, c30, c01, c11, and c21) from the Calibration Coeficient register.

Note: The coeficients read from the coeficient register are 2's complement numbers.

  1. Choose scaling factors kT (for temperature) and kP (for pressure) based on the chosen precision rate. The scaling factors are listed in Table 9.

  2. Read the pressure and temperature result from the registers or FIFO.

Note: The measurements read from the result registers (or FIFO) are 24 bit 2´s complement numbers. Depending on the chosen measurement rates, the temperature may not have been measured since the last pressure measurement.

  1. Calculate scaled measurement results.

$$
\begin{array}{r c l} \mathrm {T_ {raw_sc}} & = & \mathrm {T_ {raw} / kT} \ \mathrm {P_ {raw_sc}} & = & \mathrm {P_ {raw} / kP} \end{array}
$$

  1. Calculate compensated measurement results.
<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;"> $P_{\text{comp}}(\text{Pa}) = \text{c00} + P_{\text{raw\_sc}} * (\text{c10} + P_{\text{raw\_sc}} * (\text{c20} + P_{\text{raw\_sc}} * \text{c30})) + T_{\text{raw\_sc}} * \text{c01} + T_{\text{raw\_sc}} * P_{\text{raw\_sc}} * (\text{c11} + P_{\text{raw\_sc}} * \text{c21})$ </div>

4.9.2 How to Calculate Compensated Temperature Values

Steps

  1. Read the temperature calibration coeficients ( c0 and c1 ) from the Calibration Coeficients (COEF) register.

Note: The coeficients read from the coeficient register are 12 bit 2´s complement numbers.

  1. Choose scaling factor kT (for temperature) based on the chosen precision rate. The scaling factors are listed in Table 9.

  2. Read the temperature result from the temperature register or FIFO.

Note: The temperature measurements read from the temperature result register (or FIFO) are 24 bit 2´s complement numbers

Functional Description

  1. Calculate scaled measurement results.
<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;"> $\mathrm{T_{raw\_sc}} = \mathrm{T_{raw} / kT}$ </div>
  1. Calculate compensated measurement results.
<div class="mineru-algorithm" style="white-space: pre-wrap; font-family:monospace;"> $\mathrm{T_{comp}}$ (°C) = c0*0.5 + c1*Traw_sc </div>

4.9.3 Compensation Scale Factors

Table 9 Compensation Scale Factors

Oversampling RateScale Factor (kP or kT)Result shift ( bit 2and 3 address 0x09)
1 (single)5242880
2 times (Low Power)15728640
4 times36700160
8 times78643200
16 times (Standard)253952enable pressure or temperature shift
32 times516096enable pressure or temperature shift
64 times (High Precision)1040384enable pressure or temperature shift
128 times2088960enable pressure or temperature shift

4.9.4 Pressure and Temperature calculation flow

The flow chart below describes the Pressure and Temperature calculate

Figure 6 Pressure and temperature calculation flow

Functional Description


See also How to Calculate Compensated Pressure Values and How to Calculate Compensated Temperature Values

Applications

5

Applications

5.1 Measurement Settings and Use Case Examples

Table 10
Measurement Settings and Use Case Examples (TBD)

Use CasePerformancePressure Register Configuration Address: 0x06Temperature Register Configuration Address: 0x07Other
Weather Station (Low power)5 Pa precision.1 pr sec.3 uA0x010x80Start background measurements (addr 0x08)
Indoor navigation (Standard precision, background mode)10 cm precision.2 pr sec.22 uA0x140x90Enable P shift (addr 0x09)Start background measurements (addr 0x08)
Sports (High precision, high rate, background mode)5 cm precision4 pr sec.200 uA0x260xA0Enable P shift (addr 0x09)Start background measurements (addr 0x08)

Applications

5.2

Application Circuit Example

The examples application circuit uses the I2C and SPI serial interface. The SDO pin can be used for interrupt or to set least significant bit of the device address. The DPS310 analog core supply voltage is internally regulated, guaranteeing robustness to external VDD supply variations within the specified range. The simplest voltage supply solution is to connect VDD and VDDIO to 1.8V supply and add a suitable decoupling capacitor to reduce VDD ripple below 50mVpp.


Figure 7 Application Circuit Example using the I2C serial interface.


Figure 8
Application Circuit Example using the SPI 4-wires serial interface


Figure 9
Application Circuit Example using the SPI 3-wire serial interface

Digital interfaces

ProcessorSPI Serial InterfacePressure Sensor
SCLSCK
IO_0SDI
IO_1SDO
SSCSB

Figure 10 Application Circuit Example using the SPI 3-wire with interrupt interface

Table 11 Component Values

ComponentSymbolValuesUnitNote / Test Condition
Min.Typ.Max.
Pull-up/down Resistor $R_1, R_2$ 10KΩ
$R_3$ 100KΩ $R_3$ is optional and will set the address to 0x76 instead of 0x77.
Supply Blocking Capacitor $C_1, C_2$ 100100nFThe blocking capacitors should be placed as close to the package pins as possible.

5.3 IIR filtering

The air pressure is slowly changing due to weather conditions or short term changing like air turbulence created by a fan, slamming a door or window. All these disturbances can be suppressed or triggered on the software application level by implementing diferent IIR filtering.

Same sensor can be used by diferent software applications applying diferent IIR filtering to the raw data like low pass, high pass or band pass filtering.

6

Digital interfaces

The DPS310 measurement data, calibration coeficients, Product ID and configuration registers can be accessed through both the I2C and SPI serial interfaces.

The SPI interface can configured to operate in 3-wire or 4-wire mode. In I2C and SPI 3-wire, an interrupt output can be implemented on the SDO pin. The SPI interface support mode '11' only ( CPOL=CPHA='1' ) in 4-wire and 3-wire configuration. The following commands are supported: single byte write, single byte read and multiple byte read using auto increment from a specified start address. The interface selection is done based on CSB pin status. If CSB is connected to $V _ { \mathsf { D D I O } }$ , the I2C interface is active. If CSB is low, the SPI interface is active. After the CSB has been pulled down once the I2C interface is disabled until the next power-on-reset.

Digital interfaces

6.1

I2C Interface

The I2C slave interface is compatible with Philips I2C Specification version 2.1. The I2C interface supports standard, fast and high speed mode.

The sensor's address is 0x77 (if SDO pin is left floating or pulled-up to VDDIO) or 0x76 (if the SDO pin is pulled-down to GND). The I2C interface uses the pins described in Table 2

The basic timing is shown in the diagram below:

Figure 13 SPI protocol, 4-wire without interrupt

Figure 11 I2C timing diagram

In one access, without stop, incremental read (address is auto increment) and auto-incremental write is supported. The read and write access is described below:


Figure 12 I2C write and read commands

6.2 SPI Interface

The SPI interface is compatible with SPI mode '11' ( CPOL = CPHA = '1'. The SPI interface has two modes: 4-wire and 3-wire.

The protocol is the same for both. The 3-wire mode is selected by setting '1' to the register Interrupt and FIFO configuration (CFG_REG)

The SPI interface uses the pins like in theTable 2 Refere toApplication Circuit Example for connections instructions. The SPI protocol is shown in the diagram below:

Digital interfaces

A SPI write is carried out by setting CSB low and sending a control byte followed by register data. The control byte consist of the SPI register address ( full register address without bit 7) and the write command ( bit7 = RW = '0'). Setting CSB high ends the transaction. The SPI write protocol is described in the diagram below.

A SPI read is initiated by setting CSB low and sending a single control byte. The control byte consist of the SPI register address ( = full register address without bit 7) and the read command ( bit7 = RW = '1'). After writing the control byte, data is sent out of the SDO pin ( SDI in 3-wire mode); the register address is automatically incremented. Sending CSB high ends the SPI read transaction. The SPI read protocol is shown in the diagram below:


Figure 14 SPI write, read protocol diagrams

Digital interfaces

6.3 Interface parameters specification

6.3.1 General interface parameters

The general interface parameters are given in the table below:

Table 12 Interface parameters

ParameterSymbolValuesUnitNote or Test Condition
Min.Typ.Max.
Input voltage for low logic level at input pinsVlow_in0.3* $V_{DDIO}$ V $V_{DDIO}=1.2V$ to 3.6V
Input voltage for high logic level at input pinsVhigh_in0.7* $V_{DDIO}$ V $V_{DDIO}=1.2V$ to 3.6V
Output - low level for I2CVlow_SDI0.1* $V_{DDIO}$ V $V_{DDIO}=1.8V, \text{iol}=2mA$
Output voltage for low level at pin SDI for I2CVlow_SDI_1.20.2* $V_{DDIO}$ V $V_{DDIO}=1.20V, \text{iol}=1.3mA$
Output voltage for high level at pins SDO, SDIVhigh_out0.8* $V_{DDIO}$ V $V_{DDIO}=1.8V, \text{iol}=1mA$ (SDO, SDI)
Output voltage for high level at pins SDO, SDIVhigh_out_1.20.6* $V_{DDIO}$ V $V_{DDIO}=1.2V, \text{iol}=1mA$ (SDO, SDI)
Pull-up resistorRpull60120180kohmInternal pull-up resistance to $V_{DDIO}$
$I^{2}C$ bus load capacitorCb400pFOn SDI and SCK

6.3.1.1 I2C timings

The I2C timing is shown in the diagram below and corresponding values are given in the table below. The naming refers to I2C Specification version 2.1, the abbreviations used "S&F mode" = standard and fast mode, "HS mode" = high speed mode, Cb = bus capacitance on SDA line.

Digital interfaces


Data transfer on the I2C-bus


Figure 15

I2C timing diagram

Table 13 I2C timings

ParameterSymbolValuesUnitNote or Test Condition
Min.Typ.Max.
Data setup time on SDI pin $t_{Setup}$ 20nsS&amp;F mode
5nsHS mode
Data hold time on SDI pin $t_{Hold}$ 0nsS&amp;F&amp;HSmode,
Duty CycleDC70%S&amp;F mode,
55%HS mode,

Digital interfaces

6.3.1.2 SPI timings

The SPI timing diagram is shown in the figure below and the corresponding values are given in the table below. All timings apply both to 4-wire and 3-wire SPI.


Figure 16 SPI timing diagram

Table 14 SPI timings

ParameterSymbolValuesUnitNote or Test Condition
Min.Typ.Max.
Duty Cycle (Thigh%)SPI_DC30% $V_{DDIO} = 1.2V$
20% $V_{DDIO} = 1.8V/3.6V$
SDI setup timeT_setup_sdi2ns
SDI hold timeT_hold_sdi2ns
ClockSPI_CLK10MHz
CSB setup timeT_setup_csb15ns
CSB hold time15ns

Register Map

7

Register Map

Register NameAddr.bit7bit6bit5bit4bit3bit2bit1bit0Reset State
PSR_B20x00PSR[23:16] (r) $00_h$
PSR_B10x01PSR[15:8](r) $00_h$
PSR_B00x02PSR[7:0](r) $00_h$
TMP_B20x03TMP[23:16] (r) $00_h$
TMP_B10x04TMP[15:8] (r) $00_h$
TMP_B00x05TMP[7:0] (r) $00_h$
PRS_CFG0x06-PM_RATE [2:0] (rw)PM_PRC [3:0] (rw) $00_h$
TMP_CFG0x07TMP_EXT(rw)TMP_RATE [2:0] (rw)TM_PRC [3:0] (rw) $00_h$
MEAS_CFG0x08COEF_RDY (r)SENSOR_RDY (r)TMP_RDY (r)PRS_RDY (r)-MEAS_CTRL [2:0] (rw) $C0_h$
CFG_REG0x09INT_HL(rw)INT_SEL [2:0] (rw)TMP_SHIFT_EN (rw)PRS_SHIFT_EN (rw)FIFO_EN (rw)SPI_MODE(rw) $00_h$
INT_STS0x0A-----INT_FIFO_FULL (r)INT_TMP(r)INT_PRS(r) $00_h$
FIFO_STS0x0B------FIFO_FULL(r)FIFO_EMPTY(r) $00_h$
RESET0x0CFIFO_FLUSH(w)---SOFT_RST [3:0] (w) $00_h$
Product ID0x0DREV_ID [3:0] (r)PROD_ID [3:0] (r) $10_h$
COEF0x10-0x21&lt; see register description &gt; $XX_h$
Reserved0x22-0x27Reserved $XX_h$
COEF_SRCE0x28TMP_COEF_SRCE (r)Reserved $XX_h$

8 Register description

8.1 Pressure Data (PRS_Bn)

The Pressure Data registers contains the 24 bit (3 bytes) 2's complement pressure measurement value. If the FIFO is enabled, the register will contain the FIFO pressure and/or temperature results. Otherwise, the register contains the pressure measurement results and will not be cleared after read.

Register description

8.1.1 PRS_B2

The highest byte of the three bytes measured pressure value.

PRS_B2Address: $00_{H}$
Pressure (MSB data)Reset value: $00_{H}$
76543210
PRS[23:16]
FieldBitsTypeDescription
PRS[23:16]7:0rMSB of 24 bit 2&#x27;s complement pressure data.

8.1.2 PRS_B1

The middle byte of the three bytes measured pressure value.

PRS_B1Address: $01_{H}$
Pressure (LSB data)Reset value: $00_{H}$
76543210
PRS[15:8]
FieldBitsTypeDescription
PRS[15:8]7:0rLSB of 24 bit 2&#x27;s complement pressure data.

Register description

8.1.3 PRS_B0

The lowest byte of the three bytes measured pressure value.

PRS_B0Address: $02_{H}$
Pressure (XLSB data)Reset value: $00_{H}$
76543210
PRS[7:0]
FieldBitsTypeDescription
PRS[7:0]7:0rXLSB of 24 bit 2&#x27;s complement pressure data.

8.2 Temperature Data (TMP_Tn)

The Temperature Data registers contain the 24 bit (3 bytes) 2's complement temperature measurement value ( unless the FIFO is enabled, please see FIFO operation ) and will not be cleared after the read.

8.2.1 TMP_B2

The highest byte of the three bytes measured temperature value.

TMP_B2Address: $03_{H}$
Temperature (MSB data)Reset value: $00_{H}$
76543210
TMP[23:16]
FieldBitsTypeDescription
TMP[23:16]7:0rMSB of 24 bit 2&#x27;s complement temperature data.

Register description

8.2.2 TMP_B1

The middle byte of the three bytes measured temperature value.

TMP_B1Address: $04_{H}$
Temperature (LSB data)Reset value: $00_{H}$
76543210
TMP[15:8]
FieldBitsTypeDescription
TMP[15:8]7:0rLSB of 24 bit 2&#x27;s complement temperature data.

8.2.3 TMP_B0

The lowest part of the three bytes measured temperature value.

TMP_B0Address: $05_{H}$
Temperature (XLSB data)Reset value: $00_{H}$
76543210
TMP[7:0]
FieldBitsTypeDescription
TMP[7:0]7:0rXLSB of 24 bit 2&#x27;s complement temperature data.

*) Note: Use in combination with a bit shift. See Interrupt and FIFO configuration (CFG_REG) register

Register description

8.3 Pressure Configuration (PRS_CFG)

Configuration of pressure measurement rate (PM_RATE) and resolution (PM_PRC).

PRS_CFGAddress:06H
Pressure measurement configurationReset value:00H
765432
-PM_RATE[2:0]PM_PRC[3:0]
-rwrw
FieldBitsTypeDescription
-7-Reserved.
PM_RATE[2:0]6:4rwPressure measurement rate:000 - 1 measurements pr. sec.001 - 2 measurements pr. sec.010 - 4 measurements pr. sec.011 - 8 measurements pr. sec.100 - 16 measurements pr. sec.101 - 32 measurements pr. sec.110 - 64 measurements pr. sec.111 - 128 measurements pr. sec.Applicable for measurements in Background mode only
PM_PRC[3:0]3:0rwPressure oversampling rate:0000 - Single. (Low Precision)0001 - 2 times (Low Power).0010 - 4 times.0011 - 8 times.0100 *) - 16 times (Standard).0101 *) - 32 times.0110 *) - 64 times (High Precision).0111 *) - 128 times.1xxx - Reserved

Register description

Table 16 Precision (PaRMS) and pressure measurement time (ms) versus oversampling rate

Oversampling (PRC[3:0])Single (0000)2 times (0001)4 times (0010)8 times (0011)16 times (0100)32 times (0101)64 times (0110)128 times (0111)
Measurement time (ms)3.65.28.414.827.653.2104.4206.8
Precision ( $Pa_{RMS}$ )2.510.50.40.350.30.2

Table 17
Estimated current consumption (uA)

Oversampling (PRC[3:0])Single (0000)2 times (0001)4 times (0010)8 times (0011)16 times (0100)32 times (0101)64 times (0110)128 times (0111)
Measurements pr sec. (PM_RATE([2:0])
1 (000)2.12.73.86.111203875
2 (001)
4 (010)
8 (011)Note: The current consumption can be calculated as the Measurement Rate * Current Consumption of 1 measurement per. sec.n.a.
16 (100)n.a.n.a.
32 (101)n.a.n.a.n.a.
64 (110)n.a.n.a.n.a.n.a.
128 (111)n.a.n.a.n.a.n.a.n.a.n.a.

Note: The table shows the possible combinations of Pressure Measurement Rate and oversampling when no temperature measurements are performed. When temperature measurements are performed the possible combinations are limited to Ratetemperature x Measurement $T i m e _ { \mathrm { t e m p e r a t u r e } } + R a t e _ { \mathrm { p r e s s u r e } }$ x Measurement Timepressure < 1 second.

The temperature measurement time versus temperature oversampling rate is similar with pressure measurement time versus pressure oversampling rate

Register description

8.4 Temperature Configuration(TMP_CFG)

Configuration of temperature measurement rate (TMP_RATE) and resolution (TMP_PRC).

TMP_CFGAddress: $07_{H}$
Temperature measurement configurationReset value: $00_{H}$
76543210
TMP_EXTTMP_RATE[2:0]TMP_PRC[2:0]
rwrwrw
FieldBitsTypeDescription
TMP_EXT7rwTemperature measurement0 - Internal sensor (in ASIC)1 - External sensor (in pressure sensor MEMS element)Note: It is highly recommended to use the same temperature sensor as the source of the calibration coefficients. Please see the Coefficient Source register
TMP_RATE[2:0]6:4rwTemperature measurement rate:000 - 1 measurement pr. sec.001 - 2 measurements pr. sec.010 - 4 measurements pr. sec.011 - 8 measurements pr. sec.100 - 16 measurements pr. sec.101 - 32 measurements pr. sec.110 - 64 measurements pr. sec.111 - 128 measurements pr. sec..Applicable for measurements in Background mode only
TMP_PRC[2:0]3:0rwTemperature oversampling (precision):0000 - single. (Default) - Measurement time 3.6 ms.Note: Following are optional, and may not be relevant:0001 - 2 times.0010 - 4 times.0011 - 8 times.0100 - 16 times.0101 - 32 times.0110 - 64 times..0111 - 128 times.1xxx - Reserved.

Register description

8.5 Sensor Operating Mode and Status (MEAS_CFG)

Setup measurement mode.

MEAS_CFGAddress:08H
Measurement configurationReset value:C0H
76543210
COEF_RDYSENSOR_RDYTMP_RDYPRS_RDY-MEAS_CTRL
rrrr-rw
FieldBitsTypeDescription
COEF_RDY7rCoefficients will be read to the Coefficients Registers after start-up:0 - Coefficients are not available yet.1 - Coefficients are available.
SENSOR_RDY6rThe pressure sensor is running through self initialization after start-up.0 - Sensor initialization not complete1 - Sensor initialization completeIt is recommend not to start measurements until the sensor has completed the self initialization.
TMP_RDY5rTemperature measurement ready1 - New temperature measurement is ready. Cleared when temperature measurement is read.
PRS_RDY4rPressure measurement ready1 - New pressure measurement is ready. Cleared when pressure measurement is read.
-3-Reserved.
MEAS_CTRL2:0rwSet measurement mode and type:Standby Mode000 - Idle / Stop background measurementCommand Mode001 - Pressure measurement010 - Temperature measurement011 - na.100 - na.Background Mode101 - Continuous pressure measurement110 - Continuous temperature measurement111 - Continuous pressure and temperature measurement

Register description

8.6 Interrupt and FIFO configuration (CFG_REG)

Configuration of interupts, measurement data shift, and FIFO enable.

CFG_REGAddress:09H
Configuration registerReset value:00H
76543210
INT_HLINT_FIFOINT_TMPINT_PRST_SHIFTP_SHIFTFIFO_ENSPI_MODE
rwrwrwrwrwrwrwrw
FieldBitsTypeDescription
INT_HL7rwInterrupt (on SDO pin) active level:0 - Active low.1 - Active high.
INT_FIFO6rwGenerate interrupt when the FIFO is full:0 - Disable.1 - Enable.
INT_TMP5rwGenerate interrupt when a temperature measurement is ready:0 - Disable.1 - Enable.
INT_PRS4rwGenerate interrupt when a pressure measurement is ready:0 - Disable.1 - Enable.
T_SHIFT3rwTemperature result bit-shift0 - no shift.1 - shift result right in data register.Note: Must be set to &#x27;1&#x27; when the oversampling rate is &gt;8 times.
P_SHIFT2rwPressure result bit-shift0 - no shift.1 - shift result right in data register.Note: Must be set to &#x27;1&#x27; when the oversampling rate is &gt;8 times.
FIFO_EN1rwEnable the FIFO:0 - Disable.1 - Enable.
SPI_MODE0rwSet SPI mode:0 - 4-wire interface.1 - 3-wire interface.

Register description

8.7 Interrupt Status (INT_STS)

Interrupt status register. The register is cleared on read.

INT_STSAddress: $0A_{H}$
Interrupt statusReset value: $00_{H}$
765432
-INT_FIFO_FULLINT_TMP
-rr
FieldBitsTypeDescription
-7:3-Reserved.
INT_FIFO_FULL2rStatus of FIFO interrupt0 - Interrupt not active1 - Interrupt active
INT_TMP1rStatus of temperature measurement interrupt0 - Interrupt not active1 - Interrupt active
INT_PRS0rStatus of pressure measurement interrupt0 - Interrupt not active1 - Interrupt active

Register description

8.8

FIFO Status (FIFO_STS)

FIFO status register

FIFO_STSAddress: $0B_{H}$
FIFO status registerReset value: $00_{H}$
76543210
-FIFO_FULLFIFO_EMPTY
FieldBitsTypeDescription
-7:2-Reserved.
FIFO_FULL1r0 - The FIFO is not full1 - The FIFO is full
FIFO_EMPTYRESET0Address:r0 - The FIFO is not empty1 - The FIFO is empty
$0C_{H}$
FIFO flush and soft resetReset value: $00_{H}$
76543210
FIFO_FLUSH-SOFT_RST
w-w

Register description

8.9

Soft Reset and FIFO flush (RESET)

Flush FIFO or generate soft reset.

FieldBitsTypeDescription
FIFO_FLUSH7wFIFO flush1 - Empty FIFOAfter reading out all data from the FIFO, write &#x27;1&#x27; to clear all old data.
-6:4-Reserved.
SOFT_RST3:0wWrite &#x27;1001&#x27; to generate a soft reset. A soft reset will run though the same sequences as in power-on reset.

8.10 Product and Revision ID (ID)

Product and Revision ID.

IDAddress: $0D_{H}$
Product and revision IDReset value: $0x10_{H}$
76543210
REV_IDPROD_ID
FieldBitsTypeDescription
REV_ID7:4rRevision ID
PROD_ID3:0rProduct ID

Register description

8.11 Calibration Coeficients (COEF)

The Calibration Coeficients register contains the 2´s complement coeficients that are used to calculate the compensated pressure and temperature values.

Table 18 Calibration Coeficients

CoefficientAddr.bit7bit6bit5bit4bit3bit2bit1bit0
c00x10c0 [11:4]
c0/c10x11c0 [3:0]c1 [11:8]
c10x12c1[7:0]
c000x13c00 [19:12]
c000x14c00 [11:4]
c00/c100x15c00 [3:0]c10 [19:16]
c100x16c10 [15:8]
c100x17c10 [7:0]
c010x18c01 [15:8]
c010x19c01 [7:0]
c110x1Ac11 [15:8]
c110x1Bc11 [7:0]
c200x1Cc20 [15:8]
c200x1Dc20 [7:0]
c210x1Ec21 [15:8]
c210x1Fc21 [7:0]
c300x20c30 [15:8]
c300x21c30 [7:0]

Note: Generate the decimal numbers out of the calibration coeficients registers data:
C20 := reg0x1D + reg0x1C * 2^ 8

if (C20 > (2^15 - 1))

end if

C0 := (reg0x10 * 2^4) + ((reg0x11 / 2^4) & 0x0F)

if (C0 > (2^11 - 1))

C0 := C0 - 2^12

end if

Package Dimensions

8.12 Coeficient Source

States which internal temperature sensor the calibration coeficients are based on: the ASIC temperature sensor or the MEMS element temperature sensor. The coeficients are only valid for one sensor and it is highly recommended to use the same temperature sensor in the application. This is set-up in the Temperature Configuration register.

TMP_COEF_SRCEAddress: $28_{H}$
Temperature Coefficients SourceReset value: $XX_{H}$
76543210
TMP_COEF_SRCE-
FieldBitsTypeDescription
TMP_COEF_SRCE7rTemperature coefficients are based on:0 - Internal temperature sensor (of ASIC)1 - External temperature sensor (of pressure sensor MEMS element)
-6:0-Reserved

9 Package Dimensions

The sensor package is a 8-pin PG-VLGA-8-1, 2.0 x 2.5 x 1 mm3, with 0.65 mm pitch.

10 Package Handling

Further Information please refer to the attached “Digital Barometric Pressure Sensor_ Package Handling”. It describes the package handling and delivery format.

11 Reflow soldering and board assembly

The Infineon pressure sensors are qualified in accordance with the IPC/JEDEC J-STD-020D-01. The moisture sensitivity level of pressure sensor is rated as MSL1. For PCB assembly of the sensor the widely used reflow soldering using a forced convection oven is recommended.

The soldering profile should be in accordance with the recommendations of the solder paste manufacturer to reach an optimal solder joint quality. The reflow profile shown in figure below is recommended for board manufacturing with Infineon pressure sensors.

Figure 17

Reflow soldering and board assembly

Table 19 Reflow profile limits

Profile featurePb-Free assemblySn-Pb Eutectic assembly
Preheat/Soak
Temperature Min ( $T_{smin}$ )150 °C100 °C
Temperature Max ( $T_{smax}$ )200 °C150 °C
Time ( $T_{smin}$ to $T_{smax}$ ) ( $t_s$ )60-120 seconds60-150 seconds
Peak Temperature ( $T_p$ )260°C +0°C/-5°C235°C +0°C/-5°C
Time within 5°C of actual peak temperature (tp)*20-40 seconds10-30 seconds
Ramp-down rate6 °C/second max.6 °C/second max.
Time 25°C to peak temperature8 minutes max.6 minutes max.
* Tolerance for peak profile temperature ( $T_p$ ) is defined as a supplier minimum and a user maximum

Note: For further information please consult the 'General recommendation for assembly of Infineon packages' document which is available on the Infineon Technologies web page

Revision History

The Infineon pressure sensors can be handled using industry standard pick and place equipment. Care should be taken to avoid damage to the sensor structure as follows:

• Do not pick the sensor with vacuum tools which make contact with the sensor vent port hole

• The sensor's vent hole should not be exposed to vacuum, this can destroy or damage the MEMS

Do not blow air into the sensor vent hole. If an air blow cleaning process is used, the vent hole must be sealed to prevent particle contamination.

• It is recommended to perform the PCB assembly in a clean room environment in order to avoid sensor contamination.

Air blow and ultrasonic cleaning procedures shall not be applied to MEMS pressure sensors. A non-clean paste is recommended for the assembly to avoid subsequent cleaning steps. The MEMS sensor can be severely damaged by cleaning substances.

• To prevent the blocking or partial blocking of vent hole during PCB assembly, it is recommended to cover the sound port with protective tape during PCB sawing or system assembly.

Do not use excessive force to place the sensor on the PCB. The use of industry standard pick and place tools is recommended in order to limit the mechanical force exerted to the package.

Revision History

Major changes since previous revision

Revision History
ReferenceDescription
1.0Initial released
1.1Title update; table 7 update; add reflow soldering chapter
1.2Package dimensions typo fix

Known Issues List

Known Issues
Product and Revision IDDescription

Trademarks

All referenced product or service names and trademarks are the property of their respective owners.

Edition 2020-10-15 Published by Infineon Technologies AG 81726 Munich, Germany

© 2020 Infineon Technologies AG All Rights Reserved.

Do you have a question about any aspect of this document? Email: erratum@infineon.com

Document reference IFX-sch1406115644540

IMPORTANT NOTICE

The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics (“Beschafenheitsgarantie”) .

With respect to any examples, hints or any typical values stated herein and/or any information regarding the application of the product, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party.

In addition, any information given in this document is subject to customer’s compliance with its obligations stated in this document and any applicable legal requirements, norms and standards concerning customer’s products and any use of the product of Infineon Technologies in customer’s applications.

The data contained in this document is exclusively intended for technically trained staf. It is the responsibility of customer’s technical departments to evaluate the suitability of the product for the intended application and the completeness of the product information given in this document with respect to such application.

WARNINGS

Due to technical requirements products may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies ofice.

Except as otherwise explicitly approved by Infineon Technologies in a written document signed by authorized representatives of Infineon Technologies, Infineon Technologies’ products may not be used in any applications where a failure of the product or any consequences of the use thereof can reasonably be expected to result in personal injury.

Extracted Images

Figures and diagrams from the PDF

Preview the extracted datasheet assets and open any image in a separate tab for closer inspection.

ID register address and reset value

ID register address and reset value

Pressure measurement configuration register fields

Pressure measurement configuration register fields

Absolute maximum ratings table

Absolute maximum ratings table

MEAS_CFG measurement configuration register map

MEAS_CFG measurement configuration register map

FIFO status register field descriptions

FIFO status register field descriptions

I2C byte transfer with start, acknowledgment, and stop conditions

I2C byte transfer with start, acknowledgment, and stop conditions

RESET register bit-field layout

RESET register bit-field layout

Register field descriptions for readiness and measurement control

Register field descriptions for readiness and measurement control

INT_STS interrupt status register layout

INT_STS interrupt status register layout

Known issues table

Known issues table

Oversampling rates and scale factors

Oversampling rates and scale factors

Digital input and output electrical characteristics

Digital input and output electrical characteristics

Component values and capacitor recommendations

Component values and capacitor recommendations

Current consumption specifications

Current consumption specifications

8-pin package pinout

8-pin package pinout

I2C and SPI clock specifications

I2C and SPI clock specifications

TMP_COEF_SRCE register bit field

TMP_COEF_SRCE register bit field

PRS_B1 pressure data register metadata

PRS_B1 pressure data register metadata

Extracted datasheet image 133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg.

Extracted datasheet image 133cd97f281bf83a404b98e99f9a7e4addf3fb358fa48636863bdeaa559c8efc.jpg.

Extracted datasheet image 3a3f8c679c7d859d66a2bfebe445bee14d590055aa6ebbce462b6b26bf9579a9.jpg.

Extracted datasheet image 3a3f8c679c7d859d66a2bfebe445bee14d590055aa6ebbce462b6b26bf9579a9.jpg.

Extracted datasheet image 84807abb892a230ec71f25181dc2edef04e67383962b68a129507ab9c4727e22.jpg.

Extracted datasheet image 84807abb892a230ec71f25181dc2edef04e67383962b68a129507ab9c4727e22.jpg.

Extracted datasheet image 2af4785127173a518e00c97725461c35536055a163dec9b6f49cb7e24b6e3f47.jpg.

Extracted datasheet image 2af4785127173a518e00c97725461c35536055a163dec9b6f49cb7e24b6e3f47.jpg.

Extracted datasheet image b540ff87f0f00da9b77cc7b0ae19d924b1d1885b99a0d74c3ba9a20865b3b0ee.jpg.

Extracted datasheet image b540ff87f0f00da9b77cc7b0ae19d924b1d1885b99a0d74c3ba9a20865b3b0ee.jpg.

Extracted datasheet image 8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg.

Extracted datasheet image 8b1ae518b4c4c3fc0643e8dff6e5c6e1b28ad4b3ffa68d6ecba69450bd0a3330.jpg.

PRS register bit-field diagram

PRS register bit-field diagram

TMP_B0 register description

TMP_B0 register description

I2C write and read command sequences for DPS310

I2C write and read command sequences for DPS310

Temperature configuration register field descriptions

Temperature configuration register field descriptions

DPS310 register map

DPS310 register map

PRS pressure data field description

PRS pressure data field description

Initialization and coefficient readout timing sequence

Initialization and coefficient readout timing sequence

Interrupt status register field descriptions

Interrupt status register field descriptions

Coefficient register address and bit allocation table

Coefficient register address and bit allocation table

Measurement rate versus oversampling configuration table

Measurement rate versus oversampling configuration table

Product and revision ID register bit allocation

Product and revision ID register bit allocation

SPI timing and duty-cycle specifications

SPI timing and duty-cycle specifications

Extracted datasheet image bee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg.

Extracted datasheet image bee6f5e5b946a73cb1ebde6aaafb20562614eca183429856c4206d855bebb4a2.jpg.

Extracted datasheet image 8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg.

Extracted datasheet image 8022eb431f1faf3c2ff8192b34198dbf86f8382c9d7eb8c56e267edae1910d60.jpg.

Extracted datasheet image 02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg.

Extracted datasheet image 02c67aadfd1faec9850d001cb6c859938d0ce74bd1d20ab8a14c9f4d444cdf35.jpg.

Extracted datasheet image 3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg.

Extracted datasheet image 3a373ae3477b93c490f8e54b061a8bc6f2bc9d9a2af25d3357b482225b679e55.jpg.

Extracted datasheet image 4b931c18df0a8dabf720284ec83eeba0cd20d41a3cca84e9443022a4ed0bde73.jpg.

Extracted datasheet image 4b931c18df0a8dabf720284ec83eeba0cd20d41a3cca84e9443022a4ed0bde73.jpg.

Extracted datasheet image a9255f1595866d812c40d51f92572565a5bd2f5ea6a3f5516d31331b406c8c93.jpg.

Extracted datasheet image a9255f1595866d812c40d51f92572565a5bd2f5ea6a3f5516d31331b406c8c93.jpg.

FIFO status register entry

FIFO status register entry

Revision history table

Revision history table

Operating conditions and stability specifications

Operating conditions and stability specifications

Clock and data timing diagram

Clock and data timing diagram

SPI connection between processor and pressure sensor

SPI connection between processor and pressure sensor

Pressure accuracy and precision specifications

Pressure accuracy and precision specifications

Use-case configuration table with pressure and temperature register values

Use-case configuration table with pressure and temperature register values

TMP register bit-field showing the eight-bit TMP value

TMP register bit-field showing the eight-bit TMP value

TMP_B1 temperature register address and reset value

TMP_B1 temperature register address and reset value

TMP coefficient source register field description

TMP coefficient source register field description

Pressure and temperature sensor signal-processing block diagram

Pressure and temperature sensor signal-processing block diagram

Raw-to-scaled temperature and pressure conversion equations

Raw-to-scaled temperature and pressure conversion equations

TMP_B2 temperature register bit field

TMP_B2 temperature register bit field

PRS_CFG pressure measurement configuration register

PRS_CFG pressure measurement configuration register

Register field definitions for revision and product identifiers

Register field definitions for revision and product identifiers

Register fields for FIFO flush and soft reset

Register fields for FIFO flush and soft reset

SPI timing diagram for CSB, SCK, SDI, and SDO

SPI timing diagram for CSB, SCK, SDI, and SDO

Oversampling settings with measurement time and precision

Oversampling settings with measurement time and precision

Temperature reflow profile showing preheat, ramp-up, peak, critical zone, and ramp-down.

Temperature reflow profile showing preheat, ramp-up, peak, critical zone, and ramp-down.

Glossary table defining sensor measurement and calibration terms.

Glossary table defining sensor measurement and calibration terms.

Timing electrical characteristics for SDI data and duty cycle.

Timing electrical characteristics for SDI data and duty cycle.

PRS_B0 pressure least-significant-byte register bit field.

PRS_B0 pressure least-significant-byte register bit field.

Pin function table for SPI and I²C operating modes.

Pin function table for SPI and I²C operating modes.

SPI connection schematic between a processor and pressure sensor with supply decoupling.

SPI connection schematic between a processor and pressure sensor with supply decoupling.

Reflow soldering profile specifications for Pb-free and Sn-Pb assemblies

Reflow soldering profile specifications for Pb-free and Sn-Pb assemblies

Pressure measurement performance specifications

Pressure measurement performance specifications

TMP register field TMP[15:8]

TMP register field TMP[15:8]

TMP_CFG temperature measurement configuration register

TMP_CFG temperature measurement configuration register

Processor-to-pressure-sensor serial interface and power connections

Processor-to-pressure-sensor serial interface and power connections

Serial bus START, acknowledgment, byte transfer, and STOP timing

Serial bus START, acknowledgment, byte transfer, and STOP timing

MM control state flow diagram

MM control state flow diagram

Register bit field showing FIFO status flags

Register bit field showing FIFO status flags

Temperature register field definition

Temperature register field definition

Electrical characteristics table header

Electrical characteristics table header

SPI read/write transfer timing diagrams

SPI read/write transfer timing diagrams

Pressure register field definition

Pressure register field definition

Register field descriptions for interrupt, shifting, FIFO, and SPI mode settings

Register field descriptions for interrupt, shifting, FIFO, and SPI mode settings